Solar Collector Description
* for the area of Würzburg - Germany
gross dimensions (L x B x H) 2005 mm x 1010 mm x 81 mm
heater 1080 mm
gross area 2,025 m²
absorber area 2,40 m²
total mass of collector without fluid 38,10 kg
fluid content 1,920 l
maximum temperature of operation 160,3 °C
maximum operation pressure 11 bar
absorbation 95% ± 2%
emition 5% ± 2% yearly energy output of the collector 560 kW/m² / yearly*
casing material aluminum
cover material 4 mm security prismatic glass
insulation 40 mm glasswool
number of tubes and tube diameter 10 x Ø 10 mm
connection 4 x Ø 22 mm
certificate EN12975-2 / ISO9806-1 / ISO9806 / Solar Keymark
C O L L E C T O R M A G I C S U N EKA2
200
5
200
5
81
1010
heavy-duty-flat collector for on-In and flat roof installation
solid aluminum frame
ten (10) year warranty
installation system sponsers a quick and easy installation
newly developed ventilation system
guaranteed mist-free
attractiv design of the collector (all arial colours avalible)
vertical and horizontaly use
combinible with all commen heating-systems and pools
C O L L E C T O R M A G I C S U N EKA2
Laboratory of testing
solar and other energy systems
''DEMOKRITOS''
solar Collector Description
(EN 12975-2 / ISO 9806-1 / ISO 9806)
1. basic data
-sales rep: Exhellios – E. Bellos & M. Mokas O.C
-manufacturer: Iliotechnothermiki O.C -collector model: MAGICSUN EKA2
2. collector
-gross area: 2,02 m² -gross dimensions: 2005x1010x81 mm
-aperture dimensions (a1 x b2): 1925 x 935 mm x mm
-absorber area (a2 x b2): 2,40 m² -typ of collector: flat plate
-total mass of collector without fluid: 38,1 kg -fluid content: 1,920 kg
-maximum operating pressure: 11 bar
-maximum temperature of operation: 160,3 °C
3. aperture
-number of covers: one (1)
-cover thickness (Lc): 4 mm -cover materials: prismatic security glass
-optical efficiency (τ): 88,5% τ
4.absorber
-absorber type: one piece aluminum sheet
-absorber material: copper tubes
-constraction type: omega -absorber thickness (δ): 0,40 mm
-surface treatment: high selective coating
-absorbation (α): 0,95 ± 0,02 at 100 °C
-emition (ε): 0,05 ± 0,02 at 100 °C
-material of tubes: copper
-number of tubes: (ten) 10
-tube diameter (outside) (da): 10,8 mm
-tube diameter (inside) (di): 10,0 mm
-tupe pitch (W): 97 mm
-heater diameter (outside) (da): 22 mm
-heater diameter (inside) (di): 20,4 mm
5. thermal insulation and casing
-insulation material, back: glasswool
thermal insulation density: 50kg/m³
thermal insulation thickness (Li1, Li2): 4 cm
Thermal condutivity (λb)*(in 10 °C): 0,032 W/m.K
-insulation material, sides: glasswool
thermal insulation density: 30kg/m³
thermal insulation thickness (Li1, Li2): 3 cm
Thermal condutivity (λb)*(in 10 °C): 0,33 W/m.K
-casing material, sides: aluminum 1,2 mm
-casing material, back: aluminum 0,5 mm
-sealing material: EPDM
rubber strip and silicone
6. sketch of the collector
tubes heater
absorber
cover
aperture
insulation,sides
casing insulation,back casing, back
a/a number description
1 1 galvanized
steel sheet
2 4 aluminum
4 plastic-corner
3 1 silicone
4 1 glasswool
5 1 absorber
10 heat exchanger pipe
1 absorber surface
2 heater
6 1 cover
1 plastic-frame
7 4 plastic-rosettes
101
MONTAGE-SET B2
Montage-Set B2
vertikal rod 40x40x200
horizontal rod 40x40x200
x 2
roof hook 40x5x 4
INSTALLATION - SET B2
Installation of two collectors MAGICSUN EKA2
step 1
step 2
Technical specification single coil floor standing boiler BLC-1
Material: steel sheet
Welding: automatic metal welding
Protection coating: high quality glass – enamel coating and protection anode
Maximum working pressure: 10 bar
Maximum working test pressure: 16 bar
Maximum operating temperature: 95°C
Insulation: polyurethane foam of 50mm thickness, density 40kg/m³
Coil: steel tube
Maximum coil test pressure: 25 bar
Electric heater: by order
Flange: diameter Ø170mm & Ø140mm
Volume L 150 200 250 300 500 600
Code BLC-1-A BLC-1-B BLC-1-C BLC-1-D BLC-1-E BLC-1-F
Coil S
input / outlet
1'' 1'' 1'' 1'' 1'' 1''
Coil
surface / m²
0,72 0,986 0,986 1,55 1,55 1,55
R ecirculation 3/4''(1/2'') 3/4''(1/2'') 3/4''(1/2'') 3/4''(1/2'') 1'' 1''
Cold water input 1'' 1'' 1'' 1'' 1'' 1 ½''
Hot water outlet 1'' 1'' 1'' 1'' 1'' 1 ½''
Anode - flange Ø140 Ø140 Ø140 Ø140 Ø140 Ø140
For connection to a boiler
with 90°C and water 10/45°C
KW/L/h
36
859
41,5
1018
41,5
1018
62,2
1528
62,2
1528
62,2
1528
A cold water input 212 192 230 260 260 270
J hot water outlet 884 1128 1235 1265 1265 1590
A coil input 212 192 230 260 260 270
C coil outlet 602 682 720 750 750 960
B recirculation 472 532 570 600 600 610
F electric resistance 400 400 400 400 400 400
H total height 1070 1340 1480 1480 1480 1810
E thermostat 818 1027 1070 1100 1100 1256
K thermometer 874 1138 1235 1265 1265 1590
G electrical resistance / socket - - 795 825 825 1011
D diameter Ø560 Ø560 Ø600 Ø600 Ø750 Ø750
Operation pressure / bar 10 10 10 10 10 10
Weight / kg 60 86 93 128 162 184
The electric resistance is an extra accessory and is being placed at the cleaning flange
Technical specification single coil floor standing boiler BLC-1
Material: steel sheet
Welding: automatic metal welding
Protection coating: high quality glass – enamel coating and protection anode
Maximum working pressure: 10 bar
Maximum working test pressure: 16 bar
Maximum operating temperature: 95°C
Insulation: polyurethane foam of 100mm thickness, density 40kg/m³
Coil: steel tube
Maximum coil test pressure: 25 bar
Electric heater: by order
Flange: diameter Ø278mm
Volume L 750 1000 1500
Code BLC-1-G BLC-1-H BLC-1-J
Coil S
input / outlet
1'' 1'' 1''
Coil
surface / m²
1,4 / 2,0 1,9 / 2,7 3
recirculation 1'' 1'' 1''
Cold water input 11/2''' 11/2''' 2 x 1 ½''
Hot water outlet 11/2''' 11/2''' 2 x 1 ½''
Tap - anode 3/4'' 3/4'' 2 x 1 ½''
For connection to a boiler of S1
and water 10/45°C KW/L/h
50
1218
62
1534
122
1997
A cold water input 300 330 310
L
N
hot water outlet
1630 1710 1965
B sensor 535 530 510
A coil input 300 330 310
C coil outlet 970 1080 1160
E recirculation 1405 1497 1477
F electric resistance 450 470 450
H total height 1990 2030 2310
E thermometer 1560 1670 1477
K
K
thermometer 2nd electric
resistance socket
1405 1497 1210
M anode 1435 1580 1640
D diameter Ø950 Ø1050 Ø1050
F boiler cleaning hole 450 470 450
Operation pressure / bar 10 10 10
Weight / kg 190 230 540
The electric resistance is an extra accessory and is being placed at the cleaning flange
Technical specification double coil floor standing boiler BLC-2
Material: steel sheet
Welding: automatic metal welding
Protection coating: high quality glass – enamel coating and protection anode
Maximum working pressure: 10 bar
Maximum working test pressure: 16 bar
Maximum operating temperature: 95°C
Insulation: polyurethane foam of 50mm thickness, density 40kg/m³
Coil: steel tube
Maximum coil test pressure: 25 bar
Electric heater: by order
Flange: diameter Ø170mm & Ø140
Volumen L 150 200 250 300 500 600
Code BLC-2-A BLC-2-B BLC-2-C BLC-2-D BLC-2-E BLC-2-F
Coil S1 & S2
input / outlet
1'' 1'' 1'' 1'' 1'' 1''
Coil S1 & S2
surface / m²
0,53/0,72 0,78/0,99 0,78/0,99 0,99/1,55 0,99/1,55 1,55/1,55
Recirculation 3/4''(1/2'') 3/4''(1/2'') 3/4''(1/2'') 3/4''(1/2'') 1'' 1''
Cold water input 1'' 1'' 1'' 1'' 1'' 1 ½''
Hot water outlet 1'' 1'' 1'' 1'' 1'' 1 ½''
Anode - flange Ø140 Ø140 Ø140 Ø140 Ø140 Ø140
For connection to a boiler with
S1 in boiler with 90°C and
water 10/45°C KW/L/h
16.3
254
19.7
338
19.7
340
22.5
394.2
22.5
394.2
42.5
977.5
For connection to a boiler with
S2 in boiler with 90°C and
water 10/45°C KW/L/h
18.2
450
22.5
552.8
22.5
542
31.25
542
31.25
767.5
35.7
1106.7
A cold water input 212 192 230 260 260 270
N hot water outlet 884 1128 1235 1265 1265 1590
C coil S1 outlet 602 682 720 750 750 960
M coil S2 outlet 884 1102 1170 1200 1200 1450
A coil S1 input 212 192 230 260 260 270
J coil S2 input 684 802 870 900 900 1062
K recirculation 798 977 1070 1100 1100 1256
H total height 1070 1340 1480 1480 1480 1810
E sensor 631 742 795 825 825 1011
B sensor 362 292 370 400 400 450
L thermostat 818 1027 1070 1100 1100 1256
O thermometer 874 1138 1235 1265 1265 1590
D diameter Ø560 Ø560 Ø600 Ø600 Ø750 Ø750
F boiler cleaning hole 400 400 400 400 400 400
Operation pressure / bar 10 10 10 10 10 10
Weight / kg 69 100 107 149 175 202
The electric resistance is an extra accessory and is being placed at the cleaning flange
Technical specification double coil
floor standing boiler BLC-2
Material: steel sheet
Welding: automatic metal welding
Protection coating: high quality glass – enamel coating and protection anode
Maximum working pressure: 10 bar
Maximum working test pressure: 16 bar
Maximum operating temperature: 95°C
Insulation: polyurethane foam of 100mm thickness, density 40kg/m³
Coil: steel tube
Maximum coil test pressure: 25 bar
Electric heater: by order
Flange: diameter Ø278mm
Volume L 750 1000 1500
Code BLC-2-G BLC-2-H BLC-2-J
Coil S1 & S2
input / outlet
1'' 1'' 1''
Coil S1 & S2
surface / m²
1,4 / 2,0 1,9 / 2,7 3
Recirculation 1'' 1'' 1''
Cold water input 11/2''' 11/2''' 2 x 1 ½''
Hot water outlet 11/2''' 11/2''' 2 x 1 ½''
Tap - anode 3/4'' 3/4'' 2 x 1 ½''
For connection to a boiler S1 and water
with 90°C and water 10/45°C KW/L/h
50
1218
62
1534
122
2997
For connection to a boiler S2 and water
with 90°C and water 10/45°C KW/L/h
68
1564
84
2604
1965
A cold water input 300 330 310
M
L
hot water outlet
thermostat
1630 1710 1965
B sensor 535 530 510
A coil S1 input 300 330 310
C coil S1 outlet 970 1080 1160
J recirculation / thermometer 1405 1497 1477
F electric resistance 450 470 450
N anode 1768 1798 2062
K thermometer 1405 1497 -
G coil S2 input 1160 1220 1330
L
K
coil S2 outlet 1560 1670 1780
H total height 1990 2030 2310
D diameter Ø 950 Ø1050 Ø1050
E sensor 1040 1150 1210
M thermostat - - 1965
Operation pressure / bar 10 10 10
Weight / kg 215 300 590
The electric resistance is an extra accessory and is being placed at the cleaning flange
COMBO-BOILER BAK-1 with container and one coil
500 L 750 L 1000 L 1350L 1600 L 2000 L
A 280 280 280 325 340 395
B 725 735 865 920 925 935
C 775 790 950 950 950 855
D1 Ø450 Ø650 Ø650 Ø800 Ø900 Ø1100
D2 Ø640 Ø810 Ø810 Ø1000 Ø1100 Ø1200
D3 Ø840 Ø1010 Ø1010 Ø1200 Ø1300 Ø1400
E 865 870 985 970 1200 1200
F 965 980 1150 1125 1200 1105
G 1005 1015 1195 1170 1250 1010
H 1690 1700 1920 2060 2110 2088
J 1155 1165 1350 1325 1425 1330
K 1310 1320 1530 1520 1710 1460
L 1365 1370 1590 1575 1710 1615
M 1365 1370 1590 1575 1710 1615
Typ Code
500 BAK-1-B
750 BAK-1-C
1000 BAK-1-D
1350 BAK-1-E
1600 BAK-1-F
2000 BAK-1-G
Volume / L 492 744 882 1285 1539 1831 Coil
volume / L
16,2 19,8 22 25 27,2 29,4
Coil surface / m²
2,2
2,7
3,0
3,4
3,7 4,0
Coil weight / kg
33,35
41,3
46
52,4 57,1 60,3
Container weight / kg
2mm 3mm 2mm 3mm 3mm 3mm 3,5mm 4mm 3,5mm 4mm 4mm
56,5 84,5 48,4 117,6 132,8 176,6 206 234,8 233,2 267 302,2
Total weight / kg
123,2
151,2
161
200,2
224,8
263,9
293,3
322,1
328,4
362,2
403,8
Maximum operation pressure
(coil) / bar
16
16
16
16
16
16
Maximum operation
temperature (coil) / °C
160
160
160
160
160
160
Insulation (polyurethane)
mm
100
100
100
100
100
100
Container volume
120 L 170 L 170 L 170 L 170 L 170 L
The electric resistance is an extra accessory and is being placed at the cleaning flange
Accumulator boiler BAC-1
without coils
500 L 750 L 1000 L 1350L 1600 L 2000 L
A 280 280 280 325 340 395
B - - - - - -
C 775 790 950 950 950 855
D1 Ø450 Ø650 Ø650 Ø800 Ø900 Ø1100
D2 Ø640 Ø810 Ø810 Ø1000 Ø1100 Ø1200
D3 Ø840 Ø1010 Ø1010 Ø1200 Ø1300 Ø1400
E - - - - - -
F 965 980 1150 1125 1200 1105
G 1005 1015 1195 1170 1250 1010
H 1690 1700 1920 2060 2110 2088
J 1155 1165 1350 1325 1425 1330
K 1310 1320 1530 1520 1710 1460
L 1310 1320 1530 1520 1710 1460
M 1365 1370 1590 1575 1710 1615
Typ Code
500 BAC-1-B
750 BAC-1-C
1000 BAC-1-D
1350 BAC-1-E
1600 BAC-1-F
2000 BAC-1-G
Volume
L 490 742 880 1283 1537 1829
Weight kg
2mm 3mm 2mm 3mm 3mm 3mm 3,5mm 4mm 3,5mm 4mm 4mm
56,5 84,5 78,4 117,6 132,8 176,6 206 234,8 233,2 267 302,2 Insulation
(polyurethane) mm
100
100
100
100
100
100
The electric resistance is an extra accessory and is being placed at the cleaning flange
Accumulator boiler BAC-2 With one coil
500 L 750 L 1000 L 1350L 1600 L 2000 L
A 280 280 280 325 340 395
B 725 735 865 920 925 395
C 775 790 950 950 950 855
D1 Ø450 Ø650 Ø650 Ø800 Ø900 Ø1100
D2 Ø640 Ø810 Ø810 Ø1000 Ø1100 Ø1200
D3 Ø840 Ø1010 Ø1010 Ø1200 Ø1300 Ø1400
E - - - - - -
F 965 980 1150 1125 1200 1105
G 1005 1015 1195 1170 1250 1010
H 1690 1700 1920 2060 2110 2088
J 1155 1165 1350 1325 1425 1330
K 1310 1320 1530 1520 1710 1460
L 1310 1320 1530 1520 1710 1460
M 1365 1370 1590 1575 1710 1615
Typ Code
500 BAC-2-B
750 BAC-2-C
1000 BAC-2-D
1350 BAC-2-E
1600 BAC-2-F
2000 BAC-2-G
Total volume / L 498 742 881 1284 1538 1830 Coil
(exchanger) volume / L
16,2 19,8 22 25 27,2 29,4
Coil (exchanger) surface / m²
2,2 2,7 3,0 3,4 3,7 4,0
Coil (exchanger) weight / kg
33,35 41,3 46 52,4 57,1 60,3
Accumulator weight / kg
2mm 3mm 2mm 3mm 3mm 3mm 3,5mm 4mm 3,5mm 4mm 4mm
56,5 84,5 78,4 117,6 132,8 176,6 206 234,8 233,2 267 302,2
Total weight / kg
89,85
117,85
119,7
158,9
178,8
229
258,4
287,2
290,3
324,1
362,5
Total coil (exchanger)
pressure / bar
16
16
16
16
16
16
Total coil (exchanger) temperature
/ °C
160
160
160
160
160
160
Insulation (polyutherane)
/ mm
100
100
100
100
100
100
The electric resistance is an extra accessory and is being placed at the cleaning flange
Accumulator boiler BAC-3 with two coil
500 L 750 L 1000 L 1350L 1600 L 2000 L
A 280 280 280 325 340 395
B 725 735 865 920 925 395
C 775 790 950 950 950 855
D1 Ø450 Ø650 Ø650 Ø800 Ø900 Ø1100
D2 Ø640 Ø810 Ø810 Ø1000 Ø1100 Ø1200
D3 Ø840 Ø1010 Ø1010 Ø1200 Ø1300 Ø1400
E 865 870 985 970 1200 1200
F 965 980 1150 1125 1200 1105
G 1005 1015 1195 1170 1250 1010
H 1690 1700 1920 2060 2110 2088
J 1155 1165 1350 1325 1425 1330
K 1310 1320 1530 1520 1710 1460
L 1360 1370 1570 1560 1605 1560
M 1365 1370 1590 1575 1710 1615
Typ Code
500 BAC-3-B
750 BAC-3-C
1000 BAC-3-D
1350 BAC-3-E
1600 BAC-3-F
2000 BAC-3-G
Total volume / L 498 744 882 1285 1539 1831 Coil
(exchanger) volume / L
16,2 19,8 22 25 27,2 29,4
Coil (exchanger) surface / m²
2,2 2,2
2,7 2,7
3,0 3,0
2,3 3,4
2,5 3,7
2,7 4,0
Coil (exchanger) weight /kg
33,35 33,35
41,3 41,3
46 46
34,9 52,4
38,1 57,1
41,3 60,3
Accumulator weight / kg
2mm 3mm 2mm 3mm 3mm 3mm 3,5mm 4mm 3,5mm 4mm 4mm
56,5 84,5 48,4 117,6 132,8 176,6 206 234,8 233,2 267 302,2
Total weight / kg
123,2
151,2
161
200,2
224,8
263,9
293,3
322,1
328,4
362,2
403,8
Total coil (exchanger)
pressure / bar
16
16
16
16
16
16
Total coil (exchanger) temperature
/ °C
160
160
160
160
160
160
Insulation (polyutherane)
mm
100
100
100
100
100
100
The electric resistance is an extra accessory and is being placed at the cleaning flange
Boiler reservoir MSG-1 & MSI-1 with two coil
Boiler reservoir MSG made of steel and enamel Glass
Boiler reservoir MSI made of stainless steel INOX
code volume code volume
MSG-1-A 200 L MSI-1-A 200 L
MSG-1-B 300 L MSI-1-B 300 L
The electric resistance is an extra accessory and is being placed at the cleaning flange
Lt A B DC LIHGFE S1QPONM Kglt/h-kWS2
80/60/45°C
5/4" 1/2" 5/4" 5/4" 5/4"1/2" 6/4" 1/2" m² m² S2S1
200
300 560
560
1685500
1290500
13451450-1"
9701060-1"
1187
888 860-3/4"
1132-3/4" 265565815977
265560675765 155-1"
155-1" 1450925300
1035705300
1,51
1,50,8
128980-40640-25
105980-40520-21
G- circulator
F- temperatur antenna
E- heat exchanger input
D- hotwater retrace
C- overall hight
B- diameter of the container
H- heat exchanger output
I- heat exchanger input
N- coldwater forerun
M- heat exchanger output
L- temperatur antenna
A - external diameter of the container
Q- temperatur antenna
P- space for electrical drag-typ
O- gasket 180 mm
A
B
N
D
FGH
I
M
L
C
Q
P
O
E
All electrical parts have a - qualitymark in accordance with the regulations: EN 60335-1 und EN 60335-2-21,CE UNI EN 10025, UNI EN 287-1, DIN 4753-1, DIN 4753-2, DIN 4753-3, DIN 4753-4, DIN 4753-6.
All measurements ar approximate statements. All technical changes reserved.
Waterreservoir : • MSG1 and MSG2 made of steel DCP (2,5 cm thickness),
with double enamel layer according to DIN 4753, baked at over 860ºC, for perfect corrosion protection
• MSI1 and MSI2 made of stainless steel INOX 316L (2 cm thickness)
Insulation :
• isoft foam insulation with a thickness of 6cm
at all types
nsulation made of ecologically friendly
Cathodic protection :
• for perfect inner protection
magnesium anode exchanged periodicaly
Coat of heat exchanger :
• MSG1 and MSG2 made of steel DCP (measurement 0,75m² x 2 / thickness 1,5 cm)
• MSI1 and MSI2 made of stainless steel INOX (measurement 0,75m² x 2 / thickness 1,5 cm)
External coat :
• at all types
made of stainless steel AISI 304 (EN 10082-2),
Electric parts :
• temperatur regulator and safety temperaturrestrictor
Electrical drag-typ is not encluded, but can be belated installed by an authorized installer.
Solarkit Magicsun MST1
Solarregulator MSR1
Charmeg MP-DT Integra 3P
A
B C
D
F
J
E
G
HK
L
A
B
C
F
E
D
J
H
G
L
K
safety valve exhaust pipeinside thread DIN 2000 / ISO 7, Rp ¾?
exhauster bottle with exhaust valve
lockable ballcock (retrace) with intigrated metal made backpressure valve / external thread ISO 228, G1?
lockable ballcock (forerun)with safety valveand intigrated backpressure valve / external thread ISO 228, G1?
recirculation pump WILO ST (25-6) solar model
manumeter - range 0-10 bar
wallmounting
equalisation vavlve SETTER Inline PF
thermometer - indicating range 0-160°C
hook up ADG - external thread ISO 228, G¾?
thermometer - indicating range 0-160°C
max. operationthemperature (t ):B
- forerun (exhaustion side): 160°C- retrace (pumpside): 95°C
max. operationpressure (p ):B
- to p 8 bar possibleB
- response pressure of built in saftly valve: 6 bar
material:- exhaustpipe: steel varnished- fittingbody: brass- inner parts: rustproof steel, brass, synthetic, borosilikate (viewing glas)- O-ring gaskets: EPDM- flat gaskets: solar texture and high temperature proof- insulation: EPP - valve after DIN 2999 / ISO 7 and ISO 228 measuring accuracy ± 10% (of result)
tecnical data
percolation textures:- water with common antirust and antifrost additions (indication index for texture
consistence = 2,3 mm²/s)
- heaterwater and coolingwater
tecnical data characteristics
temperature reading limits
main unit operation temperature
reading accuracy
current rating (resistive load)
probe number
probe cable length
protection degree (panel, unit)
firmware category
mains voltage
power consumption
0ºC bis 99ºC
-20ºC... 60ºC
± 2,5ºC
5A/250VAC/30VDC
3
MAX 30 m
Ip52, Ip20
Class A
230 VAC50 Hz
3 Watt
• controls the solar medium pump and the burner
• measures store and collector temperature from 0ºC to 99ºC
• it has double thunder protection and galvanic insulation
• can be precisely adjusted to the desired temperature difference
• it has adjustable temperature hysteresis
• can perform delayed operation for improved protection
• it has intelligant anti-freeze protection
All measurements ar approximate statements. All technical changes reserved.
Pressureexpantioncontainer 18 L SDA1
Flat roof boiler system MSFG and MSFI
• material is rustproof metal
• fluid contend 18 L
• for all complete systems
• 2 x collectors EKA2
• flat roof installationset G3
• boiler SFG3 220 L Glass or SFI3 200 L INOX
• boiler with two heat exchangers
• conection set for collectors and boiler
article no. description collectors
MSFI Boiler SFI3 200L INOX 2 x 2m²
article no. description collectors
MSFG Boiler SFG3 220L Glass 2 x 2m²
system MSFG:
system MSFI1:
The boiler SFG has identical technical data as solar- hot wate reservoir MSG.The boiler SFI has identical technical data as solar- hot wate reservoir MSI.
The boiler SFG and SFI will be deliverd with two heat exchangers.All measurements ar approximate statements. All technical changes reserved.
Declaration of warranty
COLLECTORS
Solar- hot water reservoirs and boilers
collector types:
EKA1,5 - EKA2 and KA2,5Ε
ten (10) year warranty on collectorsfunction and durability of materials
all types of solar- hot water reservoirs and boilers:
MSG1 / MSI1 / BAC1-3 / BLC1-2BAC1 / MSFG / MSFI
five (5) year warranty on function and durability of materials
warranty terms:
1.Warranty is valid from date of purchase, under the conditions of adviced instruction from the manufacturer and installation of authorized plumber. In case of missfunction of the product we oblige to insure a proper function, to replace defects if the problem results in a manufacturers fault.
2. A prolongation of the warranty is impossible after maintenance of repair.
3. As soon as the consumer notices a inproper function, he/she is obliged to interrupt the operation and to contact the plumber. The continued operation or the attemp to repair the product throuh not outherized persons, resultes in a expiration of the warranty, irrespective of the reason of the inproper operation.
4. In case of unpredictable Events, such as for excample weather-catastrophies, the warranty is invalid. The warranty expires in case of any influence on the product by unouthorized persons, respectively a lack of maintenance.
5. To valid warranty claims, it is necessary to:a. the signiture and the stamp of the plumber installing the productb. mailing of the inspectionrecord to the manifacturer (minimum 15 days after purchase), andc. receipt as proof of purchase.
6. The collector types *MK1,5/*MK2/MKA1,5/MKA2/MKA2,5/*und *EK 2 have a five (5) year warranty on collectorfunction and durability of materials. All collectors must be maintenanced once a year.
EK1,5
7. The collector types EKA1,5/ EKA2,5 have a ten (10) warranty on collectorfunction and durability of materials. All collectors must be maintenanced once a year.
EKA2/ year
8. All solar- hot water reservoirs and boilers have a five (5) warranty on function and durability of materials. On all solar- hot water reservoirs and boilers the magnesiumanode must be changed once a year.
year
9. All electrical parts as well as the circulationpump on MST1 and the solarregulator MSR1 have a one (1) year warranty.
10. The warranty of the pressureexpantioncontainer covers one (1) year.
11. For all complete solar systems the warranty of each paricular component valids.
ILIOTEHNOTHERMIKI C.Owarrantycertificate
name/surename (client):
adress (client):
phone (client):
dealer:
adress (dealer):
article number:
serial-number:
installations-date:
confirmation of installer:
The installation of the product was carried out by an authorized plumber and after adviced instruction from the manufacturer.
The proper function of the product was notified.
stamp of installer: the installer:
date . . . . . . . . . . . . . . . . . . . . signature:
1. maintenance number of invoice: . . . . . . . . . . .
date: . . . / . . . / . . . . .
signature:. . . . . . . . . . . . . . . . . . .
2. maintenance number of invoice: . . . . . . . . . . .
date: . . . / . . . / . . . . .
signature:. . . . . . . . . . . . . . . . . . .
3. maintenance number of invoice: . . . . . . . . . . .
date: . . . / . . . / . . . . .
signature:. . . . . . . . . . . . . . . . . . .
4. maintenance number of invoice: . . . . . . . . . . .
date: . . . / . . . / . . . . .
signature:. . . . . . . . . . . . . . . . . . .
5. maintenance number of invoice: . . . . . . . . . . .
date: . . . / . . . / . . . . .
signature:. . . . . . . . . . . . . . . . . . .
6. maintenance number of invoice: . . . . . . . . . . .
date: . . . / . . . / . . . . .
signature:. . . . . . . . . . . . . . . . . . .
7. maintenance number of invoice: . . . . . . . . . . .
date: . . . / . . . / . . . . .
signature:. . . . . . . . . . . . . . . . . . .
8. maintenance number of invoice: . . . . . . . . . . .
date: . . . / . . . / . . . . .
signature:. . . . . . . . . . . . . . . . . . .
9. maintenance number of invoice: . . . . . . . . . . .
date: . . . / . . . / . . . . .
signature:. . . . . . . . . . . . . . . . . . .
10. maintenance number of invoice: . . . . . . . . . . .
date: . . . / . . . / . . . . .
signature:. . . . . . . . . . . . . . . . . . .
WARRANTYCERTIFICATE AND INSPECTIONSRECORD
for consumer (frontside)from dealer in U.S.
for consumer (backside)from dealer in U.S.
inspectionrecord
ILIOTEHNOTHERMIKI C.O46200 PARAMYTHIA-THESPROTIAS-GREECE
INSPECTIONRECORD(cunsumer must sent this record to manifactur in order to
activatewarranty )
name/surename (consumer). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . adress (consumer) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .phone (consumer) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .dealer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .adress (dealer). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .phone (dealer) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .article number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .serial number. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
consumer confirmation:
plumber confirmation:
I hereby declare that the warrantyconditions are well-known, and the product is proper functional
after installation.
date . . . / . . . / . . . . . signature
I hereby declare that the product was installed appropriatly, and runs without problems after installation.
date . . / . . / . . . . signature / stamp* EK1,5 - EK 2 - MK1,5 and MK 2 no warranty on concealer glas.*