  • Express Vented point of use hot water

  • Hot supply

    NOTE:For cistern tank supplyminimum head must be 4m (13ft)measured from the outlet to thebottom of the supply tank.

    Cold feedfrom mains or

    cistern tank

    Service valveFlow restrictor(If used)

    Waterheater

    Open outlet hot tap Cold water tap

    Hot supply

    Coldfeed

    Seal dividinginlet and outletchambers

    Service valveFlow restrictor(If used)

    Coldmains

    feedWaterheater

    Hot supply

    NOTE:For cistern tank supplyminimum head must be 4m (13ft)measured from the outlet to thebottom of the supply tank.

    Cold feedfrom mains or

    cistern tank

    Service valveFlow restrictor(If used)

    Waterheater

    Open outlet hot tap Cold water tap

    Hot supply

    Coldfeed

    Seal dividinginlet and outletchambers

    Service valveFlow restrictor(If used)

    Coldmains

    feedWaterheater

    Typical oversink installation

    Express water heaters are designed for demanding

    commercial and industrial applications such as canteens

    and workshops.

    They have a tough metal case, making them easily capable of

    withstanding the rigours of daily use. You can choose from two

    capacities – 7 litres (with a 1kW or 3kW rating) or 15 litres (with a

    3kW rating) – so there’s a model to meet your needs.

    And, taking into account wide variety of possible uses, they are

    equally well-suited to oversink and undersink applications. Every

    Express water heater is backed by a two year guarantee with

    on-site service support.

    • Choiceof7or15litrecapacities.

    • 3kWrating(7litrealsoavailablein1kW).

    • Fastheatup(nineminutesfor50°Crisein7litre,3kWunit).

    • Completewithspoutandvalve.

    • Optionaltelescopicspout.

    • Thermostatadjustablefrom5°Cto75°C.

    • Drystartcut-out.

    • Rod-typealloysheathedelement.

    • Quickandeasyinstallation.

    Express

    Typical undersink installation

  • 181

    DA

    B

    358

    C

    ISO 9001:2008FM 01862

    BS OHSAS 18001:2007OHS 515891

    ISO 14001:2004EMS 556355

    Fullspecifications,dimensionsandordering

    Dimensions

    Model

    Express 7

    Express 15

    A

    (mm)

    499

    748

    B

    (mm)

    263

    263

    C

    (mm)

    250

    250

    D

    (mm)

    334

    583

    Weight

    empty full (kg) (kg)

    5 12

    8 23

    Ordering guideProduct

    code

    95:010:160

    95:010:161

    95:010:162

    95:970:103

    95:970:110

    Capacity

    (litre)

    7

    7

    15

    -

    -

    Rating @ 240V

    (kW)

    1

    3

    3

    -

    -

    Model

    Express 7

    Express 7

    Express 15

    Telescopicspout(380–610mm)

    15x15pushfitconnectorfor undersinkfitting

    SpecificationCapacities 7 and 15 litres.

    Rating 7litres–1kW,3kW@240V,(0.9kW,2.8kW@230V). 15litres–3kW@240V,(2.8kW@230V).

    Outer casing White stove enamelled corrosion resistant steel with white trim.

    Thermal insulationCFC/HCFCfree(ODPzero)flame-retardantexpandedpolystyrene.

    Water containerTestedto1.38bar(20psi).

    Heat unitRod-typealloysheathedelementmountedonadetachableplate.

    ThermostatCapillary-typethermostatadjustablefrom5°Cto75°C.

    Safety featuresDrystartcut-out.

    ApprovalsBEABandKiwaapprovedtoUKWaterSupplyRegulations.CEmarked.ManufacturedintheUKinaBSENISO9001:2008,ISO14001:2004and BSOHSAS18001:2007registeredfactory.

    InstallationFixingWall-mountingbythreekeyholefixingsusingscrewsandplugssupplied. A template is provided to assist in positioning.

    PlumbingSupplydirectfromrisingmainorcistern(minimumhead4m).Foroversinkinstallationstheinletconnectionusesa15mmcompressionfittingviavalveprovided.

    Outletspoutisapush-fit.

    Forundersinkinstallationconnectionsmustbefrombaseofunitusing15mmcompressionorpush-fitinletand15mmpush-fitoutletconnection.Streamlinevented tappacksJ,K,M,P,Q,R,S/T,W,XorYarealsorequiredforundersinkinstallation.

    NOTE:OnlyHeatraeSadiaventedtapsoraccessoriesmustbeusedwithExpressheaters.

    FortapspecificationspleaserefertoHeatraeSadia’sStreamlinebrochure.

    ElectricalCableentryinbaseofunit.Mustbepermanentlyconnectedtotheelectricalsupplythrough a double-pole linked isolating switch with a minimum rating of 13A (3kW models) or 5A (1kW model).

    Must conform to current IEE wiring regulations.

    GuaranteeExpress carries a full two year transferable on-site service support guarantee against faulty manufacture or materials provided that:

    • IthasbeencorrectlyinstalledaspertheinstructionscontainedintheinstructionmanualandallrelevantCodesofPracticeandRegulationsinforceatthetimeof installation.

    • IthasbeeninstalledintheUK.

    • Ithasnotbeenmodifiedinanyway,otherthanbyHeatraeSadiaHeating.

    • Thedamageisnotduetoscalingorfrost.

    • Ithasonlybeenusedforthestorageofpotablewater.

    • Ithasnotbeentamperedwithorbeensubjectedtomisuseorneglect.

    • Within60daysofinstallationtheusercompletesandreturnsthecertificatesupplied along with the proof of purchase to register the product.

    Evidence of purchase and date of supply must be submitted. The units are not guaranteed against damage due to frost. The guarantee is transferable. This guarantee does not affect your statutory rights.

    Specification Advice Hotline: 01603 420220 Email: [email protected]

  • HeatraeSadiaHeatingHurricaneWayNorwichNorfolkNR66EA

    HeatraeSadiaHeatingmayintroducemodificationstotheirproductsfromtimetotime.Consequently,thedetailsgiveninthisbrochurearesubjecttoalterationwithoutnotice.

    95900906Issue4©HeatraeSadiaHeating2012

    heateamisHeatraeSadia’sveryownservicedivision.With us on your side, you can be sure that your customers are in the very best hands. Totally committed to quality and safety, heateam is open 7 days a week, for 363 days a year, and offers:

    • Dedicated Trade Advice Line – our helpful and qualified specialists are always on hand to help you with even the most complex technical query.

    • Installer Priority Call-Outs–our280strongteamof specifically trained expert heating engineers covers the UK, no one is better qualified to look afterHeatraeSadia’sproductsfortheduration of the guarantee.

    • Fully Stocked Vans – a nationwide fleet of vans, fully stocked with spare parts – meaning we can repair our appliances on the first visit in 95% of call-outs.

    • Exclusive Service Plans – heateam also offer HeatraeSadia’scustomersarangeofexclusiveannual service plans.

    OpeningTimes:Monday-Friday8am-6pm,weekendsandBankHolidays*8.30am-2pm.*excludingChristmasDayandNewYear’sDay.

    Simply call 0844 8711535 or visit our website at www.heateam.co.uk

    PN95900906B

    JN202045

    ContactSpecification Advice Hotline

    T:01603420220F:01603420229 E: [email protected]

    After Sales Service

    T:08448711535F:08448711528 E: [email protected] Web www.heatraesadia.com

    Brochures for all of our products are availablefreeofcharge.Pleasecallourliteraturehotlineon01603420127.

    MEGAFLO ECO

    Megaflo eco cylinder range

    DOMESTIC HEATING AND HOT WATER

    Aerheat Amptec Electric Solar Electromax Electromax Solar ImmersionHeaters MegalifeHE Megalife Solar Multipoint Instantaneous

    COMMERCIAL HOT WATER

    B3M/C3M Express FBM Handy HandyDri/HairDrier Hotflo Multipoint Multipoint SS Streamline UTC99

    DRINKING WATER

    Aquatap SuperChill Supreme SupremeCounterTop