![Page 1: Fall from Tanker - Ineos · New loading facility Removed loading arm Walked along short walkway attached to tanker to return loading arm to end point Walked straight off the end of](https://reader036.vdocuments.site/reader036/viewer/2022070211/61003f665a526304d64699c1/html5/thumbnails/1.jpg)
Fall from Tanker
What can we learn?
![Page 2: Fall from Tanker - Ineos · New loading facility Removed loading arm Walked along short walkway attached to tanker to return loading arm to end point Walked straight off the end of](https://reader036.vdocuments.site/reader036/viewer/2022070211/61003f665a526304d64699c1/html5/thumbnails/2.jpg)
What Happened?
� 5th February 2009
� Operator loading bio-diesel
� New loading facility
� Removed loading arm
� Walked along short walkway attached to tanker to return loading arm to end point
� Walked straight off the end of short walkway
![Page 3: Fall from Tanker - Ineos · New loading facility Removed loading arm Walked along short walkway attached to tanker to return loading arm to end point Walked straight off the end of](https://reader036.vdocuments.site/reader036/viewer/2022070211/61003f665a526304d64699c1/html5/thumbnails/3.jpg)
What Happened?
� Fell between bottom of adjustable barrier system and side of the tanker
� Fell ~ 3m to the floor
� Broke his wrist
This could easily have been a fatality !
![Page 4: Fall from Tanker - Ineos · New loading facility Removed loading arm Walked along short walkway attached to tanker to return loading arm to end point Walked straight off the end of](https://reader036.vdocuments.site/reader036/viewer/2022070211/61003f665a526304d64699c1/html5/thumbnails/4.jpg)
What Happened?
Platform A
Direction
of Fall
![Page 5: Fall from Tanker - Ineos · New loading facility Removed loading arm Walked along short walkway attached to tanker to return loading arm to end point Walked straight off the end of](https://reader036.vdocuments.site/reader036/viewer/2022070211/61003f665a526304d64699c1/html5/thumbnails/5.jpg)
What Happened?
Fell Here
![Page 6: Fall from Tanker - Ineos · New loading facility Removed loading arm Walked along short walkway attached to tanker to return loading arm to end point Walked straight off the end of](https://reader036.vdocuments.site/reader036/viewer/2022070211/61003f665a526304d64699c1/html5/thumbnails/6.jpg)
What Happened?
� Play video clip now
Tanker fall video.mpg
![Page 7: Fall from Tanker - Ineos · New loading facility Removed loading arm Walked along short walkway attached to tanker to return loading arm to end point Walked straight off the end of](https://reader036.vdocuments.site/reader036/viewer/2022070211/61003f665a526304d64699c1/html5/thumbnails/7.jpg)
Why Did it Happen?
� The barrier system did not fully protect this specific type of tanker
� This type of tanker is unusual
� The loader was not aware he was reaching the edge of the walkway
![Page 8: Fall from Tanker - Ineos · New loading facility Removed loading arm Walked along short walkway attached to tanker to return loading arm to end point Walked straight off the end of](https://reader036.vdocuments.site/reader036/viewer/2022070211/61003f665a526304d64699c1/html5/thumbnails/8.jpg)
Lessons?
� Designing gantry or barrier systems for loading a range of tanker types is not easy!
� Commissioning of such systems needs to check against the full range of tankers to be loaded
� Loading teams need to check every single time that it is safe to load– Does barrier system provide protection for this
type of tanker?
– Is the tanker correctly positioned?
– If not – don’t load the tanker – turn it away!
![Page 9: Fall from Tanker - Ineos · New loading facility Removed loading arm Walked along short walkway attached to tanker to return loading arm to end point Walked straight off the end of](https://reader036.vdocuments.site/reader036/viewer/2022070211/61003f665a526304d64699c1/html5/thumbnails/9.jpg)
What should you check at your
site?
� Take a fresh look at any tanker loading or unloading operations you have
� Are they suitably protected from falls from height?
� Do you know your protection system will work with all types of tanker received at your Site?
� Would your team recognise the risk and be prepared to turn away a tanker if it was not safe to work on?