Specifications Features Limited lifetime warranty - 2-year in home labor warranty where available Proportional Steam Microprocessor based diagnostics and LED indication Stainless Steel Tank Construction Intelligent control communication UL/CUL Listed Required Equipment TSC Control Required Electrical Service Dedicated circuit required: See Specification Chart for proper electrical requirements Product Information Water Supply - ⅜" Compression Fitting, 120 PSI Max Steam Outlet - ¾" Brass NPT male thread Pressure Relief Valve - ¾" NPT female thread Drain Outlet - Capped 1/2" Brass NPT male thread Supplied with a 35’ control cable Generator Weight - 30 lbs. Installation Notes For optimum performance, the steam generator should be mounted as close as possible to the steam room. If needed, the steam pipe may be up to 50’ long. Steam Generators should be accessible for service. Do NOT install near flammable material such as paints, thinners, gasoline, etc. Steam generators must NOT be installed outdoors, in moist, humid areas, in areas prone to freezing, or extreme heat such as an unventilated attic. To do so will void the warranty. Steamhead to be mounted 12" to 18" above floor or 6" above rim of tub and as far from the seating area as possible. Service Access Minimum: 21" W x 18" D x 22" H (28" W with Auto Drain) 05/17 Pub. No. 234-B Steam Generator Models: SMP-5, SMP-7 and SMP-10 - 1 - Steam Generator Specification Chart 5 7.5 10 100 250 450 240/1/21 208/1/24 240/1/31 208/1/36 240/1/42 208/1/48 30 30 40 50 50 60 Product Number KW Rating Max. Cu. Ft. Range* Volts/Phase/ Max. Amps Line Fuse 15" x 6" x 15.5" Dimensions L x W x H SMP-5 SMP-5-208 SMP-7 SMP-7-208 SMP-10 SMP-10-208 * Refer to sizing guidelines to accurately determine the proper size generator for the installation. 90°C copper wire is required for generator connection. Installation shall be in accordance with NEC and local electrical codes. ® Models: SMP-5, SMP-7 and SMP-10

Upload: others

Post on 25-Sep-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Features 5,7...Limited lifetime warranty - 2-year in home labor warranty where available Proportional Steam Microprocessor based diagnostics and LED indication Stainless Steel Tank

Speci�cations

FeaturesLimited lifetime warranty - 2-year in home labor warranty where availableProportional SteamMicroprocessor based diagnostics and LED indication Stainless Steel Tank ConstructionIntelligent control communicationUL/CUL Listed

Required EquipmentTSC Control

Required Electrical ServiceDedicated circuit required: See Specification Chart for proper electrical requirements

Product InformationWater Supply - ⅜" Compression Fitting, 120 PSI MaxSteam Outlet - ¾" Brass NPT male threadPressure Relief Valve - ¾" NPT female threadDrain Outlet - Capped 1/2" Brass NPT male threadSupplied with a 35’ control cable

GeneratorWeight - 30 lbs.

Installation NotesFor optimum performance, the steam generator should be mounted as close as possible to the steam room. If needed, the steam pipe may be up to 50’ long.Steam Generators should be accessible for service.Do NOT install near flammable material such as paints, thinners, gasoline, etc. Steam generators must NOT be installed outdoors, in moist, humid areas, in areas prone to freezing, or extreme heat such as an unventilated attic. To do so will void the warranty.Steamhead to be mounted 12" to 18" above floor or 6" above rim of tub and as far from the seating area as possible.

Service AccessMinimum: 21" W x 18" D x 22" H (28" W with Auto Drain)

05/17 Pub. No. 234-B

Steam Generator Models: SMP-5, SMP-7 and SMP-10

- 1 -

Steam Generator Speci�cation Chart

5

7.5

10

100

250

450

240/1/21208/1/24240/1/31208/1/36240/1/42208/1/48

303040505060

ProductNumber

KWRating

Max. Cu. Ft.Range*

Volts/Phase/Max. Amps

LineFuse

15" x 6" x 15.5"

DimensionsL x W x H

SMP-5SMP-5-208

SMP-7SMP-7-208

SMP-10SMP-10-208

* Refer to sizing guidelines to accurately determine the proper size generator for the installation. 90°C copper wire is required for generator connection. Installation shall be in accordance with NEC and local electrical

codes.

®

Models: SMP-5, SMP-7 and SMP-10

Page 2: Features 5,7...Limited lifetime warranty - 2-year in home labor warranty where available Proportional Steam Microprocessor based diagnostics and LED indication Stainless Steel Tank

15½"

7⅝"

9⅛"

*15" *6"

12⅛"

14"

3" max

Mounting Holes

Knockouts forControl Cables

¾" Steam Outlet

Water Inlet ⅜"Compression Fitting

¾" Safety Relief Valve

Top ViewBack View

Front Access

Rear Side View

Front Side View

Top of Access Panel

Access Panel

*Add ¼" to the dimension for the louvers

1⅝"

SERNO.

NO.

SIZE IN.

MODEL

SET PSIG

CAP LBS/HR

2⅜"

2¾"

2⅞"

Speci�cations

05/17 Pub. No. 234-B

Dimensional Drawing Models: SMP-5, SMP-7 and SMP-10

- 2 -

East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746

West Coast Office: Tel: 800-355-6478 • Fax: 661-940-1617 ®

Page 3: Features 5,7...Limited lifetime warranty - 2-year in home labor warranty where available Proportional Steam Microprocessor based diagnostics and LED indication Stainless Steel Tank

Optional AutoDrain Valve

Model AD-900

Water Inlet⅜" Compression

Fitting

¾" Safety Relief Valve

¾" SteamOutlet

Knockouts forElectrical Supply Line

Knockouts forControl Cable

01/17 Pub. No. 230-A- 1 -

Install Uprightand Level

C US®

IMPORTANT: The warranty of this product is voided if it is used in a commercial application or for anything other than a residential steambath installation. All electrical connections must be performed by a licensed electrician in accordance with Local and National Electric Codes.

Electrical Installation Instructions

Steambath Generators Models: SMP-5, SMP-7 and SMP-10

NOTE: A “TSC” series control is required to operate the "SMP" generator.The Steamist “SMP” Generator operates with ONLY the “TSC” series controls mounted inside and an optional TSX control located outside the steamroom. It’s small enough in size to be tucked away using very little space in a vanity, closet, or base-ment, but large enough to provide steam for most residential baths.The Steamist “SMP” Steambath Generator comes factory assembled, carefully wired and tested.

1. Pre-Installationa) Proper electrical supply (208 or 240 Volt): See rating

label on Steam Generator and Chart on page 4. Determine proper size of wire, voltage, amperage, and phase for the Steam Generator. 90°C copper wire is required for generator connection.

b) In-line fuse/circuit breaker required: Fuse/circuit breaker to be installed must be sized in accordance with chart on back page. Do NOT install a GFI (Ground Fault Interrupter) to this equipment (per article 210-8 in the National Electric Code).

c) Route power supply cable to the location where the Steam Generator will be installed (before walls are closed).

2. Electrical Rough-ina) Route appropriate power cable to the location the Steam

Generator will be installed. If receptacle is desired, mount the box for the receptacle near the location of the Steam Generator.

NOTE: The plug and receptacle require a rating of no less than 250V and proper amperage. Refer to chart on page 4 for amperage rating.

After the walls are complete, the Steam Generator and Control can be wired.

3. Steam Generator Electrical Installation WARNING: All power to the Steam Generator must be turned off.

a) Remove the two screws holding the electrical access cover and remove cover.

b) Locate the supply line knockout. Mount proper strain relief into knockout hole.

c) Strip back power cable’s outer insulation jacket eight inches and insert into Steam Generator. Strip back insulation ½" from the three (3) incom-ing wires (two power and one ground).

d) Insert ground wire into grounding lug located on the right side of the electrical compartment and secure.

CAUTION: Be sure the ground wire does not come in contact with a live electrical part.

e) Locate the terminal block in the upper portion of the electrical compartment. Insert power wires into the power lugs on the front of the terminal block and secure.

4. Optional Auto Drain Valve Connection a) Open knockout for Auto Drain Valve conduit

connection.b) Route flexible conduit from valve to knockout and

secure. c) Connect two wires from valve to the auto DRAIN

connection J11 on the printed circuit board (see Figure 2).

Figure 1 - Steam Generator

Important: Locate Publication No. 199 “Steam Bath Important Safety Instructions”. This publication includes a Warning label that the contractor must install on the wall near the entrance to the steam room in a highly visible location. This label and its additional safety information are packaged with the generator in the envelope containing the installation instructions. If it is lost or missing contact Steamist (201-933-0700) for a replacement Publication No. 199. This publica-tion along with all documents must be left with the owner.

!

®

Page 4: Features 5,7...Limited lifetime warranty - 2-year in home labor warranty where available Proportional Steam Microprocessor based diagnostics and LED indication Stainless Steel Tank

01/17 Pub. No. 230-A- 2 -

Optional Auto Drainshown installed

Modular JacksKnockouts forControl Cables PC Board 208/240 Volt incoming

power connections

Knockouts forControl Cables

Knockouts for electricalsupply line

WaterLevelProbe

Water Inlet⅜" CompressionFitting

Optional AutoDrain Connection

¾" SteamOutlet

SafetyReliefValve

Electrical Installation Instructions

Models: SMP-5, SMP-7 and SMP-10

Figure 2 - Internal Electrical Connections

The Steam Generator is installed in an upright position.The proper sized 90°C copper wire and circuit breaker have been used.The circuit breaker is NOT a GFI (Ground Fault Interrupter) type.The Steam Generator is properly grounded.The circuit breaker or disconnect switch is on.Water supply is open to the Steam Generator.

Checklist

Before starting, insure that the conditions of the following checklist have been met:The proper size Steam Generator has been selected by using the sizing page in the “Full Line Brochure,” “Pricing Guide,” or “The Generator Sizing Guide” in the Residen-tial Systems/Steambath Product Information section of the Steamist website - www.steamist.com.CAUTION: An improperly sized Steam Generator will NOT produce the amount of steam necessary to reach selected temperature.The proper voltage Steam Generator has been selected (i.e., 208V or 240V). A 208V Generator operating on 240V will damage the heating element, and a 240V Generator operating on 208V will result in a 25% loss of power.

Test button

Troubleshooting LED’s

Page 5: Features 5,7...Limited lifetime warranty - 2-year in home labor warranty where available Proportional Steam Microprocessor based diagnostics and LED indication Stainless Steel Tank

01/17 Pub. No. 230-A- 3 -

The Electrical Instructions must be given to the homeowner for future use.

NOTE: Unit must be wired with 90°C copper wire in a suitable raceway, or, if local codes allow, provide twist lock plug on a 90°C copper wire cord from genera-tor to a 250V 2-pole, 3-wire grounding receptacle (amperage rating as required).

IMPORTANT: Run the Control Cable through a ¾" conduit. Remove protective cap when making the final connection to Control.

TSX Auxilary Outside Control

Electrical Installation Instructions

Figure 4 - Typical Installation

Models: SMP-5, SMP-7 and SMP-10

STOP21

SHOWERSTEAMSHOWERSTEAM1 1 2 2

9:31IM

Inside InstallationControl should be mounted four

feet from the floor. Select a location convenient to the

bather but not in a direct line of Shower or Body Sprays and not directly above the Steamhead.

TSC Series ControlControl MUST be installed inside

the Steam room.

Control CableRoute from

Control to Steam Generator in a

¾" conduit.

Page 6: Features 5,7...Limited lifetime warranty - 2-year in home labor warranty where available Proportional Steam Microprocessor based diagnostics and LED indication Stainless Steel Tank

- 4 -01/17 Pub. No. 230-A

WaterLevelProbe

GNTANK

OptionalAuto Drain

Valve

WaterSolenoid

Valve

208-240VACSupply Connection

L1

L2

GND

Specification ChartModel

No.Max. Cu. Ft.

For Area Up To KW Volt Phase AmpsBreaker

Size

SMP-7 250 7.5 240208

11

3136

4050

Electrical Installation Instructions

Figure 5 - Wiring Diagram Models: SMP-5, SMP-7 and SMP-10

90°C copper wire is required for generator connection. Installation shall be in accordance with appli-cable electrical codes.

East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746

West Coast Office: Tel: 800-355-6478 • Fax: 661-940-1617 ®

DRAIN

DS13

STEAMIST, INC.ASSEMBLY NO. 007-3426

0.5A 250VAC

J11

F3

J9

J10

J12

SW2F1 F2

RH2_L2

RH3_L2

RH2_L1

RH3_L1

DS5

DS6

DS7

DS8

S1

TEST

0.8A 250VAC

H2O LO SEN

H2O HI SEN

DRAIN

WTR1

SYSFAIL

TEST

SYSOK

COMFAIL

DS3

DS1

DS2

DS10

DS11

0.5A 250VAC

J2

J1FILL1

EARTH

EARTH

J5

J6

J7

J8OPTIONS

5 6 7 81 2 3 4

SMP-5 100 5 240208

SMP-10 450 10 240208

11

11

4248

2124

3030

5060

GRAY

WHITE

BLU

EBL

UE

GR

AY

WH

ITE

Page 7: Features 5,7...Limited lifetime warranty - 2-year in home labor warranty where available Proportional Steam Microprocessor based diagnostics and LED indication Stainless Steel Tank

Optional AutoDrain Valve

Model AD-900

Water Inlet⅜" Compression

Fitting

¾" Safety Relief Valve

¾" SteamOutlet

Knockouts forElectrical Supply Line

Knockouts forControl Cable

Install Uprightand Level

IMPORTANT: The warranty of this product is voided if it is used in a commercial application or for anything other than a residential steambath installation.

Plumbing Installation Instructions

Steambath Generator Models: SMP-5, SMP-7, SMP-10, SMP-12 and SMP-15

The Steamist “SMP” Generator comes factory assembled, carefully wired and tested.WARNING: All electrical power should be turned OFF when working with Steam Generator.IMPORTANT: The Plumbing Installation must conform to local and national codes.

1. Pre-Installationa) Be sure that the proper size Steam Generator has been

selected by using the sizing page in the “Full Line Brochure,” “Pricing Guide,” “The Generator Sizing Guide,” “Architectural Guidelines,” or in the Residential Systems/Steambath Product Information section of the Steamist website - www.steamist.com.

CAUTION: An improperly sized Steam Generator may NOT produce the amount of steam necessary to reach selected temperature.

b) For optimum performance, the Steam Generator should be located as close as possible to the Steamroom, Shower or tub enclosure using a ¾” copper pipe (1/2” copper pipe is also acceptable, but not preferred). If the steam pipe exceeds ten feet, it should be insulated using appropriate pipe insulation rated for a minimum of 212º F. Maximum steam pipe distance should not exceed a total of fifty linear feet. Refer to Installation Suggestions on page 4.

CAUTION: Do NOT install near flammable material such as paints, thinners, gasoline, etc. CAUTION: Steam generators must NOT be installed outdoors, in moist, humid areas, in areas prone to freezing, or extreme heat such as an unventilated attic. To do so will void the warranty.

c) The steam line and safety valve reach a temperature of 212°F during operation and should be appropriately protected to prevent personal injury by accidental contact.

2. Plumbing Rough-in Plumbing rough-in is required for the water supply and

steam line; this should be completed before the walls are closed. For operation, the “SMP” Steam Generator requires a ⅜" O.D. copper tubing to the fitting on the generator for water inlet and a ¾" copper or brass pipe for steam outlet.

NOTE: Safety Valve should be connected to a minimum ¾" indirect waste or as required by local plumbing codes. In the unlikely event this valve should open, the discharge must be directed to prevent damage to the home.

a) Water Inlet - Rough in a water line, 120 PSI max, to the hot or cold supply. A shut off valve with a 3/8” connection to the steam generator is to be provided at the generator location (see Figure 4 on page 3).

b) Steam Outlet - Rough in the steam line using a ¾" copper or brass pipe; do NOT use black iron or galvanized pipe; it will rust and discolor the wall of the steambath. Do NOT use any plastic type pipe or fittings. The steamhead location should be 12” to 18" above the shower floor or 6" above the rim of the bathtub, as far from the seating area as possible.

CAUTION: No shutoff valve can be installed in the steam line. Do NOT create traps or valleys in this line which would trap condensation and block the flow of steam. The steam pipe should be pitched allowing condensation to run back toward the Steam Generator (preferred), or toward the steamhead.

Figure 1 - Steam Generator

C US®

01/17 Pub. No. 232-A- 1 -

Important: Locate Publication No. 199 “Steam Bath Important Safety Instructions”. This publication includes a Warning label that the contractor must install on the wall near the entrance to the steam room in a highly visible location. This label and its additional safety information are packaged with the generator in the envelope containing the installation instructions. If it is lost or missing contact Steamist (201-933-0700) for a replacement Publication No. 199. This publica-tion along with all documents must be left with the owner.

!

®

Page 8: Features 5,7...Limited lifetime warranty - 2-year in home labor warranty where available Proportional Steam Microprocessor based diagnostics and LED indication Stainless Steel Tank

SteamGenerator

Shutoff Valve

Electric Water Solenoid Valve Cold Incoming

Water Supply120 PSI Max

Tank

Steam Line

IMPORTANT: Install steamhead 12” to 18" above the shower floor or 6" above

the rim of the bathtub.

Union(Required)

Water Level Probe

Pressure Safety ValveConnect to indirect waste or as

required by local codes.

Optional Auto Drain ValveConnect to indirect waste or as

required by local codes.

Plumbing Installation Instructions

3. Steam Generator InstallationThe Steam Generator should be mounted in a location conve-nient for hook-up and service by the plumber and electrician.CAUTION: The Steam Generator is designed to be used ONLY in an upright and level position; to do otherwise would damage the unit and void the warranty.

a) The Steam Generator can be mounted to a wall or set on the floor. However, the unit must be secured. To secure the unit to a vertical wall, loosen the two screws holding the electrical access cover, remove cover (see Figure 1). Located inside the cabinet near the top left and right corners are mounting holes. Place top cover back and secure.

Figure 2 - Plumbing Diagram

Installation Instructions Models: SMP-5, SMP-7, SMP-10, SMP12 and SMP-15

01/17 Pub. No. 232-A- 2 -

b) Connect the ⅜" water inlet to a shut off valve as described in Section 2.a. The valve must be kept in an open position during normal operation. In an area where water hammer is a problem install a water hammer arrestor in the line. Refer to Figure 2.

IMPORTANT: Do NOT use a “saddle valve” or piercing type valve for water connection.

c) Connect the steam line from rough-in location described in Section 2 to the ¾" nipple on the Steam Generator using a union.

4. Optional Auto DrainIf an Optional AutoDrain Valve (Model# AD-900) is installed,please make sure to release the metal lever, to allow the valve to close, while product is in use, see Pub# 270.

Page 9: Features 5,7...Limited lifetime warranty - 2-year in home labor warranty where available Proportional Steam Microprocessor based diagnostics and LED indication Stainless Steel Tank

TSX-220 Auxilary Outside Control

Steam Outlet Pipe - Use a ¾" Copper or Brass pipe.CAUTION: Do NOT install a shutoff valve on the steam outlet pipe. Do NOT create traps or valleys in this line which would prevent the flow of steam. The steam outlet pipe should be pitched toward the Steam Generator (preferred), allowing condensation to run back into the Steam Generator or toward the steamhead. If the steam pipe exceeds ten feet, use an appropriate pipe insulation rated for a minimum of 212°F.

TSC model control MUST be installed inside the

Steam room.

Steamhead InstallationSteamhead should be mounted 12” to 18" above the finished floor or 6" above the rim of the tub as far from

the bather as possible.

Safety ValveConnect ¾" pipe to an

indirect waste or as required by local codes.

Union Required

Auto Drain Ready½" Capped Line

The Plumbing Instructions must be given to the homeowner for future use.

⅜" Shutoff ValveKeep in open

position during normal operation.

Connect to Hot or Cold water supply

Plumbing Installation Instructions

Figure 4 - Typical Installation Models: SMP-5, SMP-7, SMP-10, SM-12 and SMP-15

01/17 Pub. No. 232-A- 3 -

STOP2121TIME

TEMPIM

STOP

Page 10: Features 5,7...Limited lifetime warranty - 2-year in home labor warranty where available Proportional Steam Microprocessor based diagnostics and LED indication Stainless Steel Tank

A

B

C

DAccess

Plumbing Installation Instructions

Access Requirements Models: SMP-5, SMP-7, SMP-10, SMP-12 and SMP-15

01/17 Pub. No. 232-A- 4 -

Select a location for mounting the Steam Generator that is accessible for installation and service. The access requirement indicates the minimum space for convenient access to Steam Generator.CAUTION: All models must be installed INDOORS, in a DRY, NON-FREEZING location away from flammable materials such as: Gasoline, Paints, Thinners, Etc.IMPORTANT: Steam Generator must be installed upright and level. The serial number info should be visible and the Steam Generator should be accessible for service.

Figure 5

Installation Suggestions

®

*Alternate Attic Location(See CAUTION below)

*Alternate Basement Location(See CAUTION below)

STOP2121TIME

TEMPIM

STOP

VanityLocation

Closet Location

*CAUTION: Steam generators must NOT be installed outdoors, in moist, humid areas, in areas prone to freezing, or extreme heat such as an unventilated attic. To do so will void the warranty.

East Coast Office: 25 E. Union Ave., East Rutherford, NJ 07073 • Tel: 800-577-6478 • Fax: 201-933-0746

West Coast Office: Tel: 800-355-6478 • Fax: 661-940-1617

Access for Service Chart (See Figure 5)Model Number A

With AutoDrainB

Without AutoDrain

SMP-12 and SMP-15

SMP-5, SMP-7 and SMP-10

C D

22” 18”

22”

28” 21”

35” 28” 18”Optional AutoDrainValve Model AD-900