fanuc fault codes ba 400
TRANSCRIPT
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 1 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1000 MOVE Z-AXIS AS DOWN AS POSSBLE
Cause: The brake test of Z-axis during teststop was not successful
Effect:
Remedy:
Note:
FM 1001 Z-AXIS BRAKE TEST FAILED
Cause: The brake test of Z-axis during teststop was not successful
Effect:
Remedy:
Note:
FM 1002 CNC NOT READY "F1.7"
Cause: The NC is not ready
Effect: The Machine can not be turned ON
Remedy: See detailed Alarmlist (also Fanuc)
Note:
FM 1003 BATTERY STATUS LOW
Cause: The Battery status is low
Effect: Non
Remedy: While machine is turned ON replace battery
Note: DO NOT TURN OFF MACHINE - LOOSE REFERENCE POINT
FM 1004 FUSE TRIPPED "F10"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 2 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1005 FUSE TRIPPED "F11"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM 1006 FUSE TRIPPED "F12"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM 1007 FUSE TRIPPED "F36"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM 1008 FUSE TRIPPED "F40"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 3 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1009 FUSE TRIPPED "F44"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM 1010 FUSE TRIPPED "F32"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM 1011 FUSE TRIPPED "FA10"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM 1012 FUSE TRIPPED "FA1"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 4 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1013 FUSE TRIPPED "FA8"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM 1014 FUSE TRIPPED "FA12"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM 1015 FUSE TRIPPED "FA16"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM 1016 FUSE TRIPPED "FA32"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 5 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1017 FUSE TRIPPED "FA34"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM 1018 FUSE TRIPPED "FA36"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM 1019 FUSE TRIPPED "FA40"
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM 1020 FUSE TRIPPED
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy: Insert fuse
Check circuit / input
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 6 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1021 MAX END POSITION AXES ""
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1022 OVLD C/LUBE "ZS-Q12"
Cause: Over-current trigger for lubrication has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check the circuits of the lubrication unit (motor may be blocked)
Switch the trigger into the circuit
Note:
FM 1023 OVLD COOLANT "S271"
Cause: Over-current trigger for coolant system has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check currents
Switch the trigger into the circuit
Note: Compact system: all triggers for coolant. Systems with additional container (ASI): auxiliary drives except for coolant pumps (external/internal cooling)
FM 1024 OVLD HYDRAULIC "HY-Q10"
Cause: Over-current trigger for hydraulic system has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check the circuits of the hydraulic unit
Switch the trigger into the circuit
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 7 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1025 OVLD HEAT EXCH "Q14/16"
Cause: Over-current trigger for cooling system has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1026 OVLD EXHAUSTSY "Q18"
Cause: Over-current trigger for air exhaust system has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check the circuits
Switch the trigger into the circuit
Note:
FM 1027 NO 24V FROM SW "S270"
Cause: Coolant: 24 V power supply (outputs) not reporting
Effect: Feed stop / spindle stop
Start lock
Remedy: Check 24-V power supply
Note: Signal is only available if a coolant is turned on. Switch cabinet on the KLM
FM 1029 SERVO NOT RDY "SA#2"
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 8 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1030 MAIN PWR MODUL NOT RDY "CX3:3"
Cause: Drive train: supply/ monitoring module 1 not reporting ready for operation
Effect: Feed stop / spindle stop
Start lock
Remedy: Emergency STOP + RESET, then delete error(s)
Note: Look for other alarms
FM 1031 MAIN PWR MODUL NOT RDY
Cause: Drive train: supply/ monitoring module 2 not reporting ready for operation
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1032 ALARM SPINDLE 1 "ALMA"
Cause: Fanuc Alarm Spindle 1 occured
Effect: Feed stop / spindle stop
Start lock
Remedy: RESET or turn OFF and ON the machine
Note: For further information see Fanuc "Maintance manual"
FM 1033 ALARM SPINDLE 2 "ALMB"
Cause: Fanuc Alarm Spindle 2 occured
Effect: Feed stop / spindle stop
Start lock
Remedy: RESET or turn OFF and ON the machine
Note: For further information see Fanuc "Maintance manual"
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 9 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1034 SERVO NOT RDY "SA"
Cause: The Servo Modul is not ready
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1035 POLE DETECT.SPDL NOT PROCESSED
Cause: Pole detection on synchron spindle is not processed
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1036 POLE DETECT.AXIS NOT PROCESSED
Cause: Pole detection on ETEL axis is not processed
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1037 BKW COOLER NOT RDY "S150"
Cause: Cooling unit not ready for operation
Effect: Feed stop / spindle stop
Start lock
Remedy: JOG + error delete key
Note: Note any additional messages (check filling level of water)
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 10 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1038 ELEC.CAB-COOLER NOT RDY
Cause: Electrical cabinet cooler not ready for operation
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1039 HYDR OIL MIN LEVEL "HY-B141"
Cause: Hydraulics: oil level low
Effect: Feed stop / spindle stop
Start lock
Remedy: Fill up hydraulic oil
Note:
FM 1040 NO SYSTM HYDR PRS "HY-B130"
Cause: Hydraulics: system pressure monitoring has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check hydraulics
Note:
FM 1041 HYDR RETURN FILTR DIRTY
Cause: Hydraulics: return filter dirty
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 11 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1042 OVRHEATED HYDR TEMP "HY-B132"
Cause: Hydraulics: temperature monitoring has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Cool off hydraulics, find out reason for heating up
Note:
FM 1043 HYD FILTER DIRTY
Cause: Hydraulics: filter dirty
Effect: Feed stop / spindle stop
Start lock
Remedy: Replace filter
Note:
FM 1044 MAGAZIN BALANCE N.OK "S416/417"
Cause: Magazine has engaged out of neutral position
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1045 TANKLOAD PRS NOT REACHED
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 12 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1046 NO SYSTM PNEUM PRS "PN-B122"
Cause: Pneumatic system pressure has dropped
Effect: Feed stop / spindle stop
Start lock
Remedy: Check air supply
Check pressure switch
Note:
FM 1048 MAINTENANCE DOOR NOT CLOSED
Cause: Maintenance door is not closed
Switch from maintenance door has no respond
Effect: Feed stop / spindle stop
Start lock
Remedy: Press "DELETE FAULT MESSAGE" button
Check door switch
Note:
FM 1049 SETUP DOOR N.LOCKED "MA-7S1-4"
Cause: Interlock switch for partition wall is not locked
Effect: Feed stop / spindle stop
Start lock
Remedy: Close partition wall, check interlock switch
Note: 2-slot machines only
FM 1050 LOAD DOOR N.UNLOCKED "MA-S401"
Cause: Interlock switch for loading door is not unlocked
Effect: Feed stop / spindle stop
Start lock
Remedy: Interlock magnet feedback, loading door missing
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 13 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1051 MAG DOOR N.LOCKED "MA-S411"
Cause: Interlock switch for magazine door is not locked
Effect: Feed stop / spindle stop
Start lock
Remedy: Close magazine loading door, check lock switch of magazine loading door
Note:
FM 1052 LOAD DOOR N.OPENED "E363"
Cause: Landert drive for loading door has error upon opening
Effect: Feed stop / spindle stop
Start lock
Remedy: Check Landert/loading door
Note: No loading enable with robot operation (loading from above)
FM 1053 LOAD DOOR N.LOCKED "MA-S401"
Cause: Interlock switch for loading door is not locked
Effect: Feed stop / spindle stop
Start lock
Remedy: Check covering interlock
Note:
FM 1054 LOAD DOOR N.CALIBRATED "E364"
Cause: Landert drive for loading door is not calibrated
Effect: Feed stop / spindle stop
Start lock
Remedy: Close and open loading door with keys on control panel.
Check to ensure input door calibrated
Check Landert unit (mechanics, belt)
Note: Do not activate the counter direction directly after opening / closing; this will interrupt the calibration process in some circumstances (wait 2-3 sec.)
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 14 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1055 SAFETY SWITCH SIDE PAN
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1056 SAFETY SWITCH SIDE PAN
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1057 C/LUBE PRESSURE "ZS-B031"
Cause: Lubrication pressure of central lubrication reporting incorrect
Effect: Feed stop / spindle stop
Start lock
Remedy: Check lines and pressure switch of central lubrication
Note:
FM 1061 SP/LUBE OIL PRESS. "ZS-B033"
Cause: Grease pressure of spindle lubrication reporting wrong
Effect: Feed stop / spindle stop
Start lock
Remedy: Check lines and pressure switch for lubrication pressure in spindle lubrication
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 15 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1062 SP/LUBE PNEU.PRESS "ZS-B032"
Cause: Pneumatic pressure of spindle lubrication reporting wrong
Effect: Feed stop / spindle stop
Start lock
Remedy: Check lines and pressure switch for pneumatic pressure in spindle lubrication
Note:
FM 1064 FUSE TRIPPED
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1065 FUSE TRIPPED
Cause: Fuse has been tripped
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1072 FAULT PROG NR CONVERSION
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 16 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1073 FAULT TRANSFER PROG NR TO CNC
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1080 COOLANT MIN LEVEL "S282"
Cause: Coolant: clean water floater switch reporting MIN
Effect: Feed stop / spindle stop
Start lock
Remedy: Fill with clean water, check floater switch
Note:
FM 1081 OVERFLOW COOLANT SYSTEM "S291"
Cause: Coolant: MAX clean water floater switch for belt filter system has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check MAX clean water floater switch,
drain out clean water
Note:
FM 1082 COOLANT MAX LEVEL "S280"
Cause: Coolant: swarf conveyor floater switch reporting MAX
Effect: Feed stop / spindle stop
Start lock
Remedy: Check lifting pump and floater switch
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 17 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1083 CLEAN WATR MIN TURBO "S282"
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1084 MUDY WATR MAX TURBO "S291"
Cause: Coolant: MAX dirty water floater switch for turbo filter has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check dirty water floater switch,
drain out dirty water
Note:
FM 1085 PROGR COOLANT PRESSURE >70
Cause: Coolant pressure was programmed higher than 70 bar
Effect: Feed stop / spindle stop
Start lock
Remedy: Check NC program
#1132 < 70
Note:
FM 1086 MUDY WATR MIN TURBO "S303"
Cause: Coolant: MIN dirty water floater switch for turbo filter has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check MIN floater switch,
refill with water
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 18 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1087 GREASE LUBRICATN MIN "B153"
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1088 Q POSITIONING PMC N.FINISHED
Cause: PMC positioning of rotary axis could not finished
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1089 PAIRCHEK Q-AXIS "S070/071"
Cause: Both limit switches of Q axis reporting (raised/lowered)
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note:
FM 1090 Q-AXIS N.ON 0 DEG "S390"
Cause: Software cam does not match travel movement
Effect: Feed stop / spindle stop
Start lock
Remedy: Check soft cam(s)
Note: By authorized personnel only
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 19 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1091 Q-AXIS N.ON 180 DEG "S391"
Cause: Software cam does not match travel movement
Effect: Feed stop / spindle stop
Start lock
Remedy: Check soft cam(s)
Note: By authorized personnel only
FM 1092 Q-AXIS N.RAISED "S071"
Cause: Limit switch for swivel table not reporting raised
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note:
FM 1093 Q-AXIS N.LOCKED "S070"
Cause: Limit switch for swivel table not reporting lowered
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note:
FM 1095 Q-AXIS SIGNAL 0/180 (SOFTWARE)
Cause: Rotary table is out of software limit switches
Effect: Feed stop / spindle stop
Start lock
Remedy: Check softcam positions for rotary table
Move rotary table in singlemovement to defined position
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 20 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1096 Q-AXIS NOT ON 0 DEGREE
Cause: Rotary table is not on 0 degree
Effect: Feed stop / spindle stop
Start lock
Remedy: Check softcam positions for rotary table 0 degree
Move rotary table in singlemovement to defined position
Note:
FM 1097 Q-AXIS NOT ON 180 DEGREE
Cause: Rotary table is not on 180 degree
Effect: Feed stop / spindle stop
Start lock
Remedy: Check softcam positions for rotary table 180 degree
Move rotary table in singlemovement to defined position
Note:
FM 1098 Q-AXIS N.IN DEFIND POSITION
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1100 PLEASE EXECUTE SAFE TEST
Cause: A teststop has to executed fter Power ON or after 24h runtime
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 21 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1101 CNC ALARM PATH 1
Cause: PMC Alarm in Path 1
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1102 CNC ALARM PATH 2
Cause: PMC Alarm in Path 2
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1103 DCS ALARM
Cause: PMC Alarm in Path Dual Check Safety
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1104 A-POSITIONING PMC N.FINISHED
Cause: PMC positioning of axis could not be finished
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 22 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1105 A-AXIS NOT RELEASED "HY-B101"
Cause: Axis lock is not released
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for A axis
Note:
FM 1106 A-AXIS NOT LOCKED "HY-B100"
Cause: Axis lock is not clamped
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for A axis
Note:
FM 1107 A-AXIS MOTOR OVERTEMP "X380"
Cause: Axis has over temperature
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1108 A-AXIS NOT IN HOME POSITION
Cause: Axis is not in swiveling position
Effect: Feed stop / spindle stop
Start lock
Remedy: Put A axis in homeposition
Check soft cams for homeposition
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 23 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1109 A-COUNTERB.N.RELEASD "HY-B103"
Cause: Axis counterbearing lock is not released
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for A counterbearing
Note:
FM 1110 A-COUNTERB.NOT LOCKD "HY-B102"
Cause: Axis counterbearing lock is not clamped
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for A counterbearing
Note:
FM 1113 U-POSITIONING PMC N.FINISHED
Cause: PMC positioning of axis could not be finished
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1114 U-AXIS NOT RELEASED "HY-B111"
Cause: Axis lock is not released
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for U axis
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 24 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1115 U-AXIS NOT LOCKED "HY-B110"
Cause: Axis lock is not clamped
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for U axis
Note:
FM 1116 U-AXIS MOTOR OVERTEMP "X381"
Cause: Axis has over temperature
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1117 U-AXIS NOT IN HOME POSITION
Cause: Axis is not in swiveling position
Effect: Feed stop / spindle stop
Start lock
Remedy: Put A axis in homeposition
Check soft cams for homeposition
Note:
FM 1118 U-COUNTERB.N.RELEASD "HY-B113"
Cause: Axis counterbearing lock is not released
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for U counterbearing
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 25 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1119 U-COUNTERB.N.LOCKED "HY-B112"
Cause: Axis counterbearing lock is not clamped
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for U counterbearing
Note:
FM 1120 MAG POSITIONING NOT FINISHD
Cause: PMC positioning of axis could not be finished
Effect: Feed stop / spindle stop
Start lock
Remedy: Try again / if necessary Reset / machine Off-On
Note: Watch for additional NC alarms and report them to the SW customer service if necessary
FM 1121 MAG POSITION NOT FOUND
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1123 FAULT COUNTING MODE MAG
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 26 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1127 SPINDEL TOOL NOT CLMPED CORRECT
Cause: Spidle tool ist not correctly tightened
Effect: Feed stop / spindle stop
Start lock
Remedy: Tool in spindle
Check tool clamping device
Note: See operating instructions
FM 1128 SPI 1 (A/D CONV) NO SIGNAL
Cause: Analog digital converter for tool clamping device 1: no signal from Fanuc module
Effect: Feed stop / spindle stop
Start lock
Remedy: Check adapter for tool clamping device / check analog module
Note: By authorized personnel only
FM 1129 TL-CLMP SPI 1 NOT RELEASED
Cause: Tool clamping device 1: unclamping error
Effect: Feed stop / spindle stop
Start lock
Remedy: Check tool / check tool clamping device signals
Note: See operating instructions and SW diagnostics
FM 1130 SPI 3 (A/D CONV) NO SIGNAL
Cause: Analog digital converter for tool clamping device 3: no signal from Fanuc module
Effect: Feed stop / spindle stop
Start lock
Remedy: Check adapter for tool clamping device / check analog module
Note: By authorized personnel only
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 27 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1131 TL-CLMP SPI 3 NOT RELEASED
Cause: Tool clamping device 3: unclamping error
Effect: Feed stop / spindle stop
Start lock
Remedy: Check tool / check tool clamping device signals
Note: See operating instructions and SW diagnostics
FM 1133 LEAK DETECTION SP1
Cause: Spindle 1: leeking detection has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1134 LEAK DETECTION SP3
Cause: Spindle 3: leeking detection has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1136 SPI 2 (A/D CONV) NO SIGNAL
Cause: Analog digital converter for tool clamping device 2: no signal from Fanuc module
Effect: Feed stop / spindle stop
Start lock
Remedy: Check adapter for tool clamping device / check analog module
Note: By authorized personnel only
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 28 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1137 TL-CLMP SPI 2 NOT RELEASED
Cause: Tool clamping device 2: unclamping error
Effect: Feed stop / spindle stop
Start lock
Remedy: Check tool / check tool clamping device signals
Note: See operating instructions and SW diagnostics
FM 1138 SPI 4 (A/D CONV) NO SIGNAL
Cause: Analog digital converter for tool clamping device 4: no signal from Fanuc module
Effect: Feed stop / spindle stop
Start lock
Remedy: Check adapter for tool clamping device / check analog module
Note: By authorized personnel only
FM 1139 TL-CLMP SPI 4 NOT RELEASED
Cause: Tool clamping device 4: unclamping error
Effect: Feed stop / spindle stop
Start lock
Remedy: Check tool / check tool clamping device signals
Note: See operating instructions and SW diagnostics
FM 1141 LEAK DETECTION.SP2
Cause: Spindle 2: leeking detection has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 29 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1142 LEAK DETECTION.SP4
Cause: Spindle 4: leeking detection has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1144 PAIRCHK MAG SP 1 "PN-S010/011"
Cause: Both limit switches of tool magazine 1 interlock are unlocked/locked have engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1145 PAIRCHK MAG SP 2 "PN-S012/013"
Cause: Both limit switches of tool magazine 2 interlock are unlocked/locked have engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1147 PAIRCHK MAG-LOAD "PN-S042/043"
Cause: Both limit switches of loading slot interlock are unlocked/locked have engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 30 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1148 PAIRCHK MAG-LOAD 2
Cause: Both limit switches of loading slot interlock are unlocked/locked have engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1149 PAIRCHK MAG-COVR "PN-S020/021"
Cause: Both limit switches of the left magazine covering OPEN/CLOSED have engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1150 PAIRCHK MAG-CVR 2 "PN-S022/023"
Cause: Both limit switches of the right magazine covering OPEN/CLOSED have engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1151 PAIRCHK MAG-COVR
Cause: Both limit switches of the magazine forward / return have engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 31 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1152 TL POS 1 NOT UNLOCKD "PN-S010"
Cause: Limit switch tool slot 1 is not unlocked
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1153 TL POS 2 NOT UNLOCKD "PN-S012"
Cause: Limit switch tool slot 2 is not unlocked
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1154 TL POS 1 NOT LOCKD "PN-S011"
Cause: Limit switch tool slot 1 is not locked
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1155 TL POS 2 NOT LOCKD "PN-S013"
Cause: Limit switch tool slot 2 is not locked
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 32 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1156 LOAD PL. N.UNLOCKD "PN-S042"
Cause: Limit switch loading slot is not unlocked
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1157 LOAD PL.2 N.UNLOCKD
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1158 LOAD PL. N.LOCKD "PN-S043"
Cause: Limit switch loading slot is not locked
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1159 LOAD PL. 2 N.LOCKD
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 33 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1160 MAG CVR NOT OPEN "PN-S020/022"
Cause: Limit switch for magazine covering is not open
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1161 MAG CVR N.CLOSED "PN-S021/023"
Cause: Limit switch for magazine covering is not closed
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1162 MAG N. ADVANCED
Cause: Limit switch for magazine holder is not advanced
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM 1163 MAG N. RETURNED
Cause: Limit switch for magazine holder is not retracted
Effect: Feed stop / spindle stop
Start lock
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 34 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1164 TIMEOUT TOOLCHANGER
Cause: Tool change was not completed within the specified time frame
Effect: Feed stop / spindle stop
Start lock
Remedy: Move tool change to basic setting, basic setting key
Move tool change to basic setting via single movement. Check temporary storage of tool management
Note: For basic setting see the operating instructions
FM 1165 MAGAZINE LIST NOT EMPTY
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1168 NO TABLE CHOOSEN
Cause: Either Table 1 or Table 2 is selected
Effect: Feed stop / spindle stop
Start lock
Remedy: Select a table in the SW-Menue (CUSTOM)
Note: NC-PROG, F=1
FM 1169 WRONG TABLE POSITIONG
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 35 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1170 Z-AXIS NOT START POS.(-50.0)
Cause: The Z-axis is to START NC program not MIN. position (> -50 mm)
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1171 NC-START W/ INVALID PROG DATA
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1172 MOVE Y-AXIS TO WORK AREA
Cause: Dual check safty and spindle pole detection requires Y axis in working area
Effect: Feed stop / spindle stop
Start lock
Remedy: Move Y axis manual into working area
Note:
FM 1173 Y-AXIS IN COLLISION AREA
Cause: Y axis is in the malfunction area of the Q axis
Effect: Feed stop / spindle stop
Start lock
Remedy: JOG: move axis out of malfunction area (>400) AUTO: machine must be in tool change area
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 36 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1174 Z-AXIS IN COLLISION AREA
Cause: Z axis is outside the working area
Effect: Feed stop / spindle stop
Start lock
Remedy: JOG: move axis out of malfunction area (>400) AUTO: machine must be in tool change area
Note:
FM 1175 A-AXIS LOCKED IN LOAD AREA
Cause: Move command to axis in loading area
Effect: Feed stop / spindle stop
Start lock
Remedy: Check NC program
Note:
FM 1176 U-AXIS LOCKED IN LOAD AREA
Cause: Move command to axis in loading area
Effect: Feed stop / spindle stop
Start lock
Remedy: Check NC program
Note:
FM 1177 A-AXIS NO M11 PROGRAMMED
Cause: Interpolation programmed with A even though clamping monitoring of round axis is activated with M10
Effect: Feed stop / spindle stop
Start lock
Remedy: Program M11/M12
Note: M12 not possible for all machines
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 37 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1178 U-AXIS NO M11 PROGRAMMED
Cause: Interpolation programmed with U/B even though clamping monitoring of round axis is activated with M10
Effect: Feed stop / spindle stop
Start lock
Remedy: Program M11/M12
Note: M12 not possible for all machines
FM 1180 NO T-FUNCTION PROGRAMMED
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1181 TOOL NOT FOUND
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1182 SPINDLE CONTAINS A TOOL
Cause: Tool managment: To unload or load a tool into the tool magazine is only possible when the spindle is empty
Effect: Feed stop / spindle stop
Start lock
Remedy: Put all tools out of spindle into magazine
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 38 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1183 TOOL LIFE EXPIRED
Cause: If "TOOL LIFE MANGAMENT" active tool life is expired
Effect: Feed stop / spindle stop
Start lock
Remedy: Exchange tool and reset tool life in "TOOL LIFE MANGEMENT" for expiered tool
Note:
FM 1184 TOOL NUMBER OUT OF RANGE
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1185 W-POSITIONING PMC N.FINISHED
Cause: PMC positioning of axis could not be finished
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1186 W-AXIS NOT RELEASED "HY-B053"
Cause: Axis lock is not released
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for W axis
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 39 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1187 W-AXIS NOT LOCKED "HY-B052"
Cause: Axis lock is not clamped
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for W axis
Note:
FM 1188 W-AXIS MOTOR OVERTEMP "X383"
Cause: Axis has over temperature
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1189 W-AXIS NOT IN HOME POSITION
Cause: Axis is not in swiveling position
Effect: Feed stop / spindle stop
Start lock
Remedy: Put A axis in homeposition
Check soft cams for homeposition
Note:
FM 1190 W-AXIS LOCKED IN LOAD AREA
Cause: Move command to axis in loading area
Effect: Feed stop / spindle stop
Start lock
Remedy: Check NC program
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 40 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1191 W-AXIS NO M15 PROGRAMMED
Cause: Interpolation programmed with W even though clamping monitoring of round axis is activated with M13
Effect: Feed stop / spindle stop
Start lock
Remedy: Program M11/M12
Note: M12 not possible for all machines
FM 1192 FIX 1 T1 N.CLAMPED "HY-B080"
Cause: Pressure switch for clamping circuit 1 table 1 not reporting
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for clamping circuit 1 table 1
Note:
FM 1193 FIX 2 T1 N.CLAMPED "HY-B082"
Cause: Pressure switch for clamping circuit 1 table 1 not reporting
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for clamping circuit 2 table 1
Note:
FM 1194 FIX 3 T1 N.CLAMPED "HY-B"
Cause: Pressure switch for clamping circuit 1 table 1 not reporting
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for clamping circuit 3 table 1
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 41 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1195 FIX 4 T1 N.CLAMPED "HY-B"
Cause: Pressure switch for clamping circuit 1 table 1 not reporting
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for clamping circuit 4 table 1
Note:
FM 1201 PAIRCHK SETUP DOOR "S392/S396"
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1202 PAIRCHK SETUP DOOR "S394/S397"
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1203 PAIRCHK SETUP DOOR "S393/S90"
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 42 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1204 PAIRCHK SETUP DOOR "S395/S90"
Cause:
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1208 FIX 1 T2 N.CLAMPED "HY-B090"
Cause: Pressure switch for clamping circuit 1 table 2 not reporting
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for clamping circuit 1 table 2
Note:
FM 1209 FIX 2 T2 N.CLAMPED "HY-B092"
Cause: Pressure switch for clamping circuit 2 table 2 not reporting
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for clamping circuit 2 table 2
Note:
FM 1210 FIX 3 T2 N.CLAMPED "HY-B"
Cause: Pressure switch for clamping circuit 3 table 2 not reporting
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for clamping circuit 3 table 2
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 43 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1211 FIX 4 T2 N.CLAMPED "HY-B"
Cause: Pressure switch for clamping circuit 4 table 2 not reporting
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for clamping circuit 4 table 2
Note:
FM 1214 FIX 5 T1 N.CLAMPED
Cause: Pressure switch for clamping circuit 5 table 1 not reporting
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for clamping circuit 5 table 1
Note:
FM 1215 FIX 5 T2 N.CLAMPED
Cause: Pressure switch for clamping circuit 5 table 2 not reporting
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for clamping circuit 5 table 2
Note:
FM 1220 W2-POSITIONING PMC N.FINISHD
Cause: PMC positioning of axis could not be finished
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 44 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1221 W2-AXIS NOT RELEASED "HY-B053"
Cause: Axis lock is not released
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for U axis
Note:
FM 1222 W2-AXIS NOT LOCKED "HY-B052"
Cause: Axis lock is not clamped
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for U axis
Note:
FM 1223 W2-AXIS MOTOR OVERTEMP "X385"
Cause: Axis has over temperature
Effect:
Remedy:
Note:
FM 1224 W2-AXIS NOT IN HOME POSITION
Cause: Axis is not in swiveling position
Effect: Feed stop / spindle stop
Start lock
Remedy: Put A axis in homeposition
Check soft cams for homeposition
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 45 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1225 W2-AXIS NO M15 PROGRAMED
Cause: Interpolation programmed with W2 even though clamping monitoring of round axis is activated with M13
Effect: Feed stop / spindle stop
Start lock
Remedy: Program M11/M12
Note: M12 not possible for all machines
FM 1226 W2-AXIS LOCKED IN LOAD AREA
Cause: Move command to axis in loading area
Effect: Feed stop / spindle stop
Start lock
Remedy: Check NC program
Note:
FM 1230 C-POSITINING PMC N.FINISHED
Cause: PMC positioning of axis could not be finished
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1231 C-AXIS NOT RELEASED "HY-B051"
Cause: Axis lock is not released
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for U axis
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 46 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1232 C-AXIS NOT LOCKED "HY-B050"
Cause: Axis lock is not clamped
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for U axis
Note:
FM 1233 C-AXIS MOTOR OVERTEMP "X382"
Cause: Axis has over temperature
Effect:
Remedy:
Note:
FM 1234 C-AXIS NOT IN HOME POSITION
Cause: Axis is not in swiveling position
Effect: Feed stop / spindle stop
Start lock
Remedy: Put A axis in homeposition
Check soft cams for homeposition
Note:
FM 1235 C-AXIS LOCKED IN LOAD AREA
Cause: Move command to axis in loading area
Effect: Feed stop / spindle stop
Start lock
Remedy: Check NC program
Note:
FM 1236 C-AXIS NO M15 PROGRAMMED
Cause: Interpolation programmed with C/U even though clamping monitoring of round axis is activated with M10
Effect: Feed stop for all axes
Remedy: Program M11/M12
Note: M12 not possible for all machines
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 47 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1238 C2-POSITIONING PMC N.FINISHD
Cause: PMC positioning of axis could not be finished
Effect: Feed stop / spindle stop
Start lock
Remedy:
Note:
FM 1239 C2-AXIS NOT RELEASED "HY-B051"
Cause: Axis lock is not released
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for U axis
Note:
FM 1240 C2-AXIS NOT LOCKED "HY-B050"
Cause: Axis lock is not clamped
Effect: Feed stop / spindle stop
Start lock
Remedy: Check pressure and pressure switch for U axis
Note:
FM 1241 C2-AXIS MOTOR OVERTEMP "X384"
Cause: Axis has over temperature
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 48 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1242 C2-AXIS NOT IN HOME POSITION
Cause: Axis is not in swiveling position
Effect: Feed stop / spindle stop
Start lock
Remedy: Put A axis in homeposition
Check soft cams for homeposition
Note:
FM 1243 C2-AXIS LOCKED IN LOAD AREA
Cause: Move command to axis in loading area
Effect: Feed stop / spindle stop
Start lock
Remedy: Check NC program
Note:
FM 1244 C2-AXIS NO M15 PROGRAMMED
Cause: Interpolation programmed with C2 even though clamping monitoring of round axis is activated with M10
Effect: Feed stop / spindle stop
Start lock
Remedy: Program M11/M12
Note: M12 not possible for all machines
FM 1250 SPINDEL 1 NOT ORIENTATED
Cause: Spindle 1: signal for spindle set up +/- monitoring limits missing
Effect: Feed stop / spindle stop
Start lock
Remedy: Check spindle control
Note: Spindle may be blocked or moving with difficulty
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 49 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1251 SPINDEL 2 NOT ORIENTATED
Cause: Spindle 2: signal for spindle set up +/- monitoring limits missing
Effect: Feed stop / spindle stop
Start lock
Remedy: Check spindle control
Note: Spindle may be blocked or moving with difficulty
FM 1252 SPINDEL 3 NOT ORIENTATED
Cause: Spindle 3: signal for spindle set up +/- monitoring limits missing
Effect: Feed stop / spindle stop
Start lock
Remedy: Check spindle control
Note: Spindle may be blocked or moving with difficulty
FM 1253 SPINDEL 4 NOT ORIENTATED
Cause: Spindle 4: signal for spindle set up +/- monitoring limits missing
Effect: Feed stop / spindle stop
Start lock
Remedy: Check spindle control
Note: Spindle may be blocked or moving with difficulty
FM 1260 BLUM LASER NOT OK
Cause:
Effect:
Remedy:
Note:
FM 1261 TOOL 1 BROKEN
Cause:
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 50 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1262 TOOL 2 BROKEN
Cause:
Effect:
Remedy:
Note:
FM 1263 TOOL 3 BROKEN
Cause:
Effect:
Remedy:
Note:
FM 1264 TOOL 4 BROKEN
Cause:
Effect:
Remedy:
Note:
FM 1265 LEUZE LASER NOT OK
Cause:
Effect:
Remedy:
Note:
FM 1266 LEUZE LASER DIRTY
Cause:
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 51 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1280 ARTIS CHANNEL 1 NOT READY
Cause:
Effect:
Remedy:
Note:
FM 1281 ARTIS CHANNEL 2 NOT READY
Cause:
Effect:
Remedy:
Note:
FM 1282 ARTIS CHANNEL 3 NOT READY
Cause:
Effect:
Remedy:
Note:
FM 1283 ARTIS CHANNEL 4 NOT READY
Cause:
Effect:
Remedy:
Note:
FM 1284 ARTIS PROGAM NUMBER WRONG
Cause:
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 52 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1285 ARTIS PROGR.TRANSFORM.WRONG
Cause:
Effect:
Remedy:
Note:
FM 1290 FAULT MARPOSS 1
Cause:
Effect:
Remedy:
Note:
FM 1291 BATTERY ALARM MARPOSS 1
Cause:
Effect:
Remedy:
Note:
FM 1292 FAULT MARPOSS 2
Cause:
Effect:
Remedy:
Note:
FM 1293 BATTERY ALARM MARPOSS 2
Cause:
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 53 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1300 BALLUFF SYSTEM NOT READY
Cause:
Effect:
Remedy:
Note:
FM 1301 BALLUFF CODETAG 1 NOT PRESENT
Cause:
Effect:
Remedy:
Note:
FM 1302 BALLUFF CODETAG 2 NOT PRESENT
Cause:
Effect:
Remedy:
Note:
FM 1303 TOOL NOT FOR MACHINE S/N
Cause:
Effect:
Remedy:
Note:
FM 1304 TOOL AND POCKET ID MISSMATCH
Cause:
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 54 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1305 TOOL ID 1 AND ID 2 MISSMATCH
Cause:
Effect:
Remedy:
Note:
FM 1306 TOOL LENGTH DATA MISSMATCH
Cause:
Effect:
Remedy:
Note:
FM 1307 TOOL DATA OUT OF RANGE
Cause:
Effect:
Remedy:
Note:
FM 1310 MM-INCH - CHECK RESOLUTION
Cause: Milimter or inch was changed
check between SW option and Fanuc option does not match
Effect:
Remedy:
Note:
FM 1311 SET SPINDLE DIRECTION
Cause: The Spindle direction is not set
Effect: Feed stop / spindle stop
Start lock
Remedy: Set spindle direction as neccessary
Turn OFF and ON the machine
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 55 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
FM 1312 CHECK SPINDLE DIRECTION
Cause: The Spindle direction has to be checked
Effect: Feed stop / spindle stop
Start lock
Remedy: Check changed spindle direction
Note:
FM 1313 PLEASE TURN OFF-ON MACHINE
Cause: SW options were changed
Effect:
Remedy:
Note:
FM 1314 MOVE SEL AXIS MIN 1 ROTATION
Cause: During reference move selected axis minimum 1 motor rotation
Effect:
Remedy:
Note:
BM 2001 MAGZN BALANCE TRIPPED
Cause:
Effect:
Remedy:
Note:
BM 2002 C/LUBE OIL PREWARN "ZS-B120"
Cause: Oil level prewarning for lubrication unit
Effect: None
Remedy: Fill lubricant unit oil to MAX
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 56 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2003 C/LUBE MIN LEVEL "ZS-B121"
Cause: Oil level minimum for lubrication unit
Effect: Next Start lock
Remedy: Fill lubricant unit oil to MAX
Note:
BM 2004 SP/LUBE PREWRN LEVEL
Cause: Oil level prewarning for spindle lubrication unit
Effect: None
Remedy: Fill spindle lubricant unit oil to MAX
Note:
BM 2005 SP/LUBE MIN LEVEL
Cause: Oil level minimum for spindle lubrication unit
Effect: Next Start lock
Remedy: Fill spindle lubricant unit oil to MAX
Note:
BM 2006 HYDRAULIC OIL PREWRN
Cause: Hydraulics: oil minimum level
Effect: Next Start lock
Remedy: Fill oil until oil to MAX
Note:
BM 2007 HYDR RETRN FILTR DIRTY
Cause: Hydraulics: return filter dirty
Effect: Next Start lock
Remedy: Replace return filter
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 57 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2008 HYDR FILTER DIRTY "HY-B143"
Cause: Hydraulics: filter dirty
Effect: Next Start lock
Remedy: Replace filter
Note:
BM 2010 FILTR AIR PURGE DIRTY
Cause: Air purge filter for measuring system dirty
Effect:
Remedy:
Note:
BM 2011 EXHAUSTSYSTEM DIRTY
Cause: Filter for exhuast system dirty
Effect:
Remedy:
Note:
BM 2012 MTR OVLD EXHAUSTSYSTEM "Q18"
Cause: Over-current trigger for air exhaust system has engaged
Effect:
Remedy:
Note:
BM 2016 TL SP 1 CLAMPED TO SHORT
Cause: Tool clamping device 1: clamping error, too short
Effect: Feed / spindle stop
Remedy: Check tool / check tool clamping device signals
Note: See operating instructions and SW diagnostics
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 58 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2017 TL SP 1 CLAMPED TO LONG
Cause: Tool clamping device 1: clamping error, too long
Effect: Feed / spindle stop
Remedy: Tool / check tool clamping device signals / clamping jaw
Note: See operating instructions and SW diagnostics
BM 2018 TL SP 1 NOT SEATED CORRECT
Cause: Tool clamping device 1: plane surface error
Effect: Feed / spindle stop
Remedy: Check tool / check tool clamping device signals
Note: See operating instructions and SW diagnostics
BM 2020 TL SP 2 CLAMPED TO SHORT
Cause: Tool clamping device 2: clamping error, too short
Effect: Feed / spindle stop
Remedy: Check tool / check tool clamping device signals
Note: See operating instructions and SW diagnostics
BM 2021 TL SP 2 CLAMPED TO LONG
Cause: Tool clamping device 2: clamping error, too long
Effect: Feed / spindle stop
Remedy: Tool / check tool clamping device signals / clamping jaw
Note: See operating instructions and SW diagnostics
BM 2022 TL SP 2 NOT SEATED CORRECT
Cause: Tool clamping device 2: error, no plane surface
Effect: Feed / spindle stop
Remedy: Check tool / check tool clamping device signals
Note: See operating instructions and SW diagnostics
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 59 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2024 MAGZIN NOT LOCKED "PN-S011/013"
Cause: Limit switch tool slot 1/2 is not locked
Effect: Tool change will not be performed any more
Remedy: Check proximity switch
Note: See operating instructions and SW diagnostics
BM 2025 NO ENABLE TURN MAGAZINE
Cause:
Effect:
Remedy:
Note:
BM 2028 COOLNT TEMP NOT REACHED
Cause:
Effect:
Remedy:
Note:
BM 2029 FAULT COOLNT HEATR "S260"
Cause:
Effect:
Remedy:
Note:
BM 2030 MIN LEVEL BKW COOLER "S151"
Cause: MIN coolant for BKW cooler
Effect: Start lock
Remedy: Fill with coolant to MAX
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 60 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2031 OVRLOAD COOLANT "S271"
Cause: Over-current trigger for coolant system has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check currents
Switch the trigger into the circuit
Note: Compact system: all triggers for coolant. Systems with additional container (ASI): auxiliary drives except for coolant pumps (external/internal cooling)
BM 2032 OVRLOAD CHIPCNV "S272"
Cause: Over-current trigger for chipconveyor has engaged
Effect: Feed stop / spindle stop
Start lock
Remedy: Check currents
Switch the trigger into the circuit
Note:
BM 2033 DUBBEL FILTER DIRTY "S290"
Cause: Coolant: double filter dirty
Effect: Start lock
Remedy: Switch / replace filter
Note:
BM 2034 PAPER BAND FINISHED "S293"
Cause: Coolant: fleece end
Effect: Start lock
Remedy: Replace paper roll, check switch on the roll
Note:
BM 2035 RUN TIME PAPER BAND EXCEEDED
Cause: Coolant: fleece drive runtime monitoring
Effect: Start lock
Remedy: Check switch on belt drive, belt drive
Note: Intended to prevent unnecessary use of paper
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 61 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2036 PRES SW TURBOFILTR "S291"
Cause: Coolant: error in turbo filter system pressure switch
Effect: Start lock
Remedy: Pressure switch reporting too long (> 15 sec.) during cleaning
Note: Clean turbo filter
BM 2037 PRES SW.TURBOFILTR ACCUMULATED
Cause:
Effect:
Remedy:
Note:
BM 2038 COOLANT MIN PREWRN "S273"
Cause: Coolant: floater switch prewarning for belt filter system minimum
Effect: Start lock
Remedy: Check floater switch,
refill with water
Note: The message can be eliminated by the next end of program with the error delete key.
BM 2039 MUD WATR PREWARN TURBO "S273"
Cause: Coolant: MIN dirty water floater switch prewarning for turbo filter has engaged
Effect: Start lock
Remedy: Check MIN pre-warning floater switch,
refill with water
Note:
BM 2040 COOLANT MIN LEVEL "S282"
Cause: Coolant: floater switch minimum for belt filter system
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 62 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2041 MUDY WATR MAX TURBO "S291"
Cause:
Effect:
Remedy:
Note:
BM 2042 COOLANT MAX LEVEL "S280"
Cause: In the swarf conveyor is to much water
Effect:
Remedy:
Note:
BM 2043 TL SP 3 CLAMPED TO SHORT
Cause: Tool clamping device 3: clamping error, too short
Effect: Feed / spindle stop
Remedy: Check tool / check tool clamping device signals
Note: See operating instructions and SW diagnostics
BM 2044 TL SP 3 CLAMPED TO LONG
Cause: Tool clamping device 3: clamping error, too long
Effect: Feed / spindle stop
Remedy: Tool / check tool clamping device signals / clamping jaw
Note: See operating instructions and SW diagnostics
BM 2045 TL SP 3 NOT SEATED CORRECT
Cause: Tool clamping device 3: plane surface error
Effect: Feed / spindle stop
Remedy: Check tool / check tool clamping device signals
Note: See operating instructions and SW diagnostics
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 63 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2046 TL SP 4 CLAMPED TO SHORT
Cause: Tool clamping device 4: clamping error, too short
Effect: Feed / spindle stop
Remedy: Check tool / check tool clamping device signals
Note: See operating instructions and SW diagnostics
BM 2047 TL SP 4 CLAMPED TO LONG
Cause: Tool clamping device 4: clamping error, too long
Effect: Feed / spindle stop
Remedy: Tool / check tool clamping device signals / clamping jaw
Note: See operating instructions and SW diagnostics
BM 2048 TL SP 4 NOT SEATED CORRECT
Cause: Tool clamping device 4: error, no plane surface
Effect: Feed / spindle stop
Remedy: Check tool / check tool clamping device signals
Note: See operating instructions and SW diagnostics
BM 2050 LOAD DOOR N.UNLOCKED "MA-S401"
Cause: Interlock from loading door is not unlocked
Effect: None
Remedy: Interlock magnet feedback, loading door missing
Note:
BM 2052 LOAD DOOR NOT OPENED "E363"
Cause: Landert drive for loading door has error upon opening
Effect: None
Remedy: Check Landert/loading door
Note: No loading enable with robot operation (loading from above)
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 64 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2053 LOAD DOOR N.LOCKED "MA-S401"
Cause: Interlock from loading door is not locked
Effect: Machine not ready
Remedy: Check covering interlock
Note:
BM 2060 TOOL BROKEN ARTIS CHANNEL 1
Cause:
Effect:
Remedy:
Note:
BM 2061 TOOL MISSING ARTIS CHANNEL 1
Cause:
Effect:
Remedy:
Note:
BM 2062 TOOL WORN ARTIS CHANNEL 1
Cause:
Effect:
Remedy:
Note:
BM 2063 TOOL BROKEN ARTIS CHANNEL 2
Cause:
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 65 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2064 TOOL MISSING ARTIS CHANNEL 2
Cause:
Effect:
Remedy:
Note:
BM 2065 TOOL WORN ARTIS CHANNEL 2
Cause:
Effect:
Remedy:
Note:
BM 2066 TOOL BROKEN ARTIS CHANNEL 3
Cause:
Effect:
Remedy:
Note:
BM 2067 TOOL MISSING ARTIS CHANNEL 3
Cause:
Effect:
Remedy:
Note:
BM 2068 TOOL WORN ARTIS CHANNEL 3
Cause:
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 66 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2069 TOOL BROKEN ARTIS CHANNEL 4
Cause:
Effect:
Remedy:
Note:
BM 2070 TOOL MISSING ARTIS CHANNEL 4
Cause:
Effect:
Remedy:
Note:
BM 2071 TOOL WORN ARTIS CHANNEL 4
Cause:
Effect:
Remedy:
Note:
BM 2072 ARTIS REWORK ACTIVE
Cause:
Effect:
Remedy:
Note:
BM 2074 A-AXIS NOT IN HOME POSITION
Cause: Axis is not in swiveling position
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 67 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2075 U-AXIS NOT IN HOME POSITION
Cause: Axis is not in swiveling position
Effect:
Remedy:
Note:
BM 2076 C-AXIS NOT IN HOME POSITION
Cause: Axis is not in swiveling position
Effect:
Remedy:
Note:
BM 2077 W-AXIS NOT IN HOME POSITION
Cause: Axis is not in swiveling position
Effect:
Remedy:
Note:
BM 2078 C2-AXIS NOT IN HOME POSITION
Cause: Axis is not in swiveling position
Effect:
Remedy:
Note:
BM 2079 W2-AXIS NOT IN HOME POSITION
Cause: Axis is not in swiveling position
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 68 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2108 EMERGENCY STOP "P1-S400"
Cause: EMERGENCY STOP button pressed
Effect: Machine cannot be turned on
Remedy: Free the EMERGENCY STOP button
Check the EMERGENCY STOP circuit
Note:
BM 2111 SETUP DOOR NOT CLOSED "MA-7S1-4"
Cause:
Effect:
Remedy:
Note:
BM 2114 TLCHANGR NOT IN HOME POSITION
Cause: Tool changer not in basic setting
Effect: Feed stop, no tool change possible
Remedy: Move tool change to basic setting with basic setting key
Note: See operating instructions
BM 2115 FUSE TRIPPED
Cause:
Effect:
Remedy:
Note:
BM 2120 SINGLE STEP MODE ACTIVE
Cause: Key "Single movement" is selected
Effect: Only JOG or INCJ Mode is possible
Additional movements are allowed
Remedy: Turn off "Singlemovement"
Check key switch if working properly
Note: By authorized personnel only (JOG/REF: SK: user consent if everything is OK)
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 69 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2121 ELEC.CABINT TEMP NOT OK "A11.6"
Cause: The electrical cabinet temperature is to high
Effect: None
Remedy: Check cooler in electrical cabinet
Check adjusted temperature
Note:
BM 2122 MACHINING W/O COOLANT SYSTEM
Cause: Option Bit for "No Coolant" is selected
Effect: No coolant available
Remedy: Select with option bit the "Coolant System"
Note: See Keeprelais list or machine documentation
BM 2123 Q-AXIS NOT REFERENCED
Cause: Q axis absolute encoder not adjusted
Effect: The axis can only be moved when the axis selection key is pressed to avoid collisions
Remedy: Calibrate the Q axis measuring system
Note: By authorized personnel only (JOG/REF: SK: user consent if everything is OK)
BM 2124 X-AXIS NOT REFERENCED
Cause: X axis absolute encoder not adjusted
Effect: The axis can only be moved when the axis selection key is pressed to avoid collisions
Remedy: Calibrate the X axis measuring system
Note: By authorized personnel only
BM 2125 Y-AXIS NOT REFERENCED
Cause: Y axis absolute encoder not adjusted
Effect: The axis can only be moved when the axis selection key is pressed to avoid collisions
Remedy: Calibrate the Y axis measuring system
Note: By authorized personnel only
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 70 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2126 Z-AXIS NOT REFERENCED
Cause: Z axis absolute encoder not adjusted
Effect: The axis can only be moved when the axis selection key is pressed to avoid collisions
Remedy: Calibrate the Z axis measuring system
Note: By authorized personnel only
BM 2127 A-AXIS NOT REFERENCED
Cause: A axis absolute encoder not adjusted
Effect: The axis can only be moved with the axis selection key pressed to avoid collisions
Remedy: Calibrate the A axis measurement system
Note: By authorized personnel only
BM 2128 U-AXIS NOT REFERENCED
Cause: U axis absolute encoder not adjusted
Effect: The axis can only be moved with the axis selection key pressed to avoid collisions
Remedy: Calibrate the U axis measurement system
Note: By authorized personnel only
BM 2129 MAGAZINE NOT REFERENCED
Cause: MAG axis absolute encoder not adjusted
Effect: The axis can only be moved with the axis selection key pressed to avoid collisions
Remedy: Calibrate the MAG axis measurement system
Note: By authorized personnel only
BM 2130 C-AXIS NOT REFERENCED
Cause: C axis absolute encoder not adjusted
Effect: The axis can only be moved with the axis selection key pressed to avoid collisions
Remedy: Calibrate the C axis measurement system
Note: By authorized personnel only
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 71 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2131 W-AXIS NOT REFERENCED
Cause: W axis absolute encoder not adjusted
Effect: The axis can only be moved with the axis selection key pressed to avoid collisions
Remedy: Calibrate the W axis measurement system
Note: By authorized personnel only
BM 2132 CABINT DOOR NOT CLOSED "KE14"
Cause:
Effect:
Remedy:
Note:
BM 2133 C2-AXIS NOT REFERENCED
Cause: C2 axis absolute encoder not adjusted
Effect: The axis can only be moved with the axis selection key pressed to avoid collisions
Remedy: Calibrate the C2 axis measurement system
Note: By authorized personnel only
BM 2134 W2-AXIS NOT REFERENCED
Cause: W2 axis absolute encoder not adjusted
Effect: The axis can only be moved with the axis selection key pressed to avoid collisions
Remedy: Calibrate the W2 axis measurement system
Note: By authorized personnel only
BM 2138 MAGAZINE LOAD DOOR NOT LOCKED
Cause: Magazine loading door interlock switch closed not reporting
Effect: Magazine cannot be moved
Remedy: Close magazine loading door, check lock switch of magazine loading door
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 72 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2139 LOADG.UNIT AT TL MAGAZN ACTIVE
Cause: Loading console for tool magazine turned on
Effect: Machine control panel is locked
Remedy: Turn off tool magazine control panel
Check tool magazine control panel switch
Note:
BM 2140 LOAD/UNLOAD ONLY IN JOG MODE
Cause: Tool management: loading/unloading of tools only possible in JOG and RESET state
Effect: No loading/unloading of tools possible
Remedy: JOG - RESET- new selection
Note:
BM 2141 LOAD/UNLOAG MAGAZINE ACTIVE
Cause: Loading and unloading activated with key switch
Effect: Control panel locked
Remedy: Complete load/unload tool function
Note:
BM 2148 NO PROGRAM MODE SELECTED
Cause: No program operating mode selected (F/C)
Effect: Start lock
Remedy: Select operating program (F/C) in JOG, MSST key
Note: Please note: in F mode, the selected program (SIEMENS selection) is started, not the program from the SW program list.
BM 2149 NO PROGRAM ENTRY
Cause: SW menu: no program entry
Effect: Start lock
Remedy: Select program in SW menu
Note: See operating instructions
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 73 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2151 LOAD DOOR FAULT 1 (LANDERT)
Cause: Landert drive for loading door reporting malfunction 1 (general malfunctions)
Effect: Feed and spindle stop / start lock
Remedy: Check Landert/loading door
Note:
BM 2152 LOAD DOOR FAULT 2 (LANDERT)
Cause: Landert drive for loading door has malfunction: obstruction
Effect:
Remedy: Check loading door for ease of motion
Note:
BM 2155 SAFTY STRIP LOAD DOOR
Cause:
Effect:
Remedy:
Note:
BM 2156 LOAD DOOR NOT CLOSED
Cause: Landert drive for loading door has error upon closing
Effect: Start lock
Remedy: Check Landert/loading door
Note:
BM 2158 Q-AXIS NOT IN DEFINED POS.
Cause: Table setting not correct
Effect: No additional functions possible
Remedy: Check position of Q axis 0/180 degrees, check soft cam, cycle swivel carrier system, NCK reset if required
Note: By authorized personnel only
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 74 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2164 FIXTURE T1 NOT IN LOAD/UNL.POS
Cause: Table A is not in the unloading or loading position to open the clamping device
Effect: Clamping mechanism for table A is not releasing
Remedy: Move table A to correct position, SW menu: setup axes basic setting value
Note: Basic setting / cycle key
BM 2165 FIXTURE T1 NOT CLAMPED
Cause: Fixture table 1 not clamped
Effect: No other functions are possible
Remedy: Clamp Fixture
Note:
BM 2166 FIX 1 T1 N.CLAMPED "HY-B080"
Cause: Pressure switch for clamping circuit 1 table 1 not reporting
Effect: Clamped message not reached
Remedy: Check pressure and pressure switch for clamping circuit 1 table 1
Note:
BM 2167 FIX 2 T1 N.CLAMPED "HY-B082"
Cause: Pressure switch for clamping circuit 2 table 1 not reporting
Effect: Clamped message not reached
Remedy: Check pressure and pressure switch for clamping circuit 2 table 1
Note:
BM 2168 FIX 3 T1 N.CLAMPED "HY-B"
Cause: Pressure switch for clamping circuit 3 table 1 not reporting
Effect: Clamped message not reached
Remedy: Check pressure and pressure switch for clamping circuit 3 table 1
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 75 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2169 FIX 4 T1 N.CLAMPED "HY-B"
Cause: Pressure switch for clamping circuit 4 table 1 not reporting
Effect: Clamped message not reached
Remedy: Check pressure and pressure switch for clamping circuit 4 table 1
Note:
BM 2171 TOOL DETAIL - TOOL BLOCKED
Cause:
Effect:
Remedy:
Note:
BM 2172 TOOL DETAIL - PREWARN LIMIT
Cause:
Effect:
Remedy:
Note:
BM 2173 TOOL DETAIL -
Cause:
Effect:
Remedy:
Note:
BM 2174 TOOL DETAIL -
Cause:
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 76 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2175 TOOL DETAIL -
Cause:
Effect:
Remedy:
Note:
BM 2180 FIXTURE T2 NOT IN LOAD/UNL.POS
Cause: Table U is not in the unloading or loading position to open the clamping device
Effect: Clamping mechanism for table U is not releasing
Remedy: Move table U to correct position, SW menu: setup axes basic setting value
Note: Basic setting / cycle key
BM 2181 FIXTURE T2 NOT CLAMPED
Cause: Fixture table 2 not clamped
Effect: No other functions are possible
Remedy: Clamp Fixture
Note:
BM 2182 FIX 1 T2 N.CLAMPED "HY-B090"
Cause: Pressure switch for clamping circuit 1 table 2 not reporting
Effect: Clamped message not reached
Remedy: Check pressure and pressure switch for clamping circuit 1 table 2
Note:
BM 2183 FIX 2 T2 N.CLAMPED "HY-B092"
Cause: Pressure switch for clamping circuit 2 table 2 not reporting
Effect: Clamped message not reached
Remedy: Check pressure and pressure switch for clamping circuit 2 table 2
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 77 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2184 FIX 3 T2 N.CLAMPED "HY-B"
Cause: Pressure switch for clamping circuit 3 table 2 not reporting
Effect: Clamped message not reached
Remedy: Check pressure and pressure switch for clamping circuit 3 table 2
Note:
BM 2185 FIX 4 T2 N.CLAMPED "HY-B"
Cause: Pressure switch for clamping circuit 4 table 2 not reporting
Effect: Clamped message not reached
Remedy: Check pressure and pressure switch for clamping circuit 4 table 2
Note:
BM 2186 FAULT AIR CONTROL 1 TABLE 1
Cause:
Effect:
Remedy:
Note:
BM 2187 FAULT AIR CONTROL 1 TABLE 2
Cause:
Effect:
Remedy:
Note:
BM 2188 FAULT AIR CONTROL 2 TABLE 1
Cause:
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 78 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2189 FAULT AIR CONTROL 2 TABLE 2
Cause:
Effect:
Remedy:
Note:
BM 2190 FIX 5 T1 N.CLAMPED
Cause:
Effect:
Remedy:
Note:
BM 2191 FIX 5 T2 N.CLAMPED
Cause:
Effect:
Remedy:
Note:
BM 2196 CONFIRM R/TABLE MISSING
Cause: No acknowledgement of fitting
Effect: Table not dividing, BSTQ lamp remains dark
Remedy: Confirm acknowledgement of fitting,
check key
Note: Look for any additional messages, SPVO clamped, etc.
BM 2197 CONFIRM - NO TOOL IN MAGAZINE
Cause:
Effect:
Remedy:
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 79 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2200 MAINTENANCE REQUIRED
Cause:
Effect:
Remedy:
Note:
BM 2201 MAINTENANCE OVERTIME
Cause:
Effect:
Remedy:
Note:
BM 2212 SPI 1 TOLERANCE BAND "SPALA"
Cause:
Effect:
Remedy:
Note:
BM 2213 SPI 1 SPEED NOT ZERO "SSTA"
Cause: Spindle 1: standstill signal +/- monitoring limits missing
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
BM 2214 SPI 1 NO SPEED DETECT "SDTA"
Cause: Spindle 1: No speed detected
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 80 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2215 SPI 1 SPEED NOT REACHED "SARA"
Cause: Spindle 1: Commanded spindle speed not reached
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
BM 2216 SPI 1 NOT ORIENTED "ORARA"
Cause: Spindle 1: Spindle not orientated (M19)
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
BM 2220 SPI 2 TOLERANCE BAND "SPALB"
Cause:
Effect:
Remedy:
Note:
BM 2221 SPI 2 SPEED NOT ZERO "SSTB"
Cause: Spindle 2: standstill signal +/- monitoring limits missing
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
BM 2222 SPI 2 NO SPEED DETECT "SDTB"
Cause: Spindle 2: No speed detected
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 81 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2223 SPI 2 SPEED NOT REACHED "SARB"
Cause: Spindle 2: Commanded spindle speed not reached
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
BM 2224 SPI 2 NOT ORIENTED "ORARB"
Cause: Spindle 2: Spindle not orientated (M19)
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
BM 2227 CONFIRMATION MODE ACTIVE
Cause:
Effect:
Remedy:
Note:
BM 2228 FEED OVERRIDE TO 0%
Cause: Feed correction switch is set to 0%
Effect: Axes not moving
Remedy: Set feed correction switch to greater than 0%
Check switch
Note: Message pending. After Q axis move to single movement operating mode
BM 2229 TL-CLAMP MONITOR SWITCHED OFF
Cause: Key switch "Bridge tool clamping device" turned on
Effect: Tool clamping device monitoring is turned off; spindle limited to 150 rpm
Remedy: Turn off "Bridge tool clamping device"
Check "Bridge tool clamping device" switch
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 82 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2230 SPINDLE SPEED LIMIT TO 150 RPM
Cause: Tool clamping device reporting not completely tightened (without tool); the spindle speed is limited to 150/rpm
Effect: Spindle can only turn at max.150 rpm
Remedy: Tool in spindle
Check tool clamping device
Note: See operating instructions
BM 2231 M39 / FEED LIMIT ACTIVE
Cause:
Effect:
Remedy:
Note:
BM 2232 ROB:FUSE TRIPPED
Cause:
Effect:
Remedy:
Note:
BM 2233 ROB:
Cause:
Effect:
Remedy:
Note:
BM 2234 ROB:LOAD DOOR N.OPN "S073/072"
Cause: Robot: Additional switch for Load door is not open
Effect: No enalbe for robot
Remedy: Open load door for robot
Check additional load door switch
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 83 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2235 ROB:
Cause:
Effect:
Remedy:
Note:
BM 2236 ROBOT SAFTY GUARD NOT CLOSED
Cause: Robot: Safty guard around robot is not closed
Effect: SW- Machine will not work in load area
Remedy: Close safty guard
Check safty guard switch
Note:
BM 2237 ROBOT NOT READY
Cause: Robot: Robot is not ready for operation
Effect: Robot signals will not be transmitted
Remedy: See robot authorised personal
Note:
BM 2238 ROB:
Cause:
Effect:
Remedy:
Note:
BM 2239 ROBOT ON: CHECK PART STATUS
Cause: Robot: Robot is new selected
Effect: No enalbe for robot
Remedy: Check part status in SW-Menue
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 84 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2240 ROB: EMPTY OUT MACHINE ACTIVE
Cause: Robot: Empty out machine is selected
Effect: Machine will not proceed with production
Remedy: Turn off selection "Empty Out Machine"
Note:
BM 2241 ROB: P/CHECK L-DOOR OPEN/CLOSE
Cause: Robot: Both limit switches of load door open/close were engaged
Effect: No enalbe for robot
Remedy: Check limit switches for load door open / close
Note:
BM 2242 SPI 3 TOLERANCE BAND "SPALC"
Cause:
Effect:
Remedy:
Note:
BM 2243 SPI 3 SPEED NOT ZERO "SSTC"
Cause: Spindle 3: standstill signal +/- monitoring limits missing
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
BM 2244 SPI 3 NO SPEED DETECT "SDTC"
Cause: Spindle 3: No speed detected
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 85 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2245 SPI 3 SPEED NOT REACHED "SARC"
Cause: Spindle 3: Commanded spindle speed not reached
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
BM 2246 SPI 3 NOT ORIENTED "ORARC"
Cause: Spindle 3: Spindle not orientated (M19)
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
BM 2250 SPI 4 TOLERANCE BAND "SPALD"
Cause:
Effect:
Remedy:
Note:
BM 2251 SPI 4 SPEED NOT ZERO "SSTD"
Cause: Spindle 4: standstill signal +/- monitoring limits missing
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
BM 2252 SPI 4 NO SPEED DETECT "SDTD"
Cause: Spindle 4: No speed detected
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
FM/BM 1xxx/2xxx
Version F_02 / 13.08.2008 WeK 86 / 86
T:\Konstruktion\e_konstruktion\sw-hilfen\allgemein\original\Fanuc_BA03_Uk.dot
BM 2253 SPI 4 SPEED NOT REACHED "SARD"
Cause: Spindle 4: Commanded spindle speed not reached
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note:
BM 2254 SPI 4 NOT ORIENTED "ORARD"
Cause: Spindle 4: Spindle not orientated (M19)
Effect: Feed stop
Remedy: Check spindle control
See Fanuc Spindle Manual
Note: