F-Area Tank Farm Groundwater Sampling and Analysis Plan (U)
SRNS-RP-2012-00287 Revision 1 November 2012
DISCLAIMER
This document was prepared in conjunction with work accomplished under Contract No. DE-AC09-08SR22470 with the U.S. Department of Energy. This work was prepared under an agreement with and funded by the U.S. Government. Neither the U.S. Government or its employees, nor any of its contractors, subcontractors or their employees, makes any express or implied: 1. warranty or assumes any legal liability for the accuracy, completeness, or for the use or results of such use of any information, product, or process disclosed; or 2. representation that such use or results of such use would not infringe privately owned rights; or 3. endorsement or recommendation of any specifically identified commercial product, process, or service. Any views and opinions of authors expressed in this work do not necessarily state or reflect those of the United States Government, or its contractors, or subcontractors
Printed in the United States of America Prepared for
U. S. Department of Energy and
Savannah River Site Nuclear Solutions, LLC Aiken, South Carolina
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page i of v
TABLE OF CONTENTS Section Page
LIST OF FIGURES ....................................................................................................................... ii
LIST OF TABLES ........................................................................................................................ iii
LIST OF ACRONYMS AND ABBREVIATIONS .................................................................... iv
1.0 INTRODUCTION ............................................................................................................ 1 1.1 Sampling Unit Name and Purpose for Sampling ............................................................... 1 1.2 Sampling Unit Location ....................................................................................................... 2 1.3 Statement of Broad Objectives for the Sampling .............................................................. 2
2.0 SAMPLING UNIT BACKGROUND ............................................................................. 2 2.1 Sampling Area Physical and Geographical Description ................................................... 2
2.1.1 Physical Setting .............................................................................................................. 2 2.1.2 Climate ........................................................................................................................... 3 2.1.3 Hydrostratigraphy .......................................................................................................... 3
2.2 Operational History .............................................................................................................. 4 2.3 Previous Investigations/Regulatory Actions ....................................................................... 6
2.3.1 Tank 8 Release and Investigation .................................................................................. 7 2.3.2 F-Area Tank Farm Groundwater Monitoring ................................................................ 7 2.3.3 FFA Operable Unit Investigations ................................................................................. 8
2.4 Summary of Existing Data ................................................................................................... 9
3.0 PROJECT DATA QUALITY OBJECTIVES (DQOS) .............................................. 11 3.1 Groundwater at the F-Area Tank Farm ........................................................................... 11
3.1.1 State the Problem ......................................................................................................... 11 3.1.2 Identify Goals of the Study .......................................................................................... 12 3.1.3 Identify Information Inputs .......................................................................................... 12 3.1.4 Define the Boundaries of the Study ............................................................................. 13 3.1.5 Develop the Analytical Approach ................................................................................ 13 3.1.6 Specify Performance or Acceptance Criteria ............................................................... 15 3.1.7 Develop the Plan for Obtaining the Data (Project Quality Objectives) ....................... 16
4.0 SAMPLING DESIGN AND RATIONALE ................................................................. 17 4.1 Rationale for FTF Groundwater Sample and Analysis Plan .......................................... 18
4.1.1 Groundwater Sampling of Newly Installed and Existing Monitoring Wells ............... 18 4.1.2 Data Evaluation ............................................................................................................ 19 4.1.3 Reporting ...................................................................................................................... 19
5.0 ANALYTICAL PLAN ................................................................................................... 19 5.1 Data Quality Levels ............................................................................................................ 20 5.2 Field Analytical Sampling Quality Assurance/Quality Control ..................................... 20 5.3 Sample Matrix Table .......................................................................................................... 22 5.4 Sample Location Map ......................................................................................................... 22
6.0 FIELD IMPLEMENTATION ....................................................................................... 22 6.1 List of Sampling/Collection Equipment ............................................................................ 23 6.2 Investigation Derived Waste .............................................................................................. 23
7.0 REFERENCES ............................................................................................................... 24
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page ii of v
LIST OF FIGURES
FIGURE 1: LOCATION OF F AREA IN THE GENERAL SEPARATIONS AREA AT THE
SAVANNAH RIVER SITE ............................................................................... 29
FIGURE 2: LOCATION OF THE F-AREA TANK FARM AT F AREA, SRS .......................... 30
FIGURE 3: HYDROSTRATIGRAPHIC UNITS AT F AREA (MODIFIED FROM AADLAND ET
AL, 1995) ...................................................................................................... 31
FIGURE 4: POTENTIOMETRIC SURFACE AND GROUNDWATER FLOW DIRECTIONS AT
THE F-AREA TANK FARM ........................................................................... 32
FIGURE 5: SURFACE AND GROUNDWATER FLOW AT THE GENERAL SEPARATIONS AREA
(MODIFIED FROM SRR, 2011) ..................................................................... 33
FIGURE 6: LOCATION OF FFA OUS AND KEY FACILITIES AT THE F-AREA TANK FARM
...................................................................................................................... 34
FIGURE 7: HISTORICAL NONVOLATILE BETA AND TECHNETIUM-99 ACTIVITIES IN
MONITORING WELL FTF 28 ....................................................................... 35
FIGURE 8: LOCATION OF UAZ AND LAZ WELLS AT AND NEAR THE F-AREA TANK
FARM............................................................................................................ 36
FIGURE 9: LOCATION OF WELLS FOR THE F-AREA TANK FARM GROUNDWATER
MONITORING NETWORK ............................................................................. 37
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page iii of v
LIST OF TABLES
TABLE 1: DATA QUALITY OBJECTIVES WORKSHEET FOR GROUNDWATER AT THE F-AREA TANK FARM ....................................................................................... 39
TABLE 2: MONITORING PARAMETERS FOR THE F-AREA TANK FARM GROUNDWATER
MONITORING PLAN ..................................................................................... 40
TABLE 3: SAMPLING MATRIX TABLE ............................................................................. 41
TABLE 4: LABORATORY CONTRACT REQUIRED DETECTION LIMITS COMPARED TO
REGIONAL SCREENING LEVELS FOR SURFACE OR GROUNDWATER MEDIA
...................................................................................................................... 43
TABLE 5: MINIMUM DETECTED ACTIVITY COMPARED TO WATER RADIOLOGICAL
MCL/PRGS ................................................................................................. 44
TABLE 6: MINIMUM FIELD QUALITY CONTROL/QUALITY ASSURANCE SAMPLING
REQUIREMENTS ........................................................................................... 45
TABLE 7: LABORATORY ANALYTICAL SPECIFICATIONS TABLE FOR TAL/TCL
ANALYTES FOR GROUNDWATER MEDIA .................................................... 46
TABLE 8: LABORATORY ANALYTICAL SPECIFICATIONS TABLE FOR RADIOLOGICAL
ANALYTES IN SOIL, SEDIMENT, SURFACE, AND GROUNDWATER MEDIA .. 47
TABLE 9: PRESERVATIVES, HOLDING TIMES, AND SAMPLE CONTAINERS FOR
GROUNDWATER COLLECTED AT THE FTF................................................. 48
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page iv of v
LIST OF ACRONYMS AND ABBREVIATIONS
Acronym Meaning
CERCLA Comprehensive Environmental Response, Compensation and Liability Act Ci curies cm centimeter CRDL Contract Required Detection Limit CSM Conceptual Site Model DQD Decision Quality Data DQI Data Quality Indicator DQO Data Quality Objective ERDMS Environmental Restoration Data Management System FFA FIPSL
Federal Facility Agreement F-Area Inactive Process Sewer Line
ft3 cubic feet ft feet FTF F-Area Tank Farm GAU Gordon Aquifer Unit GCP General Closure Plan GWMP Groundwater Monitoring Plan GSA HTF
General Separations Area H-Area Tank Farm
IDW Investigation Derived Waste in inches km2 square kilometers L liters LAZ Lower Aquifer Zone LLC Limited Liability Company m meter MCL Maximum Contaminant Level MDA Minimum Detected Activity mi2 square miles mL milliliters OU Operable Unit PA Performance Assessment pCi pico curies PQO Project Quality Objective PRG Preliminary Remediation Goal PVC polyvinyl chloride QA Quality Assurance QAPP Quality Assurance Project Plan QC Quality Control RCRA Resource Conservation and Recovery Act RFI RCRA Facility Investigation
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page v of v
LIST OF ACRONYMS AND ABBREVIATIONS
Acronym Meaning
RI Remedial Investigation ROD Record of Decision RPD Relative Percent Difference RSL USEPA Regional Screening Level SAP Sampling and Analysis Plan SCDHEC South Carolina Department of Health and Environmental Control SRNS Savannah River Nuclear Solutions, LLC SRR SRS
Savannah River Remediation, LLC Savannah River Site
ssEQL Sample Specific Estimated Quantitation Limit mg milligrams TAL Target Analyte List TCL Target Compound List UAZ Upper Aquifer Zone UCL Upper Control Limit USDOE United States Department of Energy USEPA United States Environmental Protection Agency UTRA Upper Three Runs Aquifer VV Verified and Validated WSRC Westinghouse Savannah River Company, LLC prior to December 8, 2005;
Washington Savannah River Company, LLC after December 8, 2005
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 1 of 48
1.0 INTRODUCTION
This Sampling and Analysis Plan (SAP) for the F-Area Tank Farm (FTF) was prepared
using the approved template for Sampling and Analysis Plans. The SAP template was
prepared in accordance with the United States Environmental Protection Agency
(USEPA) Uniform Federal Policy for Quality Assurance Project Plans (USEPA et al
2005) and the Area Completion Projects Programmatic Quality Assurance Project Plan
for Environmental Data Collection and Management (SRNS 2012a). Project- or task-
specific information of the FTF is documented in the SAP and refers to the program level
Quality Assurance Program Plan (QAPP) (SRNS 2012a) for the program level quality
objectives, standard operating procedures, and quality assurance/quality control
procedures.
1.1 Sampling Unit Name and Purpose for Sampling
As required by the Industrial Wastewater General Closure Plan for F-Area Waste Tank
Systems (SRR 2011) (herein referred to as the General Closure Plan [GCP]) monitoring
of the groundwater beneath the FTF will continue as requested by South Carolina
Department of Health and Environmental Control (SCDHEC) in support of Construction
Permit # 17,424-IW. Groundwater monitoring will be conducted in accordance with the
an approved FTF Groundwater Monitoring Plan (GWMP) during the interim period from
the time the individual waste tanks and ancillary equipment are removed from service
through post-closure groundwater monitoring defined in a final Record of Decision
(ROD) for the FTF Operable Unit (OU). There are currently two monitoring programs in
place [i.e., FTF/H-Area Tank Farm (HTF) Groundwater Monitoring and General
Separations Area (GSA) Western Groundwater OU] that utilize data from wells at and
around the FTF to document current groundwater conditions.
The F-Area Tank Farm Groundwater Monitoring Plan, Revision 1, was submitted in
February 2012 and approved by both regulatory agencies (SRNS 2012b). The FTF
GWMP includes a description of the groundwater monitoring network, sampling
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 2 of 48
frequency, constituents and associated detection limits, reporting frequency, and triggers
for evaluation of corrective action. The Core Team agreed that the details of the
sampling plan, including the sampling design and data quality objectives process, could
be presented in a separate SAP in support of the approved GWMP.
1.2 Sampling Unit Location
F Area occupies 364 acres in the north-central portion of the Savannah River Site (SRS)
within an area commonly referred to as the GSA (Figure 1). The GSA is located atop a
ridge running southwest to northeast that forms the drainage divide between Upper Three
Runs Creek to the north, Fourmile Branch to the south, and McQueen Branch to the east
and encompasses approximately 39 km2 (15 mi2). The FTF is located in the southern part
of F Area and occupies 22 acres (Figure 2).
The FTF is an active facility and is heavily developed. The FTF site was chosen because
of its favorable terrain and its proximity to the F-Canyon Separations Facility (the major
waste generation source), which was located near the center of the site, away from the
SRS boundaries.
1.3 Statement of Broad Objectives for the Sampling
The primary objective of the SAP is to develop the sampling design and data quality
objectives in support of the detection monitoring program as outlined in the approved
FTF GWMP.
2.0 SAMPLING UNIT BACKGROUND
2.1 Sampling Area Physical and Geographical Description
2.1.1 Physical Setting
Surface elevations at the FTF range from approximately 85 to 91.5 m (280 to 300 ft)
above mean sea level. Ground cover at the FTF is predominantly asphalt paving with
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 3 of 48
little surface exposed to infiltration. Surface runoff is predominantly to the south, west,
and north to tributaries of Fourmile Branch and Upper Three Runs Creek.
2.1.2 Climate
Rainfall at the site tends to be evenly distributed throughout the year. The average annual
precipitation at SRS is 121.9 cm (48 in). The evaporation rate is approximately 76.2 cm
(30 in) per year. The most severe weather is limited to frequent thunderstorms and
infrequent tornadoes and hurricanes. Additional details concerning the climatology and
meteorology of SRS can be found in the Performance Assessment (PA) for the FTF (SRR
2010a).
2.1.3 Hydrostratigraphy
The SRS lies in the Atlantic Coastal Plain, a southeast-dipping wedge of unconsolidated
and semi-consolidated sediment, which extends from its contact with the Piedmont
Province at the Fall Line to the continental shelf edge. Sediments range in geologic age
from Late Cretaceous to Recent and include sands, clays, limestones, and gravels. This
sedimentary sequence ranges in thickness from essentially zero at the Fall Line to more
than 1,219 m (4,000 ft) at the Atlantic Coast. At SRS, coastal plain sediments thicken
from approximately 213 m (700 ft) at the northwestern boundary to approximately 430 m
(1,410 ft) at the southeastern boundary of the site and form a series of aquifers and
confining and semi-confining units. Aquifer systems include the Floridan, Dublin, and
Midville systems.
Groundwater within the Floridan Aquifer system flows toward streams and swamps and
into the Savannah River at rates ranging from inches to several hundred feet per year.
The depth to which nearby streams cut into sediments, the lithology of the sediments, and
the orientation of the sediment formations control the horizontal and vertical movement
of the groundwater. The valleys of smaller perennial streams, such as Fourmile Branch,
McQueen Branch, and Crouch Branch in the GSA, allow discharge from the shallow
saturated geologic formations. With the release of water to the streams, the hydraulic
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 4 of 48
head of the aquifer unit releasing the water can become less than that of the underlying
unit. If this occurs, groundwater has the potential to migrate upward from the lower unit
to the overlying unit.
The hydrogeology at the FTF resides on coastal plain sediments consisting of alternating
sequences of sands, silts, and clays. The Upper Three Runs Aquifer (UTRA) is the
shallowest aquifer beneath the GSA. A semi-continuous confining unit (i.e., commonly
referred to as the “tan clay” confining zone) divides the UTRA into the Upper Aquifer
Zone (UAZ) and Lower Aquifer Zone (LAZ). A more continuous aquitard, the Gordon
Confining Unit (commonly referred to as the “green clay”) underlies the LAZ and
confines the underlying Gordon Aquifer Unit (GAU). Figure 3 depicts the regional
lithologic units and their corresponding hydrostratigraphic units (i.e., aquifers and
confining units) at SRS (Aadland et al 1995).
Current water level data indicate depth to shallow groundwater varies from 15.2 to 22 m
(50 to 72 ft) below land surface. Because the FTF resides on a topographic high within
the GSA, shallow groundwater flow mirrors the topography and is radially outward
towards nearby streams and swamps which eventually flow to the Savannah River
(Figure 4). The rate of flow in the shallow groundwater varies from inches to several feet
per year.
The depth of which nearby streams cut in to sediments, the lithology of the sediments,
and the orientation of the sediment formations control the horizontal and vertical
movement of the groundwater. Figure 5 depicts a conceptual diagram of surface and
groundwater flow at the GSA.
2.2 Operational History
The FTF was constructed to receive waste generated by various SRS production,
processing, and laboratory facilities. The use of the FTF isolated these wastes from the
environment, SRS workers, and the public. Facilities are in place to pretreat the
accumulated sludge and salt solutions (supernate) to enable the management of these
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 5 of 48
wastes within other SRS facilities (i.e., Defense Waste Processing Facility and Saltstone
Production Facility). These treatment facilities convert the sludge and supernate to more
stable forms suitable for permanent disposal in a federal repository or the Saltstone
Disposal Facility, as appropriate.
The FTF consists of approximately 45,000 ft (8.5 miles) of transfer lines, 22 liquid waste
storage tanks, two evaporator systems, transfer pipelines, six diversion boxes, one catch
tank, a concentrate transfer system tank, and three pump pits. There are three major waste
tank types in FTF that range in size from 750,000 gallons (Type I tanks) to 1.3 million
gallons (Type III and Type IV tanks) and have varying degrees of secondary containment
and intra-tank interference, such as cooling coils and columns. Each of the tank types
were constructed at different times during which design features were greatly improved
upon.
The waste tanks are designated new style or old style based on type of containment, type
of leak detection and/or leakage. The old style tanks do not meet current standards for
secondary containment and/or leak detection or have leaked. Even though the FTF is still
in the operational period, the USDOE is in the process of removing wastes from tanks to
achieve operational closures under the Savannah River Site’s Federal Facility Agreement
(FFA). As required by SCDHEC Regulation 61-67, Standards for Wastewater Facility
Construction and SCDHEC Regulation 61-82, Proper Closeout of Wastewater Treatment
Facilities and Construction Permit #17,424-IW a closure plan has been prepared to
support the removal from service of the FTF underground radioactive waste tanks and
ancillary equipment.
USDOE’s anticipated schedule for removal of the waste tank systems from service was
developed in accordance with federal and state agreements. The FFA provides dates for
bulk waste removal efforts and completion of operational closures of Type I, Type II and
Type IV tanks (i.e., waste tanks that do not meet the standards set forth in Appendix B of
the FFA). Type III and Type IIIA tanks will remain in service until there is no longer a
need for them to support waste treatment, as described in the Savannah River Site
approved Site Treatment Plan, 2010 Update (SRNS 2011a).
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 6 of 48
During the waste tank operational closure period, at-tank leak detection is conducted by
automatic surveillance of sump monitoring systems. Daily inspections are conducted with
monitoring of secondary containment piping, routine direct visual camera surveys in the
annular spaces and non-routine direct visual camera surveys in primary tanks through
opened access risers and/or inspection ports in the roof. The leak detection and tank
inspection program conducted in accordance with the annual HLW Tank Farm Inspection
Plan will continue until agreement is reached to cease waste removal operations. Results
of the inspection program are reported annually on or before July 01 of each year as
required by Section IX.A.2 of the FFA and C Permit 17,424-IW.
USDOE is in the process of removing the remaining FTF waste tanks and ancillary
structures from service in accordance with the FTF General Closure Plan (SRR 2011) and
tank system-specific closure modules. Additional details concerning the regulatory
framework related to waste tank closure and removal from service can be found in the
FTF GCP (SRR 2011).
2.3 Previous Investigations/Regulatory Actions
The tanks in the FTF have only showed evidence of minor leaks which were typically
contained within the tank annulus (SRR 2010b; WSRC 1991; WSRC 1994). Other minor
releases and spills have been noted due to equipment failure, corrosion or operator error
(WSRC 1991). These sites have been placed in the FFA’s Appendix C (Resource
Conservation and Recovery Act [RCRA]/Comprehensive Environmental Response,
Compensation and Liability Act [CERCLA] Units List) as part of the FTF OU for
evaluation and possible remediation (WSRC 1996).
To support ongoing operation and closure of the FTF waste tanks per the GCP,
groundwater is currently monitored at the FTF according to the FTF Groundwater
Monitoring Plan (SRNS 2012b).
The following sections provide a summary of operations investigative work completed or
ongoing at the FTF. Additionally, because the groundwater at the FTF is included within
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 7 of 48
a larger FFA OU (i.e., GSA Western Groundwater OU), a summary of other OU
groundwater investigations performed in the area is also provided to illustrate previous
conditions of the groundwater system.
2.3.1 Tank 8 Release and Investigation
In 1961, approximately 1,500 gallons of waste leaked into subsurface soil from Tank 8 as
a result of an overfill (Garvin et al 1975). Investigation of the area in 1975 and 1976
through soil borings and dry well monitoring with radiation detectors determined an area
approximately 1,000 – 1,500 ft3 of soil was contaminated to a depth of 3.7 to 7.9 m (12 to
26 ft) below grade (Odum 1976). It was estimated that approximately 5,000 Ci of
cesium-137 and lesser amounts of strontium-90 and plutonium-238/239 were also present
(Odum 1976).
Analysis of the data determined that based on the location of the zone of contamination
and ion exchange capabilities of the soil, it was estimated that it would be many years
before the contamination reached shallow groundwater (Garvin et al 1975). Subsequent
soil investigation conducted in 1986 concluded that the zone of contamination had not
moved laterally (Grant et al 1986). There have been no additional studies since that time.
However, groundwater monitoring has continued as described below.
2.3.2 F-Area Tank Farm Groundwater Monitoring
The FTF groundwater monitoring program is currently being conducted according to the
FTF Groundwater Monitoring Plan (SRNS 2012b). The FTF Groundwater Monitoring
program is designed to monitor groundwater quality associated with the tank systems and
to detect any future impacts to groundwater that may occur. The results are reported
annually which includes a discussion of any trends and/or changes in the groundwater
quality conditions.
Various historical spills and releases have been recorded at the FTF. To determine
potential impact, groundwater monitoring and data analysis were needed at the FTF.
Therefore, between 1972 and 1984, 27 monitoring wells with prefix FTF were installed
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 8 of 48
in the FTF in locations that surrounded tank groupings. These wells were all installed
near the top of the water table aquifer (approximately 21.3 to 30.5 m [70 to 100 ft] below
ground surface).
By the early 2000’s, 18 of the FTF wells inside the facility had become unusable due to
the accumulation of sand and silt resulting in reduced or no flow. Because most of these
wells were on the north side of the facility, new wells (FTF 28 and FTF 29) were added
in 2002 and installed in the deeper LAZ of the UTRA along likely flow paths leading
from the FTF to Upper Three Runs Creek. These wells were located outside the FTF
facility away from areas of contaminated soil and historical spill sites. The FTF
monitoring program presently uses eleven (11) of the FTF prefixed wells.
Samples are collected and analyzed for gross alpha, nonvolatile beta, tritium, and nitrate-
nitrite. Sodium and total chromium are also analyzed to monitor the cooling systems.
The current results are presented in the latest F/HTF groundwater report (SRNS 2012c).
2.3.3 FFA Operable Unit Investigations
USDOE currently has an active groundwater monitoring program for monitoring
groundwater impacts from historical releases and spills within F Area and the FTF
(including the waste tanks). These spill sites were previously listed on the FFA
Appendix G (Site Evaluation Areas) by USDOE at the time of FFA approval and have
subsequently been placed on Appendix C (RCRA/ CERCLA Units List) as part of the
FTF OU for evaluation and possible remediation.
Sources of contamination present in groundwater at the FTF are derived from historical
releases from these spill sites. The FFA spill sites as listed for the FTF OU are depicted
on Figure 6.
In an effort to adequately monitor groundwater at F Area due to multiple sources and the
industrial setting the F-Area Tank Farm Groundwater OU and the F-Area Canyon
Groundwater OU were created; these were later combined and the name was changed to
the GSA Western Groundwater OU (WSRC 2004). This combined OU encompasses the
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 9 of 48
FTF, F-Area Canyon, F-Area Burning/Rubble Pits, F-Area Inactive Process Sewer Lines
(FIPSL) and several basins. Monitoring of groundwater, seeplines, and surface water is
being performed at a predetermined sampling frequency and number of wells as well as
for specific analytes.
As cited in the RCRA Facility Investigation/Remedial Investigation (RFI/RI) Phase 1
Work Plan for the General Separations Area (GSA) Western Groundwater Operable Unit
(U), numerous wells have been installed and monitored. Depth discrete samples primarily
from the UAZ and LAZ of the UTRA have been collected since 1997. Primary
contaminants detected downgradient of the FTF include tritium, nitrate, gross alpha, and
nonvolatile beta. Most of the detected contaminants are found in the UTRA (WSRC
2004).
In 2010, nonvolatile beta was the most widespread contaminant detected at levels
exceeding 50 pCi/L (SRNS 2011b). There is an existing nonvolatile beta groundwater
plume downgradient of the FTF in the LAZ that may be attributed to the Tank 8 release
of 1961, but is most likely due to the nearby FIPSL, which is a common source of
nonvolatile beta activities in groundwater (WSRC 2001). However, currently there are
no nonvolatile beta activities greater than 50 pCi/L at the FTF. Figure 7 depicts
nonvolatile beta and technetium-99 activities in monitoring well FTF 28. Historically,
the highest concentrations have been detected in the area near well FTF 28 and
downgradient of this well and the FIPSL.
2.4 Summary of Existing Data
Groundwater monitoring wells installed within and around the FTF are included in the
existing groundwater data and discussed in this summary. Wells interior to the FTF near
and around the waste tanks include those wells with the FTF prefix (Figure 8). These
wells have been monitored for a number of years and a subset of these wells is currently
monitored in support of the FTF annual groundwater report. Currently, there are a total
of 29 FTF wells and all but two of these wells monitor the UAZ. The other two wells
monitor downgradient groundwater quality in the LAZ. Approximately half of the FTF
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 10 of 48
well series were installed in 1972 and 1973 with most of the wells constructed of
polyvinyl chloride (PVC). Of the remaining half of wells, all but two were installed in
1984 and the remaining two were installed in 2002. These wells all are constructed of
PVC.
The older FTF wells (i.e., 1972/1973) in the tank farm interior were constructed to
standards that are currently recognized as insufficient for environmental monitoring (due
to for example the filter packs, seals, grouting, casing materials, pump components, etc.).
Because of this situation, the 2012 Core Team removed these wells from the FTF
monitoring network.
As described in Section 2.3, spills and releases have occurred at the FTF. Investigation
of these spills/releases have noted impact to subsurface soil and groundwater. However,
impact to groundwater has been limited in extent. Historical groundwater monitoring of
the UAZ within the FTF has been performed at the FTF well series. As described earlier,
the older wells are not constructed to current well standards and as such monitoring
conducted at these wells has been limited to various metals and radionuclides.
Based on prior Core Team agreement from previous scoping meetings associated with the
GSA Western Groundwater OU and current FTF GWMP, the principal groundwater
contaminants identified at the FTF are nitrate/nitrite, cadmium, chromium, manganese,
sodium, tritium, and technetium-99. The selection of these groundwater contaminants is
based on process knowledge of FTF operations, spills/releases, and groundwater data. In
addition, radionuclide indicators, gross alpha and nonvolatile beta, are also of interest
since these constituents provide necessary information in regards to the potential
presence of other radionuclides (natural and/or man-made).
A review of historical groundwater data associated with the constituents of concern from
those wells at the FTF (i.e., FTF well series) are summarized in the FTF Groundwater
Monitoring Plan (SRNS-RP-2011-00995), Section 5.0, FTF Groundwater Monitoring to
Date. .
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 11 of 48
3.0 PROJECT DATA QUALITY OBJECTIVES (DQOs)
The Data Quality Objective (DQO) process is a series of logical steps that guides
managers or staff to a plan for the resource-effective acquisition of environmental data.
It is both flexible and iterative, and applies to both decision-making (i.e.,
compliance/non-compliance with a standard) and estimation (i.e., ascertaining the mean
concentration level of a contaminant). The DQO process is used to establish performance
and acceptance criteria, which serve as the basis for designing a plan for collecting data
of sufficient quality and quantity to support the goals of the study. Use of the DQO
process leads to efficient and effective expenditure of resources; consensus on the type,
and quantity of data needed to meet the project goal; and the full documentation of
actions taken during the development of the project. The DQO process is a series of
seven planning steps based on the scientific method (Sections 3.1.1 to 3.1.7 below) and is
detailed in USEPA Guidance (USEPA 2006).
3.1 Groundwater at the F-Area Tank Farm
The intent of this document is to provide supporting information in regards to
groundwater monitoring in accordance with the FTF GWMP during the interim period
from the time the waste tanks and ancillary equipment are removed from service and final
closure of the FTF OU. It is not the intent of this document to address all known sources
to the groundwater or to address potential soil contamination areas from previous known
spills or releases. This will be addressed as part of the FTF OU and GSA Western
Groundwater OU investigations.
3.1.1 State the Problem
Pursuant to FTF GCP Section 8.0 - Maintenance and Monitoring, USDOE and
SCDHEC, in consultation with USEPA must agree to a monitoring plan. Specifically the
GCP states:
Groundwater monitoring will be continued as requested by SCDHEC in support
of Construction Permit #17,424-IW during the interim period from the time the
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 12 of 48
individual waste tanks and ancillary structures are removed from service up to
the final closure of the FTF OU in accordance with an FTF groundwater
monitoring plan.
This plan includes such elements as a groundwater monitoring network, sampling
frequency, constituents and associated detection limits, reporting frequency, data
evaluation, and triggers for evaluation of corrective action.
The analysis of groundwater samples will be performed by a laboratory certified
for applicable parameters in accordance with SCDHEC R.61-81, State
Environmental Laboratory Certification Program.
3.1.2 Identify Goals of the Study
The primary objective of the SAP is to develop the sampling design and data quality
objectives in support of the detection monitoring program outlined in the approved
GWMP. The FTF GWMP establishes a monitoring program to support evaluation of
groundwater conditions at the FTF during the interim period from the time the individual
waste tanks and ancillary equipment are removed from service and the final closure of the
FTF OU.
3.1.3 Identify Information Inputs
Historical groundwater data have been reviewed and summarized previously in this SAP
(see Section 2.4). The data are of sufficient quality to make decisions concerning
groundwater quality. Groundwater monitoring results collected from the monitoring
network as described in the FTF GWMP will be evaluated to determine groundwater
conditions at FTF. The FTF GWMP includes a network of thirteen (13) monitoring wells
consisting of seven (7) existing wells and six (6) newly installed wells (Figure 9); twice-
a-year collection of routine groundwater samples and analyses from the monitoring well
network around the FTF; and preparation and submittal of an annual groundwater report
that documents the current state of groundwater quality at the FTF.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 13 of 48
3.1.4 Define the Boundaries of the Study
The study area is approximately 22 acres on which the FTF resides within F Area within
the GSA (Figure 2). The area being monitored is heavily industrialized with many
operational areas and FFA OUs.
The UAZ and LAZ of the UTRA are the primary hydrostratigraphic units that are to be
monitored as part of this SAP.
3.1.5 Develop the Analytical Approach
Consistent with the FTF GWMP (SRNS 2012b), implementation of the FTF SAP will be
guided by the following accepted SRS protocols/procedures:
Samples will be analyzed using laboratories certified for applicable parameters in
accordance with SCDHEC R.61-81, State Environmental Laboratory
Certification Program (SCDHEC 2002).
Wells will be installed in accordance with SCDHEC Well Standards and
Regulations and with SRS site wide procedures found in Manual 3Q1
Hydrogeologic Data Collection Procedures and Specifications (SRNS 2010).
Samples will be collected, packed and shipped in accordance with the site wide
procedures found in Manual 3Q1 Hydrogeologic Data Collection Procedures and
Specifications (SRNS 2010).
Data management for the FTF groundwater monitoring program will be
performed in accordance with the Environmental Restoration Data Management
System (ERDMS) Data Management Plan (Q-DMP-B-00001, Revision 3, June
2006 or most current version). ERDMS will be used for database management
including mobilization, field measurements and analytical data.
The Quality Assurance Program is described in Area Completion Projects
Programmatic Quality Assurance Project Plan for Environmental Data
Collection and Management, ERD-AG-2005-00001, Rev.5.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 14 of 48
The decision rules associated with the data evaluation are defined below.
If screening for gross alpha or nonvolatile beta results exceeds trigger levels, then
the appropriate alpha, beta, and/or gamma spectroscopy analyses will be
performed. The trigger levels for groundwater are 15 pCi/L gross alpha and 50
pCi/L nonvolatile beta.
As outlined in the FTF GWMP, if analysis yields results at or above 15 pCi/L for
gross alpha, new samples will be collected and analyzed for specific radionuclides
to determine the cause of the elevated alpha results, and to distinguish USDOE
program-added radioactivity from natural background (such as radon-thoron). If
the primary FTF process alpha emitters, which include americium-241,
plutonium-238, plutonium-239/240, and uranium-238 are not detected, then
additional constituents will be evaluated, including any of those constituents listed
as contaminant migration constituents of concern in the FTF PA.
If analysis yields at or above 50 pCi/L for nonvolatile beta, new samples will be
collected and analyzed for specific radionuclides in order to determine the cause
of the elevated nonvolatile beta results. Mobile beta emitters (such as cesium-
137, cobalt-60, iodine-129, strontium-90, and technetium-99), present in the tank
inventories, will be evaluated first. If none of these radionuclides are detected,
samples will be analyzed for other constituents until the radionuclide responsible
for the elevated nonvolatile beta results is identified. It will then be added to the
monitoring list for that well.
As described in Sections 6.5 and 6.6 of the FTF GWMP, data will also be
evaluated and reported for comparison with risk-based thresholds and/or MCLs
and statistically evaluated to monitor for trends in contaminant concentrations. If
it is determined that there is a release occurring upgradient of the FTF, SRS will
report this situation promptly to EPA and SCDHEC. Data scoping meetings may
be called to review data findings with EPA and SCDHEC annually, or as needed.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 15 of 48
If the monitoring well network is insufficient for monitoring groundwater
contamination in the UAZ and LAZ, additional permanent monitoring wells may
be installed. As described in Sections 6.5 and 6.6 of the FTF GWMP, data
evaluations will be performed to evaluate compliance with risk-based thresholds
and/or MCLs, trending of contaminant concentrations, and to evaluate upgradient
sources. If the data evaluation identifies a concern, subsequent meetings may be
arranged to review the data and determine a pathforward, and as needed,
additional wells may be identified to further enhance monitoring at the FTF.
3.1.6 Specify Performance or Acceptance Criteria
According to USEPA guidance (USEPA 2006), “The USEPA has developed the DQO
Process as the Agency’s recommended planning process when environmental data are
used to select between two or more alternatives or to derive an estimate of contamination.
The DQO process is a seven step method designed to ensure that the appropriate type,
quantity, and quality of environmental data are collected for the intended application.
SW-846 methods (USEPA) are analytical procedures for sample analyses and are
presented in the Analytical Plan, Section 5. Section 4 presents DQO worksheets
developed for each subunit and/or media and specifies the quantity, type, and quality, of
data as well as ensuring representative data is collected for each sampling population.
Total study error is the additive impact of two main sources of error: 1) sampling error
and 2) measurement error, with sampling error being responsible for the vast majority of
the total error. “As much as 90% or more of the uncertainty in environmental data sets is
due to sampling variability as a direct consequence of the heterogeneity of the
environmental matrices” (Crumbling et al 2001). The method best suited to reduce
sampling error is to gather representative samples (Crumbling et al 2001).
It is incorrect to assume that randomly collected, non-representative samples, plus perfect
analytical chemistry will always lead risk managers to correct risk management
decisions. In order to avoid incorrect risk management decisions, it is more important to
develop Decision Quality Data (DQD). DQD is defined as data of known quality that can
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 16 of 48
logically be demonstrated to be effective for making the specified decision because both
the sampling and analytical uncertainties are managed to the degree necessary to meet
clearly defined and stated data needs (Crumbling et al 2001). Therefore, it is more
important for the risk managers to use decision quality data, emphasizing representative
sampling with a specified percentage of definitive data, in order to make a correct
decision and should not be confused by emphasizing analytical data quality which does
not necessarily equate to a correct risk management decision.
The DQOs for the FTF represent the type and level of analytical quality needed for
groundwater monitoring at this area and can be found in Sections 4 and 5 of this SAP.
3.1.7 Develop the Plan for Obtaining the Data (Project Quality Objectives)
The monitoring approach uses a layered scheme that considers the results of the previous
groundwater sampling data. Activities under this SAP include continued groundwater
monitoring of existing, newly installed monitoring wells, and background wells as
described in the FTF GWMP (SRNS 2012b). Split samples collected in support of
continued groundwater monitoring will be performed by SRS Field or subcontractor
personnel.
Project quality objectives (PQOs) are qualitative and quantitative statements derived from
the DQO process and are used as the basis for establishing the quality and the quantity of
data needed to support decisions. The PQOs for the FTF include the following:
Relative percent difference (RPD) < 100% between regular groundwater samples
and field duplicates when the groundwater sample result >= MDL but < sample-
specific estimated quantitation limit (ssEQL) for the precision data quality
indicator (DQI).
RPD <100% when groundwater sample result >=method detection limit but
<ssEQL for the precision DQI.
Percent Recovery from Matrix Spike and Matrix Spike Duplicates are generally
>= 135% or < 30% for accuracy/bias data quality indicator. Matrix Spike
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 17 of 48
recovery windows may be tighter than those listed. Tables 12 and 28 of the
Quality Assurance Project Plan (QAPP) list the general and analyte/media
specific Matrix Spike and Matrix Spike Duplicate recovery limits for various
analytical classifications (i.e., VOCs, SVOCs, etc.) as well as the frequency of
sampling which is by reference to Area Completion Projects Standard Operating
Procedure Analytical Data Qualification (ER-SOP-033).
No target compound >=ssEQL for equipment blanks, field blanks, method blanks,
or instrument blanks for the accuracy DQI.
ssEQL <MCL, RSL, or PRG for the sensitivity DQI.
Split sample result will have an RPD = 100% for groundwater samples.
5% of the samples will be split samples for the comparability DQI.
95% of the samples sent to the laboratory will have useable (non-rejected) results
for the completeness DQI.
90% of the planned samples will be collected and their data will be useable for the
completeness DQI.
The objective for the representativeness DQI is qualitative and will be met by properly
documenting field and analytical protocols. In the event these procedures and methods
are not able to be implemented, the appropriate corrective action documentation should
encompass the impact on the representativeness of the information. When review of the
data and documentation determines the data to be non-representative, the information is
qualified for use or is not used by the project.
4.0 SAMPLING DESIGN AND RATIONALE
Implementation of this SAP to obtain decision quality data for groundwater is
documented in the remaining sections of this sampling and analysis plan. The following
section describes how the plan is implemented to collect the physical data to meet the
criteria developed during the DQO process. A DQO worksheet was developed for the
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 18 of 48
groundwater at the FTF which specifies the quantity, type, and quality of data and
ensures representative data are collected for each sampling population (Table 1).
4.1 Rationale for FTF Groundwater Sample and Analysis Plan
As described in the FTF GWMP, six (6) groundwater wells were installed at five (5)
locations around the FTF (Figure 9). One location is a new background well cluster
consisting of a two (2) well cluster with a well completed in the UAZ and LAZ. These
wells will serve to provide needed data on current and future potential releases from the
FTF or to determine potential upgradient groundwater releases that may impact
groundwater quality downgradient at the FTF.
Of the four (4) remaining wells, two (2) were completed in the UAZ to the northwest of
the FTF to monitor groundwater flow towards Upper Three Runs Creek. The remaining
two (2) wells were completed in the LAZ to the southwest of the FTF to monitor
groundwater flow towards Fourmile Branch. The LAZ wells are located further from the
FTF since contaminants would be more likely to be present in the LAZ after they had
traveled some distance. The downgradient wells are intended to monitor the quality of
groundwater exiting the tank farm.
The installation of these well clusters was based on the diverging flow paths in the UAZ
and LAZ due to the location of the FTF on the groundwater divide and insufficient
groundwater monitoring in these areas (Figure 4). Additionally, groundwater modeling
in support of the PA for the FTF has indicated groundwater flow in these directions in the
event contaminants were released from the FTF. The installation of these new wells
along with the existing monitoring wells around the FTF will provide sufficient coverage
to detect any releases that may occur at the FTF.
4.1.1 Groundwater Sampling of Newly Installed and Existing Monitoring Wells
As described in the FTF GWMP, a total of thirteen monitoring wells (8 UAZ and 5
LAZ), will be sampled twice-a-year for nitrate/nitrite, cadmium, chromium, manganese,
sodium, gross alpha, nonvolatile beta, and tritium (Figure 9 and Tables 2 and 3).
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 19 of 48
Additionally, technetium-99 will be sampled and analyzed in only four (4) wells (two [2]
background and two [2] downgradient), to provide downgradient quality on existing
technetium-99 activities and to establish background groundwater quality.
The analytes identified were chosen based on the most prominent chemical and
radiological species present in the FTF during operations, waste removal, and tank
closure activities.
The list of analytes, along with their contract-required detection limits (CRDLs), MCLs,
and RSLs, is shown in Tables 4 and 5.
4.1.2 Data Evaluation
Data collected as a result of this Sample and Analysis Plan will be evaluated as outlined
in the FTF GWMP.
4.1.3 Reporting
As provided in the FTF GWMP, monitoring results will be reported on a calendar year
basis in an Annual Groundwater Monitoring Report for the F- and H-Area Radioactive
Liquid Waste Tank Farms to be submitted by March 31 of each year beginning in
calendar year 2013.
5.0 ANALYTICAL PLAN
This section describes the data quality levels for each type of data being collected. All
data collected under this SAP will follow the Area Completion Projects Quality
Assurance Project Plan for Environmental Data Collection and Management (QAPP)
(SRNS 2012a). The data quality level is determined by the intended use of the data.
Groundwater data will be collected under this SAP.
Groundwater data are needed to continue groundwater monitoring at the FTF during the
interim period from the time the individual waste tanks and ancillary equipment are
removed from service and final closure of the FTF OU. Groundwater data collected
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 20 of 48
under this SAP will be compared to various risk-based screening criteria (i.e., MCLs,
radiological PRGs, and RSLs) and evaluated per the data evaluation process described in
the FTF GWMP.
5.1 Data Quality Levels
All (100%) of the off-site laboratory analyses for groundwater samples collected at the
FTF wells will be verified and validated (VV). In addition, 10% of the VV samples will
have supplemental validation to meet more stringent definitive data criteria. Definitive
data are analytical data that are suitable for final decision making, including data used for
human health risk assessments (Table 6). Table 7 lists the specific methods and detection
limits for analytical analysis in groundwater. Table 8 lists the method and quantitation
limits for radiological analysis. Table 9 lists hold times, preservatives, and sample
containers for analysis conducted on groundwater samples collected from wells at the
FTF.
Regardless of data usage, laboratory quality assurance/quality control (QA/QC) samples
will be performed as specified in ACP Standard Operating Procedure Analytical Data
Qualification (ER-SOP-033) and ACP Programmatic Quality Assurance Project Plan for
Environmental Data Collection and Management (ERD-AG-2005-00001). Sufficient
quantity of sample will be collected to ensure laboratory QA/QC samples are performed
and reported.
5.2 Field Analytical Sampling Quality Assurance/Quality Control
All field analytical sampling quality assurance/quality control (QA/QC) will be
maintained through the use of QA/QC samples consisting of field duplicates,
rinsate/equipment blanks, field blanks, trip blanks, and split samples. Field personnel
will ensure that QA/QC samples are collected at the correct frequency and methodology
as described below.
Field quality assurance/quality control will be maintained through the use of QA/QC
samples and methods as described below:
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 21 of 48
1. Field Duplicate (co-located) Samples: Two or more independent samples collected
from side-by-side locations at the same point in time and space so as to be considered
identical. These separate samples are intended to represent the same population and
are carried through all steps of the sampling and analytical procedures in an identical
manner. These samples are used to assess precision of the total method, including
sampling, analysis, and site heterogeneity. Field duplicate samples are planned at a
combined minimum rate of 5% according to Obtaining and Managing Data for Area
Completion Projects (ACP) (ER-SOP-043), or typically 1 per 20 samples and
analyzed for the same parameters as the associated samples.
2. Equipment Blank: A sample of water free of measurable contaminants poured over or
through decontaminated field sampling equipment that is considered ready to collect
or process an additional sample. The purpose of this blank is to assess the adequacy
of the decontamination process. Also called rinse blank or rinsate blank. Equipment
blanks are typically planned at a rate of 1 blank per 40 samples.
3. Field Blank: A blank used to provide information about contaminants that may be
introduced during sample collection, storage, and transport; also a clean sample
exposed to sampling conditions, transported to the laboratory, and treated as an
environmental sample. Field blanks are optional and may be collected when
contamination from external environmental sources is anticipated by the project team.
Typically field blanks, when used, are planned at a rate of 1 blank per 40 samples.
4. Trip Blank: A clean sample of water free of measurable contaminants that is taken to
the sampling site and transported to the laboratory for analysis without having been
exposed to sampling procedures. Trip blanks are analyzed to assess whether
contamination was introduced during sample shipment (typically analyzed for volatile
organic compounds only). A blank consists of distilled-deionized water provided by
the laboratory to be placed in every cooler with volatile organic compounds samples
typically at the rate of 1 trip blank per cooler.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 22 of 48
5. Split Samples: Two or more representative portions from a sample in the field,
analyzed by at least two different laboratories and/or methods. Prior to splitting, a
sample is mixed (except volatiles, oil and grease, or when otherwise determined) to
minimize sample heterogeneity. These are quality control samples used to assess
precision, variability, and data comparability between laboratories. Split samples are
planned at a combined minimum rate of 5% or typically 1 per 20 samples and
analyzed for the same parameters as the associated samples.
5.3 Sample Matrix Table
Table 3 provides a sampling matrix table that includes the following information:
sample count,
station identifier,
aquifer,
sample type,
sample media
sample collection method,
analytical suites, and
coordinates*.
*Proposed coordinates may change as necessary due to field conditions.
5.4 Sample Location Map
A map showing the proposed groundwater monitoring well sample locations are shown
on Figure 9.
6.0 FIELD IMPLEMENTATION
The following sections outline the field implementation procedures and processes for the
FTF SAP. Additional implementing documents, such as the environmental checklist,
automated hazard analysis, safe work permits, radiological work instructions,
site-specific health and safety plan, and investigation derived waste (IDW) management
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 23 of 48
plans, are internal to SRS and detail day-to-day sampling operations and safety
requirements.
6.1 List of Sampling/Collection Equipment
The types of sampling/collection equipment needed to execute the field implementation
plan are as follows:
Portable/hand-held pH meter,
Portable/hand-held Conductivity meter,
Portable/hand-held Turbidity meter,
Portable/hand-held Water Level Indicator,
KIJ-5 Radio, cell phone, and/or pager,
Field vehicle,
Personal protective equipment,
Chain-of-custodies,
Sampling supplies,
Sample bottles with preservatives,
Coolers and frozen blue ice or equivalent for packing samples in the field.
Equipment needs will vary from day to day based on sampling requirements and field
conditions.
6.2 Investigation Derived Waste
IDW will be managed according to the site-specific IDW management plan developed for
the project.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 24 of 48
7.0 REFERENCES
Aadland, R.K., J.A. Gellici, and P.A. Thayer, 1995. Hydrogeologic Framework of West-
Central South Carolina, Report 5, Water Resources Division, South Carolina Department
of Natural Resources, Columbia, SC
Crumbling, Deana M., C. Groenjes, B. Lesnik, K. Lynch, J. Shockley, J. Van Ee, R.
Howe, L. Keith, and J. McKenna, 2001. “Managing Uncertainty in Environmental
Decisions”, Environmental Science & Technology, 2001, American Chemical Society,
October 1, 2001, pages 405A-409A.
FFA, 1993. Federal Facility Agreement for the Savannah River Site, Administrative
Docket Number 89-05-FF (Effective Date: August 16, 1993)
Garvin, R.G., W.L. Poe, 1975. Soil Contamination Adjacent to Tank 8-F, DPSPU-75-11-
8, E.I. du Pont de Nemours & Company, Savannah River Plant, Aiken, SC.
Grant, M.W., P.W. Weimorts, 1986. Results of Tank 8 Plume Study, DPST-86-511, E.I.
du Pont de Nemours & Company, Savannah River Plant, Aiken, SC.
Odum, J.V., 1976. Soil Contamination Adjacent to Waste Tank 8, DPSPU-76-11-4, E.I.
du Pont de Nemours & Company, Savannah River Plant, Aiken, SC.
Rucker, G.G., 2001. Calculation of the Isotopic Activities of Naturally Occurring
Uranium in Drinking Water Equivalent to Uranium Maximum Contaminant Level, Q-
CLC-B-00019, Revision 1 and ERTEC-2001-0001, Westinghouse Savannah River
Company, Savannah River Site, Aiken, SC.
SCDHEC, 2002. R.61-71, Well Standards and Regulations (April 26)
SCDHEC, 2011. R61-81, State Environmental Laboratory Certification Program
(September 23)
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 25 of 48
SRNS, 2010. Manual 3Q1, Hydrogeologic Data Collection Procedures and
Specifications, Sections 3000 and 9000, latest revisions, Savannah River Nuclear
Solutions, LLC, Savannah River Site, Aiken, SC
SRNS, 2011a. Savannah River Site Approved Site Treatment Plan, 2011 Annual Update
(U), SRNS-TR-2008-00101, Revision 3, Savannah River Nuclear Solutions, LLC, Aiken,
SC.
SRNS, 2011b. Scoping Summary for the General Separations Area Western
Groundwater Operable Unit (U), ERD-EN-2005-0127, Savannah River Nuclear
Solutions, LLC, Savannah River Site, Aiken, SC, August 2011.
SRNS, 2012a. Area Completion Projects Programmatic Quality Assurance Project Plan
for Environmental Data Collection and Management, ERD-AG-2005-00001, Revision 5,
Savannah River Nuclear Solutions, LLC, Savannah River Site, Aiken, SC.
SRNS, 2012b. F-Area Tank Farm Groundwater Monitoring Plan (U), SRNS-RP-2011-
00995, Revision 1, Savannah River Nuclear Solutions, LLC, Savannah River Site, Aiken,
SC.
SRNS, 2012c. 2011 Annual Groundwater Monitoring Report for the F- and H-Area
Radioactive Liquid Waste Tank Farms (U), SRNS-RP-2012-00022, Revision 0, Savannah
River Nuclear Solutions, LLC, Savannah River Site, Aiken, SC.
SRR, 2010a. Performance Assessment for the F-Area Tank Farm at the Savannah River
Site, SRR-CWDA-2007-00002, Revision 1, Savannah River Remediation, LLC,
Savannah River Site, Aiken, SC.
SRR, 2010b. Annual Radioactive Waste Tank Inspection Program - 2009, SRR-STI-
2010-00283, Savannah River Remediation, LLC, Savannah River Site, Aiken, SC, June
2010.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 26 of 48
SRR, 2011. Industrial Wastewater General Closure Plan for F-Area Waste Tank
Systems, LWO-RIP-2009-00009, Revision 2, Savannah River Remediation, LLC,
Savannah River Site, Aiken, SC.
USEPA, USDOD, USDOE, 2005. Uniform Federal Policy for Quality Assurance
Project Plans, EPA:-505-B-04-900A, Version 1 Final, March 2005.
USEPA, 2006. Guidance on Systematic Planning Using the Data Quality Objectives
Process, EPA QA/G-4, EPA/240/B-06/001, February 2006.
USEPA, 2009. Statistical Analysis of Groundwater Monitoring Data at RCRA Facilities,
EPA 530/R-09-007, March 2009.
USEPA, 2011a. National Primary Drinking Water Regulations, Office of Groundwater
and Drinking Water, http://www.epa.gov/safewater/contaminants/index.html (August).
USEPA, 2011b. USEPA Preliminary Remediation Goals for Radionuclides, http://epa-
prg-ornl.gov/radionuclides/ (August).
USEPA, 2011c. USEPA Regional Screening Levels, http://epa.gov/reg3hwmd/risk/hu-
man/rbconcentration_table/ index.htm (June).
USEPA, Various Updates. Test Methods for Evaluating Solid Waste, Physical/Chemical
Methods, SW-846, Third Edition Basic Manual with Updates.
WSRC, 1991. Assessment Report Phase II for the F and H-Area High-Level Radioactive
Waste Tank Farms (U), WSRC-RP-93-549, Revision 0, Westinghouse Savannah River
Company, Savannah River Site, Aiken, SC, August, 1991.
WSRC, 1993, Assessment of Tritium in the Savannah River Site Environment, WSRC-
TR-93-214, Westinghouse Savannah River Company, Savannah River Site, Aiken, SC.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 27 of 48
WSRC, 1994. Annual Radioactive Waste Tank Inspection Program – 1993 (U), WSRC-
TR-94-166, Westinghouse Savannah River Company, Savannah River Site, Aiken, SC,
May, 1994.
WSRC, 2001. Assessment Report: Groundwater Quality Near F- and H-Area Inactive
Process Sewer Lines (U), WSRC-RP-2001-4055, Revision 0, March 2001.
Westinghouse Savannah River Company, Savannah River Site, Aiken, SC.
WSRC, 2004. RCRA Facility Investigation/Remedial Investigation (RFI/RI) Phase 1
Work Plan for the General Separations Area (GSA) Western Groundwater Operable Unit
(U), WSRC-RP-2003-4147, Revision 1.1, November 2004. Westinghouse Savannah
River Company, Savannah River Site, Aiken, SC.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 28 of 48
FIGURES
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 29 of 48
Figure 1: Location of F Area in the General Separations Area at the Savannah River Site
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 30 of 48
Figure 2: Location of the F-Area Tank Farm at F Area, SRS
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 31 of 48
Figure 3: Hydrostratigraphic Units at F Area (modified from Aadland et al, 1995)
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 32 of 48
Figure 4: Potentiometric Surface and Groundwater Flow Directions at the F-Area Tank Farm
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 33 of 48
Figure 5: Surface and Groundwater Flow at the General Separations Area (modified from SRR, 2011)
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 34 of 48
Figure 6: Location of FFA OUs and Key Facilities at the F-Area Tank Farm
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 35 of 48
Figure 7: Historical Nonvolatile Beta and Technetium-99 Activities in Monitoring Well FTF 28
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 36 of 48
Figure 8: Location of UAZ and LAZ Wells At and Near the F-Area Tank Farm
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 37 of 48
Figure 9: Location of Wells for the F-Area Tank Farm Groundwater Monitoring Network
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 38 of 48
TABLES
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 39 of 48
Table 1: Data Quality Objectives Worksheet for Groundwater at the F-Area Tank Farm
Pathway (Media)
Probable Conditions
Exposure Pathway and/or Release Mechanisms
Data Needs and DQOs Including
Engineering/Physical Processes
Field Activities Including Removal and
Characterization Parameters
Potential Remedial Action
Alternatives
Groundwater
Contamination of groundwater from leaching of secondary sources and spills from primary sources (i.e., waste tanks). Contaminated groundwater elevated above risk-based screening criteria exists. Known technetium-99 activities are present in a downgradient LAZ well. Varying shallow subsurface groundwater flow directions and rates result in multiple flow paths.
Ingestion or dermal contact with groundwater or inhalation of groundwater vapor.
Establish permanent monitoring locations in the UAZ and LAZ to monitor and evaluate groundwater contaminant concentration trends. Obtain groundwater data needed to adequately monitor possible contaminant release and movement in the groundwater. Establish and monitor background groundwater locations for data comparisons to upgradient groundwater quality at the FTF.
Sample monitoring wells in the UAZ and LAZ to monitor groundwater in the northwest and southwest vicinity of the FTF.
Nitrate/nitrite, cadmium, chromium, manganese, sodium, gross alpha, nonvolatile beta, and tritium. Technetium-99 for a select number of wells. Alpha, beta, and/or gamma speciation, if trigger levels exceeded for gross alpha (15 pCi/L) and/or nonvolatile beta (50 pCi/L), as required.
No remedial actions are warranted. Semi -annual sampling of groundwater monitoring wells and annual reporting will continue.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 40 of 48
Table 2: Monitoring Parameters for the F-Area Tank Farm Groundwater Monitoring Plan Proposed Analytes for
Existing and New Wells (2 times/year)‡
Current Monitoring
Program Analytical Method
MCL/PRG (pCi/L,
pCi/mL, mg/L)
Action Level
CRDL/Typical MDA
Inorganics
Nitrate/Nitrite X EPA353.2 10 mg/L NA 0.01 mg/L (3)
Metals
Cadmium EPA6010C 0.005 mg/L NA 0.002 mg/L (3)
Chromium X EPA6010C 0.1 mg/L NA 0.002 mg/L (3)
Manganese EPA6010C NA NA 0.002 mg/L (3)
Sodium X EPA6010C NA NA 0.002 mg/L (3)
Radionuclide Indicators
Gross Alpha X EPA900.0MOD NA 15 pCi/L Sample Specific (2)
Nonvolatile Beta X EPA900.0MOD NA 4 mrem Sample Specific (2)
Radionuclides
Technetium-99 Beta Spectroscopy (1) 900 pCi/L NA 17.3 pCi/L (3)
Tritium X EPA906.0MOD 20 pCi/mL NA 0.5 pCi/mL (3)
Alpha Speciation (if gross alpha > 15 pCi/L)
X Alpha Spectroscopy (1) NA NA See Table 5 for selected isotopes
Beta Speciation (if nonvolatile beta > 50 pCi/L)
X Beta Spectroscopy (1) NA NA See Table 5 for selected isotopes
Gamma Speciation (if nonvolatile beta > 50 pCi/L)
X Gamma Spectroscopy (1) NA NA See Table 5 for selected isotopes
Proposed Field Parameters (1) No nationally recognized standardized methods, except Ra-226 and Ra-288 (EPA903.0MOD). (2) All minimum detected activities (MDAs) are on a sample specific basis, typical MDA for selected isotopes are provided in Tables 7 and 8, limits are not always attainable. (3) Contract Required Detection Limits (CRDL) are not always attainable. ‡The Analyte List includes radionuclides for information only.
Depth to Water X
pH X
specific conductance X
temperature X
turbidity X
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 41 of 48
Table 3: Sampling Matrix Table
Sample Coordinates
SampleCount
Station ID Aquifer Sample
Type Sample Media
Collection Method
Analyte Suite East North
1 FBG001Ca‡ LAZ REG Groundwater pump 1, 2, 3, 4, 5, 6 437085.697 3682792.647
2 FBG001Ca‡ LAZ SPL Groundwater pump 1, 2, 3, 4, 5, 6 437085.697 3682792.647
3 FBG001Da‡ UAZ REG Groundwater pump 1, 2, 3, 4, 6 437080.544 3682795.76
4 FTF 9Ra UAZ REG Groundwater pump 1, 2, 3, 4, 6 436707.182 3682662.677
5 FTF 12Ra UAZ REG Groundwater pump 1, 2, 3, 4, 6 436784.44 3682609.82
6 FTF 19 UAZ REG Groundwater bail 1, 2, 3, 4, 6 436869.32 3682598.5
7 FTF 20 UAZ REG Groundwater bail 1, 2, 3, 4, 6 436849.6 3682537.37
8 FTF 22 UAZ REG Groundwater bail 1, 2, 3, 4, 6 436895.58 3682471.46
9 FTF 23 UAZ REG Groundwater bail 1, 2, 3, 4, 6 436961.39 3682466.79
10 FTF 28 LAZ REG Groundwater pump 1, 2, 3, 4, 5, 6 436731.599 3682536.215
11 FTF 28 LAZ FD Groundwater pump 1, 2, 3, 4, 5, 6 436731.599 3682536.215
12 FTF 29 LAZ REG Groundwater pump 1, 2, 3, 4, 6 436637.736 3682655.337
13 FTF 30a LAZ REG Groundwater pump 1, 2, 3, 4, 5, 6 436819.72 3682464.84
14 FTF 30D UAZ REG Groundwater pump 1, 2, 3, 4, 6 436820.59 3682467.06
15 FTF 31a LAZ REG Groundwater pump 1, 2, 3, 4, 6 436977.29 3682429.94
‡Background Well
aNew well installed per the FTF GWMP.
REG = Regular sample. FD = Field duplicate. SPL = Split sample.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 42 of 48
Table 3: Sampling Matrix Table (Continued)
Regular and QA Sample
Summary for Monitoring
Wells
Comments
RegularSamples 13
FieldDuplicates 1 Collect at 1 per 20.
SplitSamples 1 Collect at 1 per 20.
RinsateSamples 0 None to be collected since sampling will be conducted using existing, dedicated downhole well pumps.
FieldBlank 0 Optional. None to be collected.
TripBlanks 0 None to be collected or shipped with samples since VOCs are not included in the analyte suite.
TotalSamples 15
QA = Quality assurance. Analytical Suites 1. Inorganics: Nitrate/Nitrite 2. Metals: Cadmium, Chromium, Managanese, Sodium 3. Radionuclide Indicators: Gross Alpha and Nonvolatile Beta
b 4. Radionuclides: Tritium 5. Radionuclides: Technetium-99 6. Field Parameters: Depth to Water, pH, specific conductance, temperature, and turbidity b If the gross alpha result exceeds 15 pCi/L, then an alpha spectroscopy will be performed to include americium-241, plutonium-
238, plutonium-239/240, and uranium-238. If the nonvolatile beta result exceeds 50 pCi/L, then a beta/gamma spectroscopy will be performed to include iodine-129, strontium-90, cesium-137, cobalt-60, and technetium-99.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 43 of 48
Table 4: Laboratory Contract Required Detection Limits Compared to Regional Screening Levels for Surface or Groundwater Media
Tap Water RSL
MCL
CRDL
CRDL>
Analyte CAS (µg/L) (µg/L) (µg/L) MCL/RSL
Cadmium 7440-43-9 6.9E-03 5.0E00 2.0E+00 >RSL Chromium 7440-47-3 1.0E+02 2.0E+00 No Manganese 7439-96-5 8.8E+02 ! 2.0E+00 No Nitrate-Nitrite as Nitrogen NO3NO2 1.0E+04 1.0E+01 No Sodium 7440-23-5 2.0E+00 No
>RSL means CRDL is greater than the RSL
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 44 of 48
Table 5: Minimum Detected Activity Compared to Water Radiological MCL/PRGs
Analyte Typical MDA
MCL/PRG MDA>MCL/PRG
Proposed Analytes for Existing and
New Wells (2 times/year)
Alpha Spectroscopy (pCi/L)
Americium-241 0.4 15 No X
Americium-243 0.462 15 No
Curium-242 0.9 15 No
Neptunium-237 0.771 15 No
Plutonium-238 0.35 15 No X
Plutonium-239/240 0.353 15 No X
Plutonium-242 0.372 15 No
Thorium-228 0.445 15 No
Thorium-230 0.523 15 No
Thorium-232 0.45 15 No
Uranium-233/234 0.663 10 Noa
Uranium-235 0.684 0.47 Noa
Uranium-238 0.744 10 Noa X
Gamma Spectroscopy (pCi/L)
Actinium-228 25 26.6 No
Cesium-137 5 200 No X
Cobalt-60 10 100 No X
Lead-214 20 154 No
Potassium-40 75 2.14 Yes
Specific Analyses (pCi/L)
Carbon-14 10 2,000 No
Iodine-129 1 1 No X
Nickel-59 20 300 No
Nickel-63 10 50 No
Promethium-147 10 600 No
Radium-226 0.3 5 No
Radium-228 0.5 5 No
Strontium-90 0.852 8 No X
Technetium-99 17.3 900 No X
Tritium (pCi/mL) 0.5 20 No X aFrom Rucker 2001.
Note: All minimum detected activity (MDAs) are sample specific. The MDAs represented above are typical MDA as reported by the subcontract laboratories but are not always achievable.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 45 of 48
Table 6: Minimum Field Quality Control/Quality Assurance Sampling Requirements
Data Quality Level
Field Quality Control/Quality
Assurance Samples
Frequency of Field Quality Control/
Quality Assurance Sample
VV
Co-located Field Duplicate Minimum 5% (1)
Trip Blank Minimum 1 per cooler
Equipment Blank 1 per 40 samples(2)
Field Blank Optional; 1 per 40 samples(3)
Split Sample Minimum 5%
D
Co-located Field Duplicate Minimum 5%(1)
Trip Blank 1 per cooler
Equipment Blank 1 per 40 samples(2)
Field Blank Optional; 1 per 40 samples(3)
Split Sample Minimum 5%
Data Quality Levels VV Data Verified and Validated Data (validated to automated criteria; equivalent to USEPA
Screening Level Data) D Data USEPA Definitive Level Data Footnotes: (1) Minimum frequency established per ER-SOP-043 (2) Typical frequency (3) Recommended based on project needs; typical frequency
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 46 of 48
Table 7: Laboratory Analytical Specifications Table for TAL/TCL Analytes for Groundwater Media
Analyte
Analyte ID
Preparation B Method
Analytical B Method
CRDL A
(µg/L)
Metals Cadmium 7440-43-9 3005A,3015A EPA6010C 2.0 Chromium 7440-47-3 3005A,3015A EPA6010C 2.0 Manganese 7439-96-5 3005A,3015A EPA6010C 2.0 Sodium 7440-23-5 3005A,3015A EPA6010C 2.0
Inorganics Nitrate-Nitrite as Nitrogen NO3NO2 EPA353.2 10.0
A) CRDL is the Contract Required Detection Limit and is not always attainable. B) Extraction and preparation methods differ depending upon media, concentration, instrument, laboratory, and analytical method. Preparation methods will also influence detection limits.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 47 of 48
Table 8: Laboratory Analytical Specifications Table for Radiological Analytes in Soil, Sediment, Surface, and Groundwater Media
Radionuclides Typical Water
MDAsa Analytical
Method
Alpha Spectroscopy (pCi/L)
Americium-241 0.40 NNS Americium-243 0.462 NNS Curium-243/244 0.503 NNS Curium-245/246 0.458 NNS Neptunium-237 0.771 NNS Plutonium-238 0.35 NNS Plutonium-239/240 0.353 NNS Plutonium-242 0.372 NNS Thorium-228 0.445 NNS Thorium-230 0.523 NNS Thorium-232 0.45 NNS Uranium-233/234 0.663 NNS Uranium-235 0.684 NNS Uranium 238 0.744 NNS
Gamma Pulse Height Analyses (pCi/L)
Actinium-228 25.00 NNS Cesium-137 5.0 NNS Cobalt-60 10.00 NNS Lead-214 20.00 NNS Potassium-40 75.00 NNS
Radiological Indicators (pCi/L)
Gross Alpha 3 EPA900.0MOD Nonvolatile Beta 4 EPA900.0MOD
Individual Analyses (pCi/L) Carbon-14 10.00 NNS Iodine-129 1.00 NNS Nickel-59 20.00 NNS Nickel-63 10.00 NNS Promethium-147 10.00 NNS Radium-226 0.30 EPA903.0MOD Radium-228 0.50 EPA903.0MOD Strontium-90 0.852 NNS Technetium-99 17.3 NNS Tritium (pCi/mL) 0.00050 EPA906.0MOD
a All MDAs are sample-specific. The MDAs represented above are typical MDAs as reported by the subcontract laboratories but are not always achievable. MDA = Minimum detected activity. NNS = No national standard. USEPA = United States Environmental Protection Agency.
FTF Groundwater Sampling and Analysis Plan (U) SRNS-RP-2012-00287 Savannah River Site Revision 1 November 2012 Page 48 of 48
Table 9: Preservatives, Holding Times, and Sample Containers for Groundwater Collected at the FTF
Parameter Preservative Holding Time Container
Metals (except chromium [VI] and mercury)
HNO3 to pH <2 6 months 1-L HDPE
Miscellaneous
Nitrate-Nitrite Cool to 4○ C. H2SO4 to pH < 2. 28 days 250 mL HDPE
Radionuclides
Radiological Test Gross Alpha HNO3 to pH <2 6 months 2-L HDPE
Radiological Test Nonvolatile Beta HNO3 to pH <2 6 months 2-L HDPE
Radium Total HNO3 to pH <2 6 months 2-L HDPE
Tritium None, Cool 0 to 6°C 180 days 250-mL amber glass
°C = Degrees Celsius. H2SO4 = Sulfuric acid. HDPE = High-density polyethylene. HNO3 = Nitric acid.