f&p icon+ cpap series - infosmart brochure (pdf)

2
SPECIFICATION SHEET F&P INFOSMART™ SOFTWARE * May not be available for sale in certain countries F&P ICON™ The F&P InfoSmart™ Software has been designed to work hand in hand with the F&P ICON™. The F&P ICON™ has been designed from the outside-in to answer the strong call for a contemporary, compact CPAP that blends seamlessly into any bedroom environment, helping to break down some of the traditional resistance associated with CPAP therapy. Inside the F&P ICON™ is a comprehensive set of intelligent technologies, integrated into one stylish solution to deliver new levels of therapy, while effectively meeting your business needs. F&P InfoSmart Software provides: A patient management system for all Fisher & Paykel Healthcare Smartstick™ enabled CPAPs including: – F&P ICON™ family – SleepStyle™ CPAPs with SmartStick™ Technology Comprehensive patient reporting that offers: – Compliance data from first use – Summarized efficacy data for any 30-day period – Detailed efficacy data for any 7-day period Compatibility with multiple data communication methods: – Telephone reporting – SmartStick™ REPORT SECTIONS FEATURES FIXED AUTO SLEEPSTYLE™ CPAP MODEL 244* F&P ICON™ PREMO* SLEEPSTYLE™ CPAP MODEL 254* F&P ICON™ AUTO* F&P InfoSmart™ Software Data Reporting 1: Summary Data 2: Treatment Profile Summary 3: Compliance Summary SLEEPSTYLE™ CPAP MODELS 242* F&P ICON™ NOVO* Compliance Statistics Efficacy Statistics SensAwake™ Statistics Compliance Metric AHI Profile Pressure Profile System Leak Profile Usage and Humidity Profile CPAP Patterns of Use SensAwake™ Statistics Hypopnea Statistics Apnea Statistics Flow Limitation Statistics Pressure Profile System Leak Profile Run Time Compliance Data Efficacy Data 5: Treatment Table Summary 4: Detailed Profile More insights. Less complexity. www.fphcare.com © 2010 Fisher & Paykel Healthcare Limited F&P INFOSMART™ SOFTWARE ORDER CODE: 900ICON100 * A PC running Windows XP SP3 or later is required to run F&P InfoSmart™. For more information, please contact your local Fisher & Paykel Healthcare representative 185045370 RevA en MANUFACTURER Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348 Panmure, Auckland 1741, New Zealand Tel: +64 9 574 0100 Fax: +64 9 574 0158 Email: [email protected] Web: www.fphcare.com Australia Tel: +61 3 9879 5022 Fax: +61 3 9879 5232 Austria Tel: 0800 29 31 23 Fax: 0800 29 31 22 Benelux Tel: +31 40 216 3555 Fax: +31 40 216 3554 China Tel: +86 20 3205 3486 Fax: +86 20 3205 2132 France Tel: +33 1 6446 5201 Fax: +33 1 6446 5221 Germany Tel: +49 7181 98599 0 Fax: +49 7181 98599 66 India Tel: +91 80 4284 4000 Fax: +91 80 4123 6044 Irish Republic Tel: 1800 409 011 Italy Tel: +39 06 7839 2939 Fax: +39 06 7814 7709 Japan Tel: +81 3 3661 7205 Fax: +81 3 3661 7206 Northern Ireland Tel: 0800 132 189 Spain Tel: +34 902 013 346 Fax: +34 902 013 379 Sweden Tel: +46 8 564 76 680 Fax: +46 8 36 63 10 Switzerland Tel: 0800 83 47 63 Fax: 0800 83 47 54 Taiwan Tel: +886 2 8751 1739 Fax: +886 2 8751 5625 UK Fisher & Paykel Healthcare Ltd, Unit 16, Cordwallis Park, Clivemont Road, Maidenhead, Berkshire SL6 7BU, UK Tel: +44 1628 626 136 Fax: +44 1628 626 146 USA Tel: 1 800 446 3908 or +1 949 453 4000 Fax: +1 949 453 4001

Upload: others

Post on 12-Sep-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: F&P ICON+ CPAP Series - InfoSmart Brochure (PDF)

SPECIFICATION SHEET

F&P INFOSMART™ SOFTWARE

* May not be available for sale in certain countries

F&P ICON™

The F&P InfoSmart™ Software has been designed to work hand

in hand with the F&P ICON™. The F&P ICON™ has been designed

from the outside-in to answer the strong call for a contemporary,

compact CPAP that blends seamlessly into any bedroom

environment, helping to break down some of the traditional

resistance associated with CPAP therapy.

Inside the F&P ICON™ is a comprehensive set of intelligent

technologies, integrated into one stylish solution to deliver new

levels of therapy, while effectively meeting your business needs.

F&P InfoSmart™ Software provides:

• Apatientmanagementsystemforall Fisher & Paykel Healthcare Smartstick™ enabled CPAPs including:

– F&P ICON™ family – SleepStyle™ CPAPs with SmartStick™ Technology

• Comprehensivepatientreportingthatoffers: – Compliance data from first use – Summarized efficacy data for any 30-day period – Detailed efficacy data for any 7-day period

• Compatibilitywithmultipledatacommunicationmethods:

– Telephone reporting – SmartStick™

REPORT SECTIONS FEATURES

FIXED AUTO

SLEEPSTYLE™ CPAP MODEL 244*

F&P ICON™ PREMO*

SLEEPSTYLE™ CPAP MODEL 254*

F&P ICON™ AUTO*

F&P InfoSmart™ Software Data Reporting

1: Summary Data

2: Treatment Profile Summary

3: Compliance Summary

SLEEPSTYLE™ CPAP MODELS 242*

F&P ICON™ NOVO*

Compliance Statistics

Efficacy Statistics

SensAwake™ Statistics

Compliance Metric

AHI Profile

Pressure Profile

System Leak Profile

Usage and Humidity Profile

CPAP Patterns of Use

SensAwake™ Statistics

Hypopnea Statistics

Apnea Statistics

Flow Limitation Statistics

Pressure Profile

System Leak Profile

Run Time

Compliance Data

Efficacy Data

5: Treatment Table Summary

4: Detailed Profile

More insights. Less complexity.

www.fphcare.com© 2010 Fisher & Paykel Healthcare Limited

F&P INFOSMART™ SOFTWARE ORDER CODE: 900ICON100

* A PC running Windows XP SP3 or later is required to run F&P InfoSmart™. For more information, please contact your local Fisher & Paykel Healthcare representative

1850

4537

0 Re

vAen

MANUFACTURER Fisher & Paykel Healthcare Ltd, 15 Maurice Paykel Place, East Tamaki, Auckland 2013, PO Box 14 348 Panmure, Auckland 1741, New Zealand

Tel: +64 9 574 0100 Fax: +64 9 574 0158 Email: [email protected] Web: www.fphcare.com

Australia Tel: +61 3 9879 5022 Fax: +61 3 9879 5232 Austria Tel: 0800 29 31 23 Fax: 0800 29 31 22 Benelux Tel: +31 40 216 3555 Fax: +31 40 216 3554 China Tel: +86 20 3205 3486 Fax: +86 20 3205 2132

France Tel: +33 1 6446 5201 Fax: +33 1 6446 5221 Germany Tel: +49 7181 98599 0 Fax: +49 7181 98599 66 India Tel: +91 80 4284 4000 Fax: +91 80 4123 6044 Irish Republic Tel: 1800 409 011

Italy Tel: +39 06 7839 2939 Fax: +39 06 7814 7709 Japan Tel: +81 3 3661 7205 Fax: +81 3 3661 7206 Northern Ireland Tel: 0800 132 189 Spain Tel: +34 902 013 346 Fax: +34 902 013 379

Sweden Tel: +46 8 564 76 680 Fax: +46 8 36 63 10 Switzerland Tel: 0800 83 47 63 Fax: 0800 83 47 54 Taiwan Tel: +886 2 8751 1739 Fax: +886 2 8751 5625 UK Fisher & Paykel Healthcare Ltd,

Unit 16, Cordwallis Park, Clivemont Road, Maidenhead, Berkshire SL6 7BU, UK Tel: +44 1628 626 136 Fax: +44 1628 626 146 USA Tel: 1 800 446 3908 or +1 949 453 4000 Fax: +1 949 453 4001

Page 2: F&P ICON+ CPAP Series - InfoSmart Brochure (PDF)

Data Communication Tools

Retrieving compliance data in a timely and

efficient manner is crucial to business success

as well as improving patient outcomes.

Fisher & Paykel Healthcare provides the

following data communication tools:

• Telephonereporting:thepatientcanrelaysleepdatafromthe

Display screen of the device, which can then be verified using

F&P InfoSmart™ Software.

• SmartStick™:utilizinggenericUSBtechnologywhichprovides

large data storage capacity. The patient can mail the

SmartStick™ to you for download direct to F&P InfoSmart™.

Data Reporting

Treatment compliance and efficacy reporting is a key factor for comprehensive patient follow-up and thus therapy outcomes. F&P InfoSmart™ Software produces comprehensive charting and reporting of patient data including:

– 30 days of summary data– 7 days of detailed data– Cumulative summary data from first use

The reports are divided into five sections (refer to table on back). The first four sections of the report are detailed as follows.

SECTION 1: Summary Data The Summary Data report displays

cumulative summary data from

first use, as well as summary data

for a 30-day period.

F&P INFOSMART™ SOFTWARE | FEATURES

SECTION 4: Detailed ProfileThe Treatment Profile Summary

displays data for any 30

consecutive days and includes

summarized information on usage

and efficacy data.

SECTION 3: Compliance SummaryThe Compliance Summary displays

patterns of CPAP use for 30

consecutive days.

SECTION 2:Treatment Profile SummaryThe Treatment Profile Summary

displays data for any 30

consecutive days and includes

summarized information on usage

and efficacy data.

AHI Profile

The AHI is displayed for each night of the selected 30-day period. An effective treatment indicator of 5 is also shown on the report.

Pressure Profile

The average and 90th percentile pressure values are displayed for each night.Prescription pressures are indicated by the horizontal black lines.

System Leak Profile

The average and 90th percentile leak values are displayed for each night.

Usage and Humidity Profile

CPAP usage and humidity setting are displayed for each night.

Events

SensAwake™ activations, hypopnea, apneaand flow limited events are identified foreach night. An AHI is also displayed.

CPAP Patterns of Use

Patterns of CPAP use are established, helping to track patient sleep hygiene.

Pressure Profile

The Pressure Profile demonstrates the pressure variations throughout each night (including maximum, minimum and apnea cap pressures). Prescription pressures are indicated by the horizontal black lines.

System Leak Profile

The System Leak Profile demonstrates the leak levels throughout each night. Excessive leak is measured as 60 L/min. Leaks above this level could indicate a poor mask fit.

Run Time

CPAP usage and humidity setting are displayed for each night.

F&P INFOSMART™ SOFTWARE | REPORTS

Efficacy Statistics

The average AHI is displayed for the 30-day period. An AHI of less than 5 indicates effective treatment but if it is 5 or more this requires further investigation into the detailed data to identify the cause. The average system leak is displayed for the 30-day period in liters per minute. The leak is comprised of mask leak, bias flow and mouth leak. A leak value ≥ 60 L/min may require further investigation.

Compliance Statistics

This displays the 30-day period selected by the clinician. It shows the number of days that the device has been used for ≥ 4 hours. A number less than 21 days during a 30-day period would alert you to ≤ 70% compliance.

Compliance Metric

The compliance metric provides an automatic calculation of patient compliance, designed to meet the United States’ CMS guidelines. The compliance metric details the number of days in the reporting period that the patient used the CPAP for ≥ 4 hours and the percentage of nights that the patient used the device for ≥ 4 hours.

F&P InfoSmart™ Software is an advanced patient management software solution that is compatible with all

Fisher & Paykel Healthcare Smartstick™ enabled CPAPs. Tracking patient progress is vital for business success

and the F&P InfoSmart™ Software provides a platform for proactively monitoring patient compliance.

F&P InfoSmart™ Software offers more insights into a patient’s treatment with less complexity.