Warnings:This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product and the hazards invo
Minimum 90C supply conductors.
All electrical connections must be performed by a certied electrician to applicable local and national electrical codes.
Contact Pinnacle prior to making any xture alterations.
Contact Pinnacle with any installation questions or eld issues.
PINNACLE ARCHITECTURAL LIGHTING 12655 E. 42nd Ave. Suite 50 Denver CO 80239 Phone: 303.322.5570 Fax: 303.322.5568 July 2009
Mounting Details For Aircraft Cable Interfa
Edge
Aircraft Cable to Structure (AC_ST)
Non-power side
Aircraft Cable to Grid Ceiling (AC_G_)
Non-power side
Aircraft Cable to Junction Box (AC_JB)
Non-power side
Power side
Power side
Power side
tilize with on-grid mounting with acoustical grid ceiling
tilize with sheet rock and off grid acoustical grid ceiling
tilize for inaccessible hard ceiling1/4-20 stud screw (by others)
Coupler
Aircraft cable
Conduit and ttings (by others)
4 -Octagonal
junction box
(by others)
Coupler
ircraft cable
5 Power
canopy
Strain relief
SJT cord
1/4-20 stud screw (by others)
Coupler
Aircraft cable
2 Non-power
canopy
onduit and
tings (by
thers)
Coupler
ircraft cable
5 Power
canopy
Strain relief
SJT cord
4-Octagonal
Junction box
onduit andtings (by
thers)
4-Octagonal
Junction box
Coupler
ircraft cable
5 Power
canopy
Strain relief
SJT cord
Coupler
Aircraft cable
2 Non-power
canopy
IDS clip
Tie off to structure
-
7/29/2019 EX Mounting
2/2
Warnings:This product must be installed in accordance with applicable installation and electrical codes by a professional familiar with the construction and operation of the product and the hazards invo
Minimum 90C supply conductors.
All electrical connections must be performed by a certied electrician to applicable local and national electrical codes.
Contact Pinnacle prior to making any xture alterations.
Contact Pinnacle with any installation questions or eld issues.
PINNACLE ARCHITECTURAL LIGHTING 12655 E. 42nd Ave. Suite 50 Denver CO 80239 Phone: 303.322.5570 Fax: 303.322.5568 July 2009
Pendant Pipe to Structure (PP_ST)
Pendant Pipe to Junction Box (PP_JB)
Non-power side
Non-power side
Power side
Power side
Mounting Details For Pendant Pipe Interfa
Edge
tilize with sheet rock and off grid acoustical grid ceiling
tilize for inaccessible hard ceiling
4-Octago-
nal junction
box (by
others)
Conduit and ttings (by others)
Set screw
Pendant pipe
5 Power
canopy
Set screw
Pendant pipe5 J-box
canopy
4-Octago-nal junction
box (by
others)
onduit and
tings (bythers)
Set screw
endant pipe
5 Power
canopySet screw
Pendant pipe5 J-box
canopy