Features and Benefits Consolidation Points are intended to provide increased flexibility and economy for installations where open office spaces require frequent reconfiguration. Instead of re-routing or installing new cable from a telecommunications closet, horizontal cabling can be accessed and repositioned without re-testing by means of a Consolidation Point Enclosure and Consolidation Point to Telecommunications Outlet (CP to TO) cable assemblies. For example, when moves, adds and changes (MACs) are required between fixed cabling and moveable furniture system layouts, particularly when solid floors are installed. The Consolidation Point Enclosures feature 6 or 8 shuttered PowerCat 6 modules, housed in a rugged graphite grey finished steel enclosure, which protects the incoming cable, but allows ready access to the Consolidation Point to Telecommunication Outlet Links. Designed for easy installation in ceiling voids or under floor, the product is TIA/ EIA TSB75 compliant. Two enclosures may be interconnected, allowing for expansion. The DataGate Category 6 connector is also a feature of the Consolidation Point enclosures. This superior RJ45 IDC includes a unique integral shutter that not only protects the connector from dust and contaminants, but the ingenious spring-loaded design also ejects improperly seated patch cords. The DataGate connector is dual colour coded for either 568A or 568B wiring schedules and is RJ11 compatible. Suitable for high-speed data transmission, the DataGate Category 6 connector has been designed to exceed the highest electrical performance standards in the industry and has been independently tested and verified by ETL SEMKO for Category 6 component compliance. The DataGate connector is also backwards compatible with C5E systems. Solid Cable Assemblies provide the essential interconnection between the CP to the TO. Factory assembled and tested, these links are manufactured using solid cable and are terminated at each end with an RJ45 plug, allowing the assembly to be cut in half on-site prior to terminating. n Allows moves, adds and changes without re-terminating and re-testing of cable n 6 or 8 port s DataGate modules n Rugged graphite grey enclosure n TSB 75 compliant n Factory assembled and performance tested interconnection cords Commercial Standards UL-1863 (Pending) CSA (Pending) ETL Verified for Category 6 Component Compliance Technical Information Mechanical Characteristics Jack Connector Plastic Housing: Polycarbonate, UL94V-0 rated or equivalent Operating Life: Minimum 750 insertion cycles Contact Material: Copper Alloy Contact Plating: 1.27 micrometres Au/Ni Contact Force: 100g minimum Plug Retention Force: 6.8kg IDC Connector Plastic Housing: Polycarbonate, UL94V-0 rated or equivalent Operating Life: Minimum 20 Reterminations Contact Material: Copper Alloy IDC Contact Plating: Tin/Lead Plate Contact Force: 100g minimum Wire Accommodation: 22-24 AWG solid Electrical/Optical Characteristics Interface Resistance: <20mΩ Initial Resistance Imbalance: <2.5mΩ Insulation Resistance: >100MΩ Termination Tool: 110 Shipping Weight 1kg Dimensions: 258mm (L) x 78mm (D) x 90mm (H) Solid Cable Assemblies The minimum length of a solid cable assembly is 20 metres. The finished length when installed is therefore 10 metres. Contact Customer Services, a part number will be allocated at time of order. FEATURES AND SPECIFICATIONS PowerCat™ 6 UTP Consolidation Point Enclosure MOLEX PREMISE NETWORKS Americas Tel: 630 969 4550 www.molexpn.com EMEA Tel: 44 (0)2392 205800 www.molexpn.co.uk APAC Tel: 61 3 9971 7111 www.molexpn.com.au ©2014, Molex Premise Networks Printed in the UK Form#CPT-00032_40 Page 1 Issue 2 This information is correct at the time of publication, specifications are subject to change

Upload: others

Post on 26-Sep-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: FEATURES AND SPECIFICATIONS PowerCat™ 6 UTP ......Order No. SAP No. Description CPT-00032 0180080065 PowerCat 6 6 Port Consolidation Point Enclosure RJ45 568B UTP CPT-00033 0180080073

Features and BenefitsConsolidation Points are intended to provide increased flexibility and economy for installations where open office spaces require frequent reconfiguration. Instead of re-routing or installing new cable from a telecommunications closet, horizontal cabling can be accessed and repositioned without re-testing by means of a Consolidation Point Enclosure and Consolidation Point to Telecommunications Outlet (CP to TO) cable assemblies. For example, when moves, adds and changes (MACs) are required between fixed cabling and moveable furniture system layouts, particularly when solid floors are installed.

The Consolidation Point Enclosures feature 6 or 8 shuttered PowerCat 6 modules, housed in a rugged graphite grey finished steel enclosure, which protects the incoming cable, but allows ready access to the Consolidation Point to Telecommunication Outlet Links. Designed for easy installation in ceiling voids or under floor, the product is TIA/EIA TSB75 compliant. Two enclosures may be interconnected, allowing for expansion.

The DataGate Category 6 connector is also a feature of the Consolidation Point enclosures. This superior RJ45 IDC includes a unique integral shutter that not only protects the connector from dust and contaminants, but the ingenious spring-loaded design also ejects improperly seated patch cords. The DataGate connector is dual colour coded for either 568A or 568B wiring schedules and is RJ11 compatible.

Suitable for high-speed data transmission, the DataGate Category 6 connector has been designed to exceed the highest electrical performance standards in the industry and has been independently tested and verified by ETL SEMKO for Category 6 component compliance. The DataGate connector is also backwards compatible with C5E systems.

Solid Cable Assemblies provide the essential interconnection between the CP to the TO. Factory assembled and tested, these links are manufactured using solid cable and are terminated at each end with an RJ45 plug, allowing the assembly to be cut in half on-site prior to terminating.

n Allows moves, adds and changes without re-terminating and re-testing of cablen 6 or 8 port s DataGate modulesn Rugged graphite grey enclosuren TSB 75 compliantn Factory assembled and performance tested interconnection cords

Commercial StandardsUL-1863 (Pending)CSA (Pending)ETL Verified for Category 6 Component Compliance

Technical InformationMechanical CharacteristicsJack ConnectorPlastic Housing: Polycarbonate, UL94V-0 rated or equivalentOperating Life: Minimum 750 insertion cyclesContact Material: Copper AlloyContact Plating: 1.27 micrometres Au/NiContact Force: 100g minimumPlug Retention Force: 6.8kg

IDC ConnectorPlastic Housing: Polycarbonate, UL94V-0 rated or equivalentOperating Life: Minimum 20 ReterminationsContact Material: Copper AlloyIDC Contact Plating: Tin/Lead PlateContact Force: 100g minimumWire Accommodation: 22-24 AWG solid

Electrical/Optical CharacteristicsInterface Resistance: <20mΩInitial Resistance Imbalance: <2.5mΩInsulation Resistance: >100MΩTermination Tool: 110

Shipping Weight 1kgDimensions: 258mm (L) x 78mm (D) x 90mm (H)

Solid Cable AssembliesThe minimum length of a solid cable assembly is 20 metres. The finished length when installed is therefore 10 metres.

Contact Customer Services, a part number will be allocated at time of order.

FEATURES AND SPECIFICATIONS PowerCat™ 6 UTP Consolidation Point Enclosure

MOLEX PREMISE NETWORKS

AmericasTel: 630 969 4550www.molexpn.com

EMEATel: 44 (0)2392 205800

www.molexpn.co.uk

APACTel: 61 3 9971 7111

www.molexpn.com.au

©2014, Molex Premise Networks Printed in the UK Form#CPT-00032_40 Page 1 Issue 2

This information is correct at the time of publication, specifications are subject to change

Page 2: FEATURES AND SPECIFICATIONS PowerCat™ 6 UTP ......Order No. SAP No. Description CPT-00032 0180080065 PowerCat 6 6 Port Consolidation Point Enclosure RJ45 568B UTP CPT-00033 0180080073

Order No. SAP No. Description

CPT-00032 0180080065 PowerCat 6 6 Port Consolidation Point Enclosure RJ45 568B UTP

CPT-00033 0180080073 PowerCat 6 8 Port Consolidation Point Enclosure RJ45 568B UTP

CPT-00034 Consult Molex Base - Consolidation Point Enclosure

CPT-00039 Consult Molex 6 Port (Fully Loaded) Cover C6

CPT-00040 Consult Molex 8 Port (Fully Loaded) Cover C6

Technical InformationElectrical/Optical CharacteristicsDataGate Connector FEXT (Typical)

DataGate Connector NEXT (Typical)

DataGate Worst Case (dB)

FEATURES AND SPECIFICATIONS PowerCat™ 6 UTP Consolidation Point Enclosure

ORDERING INFORMATION

MOLEX PREMISE NETWORKS

AmericasTel: 630 969 4550www.molexpn.com

EMEATel: 44 (0)2392 205800

www.molexpn.co.uk

APACTel: 61 3 9971 7111

www.molexpn.com.au

©2014, Molex Premise Networks Printed in the UK Form#order number Page 1 Issue 1

This information is correct at the time of publication, specifications are subject to change

DataGate Connector Return Loss(Typical)