extraction method for blood vessels, based on the velocity ......bg blood vessel frequency intensity...

18
Computer and Information Division The Institute of Physical and Chemical Research Extraction Method for Blood Vessels, Based on the Velocity Profile Measured by Phase Shift Method Y KATO R HIMENO

Upload: others

Post on 13-Oct-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Extraction Method for Blood Vessels,Based on the Velocity ProfileMeasured by Phase Shift Method

Y KATO R HIMENO

Page 2: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Computational Model-What is the most important?-

The Model is…

Reflecting the characteristics of the object

Constructed quantitatively.

Material Property

Geometry

Page 3: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Characteristics of Sequences-What does the signal mean ?-

PSThe phase shows the velocity.(Velocity=VENC*Phase/π)

TOFThe intensity is proportional to the velocity.(Relative Velocity)

To observe the blood vessel, PS and TOF are usually used:

Page 4: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Past Studies

The smoothness of the geometry has been receivedattention, because the histogram is so unique.

•••••> The setting of the threshold value is difficult.•••••>The accuracy could not be discussed.

TOF PS

Blood VesselTissue

BG

Blood VesselBG

Freq

uenc

y

Intensity

Page 5: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Purpose

•Investigate the accuracy of velocity measurement.

•Propose the extraction method of the blood vessel,based on the velocity.

The model is made, whose accuracy is known.

Page 6: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Accuracy of the VelocityMeasurement (PS Method)-Method-

Influences • • •Relaxation Time, TR, TE, VENC

All the measurements was done by 1.5 T EXCELART MR System(TOSHIBA Corporation, JAPAN).

T1 [msec]TR [msec]TE [msec]

VENC [cm/s]

5.6X102-2.5X103

50,10010,16Integer nearest to the Maximum Velocity

Reynolds number ResolutionDiameter of Vessel

3001mm/pixel8mm

Page 7: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Result

TR •••• no influence in the range T1, VENC••••• no influence in the range of 1.7X103-5.6X102 msecTE ••••• no influence, except T1= 1.7X103 (not the maximum error)

The maximum error was less than 10 %.

Page 8: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Dephasing Effect

00.20.40.60.8

11.21.41.6

0 1 2 3 4 5 6

系列1系列2系列3系列4系列5

00.20.40.60.8

11.21.41.6

1 2 3 4 5

系列1系列2系列3系列4系列5

Longitudinal Direction Transverse Direction

Dif

fere

nce

[cm

/sec

]

Page 9: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Discussion

Considering T1 of Blood is700 - 1500 msec:The value was not influenced by these parameters.Maximum error < 10 %

Measurements in PS images are reliable.

Page 10: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Extraction Method -PS Images-

The characteristics of this method:Using the continuity of the blood vesselThe data in the boundary is known.

What the operator have to do:Set the starting pointSet the minimum velocity in the blood vessel.

Page 11: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Example (Femoral Artery)

Page 12: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Example (Femoral Artery)

Binarized Image Original Image50mm

Page 13: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Example (Cerebral Artery)

Page 14: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Extraction Method-TOF Images-

The Starting point and the threshold valueare decided automatically.

Starting Point •••• 1- 100 points in the highest intensityThreshold Value •••• the frequency is 10 times higher atthe value.

Page 15: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Example (TOF)

Page 16: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Example (TOF)

Binarized Image Original Image

10mm

Page 17: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Conclusion

•PS method has enough accuracy to measure the blood flow.•The automatic extraction method was proposed, which couldbe evaluated quantitatively.•This extraction method could apply to PS and TOF images.

Page 18: Extraction Method for Blood Vessels, Based on the Velocity ......BG Blood Vessel Frequency Intensity Computer and Information Division The Institute of Physical and Chemical Research

Computer and Information Division The Institute of Physical and Chemical Research

Evaluate the geometrical data quantitatively and automatically

•Decide the centerline based on the reasonable assumption

Diameter, shear stress, …..