![Page 1: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/1.jpg)
Facility Master Files
Adrian GeeBaylor College of Medicine
![Page 2: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/2.jpg)
What are Master Files?
Documents submitted to and held on file by the FDA
Describe manufacturing processes, devices or facilities
Are kept confidential from other parties
May be cross-referenced by author and other parties (with written permission)
![Page 3: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/3.jpg)
Types of Master Files
Type I: Manufacturing Site, Facilities, Operating Procedures, and Personnel
Type II: Drug Substance, Drug Substance Intermediate, and Material Used in Their Preparation, or Drug Product
Type III: Packaging Material
Type IV: Excipient, Colorant, Flavor, Essence, or Material Used in Their Preparation
Type V: FDA Accepted Reference Information
![Page 4: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/4.jpg)
Change of Categories
Facility information is now submitted as a Type V Master File – and specific reference is made to Facilities for Production of Gene or Cell Based Therapies
![Page 5: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/5.jpg)
Guidance DocumentAugust 2001
http://www.fda.gov/cber/gdlns/dmfv.pdfNo letter of Intent Required for this Type of File
![Page 6: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/6.jpg)
Type V Master File
Include information to assess the safety of the products used in clinical trials of gene or cell-based therapies
Floor diagrams showing manufacturing areas
List of products manufactured
Equipment areas dedicated or shared
Overview of production steps for all products manufactured
![Page 7: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/7.jpg)
Type V Master File
Description of containment features and contamination precautions
Specialized equipment
Air quality classification
Description of air handling units
Pressure differentials
![Page 8: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/8.jpg)
Type V Master File
Screening & acceptance procedures for all cell lines brought into the Facility
![Page 9: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/9.jpg)
Advantages
Since facilities are used to generate vectors or to transduce or manipulate cells used in a number of trials under IND, a Type V DMF eliminates the need to submit the same information numerous times & facilitates IND review
Attractive to investigators wishing to use Facility
![Page 10: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/10.jpg)
Disadvantages
Lot of up-front work to assemble
Must be kept updated (yearly)
If unacceptable to FDA then all related INDs can be put on hold
![Page 11: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/11.jpg)
Current Cell Processing Facility Master Files
NIH Cell Processing FacilityPACT Centers
University of PittsburghUniversity of MinnesotaBaylor College of Medicine
??
![Page 12: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/12.jpg)
Table of ContentsBaylor Master File
1. General Introduction 2. Other Manufacturing Activities within the CPF 3. Name and Address of Site, Contact Information 4. Types of Products Manufactured 5. Short Description of the Site
a. Figure 1: Floor plan of Cell Processing Facility b. Figure 2: Traffic Patterns within the CPF c. Figure 3: Air Pressure Relationships in CPF
6. Employees Quality Assurance Quality Control Production Materials HandlingTechnical & Support Service Total Staff
![Page 13: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/13.jpg)
7. Outside Scientific, Analytical and Technical Assistance8. Quality Management System
Quality PolicyQuality Assurance FunctionElements of the Quality Assurance SystemProcess ValidationDocumentation of TrainingTracking of Variances from SOPs and other ProceduresAccessioning of Cells and TissuesSupply Release & Supply Release Specifications Tracking of Supplies & Equipment during Manufacturing Monitoring of the Facility, Equipment, Alarm SystemPerformance of QC Tests
Table of ContentsBaylor Master File
![Page 14: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/14.jpg)
8. Quality Management SystemCoordination of Testing by External LaboratoriesMaintaining the QA/QC DatabaseLabel ControlProduct ReleaseAudits – Internal & ExternalQuality MeetingsPatient Monitoring/Complaints File
9. PersonnelResponsibilities of Key StaffTraining of Manufacturing StaffHealth & Hygiene Requirements
Table of ContentsBaylor Master File
![Page 15: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/15.jpg)
10.FacilitiesConstruction and FinishesHVAC SystemEmergency Power SystemStructural Repairs &Facility MaintenanceCleaningEquipment handling
11. DocumentationStandard Operating ProceduresManufacturing RecordsBatch Record & WorksheetsTesting & QA/QC DocumentationError Detection
13.Production – generic major steps
Table of ContentsBaylor Master File
![Page 16: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/16.jpg)
13. Materials ManagementStarting MaterialsStorage AreaFinal ProductsRejected MaterialsProcess Validation
14. Quality Control15. Distribution, Complaints & Product Recall
Storage & DistributionComplaints FileQuality Indicators and Audits
Appendix A: CPF Organizational Chart and CVs of Key PersonnelAppendix B: Facility Air Balance ReportAppendix C:
C1: Listing of Relevant SOPs, Copies of Cited SOPsC2: Full Table of Contents from SOP Manual
Appendix D: Initial Validation of Barcode ScannersAppendix E: Validation of Cleaning Procedures
Table of ContentsBaylor Master File
![Page 17: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/17.jpg)
Submission of Master File
Center for Biologics Evaluation and ResearchDocument Control Center, HFM-99, Suite 200N1401 Rockville PikeAttn: OCTGT/RMS
No electronic submissionsMust submit in special binders (1 original & 2 archive)
http://www.fda.gov/cder/ddms/binders.htm
![Page 18: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/18.jpg)
Review
Review took about one yearMinor comments related to
Vendor auditsAir handlingQualification of FacilityMicrobial species detectedCleaning Validation
![Page 19: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/19.jpg)
Cross-Reference
Letters
![Page 20: Facility Master Files - PACT GROUPpactgroup.net/system/files/webcast4_gee.pdf8. Quality Management System Coordination of Testing by External Laboratories Maintaining the QA/QC Database](https://reader031.vdocuments.site/reader031/viewer/2022011813/5e43b62888c0e928ce477446/html5/thumbnails/20.jpg)
Take Home Messages
Master Files eliminate the need for repetitive submission of facility information to the FDA
Preparation and updating are tedious and time-consuming
Rejection by FDA places related INDs on hold