608 State St. South Kirkland, WA 98033 www.faira.com [email protected] +1.800.571.FAIR FAIRA TRANSPARENCY REPORTS 5810 Fleming St, #84, Everett, WA 98203 July 20 th , 2017 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property. You may view more detailed information for this home and can make an offer at http://www.faira.com/listings/11363 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

Upload: truongminh

Post on 14-Dec-2018

212 views

Category:

Documents


0 download

TRANSCRIPT

608 State St. South Kirkland, WA 98033

www.faira.com

[email protected] +1.800.571.FAIR

FAIRA TRANSPARENCY REPORTS

5810 Fleming St, #84, Everett, WA 98203

July 20th, 2017 Thank you for your interest in this Faira Certified home. We have coordinated the efforts of certified and licensed inspection and title professionals to create the Faira Transparency Reports for this home. The Faira Transparency Reports are a detailed portfolio of information that is prepared on behalf of buyers in preparation for making an informed offer on the property.

You may view more detailed information for this home and can make an offer at

http://www.faira.com/listings/11363 All of the information in the Faira Transparency Reports was gathered and compiled without any bias or influence from the seller(s). In fact, these reports are materially identical had you as the buyer(s) ordered the same professionals to perform the evaluations on the same date. Nevertheless, Faira takes no obligation of the reports being complete or accurate. The buyers are recommended to conduct their own due-diligence to their satisfaction. Please contact us if you have any questions or would like more information. We’re happy you’ve chosen a Faira Certified home and look forward to the opportunity of working with you! The Faira Team

RW West ConsultantsProperty Inspection Report

Cover Page

5810 Fleming St, #84, Everett, WA 98203Inspection prepared for: FAIRA/ Chris Ellis

Real Estate Agent: -

Date of Inspection: 7/19/2017 Time: 9:00 AM Age of Home: 2015 Size: 1032

Weather: Sunny 65 degreesOrder ID: 2329

Front door faces East for orientation purposes only.

Inspector: Dee Robert InmanLicense #1459 UAS Pilots Lic. No. 3976466

Email: [email protected]

RW West Consultants 5810 Fleming St, Everett, WA

Page 1 of 36

Inspection Details INTRODUCTION: We appreciate the opportunity to conduct this inspection for you!   Please carefully read your entireInspection Report.  Call us after you have reviewed your report, so we can go over any questionsyou may have.  Remember, when the inspection is completed and the report is delivered, we are stillavailable to you for any questions you may have, throughout the entire closing process. Properties being inspected do not "Pass" or "Fail.” -  The following report is based on an inspectionof the visible portion of the structure; inspection may be limited by vegetation and possessions. Depending upon the age of the property, some items like GFCI outlets may not be installed; thisreport will focus on safety and function, not current code. This report identifies specific non-code,non-cosmetic concerns that the inspector feels may need further investigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate and repairany critical concerns and defects.  Note that this report is a snapshot in time. We recommend thatyou or your representative carry out a final walk-through inspection immediately before closing tocheck the condition of the property, using this report as a guide. Items denote serious, safety or items that required further investigationItems denote minor or maintenance itemsItems denote locations and shutoff valves1. AttendanceIn Attendance: Seller present

2. Home TypeHome Type: Mobile Home

3. OccupancyOccupancy:• Occupied - Furnished• The utilities were on at the time of inspection.

RW West Consultants 5810 Fleming St, Everett, WA

Page 2 of 36

General Exterior Note 1. Exterior NoteObservations:• North Elevation• South Elevation• East Elevation• West Elevation

||2||East Elevation ||2||South Elevation

||2||North Elevation ||2||West Elevation

RW West Consultants 5810 Fleming St, Everett, WA

Page 3 of 36

Exterior Areas 1. Siding ConditionSiding, paint and caulk appeared in good condition overall. • OSB T111 siding

2. GuttersGutters and downspouts appeared in good condition overall.

3. Driveway and Walkway ConditionAsphalt driveways appeared in good condition overall.

4. SoffitSoffits and eaves appeared in good condition overall.

RW West Consultants 5810 Fleming St, Everett, WA

Page 4 of 36

5. Door/WindowExterior doors appeared in operable condition, at time of inspection. • Threshold and jambsappeared in good condition overall. • Window frames and sills appeared in good condition overall.Observations:• There was no visible flashing above the windows and or doors. Windows and or doors withoutflashing require periodic maintenance of caulking material.

6. GradingGrading appeared in good condition overall.

RW West Consultants 5810 Fleming St, Everett, WA

Page 5 of 36

East yard North yard7. ElectricalExterior outlets operate. • Exterior outlets are GFCI protected. • Exterior lights attached to thehouse operate overall.

8. Cable FeedsMaterials: Primary Service is Underground Service Lateral

RW West Consultants 5810 Fleming St, Everett, WA

Page 6 of 36

9. Exterior Faucet ConditionExterior faucets were in operable condition overall.

10. Pressure110 psiObservations:• Water pressure is in excess of 80 PSI. Water pressure above 80 PSI can result in plumbing leaksand cause plumbing appliances to wear more quickly, recommend adjusting water pressure orinstalling pressure reducing valve.

RW West Consultants 5810 Fleming St, Everett, WA

Page 7 of 36

110 psi

RW West Consultants 5810 Fleming St, Everett, WA

Page 8 of 36

Porches 1. Porch1East

2. PorchPorch surface appeared in good condition, framing was not visible due to ground proximity. •Guardrail appeared secure. • Handrail appeared secure.Observations:• Handrail not graspable. By today's standards, rails should be configured so that a hand maygrasp around a rail for safety.

RW West Consultants 5810 Fleming St, Everett, WA

Page 9 of 36

Roof 1. Roof ConditionComposition shingle roof surface. • Roof surface is appeared in good condition overall. • Walkedon roof surface.Type Average life span 20 years for this type surface with proper maintenance and care.

2. FlashingFlashing appeared in good condition overall.

3. SkylightsSkylights appeared sealed, no visible indications of leakage.

RW West Consultants 5810 Fleming St, Everett, WA

Page 10 of 36

RW West Consultants 5810 Fleming St, Everett, WA

Page 11 of 36

General Interior Note 1. General NotesMaterials: Windows in the home are Double panel insulated glass windows. Any deficiencies arenoted in each room section for accessible windows • Doors in the home are considered operationalunless otherwise noted in each room section

RW West Consultants 5810 Fleming St, Everett, WA

Page 12 of 36

Living Room 1. LocationLocation North

2. Living RoomWalls and ceilings appear in good condition overall. Flooring is wood. Heat register present.Accessible outlets operate.

3. ElectricalMaterials: Bottom halves of outlet on the north wall switch controlled.

RW West Consultants 5810 Fleming St, Everett, WA

Page 13 of 36

Kitchen 1. Kitchen RoomWalls and ceilings appear in good condition overall. Flooring is Tile. Heat register present.Accessible outlets operate. Light fixture operates. Sink and faucets are in operable conditionoverall. Cabinet doors and drawers are in operable condition overall.

2. Counter ConditionFormica counter is in good condition overall.

3. CabinetCabinet doors and drawers are in operable condition overall.

4. DisposalDisposal operates overall.

5. DishwasherDishwasher was in operable condition.

6. Stove/OvenStove/oven were in operable condition overall.

RW West Consultants 5810 Fleming St, Everett, WA

Page 14 of 36

7. RefrigeratorObservations:• Refrigerator does not stay with home

8. SinksSink was in operable condition overall.

9. ElectricalOutlets are GFCI protected at the counters.

10. Vent ConditionVent fan appears to exhaust to the exterior.

RW West Consultants 5810 Fleming St, Everett, WA

Page 15 of 36

Hallway 1. ConditionsCeiling and walls are in good condition overall. Light fixture operates. • Wood flooring is in goodcondition overall

RW West Consultants 5810 Fleming St, Everett, WA

Page 16 of 36

Laundry 1. ConditionCeiling and walls are in good condition overall. Accessible outlets operate. • Light fixture operates.Observations:• Washer and dryer do not stay with the home.

2. Exhaust FansVent fan operates overall.

3. DryerDryer appeared to exhaust to the exterior. • 220 volt electrical service for electric dryer.

4. Floor ConditionTile Flooring is in good condition overall.

5. WasherMaterials: Washer appeared to be in operable condition.

RW West Consultants 5810 Fleming St, Everett, WA

Page 17 of 36

RW West Consultants 5810 Fleming St, Everett, WA

Page 18 of 36

Master Bedroom 1. LocationLocation Northwest

2. BedroomWalls and ceilings appear in good condition overall. Flooring is carpet in good condition. Heatregister present. Accessible outlets operate. • Light fixture operates.

RW West Consultants 5810 Fleming St, Everett, WA

Page 19 of 36

Master Bathroom 1. LocationMaterials: Bedroom

2. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.

3. ElectricalGFI outlets within 6 feet of the water sources.

4. CountersFormica counter tops are in good condition overall.

5. CabinetsCabinet doors are in operable condition overall.

6. SinksSink was in operable condition overall.

7. Exhaust FansVent fan operates overall.

8. FloorsTile Flooring is in good condition overall.

9. TubTub was in good condition overall.

10. ShowerShower is in good condition overall.

11. ToiletToilet was in operable condition overall.

RW West Consultants 5810 Fleming St, Everett, WA

Page 20 of 36

Hall Bathroom1 1. RoomCeiling and walls are in good condition overall. Accessible outlets operate. Light fixture operates.

2. ElectricalGFI outlets within 6 feet of water sources.

3. CountersTile counter tops are in good condition overall. • Formica counter tops are in good condition overall.

4. CabinetsCabinet doors and drawers are in operable condition overall.

5. Exhaust FansVent fan operates overall.

6. FloorsTile Flooring is in good condition overall.

7. SinksSink was in operable condition overall.

8. ToiletToilet was in operable condition overall.

RW West Consultants 5810 Fleming St, Everett, WA

Page 21 of 36

Bedroom 1 1. LocationLocation 1st Right

2. Bedroom RoomWalls and ceilings appear in good condition overall. Flooring is wood. Heat register present.Accessible outlets operate.

RW West Consultants 5810 Fleming St, Everett, WA

Page 22 of 36

Mud Room 1. Mud RoomWalls and ceilings appear in good condition overall. Flooring is tile in good condition overall. • Lightfixture operates.

RW West Consultants 5810 Fleming St, Everett, WA

Page 23 of 36

Carport 1. ConditionWood frame walls appeared in good condition overall. • Outlets are GFI protected at walls.

2. Floor ConditionMaterials: Flooring is asphalt, appeared in good condition overall.

RW West Consultants 5810 Fleming St, Everett, WA

Page 24 of 36

Heat/AC 1. Heating TypeElectric forced air furnace. • Furnace was not tested per the sellers request. Recommendverification of operation before closing.

2. Heater Location The furnace is located in the hall closet upstairs.Furnace is Intertherm Brand.

3. Heating conditionObservations:• Service does not appear to have been performed within the last year, recommend serviced bylicensed HVAC contractor.

4. FiltersLocation: Located inside heater cabinet.Observations:• The furnace filter is dirty. Filters clean the air before it passes through the blower and heatexchanger. This helps to keep these furnace components working efficiently. Dirty Filters lessen lifespan of the Heating/AC equipment. It is recommended to change the filter and then regularinspection & maintenance is advised.

RW West Consultants 5810 Fleming St, Everett, WA

Page 25 of 36

Plumbing/Water Heater1 1. PlumbingWater lines were PEX plastic. • Drain and waste lines were plastic.

2. Water Heater ConditionHeater Type: Electric water heater. • 50 gallonsObservations:• Water heater temperature is in excess of 120 degrees, recommend adjustment to preventaccidental scalding.

3. AgeApproximately 3 years of age, average life span is 10 to 12 years.

4. ConditionObservations:• Seismic straps are not in place/ improperly installed. Normally there should be seismic strapsinstalled at the upper and lower one thirds of the tank.• Expansion tank is not in place. This is a hazardous condition on closed water systems.Recommend conditions are investigated further and corrected as required by licensed plumbingcontractor.

RW West Consultants 5810 Fleming St, Everett, WA

Page 26 of 36

5. TPRV ConditionTemperature Pressure Relief Valve (TPR Valve) present.

RW West Consultants 5810 Fleming St, Everett, WA

Page 27 of 36

Electrical 1 1. LocationMaterials: Located in the Utility Room.

2. Electrical200 AMP service, 4/0 Aluminum service entrance wires.

RW West Consultants 5810 Fleming St, Everett, WA

Page 28 of 36

3. GroundingElectrical service is grounded and bonded.

4. Wiring TypeBreaker system present. Wiring sizes conform to breaker sizes overall. Smaller branch circuit wiringis copper.

RW West Consultants 5810 Fleming St, Everett, WA

Page 29 of 36

Foundation/Crawlspaces 1. LocationExterior NW

2. FoundationUnit rests on concrete blocks and tie downs with wood skirting material.Observations:• Tie downs were noted in 2 locations. Located at the NE and SW corners. Recommend verifyingengineering for tie downs. Typically tie downs are installed every 10 - 12 feet. Recommend furtherinvestigation.

Tie down at SW corner

RW West Consultants 5810 Fleming St, Everett, WA

Page 30 of 36

Tie down at NE corner3. DrainageCrawlspace area was dry, there were no visible indications of standing water presently

4. FramingVisible framing appeared in good condition overall.

5. VentilationVentilation appeared adequate.

6. Insulation ConditionVapor barrier in place. Insulation not visible.

Insulation not visible7. DuctsDucts appeared securely attached and insulated overall.

8. Vapor BarrierVapor Barrier was in place.

RW West Consultants 5810 Fleming St, Everett, WA

Page 31 of 36

9. RodentObservations:• Bait traps present.

10. ElectricalObservations:• Electrical wiring on the floor of the crawlspace. Recommend wiring is secured to the base of theframing as a safety precaution.• Wire ends are outside of a Junction Box, which is a potential shock or electrocution hazard.

RW West Consultants 5810 Fleming St, Everett, WA

Page 32 of 36

RW West Consultants 5810 Fleming St, Everett, WA

Page 33 of 36

Shutoffs 1. Shutoff LocationsObservations:• Water heater water line shutoffs located below the water heater in crawlspace• Main water shutoff is located in crawl space at below water heater location

Main water shutoff in laundry Water heater shut off under house at water heaterlocation

RW West Consultants 5810 Fleming St, Everett, WA

Page 34 of 36

Equipment 1. Appliances/Equipment

||2||Disposal ||2||Dishwasher

||2||Oven ||2||Furnace

RW West Consultants 5810 Fleming St, Everett, WA

Page 35 of 36

GlossaryGlossary

Term DefinitionExpansion Tank An expansion tank or expansion vessel is a small tank used to

protect closed (not open to atmospheric pressure) water heatingsystems and domestic hot water systems from excessivepressure. The tank is partially filled with air, whosecompressibility cushions shock caused by water hammer andabsorbs excess water pressure caused by thermal expansion.

GFCI A special device that is intended for the protection of personnelby de-energizing a circuit, capable of opening the circuit wheneven a small amount of current is flowing through the groundingsystem.

TPR Valve The thermostat in a water heater shuts off the heating sourcewhen the set temperature is reached. If the thermostat fails, thewater heater could have a continuous rise in temperature andpressure (from expansion of the water). The temperature andpressure could continue to rise until the pressure exceeds thepressure capacity of the tank (300 psi). If this should happen, thesuper-heated water would boil and expand with explosive force,and the tank would burst. The super-heated water turns to steamand turns the water heater into an unguided missile. To preventthese catastrophic failures, water heaters are required to beprotected for both excess temperature and pressure. Usually, themeans of protection is a combination temperature- and pressure-relief valve (variously abbreviated as T&P, TPV, TPR, etc.). Mostof these devices are set to operate at a water temperature above200° F and/or a pressure above 150 psi. Do not attempt to testthe TPR valve yourself! Most water heating systems should beserviced once a year as a part of an annual preventivemaintenance inspection by a professional heating and coolingcontractor. From Plumbing: Water Heater TPR Valves

RW West Consultants 5810 Fleming St, Everett, WA

Page 36 of 36

Report SummaryReport Summary

The summary below consists of potentially significant findings. These findings can be a safetyhazard, a deficiency requiring a major expense to correct or items I would like to draw extra attentionto. The summary is not a complete listing of all the findings in the report, and reflects the opinion ofthe inspector. Please review all pages of the report as the summary alone does not explain all of theissues. All repairs should be done by a licensed & bonded tradesman or qualified professional. Irecommend obtaining a copy of all receipts, warranties and permits for the work done.Exterior AreasPage 6 Item: 10 Pressure • Water pressure is in excess of 80 PSI. Water pressure

above 80 PSI can result in plumbing leaks and causeplumbing appliances to wear more quickly, recommendadjusting water pressure or installing pressure reducing valve.

PorchesPage 8 Item: 2 Porch • Handrail not graspable. By today's standards, rails should

be configured so that a hand may grasp around a rail forsafety.

Plumbing/Water Heater1Page 25 Item: 2 Water Heater

Condition• Water heater temperature is in excess of 120 degrees,recommend adjustment to prevent accidental scalding.

Page 26 Item: 4 Condition • Seismic straps are not in place/ improperly installed.Normally there should be seismic straps installed at the upperand lower one thirds of the tank.• Expansion tank is not in place. This is a hazardous conditionon closed water systems. Recommend conditions areinvestigated further and corrected as required by licensedplumbing contractor.

Foundation/CrawlspacesPage 29 Item: 2 Foundation • Tie downs were noted in 2 locations. Located at the NE and

SW corners. Recommend verifying engineering for tie downs.Typically tie downs are installed every 10 - 12 feet.Recommend further investigation.

Page 31 Item: 9 Rodent • Bait traps present.Page 31 Item: 10 Electrical • Electrical wiring on the floor of the crawlspace. Recommend

wiring is secured to the base of the framing as a safetyprecaution.• Wire ends are outside of a Junction Box, which is a potentialshock or electrocution hazard.