extended storage technical issues - energy.gov · (escp) • purpose: “provide the technical...
TRANSCRIPT
![Page 1: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/1.jpg)
John KesslerManager, Used Fuel and HLW Management Program
INMM Spent Fuel Management Seminar XXVIII16 January 2013
Extended Storage Technical Issues
![Page 2: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/2.jpg)
2© 2012 Electric Power Research Institute, Inc. All rights reserved.
Extended Storage – an International Issue
• Most “nuclear” countries face extended storage– No reprocessing– No disposal– Centralized (consolidated) storage is still storage
![Page 3: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/3.jpg)
3© 2012 Electric Power Research Institute, Inc. All rights reserved.
EPRI Initiates Extended Storage-specific Work in 2009
• Recognized need for international collaboration• Share existing information • Are there common technical issues for future technical
work?
• Identify specific industry needs for R&D
![Page 4: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/4.jpg)
4© 2012 Electric Power Research Institute, Inc. All rights reserved.
“Extended Storage Collaboration Program” (ESCP) Launched in 2009Bring together US and international organizations engaged with active or planned R&D
• Storage and transportation system vendors• Regulators and their R&D contractors • National waste management organizations • R&D organizations • Industry (utilities/cask vendors)
Currently >200 members from ~20 countries
![Page 5: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/5.jpg)
5© 2012 Electric Power Research Institute, Inc. All rights reserved.
EPRI Extended Storage Collaboration Program (ESCP)
• Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”
• Modeled on prior dry storage license extension research
• Phased approachPhase 1: Review current technical bases and conduct gap
analysis for storage systems Phase 2: Conduct experiments, field studies, and additional
analyses to address gaps (already underway)– Phase 3: Coordinate research that results in a program
documenting the performance of a dry storage system loaded with high burnup fuel (>45 GWd/MTU)
![Page 6: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/6.jpg)
6© 2012 Electric Power Research Institute, Inc. All rights reserved.
ESCP Subcommittees
• Fuel/Internals• “Marine environments”• Non-destructive evaluation (NDE)• Concrete Systems• High burnup confirmatory demonstration• “International”
• 2013: Aging Management– Build on ANL and industry work
![Page 7: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/7.jpg)
7© 2012 Electric Power Research Institute, Inc. All rights reserved.
Gap Analyses: Highest Priority Items
• Welded SS canisters SCC• High burnup cladding: hydride effects (reorientation,
embrittlement)• Bolted casks:
– Corrosion of bolts– Embrittlement and mechanical degradation of bolts
• Fuel pellet swelling
![Page 8: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/8.jpg)
8© 2012 Electric Power Research Institute, Inc. All rights reserved.
Cross-Cutting Needs
• Improved thermal modeling• Stress profiles• Degradation monitoring systems• Adequacy of drying• Sub-criticality: burnup credit• Examine casks at INL (DOE)• Retrievability: fuel transfer options
![Page 9: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/9.jpg)
9© 2012 Electric Power Research Institute, Inc. All rights reserved.
ESCP-Generated Collaboration
• Stainless steel dry storage canister field inspections (EPRI)– DOE providing co-funding and laboratory analysis
support (thermal, potentially more)• Laboratory experiments identifying conditions to support
SCC in SS– Initiated by CRIEPI– Several countries and programs expanding initial testing
• High burnup used fuel confirmatory data demonstration– Several years of discussion within ESCP – EPRI proceeding with a demo– DOE issues RFP
![Page 10: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/10.jpg)
10© 2012 Electric Power Research Institute, Inc. All rights reserved.
Field Inspections and Large-scale Testing
• In situ inspections of SS canisters• Full-scale, high burnup confirmatory data collection (the
“demo” program)
![Page 11: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/11.jpg)
11© 2012 Electric Power Research Institute, Inc. All rights reserved.
EPRI Plans for In Situ Inspection of SS Canisters
![Page 12: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/12.jpg)
12© 2012 Electric Power Research Institute, Inc. All rights reserved.
Inspection #1: Calvert Cliffs (June 2012)
• ISFSI ~ ½ mile from Chesapeake Bay
• Canisters in service for > 15 years
• Low decay heat canisters
• Two canisters were inspected– Aging management inspection for license renewal– Marine environment effects
![Page 13: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/13.jpg)
13© 2012 Electric Power Research Institute, Inc. All rights reserved.
General Inspection Plans
Scope of inspections:• Visual• Temperature• Surface contaminants
Additional data collection on environment• Air temperature & humidity• Salt content in air
![Page 14: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/14.jpg)
14© 2012 Electric Power Research Institute, Inc. All rights reserved.
Calvert Cliffs Visual Inspection through NUHOMS Air Outlets
Calvert Cliffs
NUHOMS Design
![Page 15: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/15.jpg)
15© 2012 Electric Power Research Institute, Inc. All rights reserved. 15
DSC Inspection Locations
Cold CanisterLead
Canister
Mockup Location
#1#15
#48
![Page 16: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/16.jpg)
16© 2012 Electric Power Research Institute, Inc. All rights reserved.
DSC-6 Top Cover Plate and Closure Weld
Both in good condition with no signs of corrosion
![Page 17: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/17.jpg)
17© 2012 Electric Power Research Institute, Inc. All rights reserved.
DSC-6 Lower East DSC Shell
Surface rust on scratched area near Top End
Possible carbon steel
contamination due to gouging
by tooling during
fabrication or handling
Est. 2.4”
![Page 18: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/18.jpg)
18© 2012 Electric Power Research Institute, Inc. All rights reserved.
Bottom DSC-6 Shell Between Rails
Light surface rust stain on near middle of DSC
![Page 19: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/19.jpg)
19© 2012 Electric Power Research Institute, Inc. All rights reserved.
Future SS Canister Inspection and Aging Management Plans
• Mid 2013:– Hope Creek (southern New Jersey shore, next to cooling
tower)– Diablo Canyon (West Coast)
• Potential third site
• Aging management– EPRI initiating FMEA (failure modes and effects
analysis) as first step in an industry-wide aging management plan
– New ESCP subcommittee
![Page 20: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/20.jpg)
20© 2012 Electric Power Research Institute, Inc. All rights reserved.
Full-scale, High Burnup Confirmatory Data Collection (“high burnup demo”) Plans
Confidence in understanding longer-term behavior of dry storage system requires
• Model development and benchmarking data• “Separate effects testing”• Confirmatory testing under “prototypic” conditions
– Full scale– Representative dry storage conditions
• Drying process and inerting• Thermal evolution• Geometry
– Prefer multiple high BU fuel types (if possible)
![Page 21: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/21.jpg)
21© 2012 Electric Power Research Institute, Inc. All rights reserved.
High Burnup Demo Option that Keeps Startup Time Short• Initiate the demo at a reactor site
– Avoids up-front transportation to a national lab– Avoids having to wait for a full-scale hot cell to be funded
and constructed– Keeps costs low(er) prior to test initiation
• EPRI-Dominion-TN (start test in ~3 years)– Willing host (North Anna)– Multiple, high burnup fuel types– Partner with a cask vendor supplying cask(s) at low cost– EPRI providing funding for instrumented lid design– NRC may waive license review fees– Looking for co-funding
![Page 22: Extended Storage Technical Issues - Energy.gov · (ESCP) • Purpose: “Provide the technical bases to ensure continued safe, long-term used fuel storage and future transportability”](https://reader034.vdocuments.site/reader034/viewer/2022042403/5f159bcf220ad728996759c6/html5/thumbnails/22.jpg)
22© 2012 Electric Power Research Institute, Inc. All rights reserved.
Together…Shaping the Future of Electricity