Notes on Safety Navigating the functions
Do not exceed the maximum load of 10A / 2400W either with a singleappliance or with a group of appliance connected via a power strip.
Do not plug 2 or more ENERGY Watch Monitortogether.
For indoor use only.
Always ensure the plug of any appliance is inserted fully into the ENERGYWatch Monitor
Caution
Time / Watts / Cost (Fig.1)Top display:This number refers to how long the appliancehas been plugged into the power meter. The time does notautomatically reset when the appliance is unplugged. To re-start the timer press [ Reset button4].Middle display: This is an instantaneous reading of howmany watts the appliance is using.
Lower display:This shows you the cost of running an appli-ance over time. Cost can only be calculated after the cost isset (see previous page).
If left for 1 minute the power meter will revert to Time / Watts / Cost mode. Toswitch modes, press the [ Function button2]. Please note: kWh and costdata will not accumulate when consumption is below ~2.5 watts.
Display Modes
Kilowatt Hours (Fig.2)Middle display:This is a cumulative reading of kilowatt hours(kWh) that the appliance has used over the time shown in thetop display.
Lower display:The number of days that the appliance hasbeen plugged into the power meter.
Voltage / Frequency (Fig.3)Middle display:Voltage reading in Volts.
Lower display:Frequency reading in Hertz.
Amps / Power Factor (Fig.4)Middle display:Current reading in Amps.
Lower display:This is an instantaneousreading of the Power Factor.
Fig.1
Fig.3
Minimum Wattage (Fig.5)Middle display:This number refers to the lowest power con-sumption (in watts) of an appliance since the last reset (thelower display reads Lo).
Fig.5
Fig.2
Fig.4
Parts and Usage
Functionbutton2
Costbutton3
Resetbutton4
Downbutton6
LCD1
Up button5
Reading the displayTop display:This number refers to
how long the appliance has beenconnected to the meter. Data isstored when unplugged. To restartthe timer press [ Reset button4].Middle display:A reading of volts(V), amps (A), watts (W) or kilowatthours (kWh) depending on whatfunction is selected. The functionselected is determined by the sym-bol shown under the number.
Lower display:This displaychanges depending on what func-tion is chosen.
Battery back-upThere is a 3.6V rechargeable bat-tery installed inside the ENERGYWatch Monitor. It allows for the stor-age of data when the meter is notplugged in.
Using the ENERGY Watch MonitorPlug the meter into a power outlet and then plug an appliance or power boardinto the ENERGY Watch Monitor. The ENERGY Watch Monitors functions canbe selected by pressing the [ Function button2]. [ Cost button3] is a short-cut to the time / cost function.
To set the cost, hold down [ Cost button3]. Blinking numbers indicate thecost is ready to be changed. Use [ Function button2] to navigate betweenthe dollars and cents and use [ Up button5] and [ Down button6] to selectfigures. Press [ Cost button3] when finished.To clear the readings from a previous appliance, press [ Reset button4](with the point of a pen or pencil). This will also re-start the timer. [ Reset but-ton4] can also be used to clear the meter if an abnormal display appears onthe screen or if the meter is not responding.
Unplug the ENERGY Watch Monitor and it will turn off automatically.
-
8/10/2019 EW5001 Product Instructions
3/3
For more detailed instructions, FAQS, and product support please visit our websites.
www.wattsclever.com www.blog.wattsclever.com www.support.wattsclever.com
Maximum Wattage (Fig.6)Middle display:This number refers to thehighest power consumption (in watts) of
an appliance since the last reset (the low-er display reads Hi).
Time / Cost (Fig.7)Middle display:Blank.
Lower display:Cost / kWh (you can entreas either $00.00 or 00.00 cents).
Navigating the functions
Fig.6 Fig.7
Product SpecificationsModel EW-AUS5001
Dimensions 159 (L) x 72.7 (W) x 37.5 (H) mm(not include the plug)
Operating voltage 240V ACFrequency display 50Hz or 60Hz
Operating current max 10A
Wattage display (watts) 0W - 2400W
Current display (amps) 0.0A - 10.0A
Price display range 0.00 / KWH - 99.99 / KWH
Total KWH and cost display 0.000KWH -9999KWH, 0.00 - 9999
Room 1407, 14/F,
New Victory House,
93-103 Wing Lok Street,
Sheung Wan, Hong Kong
W www.wattsclever.com
T +852 2815 6333
Watts Clever(International) Limited
2011 Watts Clever(International) Limited
All Rights Reserved