evita 4 edition - ivermedi ltdivermedi.ge › attachments › pdf › evita_4.pdf · evita 4...

8
Evita 4 edition One of the best keeps getting better Emergency Care · Perioperative Care · Critical Care · Perinatal Care · Home Care Because you care

Upload: others

Post on 25-Jun-2020

14 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Evita 4 edition - IVERMEDI LTDivermedi.ge › attachments › pdf › evita_4.pdf · Evita 4 edition. Increased user productivity and enhanced patient safety are two key advantages

Evita 4 edition

One of the best keeps getting better

Emergency Care·Perioperative Care·Critical Care·Perinatal Care·Home Care Because you care

Page 2: Evita 4 edition - IVERMEDI LTDivermedi.ge › attachments › pdf › evita_4.pdf · Evita 4 edition. Increased user productivity and enhanced patient safety are two key advantages

Even when there’s little roomfor improvement …

enhanced

European screen image

Page 3: Evita 4 edition - IVERMEDI LTDivermedi.ge › attachments › pdf › evita_4.pdf · Evita 4 edition. Increased user productivity and enhanced patient safety are two key advantages

… we still find ways to make it better

How you benefit:• First-class ventilator performance• One ventilator cost-effectively

meets patient needs• Enhancements improve workflow

and minimize training• CareArea™ Solution connectivity

streamlines data capture so staffcan focus on patient care

The tradition of leadership continuesThe highly dependable Evita 4 has been recognized around the world as a leader in ventilation performance. Now, the Evita 4 editiontakes this popular ICU ventilator to yet anotherlevel, combined with design refinements that redefine user value.

A more user-friendly interfaceEvita 4 edition’s ergonomic display offers exceptional viewing. It also speeds routine tasksranging from calibration to maintenance by providing ideal access to the hose system, flow sensor and expiration valve.The full-color screen provides a comprehensivecustomized overview of the patient’s ventilationtherapy, complete with configurable trends, loops, measured values, curves and logbook.

To assure immediate recognition of the requiredsettings, the user-friendly display shows only theactive control elements. For added convenienceand efficiency, the robust touch screen combineshighly flexible operation with direct access to rotary knobs and keys.

Improved workflow efficiencyThe design of the patient part heating, expirationblock housing and flow sensor cover has beenoptimized to reduce condensation in the patientsystem and expiration valve. As a result, Evita 4edition extends flow sensor life and minimizes thetime clinicians spend checking and changing sensors. In addition, a drawer has been integratedso flow sensors, operating instructions or other frequently needed items are readily accessible atall times.

Page 4: Evita 4 edition - IVERMEDI LTDivermedi.ge › attachments › pdf › evita_4.pdf · Evita 4 edition. Increased user productivity and enhanced patient safety are two key advantages

advanced

It takes a lot to meet all your ventilation needs …

Page 5: Evita 4 edition - IVERMEDI LTDivermedi.ge › attachments › pdf › evita_4.pdf · Evita 4 edition. Increased user productivity and enhanced patient safety are two key advantages

… that’s why the Evita 4 edition is so complete.

One ventilator for every patient Evita 4 edition is designed to accommodate patients from neonate to adult. With a wide rangeof options, it allows you to handle ever-changingpatient populations and situations with a singlesolution. For example, the NeoFlow™ option offers flow measurement at the Y-piece for precisevolume and leak monitoring of neonates with accurate, responsive triggering based on patienteffort.

Excellent performance is standardThe Evita 4 edition allows respiratory loops to bedisplayed full screen, frozen and scrolled throughwith a cursor to show exact values. By pressingthe reference key, each loop can be used as a reference loop. In the case of external flowsources, sensor tolerances can automatically be increased to prevent nuisance alarms.And every Evita 4 edition is equipped with powerful weaning parameters. Rapid ShallowBreathing index, Negative Inspiratory Force indexand VTASB all contribute to improved consistencyof successful weanings.

Improve gas exchangeOur “Room to Breathe” concept encouragesspontaneous breathing. PCV+/BIPAP™ – the universal mode for ventilation and weaning in allpressure-controlled modes – gives a patient thefreedom to breathe spontaneously at any time.AutoFlow facilitates spontaneous breathing in allvolume-controlled modes. This optimizes weaningby reducing the need for sedation and invasiveness of ventilation.

Evita 4 edition also offers improved AutomaticTube Compensation (ATC™), an option that moreprecisely compensates for the tube-related workof breathing (WOB). This further improves weaning by adapting to patient efforts, and gives the feeling of virtual extubation.

NIV option helps recoveryMask ventilation can complement the weaningprocess by reducing re-intubation rates or eveneliminating the need for intubation in the firstplace. Because Evita 4 edition accommodatesboth conventional and non-invasive ventilation, it can help minimize the potential for infections, enhance recovery times and reduce length of stay compared to traditional therapies.

Due to an improved algorithm, non-invasive ventilation is now even more responsive to variable leakages. Quicker leakage “learning” and more responsive leakage compensation further enhance the patient-ventilator interaction.

Page 6: Evita 4 edition - IVERMEDI LTDivermedi.ge › attachments › pdf › evita_4.pdf · Evita 4 edition. Increased user productivity and enhanced patient safety are two key advantages

proven

Less training requiredThe continuity evident in the design of our user interfaces, even across different care areas,means current Dräger Medical customers will already be familiar with the operation of the Evita 4 edition. Increased user productivity and enhanced patient safety are two key advantages of Dräger Medical’s comprehensive and highly integrated CareArea™ Solutions.

Comprehensive supportDräger Medical provides a comprehensive support system that ensures you and your staff are able to optimize the use of your Evita 4edition. By focusing on your needs, we provide the tools to improve the quality of care for your patients.

A safe investmentThe Evita 4 edition is based on a fundamentalguiding principle of Dräger Medical’s CareArea™Solutions… the concept of continuous innovation.The device’s modular design ensures upgradeabil-ity and upward compatibility while the user inter-face and sensors guarantee a high degree of familiarity and consistency. Add options, such asATC®, PPS, NIV and NeoFlow, as needed to customize the system to specific departmentalneeds. Then, easily upgrade to new features asthey become available to ensure that the Evita 4edition remains a sound investment over time.

In addition, as part of Dräger Medical’s CareArea™Solution for Critical Care, the Evita 4 edition canbe integrated with leading-edge monitoring, infor-mation management, architectural systems andsmart accessories to help you steadily redefineprocess efficiency.

Operating costsAs the world of medicine becomes increasinglycost-conscious, the focus is shifting towards theoperating costs of medical equipment. High-quality and long-lasting components characterizethis proven ICU ventilator platform, resulting inlower operating costs.

More of what you look for …

Page 7: Evita 4 edition - IVERMEDI LTDivermedi.ge › attachments › pdf › evita_4.pdf · Evita 4 edition. Increased user productivity and enhanced patient safety are two key advantages

… to positively impact critical care

Page 8: Evita 4 edition - IVERMEDI LTDivermedi.ge › attachments › pdf › evita_4.pdf · Evita 4 edition. Increased user productivity and enhanced patient safety are two key advantages

Technical data Evita 4 editionPatient type Adults and childeren (bodyweight of at least 6.6 lbs. (3 kg))

With NeoFlow option: infants and and neonates (min. body weight of 1.1.lbs (0.5 kg))

Ventilation settingsVentilation mode • IPPV, IPPVAssist (CMV, CMVAssist)

• SIMV, SIMVASB (SIMV, SIMV/Psupp)• MMV, MMVASB (MMV, MMV/Psupp)• BIPAP1), BIPAP1)ASB, BIPAP1)Assist

(PCV+, PCV+/Psupp, PCV+Assist)• APRV • CPAP, CPAPASB (CPAP, CPAP/Psupp)• ILV• PPS (optional)*

Enhancements • AutoFlowTM – Automatic adaptation of inspiratory flow in volume controlled modes

• ATCTM – Automatic Tube Compensation (optional)• NIV – Mask Ventilation (optional)

Ventilation frequency (f) 0 to 100 /min, 0 to 150 /min (Neonatal)Inspiration time (Tinsp) 0.1 to 10 sTidal volume (VT) (BTPS*) • 0.1 to 2.0 L (Adult)

• 0.02 to 0.3 L (Pediatric)• 0.003 to 0.1 L (Neonatal)

Inspiratory flow • 6 to 120 L/min (Adult)• 6 to 30 L/min (Pediatric and Neonatal)

Inspiratory pressure 0 to 80 mbar (cmH2O)PEEP / intermittent PEEP 0 to 35 mbar (cmH2O)Pressureassist (PASB) (Psupp) 0 to 80 mbar (cmH2O)Rise time for inspiratory pressure 0 to 2 sO2 concentration 21 to 100 Vol.%Multi-sense Trigger Criteria Internal automatic pressure trigger, Flow, Volume

(Flow adjustable 0.3 to 15 L/min)Measured values displayedAirway pressure Peak pressure, plateau pressure, mean pressure, PEEP,

min. pressure (0 to 99 mbar/cmH2O) Minute volume (MV), (BTPS*) MV, MVspont, MVleak (0 to 99 L/min)Tidal volume (VT), (BTPS*) Inspired VT, expired VT, VTPS (0 to 3999 mL)Breathing frequency (f) ftotal, fspon, fmand. (0 to 300/bpm)O2 concentration (FiO2) Inspired O2 concentration (15 to 100 Vol.%)Lung mechanics • Resistance ((0.0 to 600 mbar/L/s) (cmH2O/L/s))

• Compliance ((0.0 to 300 mL/mbar) (mL/cmH2O))Breathing gas temperature 18°to 51°CWaveforms Airway pressure-time, flow-time, volume-time, ...Trends (8 anyone configurable) FiO2, MV, VT, f, PEEPi, R, C, etCO2, ...Loops Paw-V, V-Flow, Flow-Paw, ...Capnography (etCO2) (optional) • 0 to 100 mmHgCO2 production (VCO2) (optional) • 0 to 999 mL/min, STPD*Serial dead space Vds • 0 to 999 mL, BTPS*Dead space ventilation (Vds/VT) • 0 to 99 %Alarms / MonitoringAirway pressure High / LowExpired minute volume High / LowTidal volume HighApnea alarm time 5 to 60 sSpontaneous breath frequency HighInspired O2 concentration High / LowBreathing gas temperature HighetCO2 (optional) High / LowPerformance dataMax. flow for pressure supportand spontaneous breathing 180 L/min (adult), 60 L/min (pediatric)Valve response time T0...90 ≤ 5 msControl principle Time cycled, volume constant, pressure-controlledSafety relief valve 100 mbar (cmH2O)Leakage compensationHose system compensationOutlet for pneumatic nebulizerOperating dataMains power connection 100 to 240 V, 50/60 Hz, 10 to 30 V DC (optional)Power consumption Approx. 125 WGas supply operating pressure O2, air: 2.7 to 6 bar / 39 to 87 PSIPhysical SpecificationsDimensions ventilator (W x H x D) 530 x 290 x 450 mm (20.9 x 11.4 x 17.7 in.) (without trolley)Diagonal screen size 10.4" TFT LCD color touch screenWeight basic unit Approx. 27 kg (59.5 lbs.)Machine outputsDigital output Output and reception via an RS 232 C interfaceDigital output Output for independant lung ventilation (ILV)Digital output (optional) For output and reception via two RS 232 C interfacesAnalog output (optional) For analog output of two measured values

• •

90

50

818

/ 0

3.0

7-6

/ ls

-dw

/ P

rinte

d in

Ger

man

y /

Chl

orin

e-fr

ee -

envi

ronm

enta

lly c

ompa

tible

/ S

ubje

ct to

mod

ifica

tions

/ ©

20

07 D

räge

r M

edic

al A

G &

Co.

KG

Europe, Middle East, Africa, Latin America,Asia, Pacific:

Dräger Medical AG & Co. KGMoislinger Allee 53–5523542 LübeckGERMANYTel: +49-1805-3 72 34 37

+49-451-882-822Fax: +49-451-882-37 79E-mail: [email protected]

USA:

Draeger Medical, Inc.3135 Quarry Road Telford, PA 18969USATel: +1-215-721-5400Toll-free: +1-800-437-2437Fax: +1-215-723-5935E-mail: [email protected]

Canada:

Draeger Medical Canada Inc.120 East Beaver Creek Road Suite 104Richmond Hill Ontario L4B 4V1CANADATel: +1-905-763-3702Toll-free: +1-866-343-2273Fax: +1-905-763-1890E-mail: [email protected]

www.draeger.com

Manufacturer:Dräger Medical AG & Co. KG23542 Lübeck, Germany

The quality management system at Dräger Medical AG & Co. KG is certified according to ISO 13485, ISO 9001and Annex II of Directive 93/42/EEC(Medical devices).

* PPS is not available in the US 1) used under licenseATCTM, Trademarked by Dräger / AutoFlowTM, Trademarked by DrägerBTPS*, Body Temperature Pressure SaturatedMeasured values relating to the conditions of the patients lung, Body temperature 37°C, steam-saturated gas, ambient pressureSTPD* Standard Temperature, Pressure, Dry. Measured values based on normal physical conditions: 0°C, 1013 hPa, dry