6 MV catalogue Merlin Gerin Schneider Electric
Evolis: versatility
Where to use Evolis?
2004
63.ti
f
7MV catalogue Merlin GerinSchneider Electric
Evo
lis
Pre
sen
tati
on
2004
61.ti
f20
0460
.tif
Evolis circuit breakers are used to protect and control public or industrial mediumvoltage electrical distribution networks.Evolis is indoor switchgear that is particularly suited to the production andrenovation of HV/MV, MV/MV and MV/LV sub-stations.It is suitable for the protection of all types of application:cables, lines, motors, capacitors, transformers, bus sectioning of sources, etc.
2 versions adapt to your fixed or withdrawable installation:
Full versionwithdrawable with cradle
Modular versionbasic circuit breaker with kits deliveredin separate
8 MV catalogue Merlin Gerin Schneider Electric
1250 A
630 A
1250 A
1600 A
2500 A
2500 A
630 A
1250 A
1600 A
2500 A1250 A
1250 A
2500 A2500 A
P2 : 31,5 kA
P3 : 40 kA
P1 : 25 kA
Rated voltage
Rated breaking current
Rated current
7,2 kV
12 /17,5 kV
2500 A
1250 A
2500 A2500 A
P2 : 31,5 kA
P3 : 40 kA
P1 : 25 kA
Rated voltage
Rated breaking current
Rated current
7,2 kV
12/17,5 kV
1250 A1250 A
630 A2500 A2500 A1250 A
630 A
1250 A
2004
74.ti
f
The electrical characteristics are given in the circuit breaker designation
ccccc 3 rated voltages:v 7.2 kV index 7,v 12 kV index 17,v 17.5 kV index 17.
ccccc 3 breaking capacities:v 25 kA index P1,v 31.5 kA index P2,v 40 kA index P3.
ccccc 4 rated currents:630, 1250, 1600, 2500 A.
Full version
Modular version
Evolis: performance
What does Evolis offer you?
c The rating plates on the front of the circuitbreaker also show the breaking capacity:v yellow: 25 kAv blue: 31.5 kAv red: 40 kA.
9MV catalogue Merlin GerinSchneider Electric
Evo
lis
Pre
sen
tati
on
2001
10.e
ps20
0172
.eps
2002
05.e
ps
Evolis: heavy duty and innovative
How does Evolis eliminate faults? Electrical enduranceA magnetic field is applied along the axis of the vacuum interrupter contacts.This process maintains the arc in a diffuse mode even at high current values.It ensures optimum distribution of the energy over the contact surface thus avoidinglocalised hot spots.
c The advantages of this technique:
v a very compact vacuum interrupter,v low dissipation of arcing energy in the vacuum interrupter.
Evolis is in conformity with highest electrical endurance class(IEC 60 056: class E2).
Mechanical endurancec This magnetic field is generated by a patented external coil which surroundsthe contact zone. This solution provides many advantages:
v a simplified and therefore reliable vacuum interrupter,v heavy duty contacts which do not distort during repeated switching operations,v considerable reduction in control mechanism energy.
c For the first time, a low voltage device control mechanism has been integratedin a medium voltage circuit breaker. The Masterpact control mechanism used onEvolis provides the benefits of a system that has proven itself for over 10 yearson hundreds of thousands of installations.
Evolis is in conformity with most demanding mechanical endurance class(IEC 60 056: class M2)
An integrated protection chainThe Sepam 1000+ protection unit integrated with Evolis together with innovativecurrent sensors, provide you with a comprehensive metering, protection andenergy management chain.
c A high performance and economical solutionv Sepam 1000+, through its modular offer, proposes a cost effective solutionadapted to every requirement,v one single sensor reference covers the circuit breaker's full operating range.
c Easy to control and to installv all components in the protection chain are catalogued and delivered quickly,v current sensors, developed in the circuit breaker environment,are simply mounted on the busductsv the operation of the entire protection chain with the Evolis circuit breaker hasbeen extensively tested.
c The power of a multifunctional digital unitSepam 1000+ is not a simple protection relay, it is a multifunctional unit notablyproviding:
v circuit breaker diagnosis functions (number and time of switching operations,rearming time, cumulated switched A2 ),v direct circuit breaker control whatever release unit type,v remote equipment operation through the Modbus communication option.
10 MV catalogue Merlin Gerin Schneider Electric
2004
63.ti
f
Evolis:tailored to your requirements
What does Evolis offer you?
Circuit breakers that combinesimplicity of selection and richness of offer.
c 2 versions are proposed:v fullversion comprisingthe withdrawable circuit breakerand its cradlev modular version comprisingseparately delivered kits.
c "Universal" accessories can be addedto either version.E.g:coil, contact, motor, connection,inter-locking systems, etc
Full version:a fully assembled and tested unitc As standard, the circuit breaker is equiped with all the components requiredfor "ready to use" withdrawable installation in metal clad cubicles.This unit is easy to integrate in a cubicle environment, all it needs is mechanicallyfixing in place. An installation guide explains the required operations in detail.
c This version provides the guarantees of a highly reliable unit, whose componentsfunction in perfect harmony. Critical points such as inter-locking systems, dielectricwithstand and temperature rise have been checked thoroughly during design.It is a system that is fully integrated and tested by the manufacturer, in conformitywith IEC standards 60 298 and 60 056.
11MV catalogue Merlin GerinSchneider Electric
Evo
lis
Pre
sen
tati
on
2001
21
2001
19
2001
18
2001
17
2001
20
2004
90.ti
f
2001
22
Modular version:high added value accessoriesc The circuit beaker is proposed in its most simple configuration.In this case it can be combined with additional functions, to satisfy variousrequirements.
c This version offers maximum flexibility to adapt to constraints in existing cubiclesor to operating specifications:
v retrofit: fixed and withdrawable installation,v block-type cubicle or fenced sub-station: fixed or removable installation,v compartmented cubicle: fixed and withdrawable installation.
c The panel builder chooses the components he needs for a "customised" solutiontailor made to his know-how.
Build your own version…
12 MV catalogue Merlin Gerin Schneider Electric
2004
77.ti
f20
0464
.tif
Evolis: the commitment of a majormanufacturer
Conformity with standardsccccc Conformity with standards is a guarantee of suitability for the required function,the very basis of the contract between the supplier and the customer:vvvvv dependabilityvvvvv operator safety.It allows specifications to be fully satisfied whilst complying with local contraints.During its design phase, Evolis was subjected to a series of tests which confirmedexcellent performance levels, beyond the standards requirements.
ccccc Type testing:vvvvv dielectric tests,vvvvv temperature rise,vvvvv breaking capacity,vvvvv thermal withstand,vvvvv mechanical endurance,vvvvv electrical endurance.
ccccc Specific testing:vvvvv ageing,vvvvv transport and storage
N.B.:IEC 60 694: common specifications for high voltage switchgear and controlgear standardsIEC 60 056: high voltage alternating current circuit breakersIEC 60 298: A.C metal-enclosed switchgear between 1 kV and 52 kV.
Comment: for more information, consult the IEC organisation site: www.iec.ch.
Certificationc Certification of conformity provides guarantees that the product:
v has been subjected to type testing according to EN45001 standards proceduresin accredited laboratories by independent organisations,v is in conformity with recognized international standards.
ccccc Evolis is under process of certification by external EN 45011 accreditedorganisations, members of the STL (Short circuit Testing Liaison).
N.B.:EN45001: general requirements for the competence of testing and calibration laboratoriesEN45011: general requirements for bodies operating product certification systems.
What guarantees does Evolis provide?
13MV catalogue Merlin GerinSchneider Electric
Evo
lis
Pre
sen
tati
on
2004
65.ti
f20
0466
.tif
Guaranteed qualitySchneider Electric integrates a functional organisation in each of its units with themain mission of checking quality and overseeing compliance with standards.
The quality system, for the design and manufacture of Evolis circuit breakers,is certified to be in conformity with the requirements of ISO 9001 and ISO 9002quality assurance standards.
c ISO 9001: quality system for design/production and installationc ISO 9002: quality system for production and installationc IQNET: international certification network.
Systematic controlDuring manufacture, each circuit breaker is subjected to routine systematic testing,with the aim of checking both quality and conformity.
ccccc Control of vacuum interruptersEach vacuum interrupter, sealed and airtight, is checked for the quality of thevacuum obtained. This pressure measurement is based on the proven "magnetrondischarge" method.Using this sophisticated procedure, measurement is very precise and does notrequire access to the inside of the bulb, thus not affecting the airtight seal.
ccccc Control of the circuit breakerA rigorous set of tests and measurements is carried out on each circuit breaker.The results obtained are reported on and signed off by the quality controldepartment on the test certificate for each device, thereby guaranteeing producttraceability.
Respecting the environmentccccc Schneider Electric sets itself the goal ofv actively participating in environmental protection, from a circuit breaker's designright through to its end of life,v complying with the environmental requirements of both its customers and endusers of its products.
ccccc For Evolis circuit breakers
vvvvv development teams integrated the product's end-of-life right from the designstage. The product is easy to dismantle, all the materials used are recyclableand non-pollutingvvvvv plastic parts are marked to identify the material,vvvvv the circuit breakers are produced in factories which respect the environment.Our subsidiary at Aubenas, France has been awarded the ISO 14001 standardcertification (environmental management system).
Comment: for more information, consult the ISO organisation site: www.ISO.CH
14 MV catalogue Merlin Gerin Schneider Electric
0564
72.ti
f20
0479
.tif
Evolis circuit breaker
Masterpact circuit breaker
2004
90.ti
fEvolis: simplicity and rapidityPresentation
ChoiceEvolis circuit breakers offer a comprehensive and rational range:c 3 operating voltages (7.2 kV - 12 kV - 17.5 kV)c 3 breaking capacities (25 kA - 31.5 kA - 40 kA)c 4 current ratings (630 - 1250 - 1600 - 2500 A)c 1 common range of accessories and auxiliariesc 2 versions: complete and modular.
Ordering and deliveryc You can orderv the cradle before the circuit breaker,v a specific release unit, at the last moment, that you will easily be able to installyourself.
c Thanks to modular design and local customising, the delivery is faster.
InstallationEvolis is easy to incorporate in cubicles.c Optimisation of volumes: one single height and depth throughout the rangec Electrical auxiliaries are interchangeable throughout the rangec Adjustable device height in the cubiclec Variable phase to phase connection points.
Operation
Increased safetyEvolis has been designed and industrialised to provide maximum safety foroperators whilst guaranteeing the simplicity and rapidity of operations.c Protective metal shuttersc Safety interlocking systems to avoid operator errors when racking in or outc Racking in/out possible with the door closed.
Reduced maintenancec Contact wear diagnosis is possible through a measurement on the pole unitc Electrical auxiliairies are easily mounted on site (all you need is a screwdriver)c Common stock of replacement parts with the Masterpact circuit breakerc Diagnosis of the circuit breaker's functional chain using Sepam 1000+.
How Evolis makes your life easier?
15MV catalogue Merlin GerinSchneider Electric
Evo
lis
Pre
sen
tati
on
2004
67E
.tif
2004
69.ti
f20
0468
.tif
2004
75.ti
f
Tools to partner your know-how
Design guideThis document provides you with all the technical recommendations you requirefor your calculations when designing cubicles and incorporating equipment inconformity with IEC standard 60 298.
E.g.:v defining the switchgear,v dielectric strength,v busbar calculation,v temperature rise calculation,v definition of IP protection index.
Electronic catalogueThis "electronic" selection guide will rapidly become an everyday tool.Several access points are proposed to discover the offer. It automatically providesthe price of the device and an order form once you have selected your Evolisversion.
Installation guideThis document provides you with all the information and recommendations you needto incorporate the circuit breaker and its accessories in a cubicle.
E.g.:v dimensions and space requirements,v mechanical interface,v power circuit connection,v auxiliary connection,v layout diagrams.
AUTOCAD libraryFor easier and more reliable integration of Evolis in a cubicle environment,an extensive library of dimensional drawings and electrical layout diagramsis available in AUTOCAD format (format DXF/DWg/WMF).
Internet siteMissing a certificate? Lost a technical manual?Connect up to our web site where you can download all of our technicaldocumentation.
From pre-engineering to switchboardcomposition, a "toolkit" exists for panelbuilders to highlight their know-how andoptimise their work around Evolis.
Schneider Electric MV catalogue Merlin Gerin 17
Cir
cuit
bre
aker
Circuit breaker
Panorama 18Full version 20Performance tables 20Power circuit 22Sensors 23Racking in 24Support frame 25
Modular version 26Performance tables 26Connecting the power circuit 28Power circuit 29Sensors 30Racking in 31Support frame 32
Fitted accessories 33Opening circuit 33Remote control 35Indication 37Locking 38
Dimensions 39Full version 39Modular version 40
This chapter provides useful informationin selecting the performance levels of yourEvolis circuit breaker.It also describes all the functionsassociated to each versions.
18 MV catalogue Merlin Gerin Schneider Electric
Panorama20
0174
-E.e
ps
Ics = 100% Icu
220/440
525
690
100
100
85
Icw 85kA/1s
DV2
cat.B
IEC 947-2
UTEVDE
BS CEI UNEAS NEMA
EN 60947-2
50/60Hz
Ue
Icu
(V)
(kA)
00399
UC3UC2
UC1COM
SDE1
M2CUC4
/RESSDE2
closing release
Charging motor
and mechanism
Operationcounter
Bloc of 4o/c position contacts
Push buttondisabling
C.b. "open position"pad locking
Opening shunttrip release
"Ready to close"contact
C.b. "open positionkey locking
Low energy release
19MV catalogue Merlin GerinSchneider Electric
Cir
cuit
bre
aker
Panorama20
0175
-E.e
ps
C
C
Ics = 100% Icu
220/440
525
690
100
100
85
Icw 85kA/1s
DV2
cat.B
IEC 947-2
UTEVDE
BS CEI UNEAS NEMA
EN 60947-2
50/60Hz
Ue
Icu
(V)
(kA)
Racking base
LVsensors
1 contact for"locked in
confirmation"
Bushing
Finger
Cluster
Arm
Support frame
Racking truck
Circuit breakerBloc of 4racked in/outposition contacts
Shutter