examples of applications for the tds-700
DESCRIPTION
Examples of Applications for the tDS-700. Dec.22, 2010. Virtual COM Basis. Command/Data/Modbus/Anything. Command/Data/Modbus/Anything. Transparent (with no protocol convert ). VCOM6/7. VCOM6/7. Transparent. RS-485. PLC. 10/100 M Ethernet. RS-485. tDS-725. PLC. Note: - PowerPoint PPT PresentationTRANSCRIPT
P.1
Examples of Applicationsfor the tDS-700
Examples of Applicationsfor the tDS-700
Dec.22, 2010
P.2
Virtual COM Basis
Meter
PLC10/100 M
Ethernet
RS-485
VCOM6/7 VCOM6/7
Transparent
tDS-725
Command/Data/Modbus/Anything Command/Data/Modbus/Anything
Note:
1. In the virtual COM application, the command or data is being copied between the PC and tDS-700 module with no protocol convert. This allows most of the serial protocols can be used with the virtual COM.
2. The max. COM port number in a PC is up to COM256.
3. The COM port is configured and mapped by using the VxComm Utility.
4. For Modbus/TCP to Modbus RTU/ASCII gateway, please refer tGW-700 models.
Transparent (with no protocol convert)
MeterPLC
RS-485
P.3
Virtual COM Application
RFID Reader
Meter
NS-208PSEEthernet Switch with PoE
MeterPLC
MeterPLC
10/100 M
Ethernet
RS-232
RS-485
RS-485
RS-485
VCOM5
VCOM6
VCOM7
VCOM8
…
VCOM5
VCOM6
VCOM7
VCOM8
tDS-712
tDS-715
tDS-725
VxComm
Driver
PLC
P.4
Direct TCP Socket Connection
Meter
PLC10/100 M
Ethernet
RS-485
tDS-725
Send raw data via
TCP client socket.
Raw data
Note:
1. The serial ports of the tDS-700 can be also accessed via TCP socket connections. TCP port 10001 = COM1, TCP port 10002 = COM2, TCP port 10003 = COM3.
2. Users have to configure the baud rate and data format via web configuration first, else the serial ports may send garbage data.
Transparent (with no protocol convert)
MeterPLC
RS-485
Port 10001 (COM1)
Port 10002 (COM2)
P.5
Serial Port Pair-connection Basis
PLC 2 uses 115200 bps
tDS-715 uses 115200 bps
tDS-715 uses 115200 bps
Serial Port Pair-connectionThrough the Ethernet
Port 1(RS-485)
PLC 1 uses 115200 bps
Port 1(RS-485)
Note: 1. PLC 1 and PLC 2 can communicate with each other via the RS-485 port that
has pair-connection link through the Ethernet.
Virtual RS-485 bus through the pair-connection.
P.6
Pair-connection with Different Baud Rate
PLC 2 uses 115200 bps
tDS-715 uses 115200 bps
tDS-725 uses 9600 bps
Serial Port Pair-connectionThrough the Ethernet
Port 1(RS-485)
PLC 1 uses 9600 bps
Port 1(RS-485)
Note: 1. PLC 1 and PLC 2 can use different baud rate and different data format at the same time
when using pair-connection. But please make sure that the tDS-700 has the same setting as local serial devices.
2. The pair-connection can be created by using same or different tDS-700 models.The pair-connection is working as port-to-port.
Virtual RS-485 bus through the pair-connection.
P.7
Virtual RS-485 Network (base on pair-connection)
PLC
Meter
RS-485
tDS-715
tDS-725
tDS-725Meter
tDS-725
tDS-735RS-485
Serial Port Pair-connectionThrough the Ethernet
Serial Port Pair-connectionThrough the Ethernet
Port 1
Port 2
Port 1
Port 2 (RS-485)
Port 1(RS-485)
Port 1
Port 1 (RS-485)
Port 2
Port 2 (RS-485)
Serial Port Pair-connectionThrough the Ethernet
PLC
Note: When connecting several tDS-700 (RS-485 master) in RS-485 network, you should remove the pull-high/low resister on the RS-485 port in most of the tDS-700 modules, and make sure there is only one master in the RS-485 network.
Port 3