feasibility of x-ray cherenkov diffraction radiation for beam diagnostics of linear accelerators

18
Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators A.S. Konkov, A.P. Potylitsyn, A.S. Gogolev, Tomsk Polytechnic University P.V. Karataev , JAI at Royal Holloway, University of London

Upload: katen

Post on 20-Mar-2016

58 views

Category:

Documents


0 download

DESCRIPTION

Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators. A.S. Konkov , A.P. Potylitsyn , A.S. Gogolev , Tomsk Polytechnic University P.V. Karataev , JAI at Royal Holloway, University of London. R ( t ). O. z ( t ). Introduction. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Feasibility of X-ray Cherenkov Diffraction radiation for beam

diagnostics of linear acceleratorsA.S. Konkov, A.P. Potylitsyn, A.S. Gogolev, Tomsk Polytechnic

University

P.V. Karataev, JAI at Royal Holloway, University of London

Page 2: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Introduction

R(t)

O z(t) ( ) 1cosθ

( ) βc n tR t

z t vt n

Cherenkov Radiation is generated whenever the charged particle velocity is larger than the phase velocity of light

Is there Cherenkov radiation in X-ray region?

Page 3: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Carbon Dielectric Permittivity

−δ

η K-edge

Page 4: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Geometry

X-Ray ChTR

X-Ray ChDR

Page 5: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Theoretical ApproachThe theoretical approach is based on the method of polarization currents. For a non-magnetic medium the density of the polarization currents in a right hand side of the Maxwell’s equations

where conductivity is

The field of the Polarization Radiation (PR) emitted by medium atoms excited (polarized) by the external field of the passing particle moving rectilinearly and with constant velocity in a substance (or in its vicinity) can be represented as a solution of Maxwell equations

Page 6: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

X-Ray Cherenkov Transition Radiation

http://ibic2013.org/prepress/html/sessi0n.htm

WEPF36

Page 7: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Intensity vs observation angle θ and thickness d

γ = 240ћω = 284 eVα = 0φ = π

Page 8: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Intensity vs observation angle θ and thickness d

γ = 10ћω = 284 eVα = 0φ = π

Page 9: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Oblique Incidence

γ = 24, ћω = 284 eV, d = 5 μm, α = 5°, φ = π

ChR

TR

Page 10: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

X-Ray Cherenkov Diffraction Radiation

Page 11: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Intensity vs observation angle θ and thickness dγ = 240ћω = 284 eVα = 0h = 1 μmφ = π

Page 12: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Intensity vs observation angle θ and thickness dγ = 10ћω = 284 eVα = 0h = 0.1 μmφ = π

Page 13: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Intensity vs observation angle θ for different photon energies

γ = 240d = 5 μmα = 0h = 1 μmφ = π

Page 14: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Intensity vs observation angle θ for different electron energies

d = 5 μmα = 0h = 0.1 μmφ = π

Page 15: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Oblique Incidence

γ = 240, ћω = 284 eV, d = 5 μm, α = 3°, h = 1 μm, φ = π

ChRDR

Page 16: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Intensity vs observation angle θ for different incidence angles

γ = 240 ћω = 284 eV d = 5 μm h = 1 μmφ = π

Page 17: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Conclusion

The model based on Polarization Current method agrees with other models for given beam parameters and approximations;

The Cherenkov Radiation is highly monochromatic in X-ray wavelength range;

The Angular distribution can be used to measure the beam energy with 10% accuracy;

In the energy range of γ > 100 the Polarization Radiation can be used to determine the beam angular divergence;

A real application for beam diagnostics is yet to be estimated!

Page 18: Feasibility of X-ray Cherenkov Diffraction radiation for beam diagnostics of linear accelerators

Thank you for your attention!