A1
1850 Wilson Avenue, Toronto,Ontario, Canada, M9M 1A1
Ph: 416-741-7336 Fax: 416-741-9104
SECTION A
BALLASTS
ELECTRONIC BALLASTS
Electronic Ballasts A1T5 Straight Lamps A2-A7T8 Straight Lamps A8-A22T12 Straight Lamps A23-A24T12 High Output Lamps A25T5 Compact Fluorescent Lamps - CF Type A26-A32Long Twin Tube - 2G11 Type A33-A37Circline Lamps A382D Lamps A39GU24 Adapter Ballasts A40Dimmer Ballasts A41Ballast Disconnect A42-A43
Magnetic Ballasts A44-A55
Emergency Ballasts A56-A64
Appendix - Wiring Diagrams & Case Styles A65-A73
Appendix: Electronic Ballasts: Standard Lead Lengths & Standard Packaging A74-A79
Appendix and Suffix Guide A80
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
A2T5 Straight Lamps
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Ele
ctr
onic
Balla
sts
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
4W F4T5
1 EB-108-1-TP-FC 120 0.095 6.0 > 0.5 < 160 1.05 UL, cUL 28 V1 RS
1 EB-108-1-TP-FC-PH 120 0.095 6.0 > 0.5 < 160 1.05 UL, cUL 28 V1 PH
2 EB-108-1-TP-FC 120 0.12 8.0 > 0.5 < 160 1.0 UL, cUL 34 V1 RS
2 EB-108-1-TP-FC-PH 120 0.12 8.0 > 0.5 < 160 1.0 UL, cUL 34 V1 PH
6W F6T5
1 EB-108-1-TP-FC 120 0.12 8.0 > 0.5 < 160 1.0 UL, cUL 28 V1 RS
1 EB-108-1-TP-FC-PH 120 0.12 8.0 > 0.5 < 160 1.0 UL, cUL 28 V1 PH
2 EB-114-1-TP-FC ws 120 0.23 14.0 > 0.5 < 150 1.0 UL, cUL 34 V1 RS
2 EB-114-1-TP-FC-PH 120 0.23 14.0 > 0.5 < 150 1.0 UL, cUL 24 V1 PH
8W F8T5
2 EB-114-1-TP-FC ws 120 0.25 16.0 > 0.5 < 150 0.95 UL, cUL 34 V1 RS
2 EB-114-1-TP-FC-PH 120 0.25 16.0 > 0.5 < 150 0.95 UL, cUL 34 V1 PH
1 EB-108-1-TP-FC 120 0.13 8.5 > 0.5 < 130 1.0 UL, cUL 28 V1 RS
1 EB-108-1-TP-FC-PH 120 0.13 8.5 > 0.5 < 130 1.0 UL, cUL 28 V1 PH
1 EB-113-1-TP
120 0.17 10 > 0.5 < 150 1.1 UL, cUL 28
C6 RS
1 EB-113-1-TP-MC J1 RS
1 EB-113-1-TP-SL N2 RS
1 EB-113-1-TP-SL-MC P2 RS
1 EB-113-1-TP-SLL N1 RS
1 EB-113-1-TP-SLL-MC P1 RS
1 EB-113-1-TP-PN S1 RS
2 EB-208-1-TP
120 0.28 17 > 0.5 < 150 0.95 UL, cUL 30
C6 RS
2 EB-208-1-TP-MC J1 RS
2 EB-208-1-TP-SL N1 RS
2 EB-208-1-TP-SL-MC P1 RS
13W F13T5
1 EB-113-1-TP
120 0.25 15 > 0.5 < 150 0.95 UL, cUL 28
C6 RS
1 EB-113-1-TP-MC J1 RS
1 EB-113-1-TP-SL N2 RS
1 EB-113-1-TP-SL-MC P2 RS
1 EB-113-1-TP-SLL N1 RS
1 EB-113-1-TP-SLL-MC P1 RS
1 EB-113-1-TP-PN S1 RS
1 EB-114-1-TP-FC 120 0.22 14 > 0.5 < 150 0.95 UL, cUL 28 V1 RS
1 EB-114-1-TP-FC-PH 120 0.22 14 > 0.5 < 150 0.95 UL, cUL 28 V1 PH
2 EB-213-1-TP ws
120 0.43 28 > 0.5 < 150 0.95 UL, cUL 30
C6 RS
2 EB-213-1-TP-MC J1 RS
2 EB-213-1-TP-SL N1 RS
2 EB-213-1-TP-SL-MC P1 RS
14WF14T5
HE
1 EB-114-1-TP-FC ws 120 0.23 15 > 0.5 < 150 0.95 UL, cUL 28 V1 RS
1 EB-114-1-TP-FC-PH 120 0.23 15 > 0.5 < 150 0.95 UL, cUL 28 V1 PH
2 EB-221PS-1-TP 120 0.44 30 > 0.5 < 130 0.95 UL, cUL 38 L7 PS
2 EB-228-1-TP-PH-SL 120 0.44 30 > 0.5 < 130 0.95 UL, cUL 38 N1 PH
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
A3T5 Straight Lamps
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
14W F14T5
1 EPD-A14T5M 120~277 0.12-0.05 15 > 0.93 <10 1 UL, cUL 47 AA1 IS
1 EPS-A14T5M 120~277 0.13-0.05 15 > 0.93 <10 1 UL, cUL 31 AA1 IS
1 ESD-A21T5S 120~277 0.15-0.07 18 > 0.97 <10/20 0.99 UL, cUL 48 AA2 PS
1 ESD-B21T5 277-347 0.07-0.06 19 > 0.99 <15/20 1 UL, cUL 48 AA2 PS
1 ESS-A21T5 120~277 0.15-0.05 18 > 0.99 <10 0.97 UL, cUL 48 AA1 PS
1 FSD-A18PBM ws 120~277 0.14-0.08 19 > 0.98 <10/15 1.02 UL, cUL 5 AA23 PS
1 GSD-A18PBM ws 120~277 0.14-0.08 19 > 0.98 <10/15 1.01 UL, cUL 5 AA24 PS
1 TSD-UV21T5M 120~277 0.15~0.07 18 > 0.98 <10/40 0.99 UL, cUL 5 AA1 PS
2 EPD-A14T5M 120~277 0.25~0.10 30 > 0.99 <10 0.93 UL, cUL 5 AA1 IS
2 EPT-A14T5M 120~277 0.25~0.11 30 > 0.99 <10 1 UL, cUL 50 AA1 IS
2 ESD-A21T5S 120~277 0.28-0.13 34 > 0.99 < 10/15 0.93 UL, cUL 49 AA2 PS
2 ESD-B21T5 277-347 0.13-0.10 35 > 0.99 < 10/15 1 UL, cUL 49 AA2 PS
2 TSD-UV21T5M 120~277 0.28-0.13 33 > 0.99 < 10/15 0.93 UL, cUL 5 AA1 PS
3 EPQ-A14T5M 120~277 0.36~0.16 44 > 0.99 <10 1 UL, cUL 51 AA1 IS
3 EPT-A14T5M 120~277 0.36~0.16 36 > 0.99 <10 0.93 UL, cUL 13 AA1 IS
3 EPT-A21T5M 120~277 0.36~0.16 43 > 0.99 <10 0.93 UL, cUL 51 AA1 IS
4 EPQ-A14T5M 120~277 0.47~0.20 56 > 0.99 <10 0.93 UL, cUL 14 AA1 IS
4 EPQ-A21T5M 120~277 0.45~0.20 54 > 0.99 <10 0.88 UL, cUL 14 AA1 IS
4 EPQ-A35T5M 120~277 0.45~0.20 55 > 0.99 <10 0.74 UL, cUL 14 AA1 IS
21W F21T5
1 ESD-A21T5S 120~277 0.20~0.09 24 > 0.97 < 10/20 0.99 UL, cUL 48 AA2 PS
1 ESD-B21T5 277-347 0.09-0.08 26 > 0.97 < 10/20 0.99 UL, cUL 48 AA2 PS
1 ESS-A21T5 120~277 0.20~0.09 25 > 0.99 < 10/20 0.97 UL, cUL 48 AA2 PS
1 FSD-A18PBM 120~277 0.22~0.10 28 > 0.98 <10 0.93 UL, cUL 5 AA23 PS
1 GSD-A18PBM 120~277 0.22~0.1 28 > 0.98 <10 0.93 UL, cUL 5 A24 PS
1 TSD-UV21T5M 120~277 0.20~0.09 25 > 0.98 < 10/20 0.97 UL, cUL 5 AA1 PS
2 ESD-A21T5S 120~277 0.40-0.17 48 > 0.99 <10 0.91 UL, cUL 49 AA2 PS
2 ESD-B21T5 277~347 0.17-0.15 48 > 0.99 < 10/15 0.99 UL, cUL 49 AA2 PS
2 FSD-A32PBM ws 120~277 0.54~0.24 64 > 0.99 < 10/15 1.24 UL, cUL 33 AA23 PS
2 TSD-UV21T5M 120~277 0.40-0.17 48 > 0.99 <10 0.93 UL, cUL 5 AA1 PS
3 EPT-A21T5M 120~277 0.52~0.22 62 > 0.99 <10 0.90 UL, cUL 13 AA1 IS
4 EPQ-A21T5M 120~277 0.70~0.30 84 > 0.99 <10 0.89 UL, cUL 14 AA1 IS
4 EPQ-A35T5M 120~277 0.60~0.27 73 > 0.99 <10 0.70 UL, cUL 14 AA1 IS
4 EPQ-335T5S 347 0.23 79 > 0.97 <10 0.97 UL, cUL 14 AA3 IS
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A4
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
T5 Straight Lamps
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
21W F21T5 HE
1 EB-114-1-TP-FC ws 120 0.30 21 > 0.5 < 150 0.80 UL, cUL 28 V1 RS
1 EB-114-1-TP-FC-PH 120 0.30 21 > 0.5 < 150 0.80 UL, cUL 28 V1 PH
1 EB-135HE-1-TP ws 120 0.34 22 > 0.5 < 150 1.0 UL, cUL 28 N1 RS
1 EB-135HE-1-TP-PH 120 0.34 22 > 0.5 < 150 1.0 UL, cUL 28 N1 PH
1 EB-128-1-TP-FC 120 0.34 24 > 0.5 < 150 1.0 UL, cUL 28 V1 RS
2 EB-221PS-1-TP 120 0.60 41 > 0.5 < 130 0.90 UL, cUL 38 L7 PS
2 EB-228-1-TP-PH 120 0.60 41 > 0.5 < 130 0.90 UL, cUL 38 L7 PH
2 EB-228-1-TP-PH-SL 120 0.60 41 > 0.5 < 130 0.90 UL, cUL 38 N1 PH
21WF21T5
HE
1 EB-228HE-UV-TP-PS 120~277 0.21~0.10 26 > 0.95 < 15 1.03 Pending 37 U4 PS
2 EB-228HE-UV-TP-PS 120~277 .40~0.17 48 > 0.98 < 10 1.02 Pending 36 U4 PS
2 EB-235HE-UV-TP-PS 120~277 0.40~0.17 48 > 0.98 < 10 1.02 Pending 36 U4 PS
2 EB-228-1-TP-PH-SL 120 0.70 50 0.5 < 130 0.80 UL, cUL 38 N1 PH
24WF24T5
HO
1 EB-139HO-1-TP 120 0.41 28 > 0.5 < 150 1.0 UL, cUL 28 N1 RS
1 EB-224HO-UV-TP-PS 120~277 0.23~0.11 28 > 0.95 < 12 0.96 UL, cUL 37 U4 PS
1 EB-239HO-UV-TP-PSws 120~277 0.24~0.12 29 > 0.92 < 12 1.10 UL, cUL 37 U4 PS
2 EB-224HO-UV-TP-PS 120~277 0.42~0.19 50 > 0.98 < 12 0.90 UL, cUL 36 U4 PS
2 EB-239HO-UV-TP-PSws 120~277 0.44~0.20 52 > 0.97 < 12 1.00 UL, cUL 36 U4 PS
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Ele
ctr
onic
Balla
sts
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A5
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
T5 Straight Lamps
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
28W F28T5
1 EB-135HE-1-TP 120 0.41 28 > 0.5 < 130 0.92 UL, cUL 28 N1 RS
1 EB-135HE-1-TP-PH 120 0.41 28 > 0.5 < 130 0.92 UL, cUL 28 N1 PH
1 EB-128-1-TP-FC 120 0.42 30 > 0.5 < 130 0.95 UL, cUL 28 V1 RS
1 EB-228HE-UV-TP-PS 120~277 0.28~0.12 33 > 0.98 < 10 1.04 PENDING 37 U4 PS
1 EPD-A28T5M 120~277 0.28~0.12 33 > 0.99 < 10 1 UL, cUL 47 AA1 IS
1 EPD-A35T5M 120~277 0.26~0.11 31 > 0.98 < 10 1.04 UL, cUL 47 AA1 IS
1 EPS-A28T5M 120~277 0.25~0.11 30 > 0.99 < 10 0.93 UL, cUL 31 AA1 IS
1 ESD-A35T5M 120~277 0.29~0.13 36 > 0.99 < 10/20 0.98 UL, cUL 48 AA2 PS
1 ESD-A35T5S 120~277 0.29~0.13 36 > 0.99 < 10/20 1.07 UL, cUL 48 AA2 PS
1 ESD-B35T5 ws 277~347 0.12~0.11 34 > 0.99 < 30 1 UL, cUL 48 AA2 PS
1 ESD-B35T5S 277~347 0.12~0.11 34 > 0.99 < 10 1 UL, cUL 48 AA2 PS
1 FSD-A18PBM ws 120~277 0.29~0.14 36 > 0.98 < 10 1.01 UL, cUL 5 AA23 PS
1 GSD-A18PBM ws 120~277 0.29~0.14 36 > 0.98 < 10 1.01 UL, cUL 5 AA24 PS
1 TSD-B35T5M 277~347 0.12~0.11 34 > 0.99 < 12 0.99 UL, cUL 5 AA1 PS
1 TSD-UV35T5M 120~277 0.29~0.13 36 > 0.98 < 10/20 1.07 UL, cUL 5 AA1 PS
2 EB-221PS-1-TP 120 0.70 50 > 0.5 < 130 0.80 UL, cUL 38 L7 PS
2 EB-228-1-TP-PH 120 0.70 50 > 0.5 < 130 0.80 UL, cUL 38 N1 PH
2 EB-228-1-TP-PH-SL 120 0.70 50 > 0.5 < 130 0.80 UL, cUL 38 N1 PH
2 EB-228HE-UV-TP-PS 120~277 0.53~0.23 64 > 0.98 < 10 1.03 PENDING 36 U4 PS
2 EPD-A28T5M 120~277 0.46~0.20 56 > 0.99 < 10 0.93 UL, cUL 12 AA1 IS
2 EPD-A35T5M 120~277 0.47~0.20 56 > 0.98 < 10 0.95 UL, cUL 12 AA1 IS
2 EPT-A28T5M 120~277 0.51~0.22 61 > 0.99 < 10 0.99 UL, cUL 50 AA1 IS
2 EPT-A35T5M 120~277 0.51~0.22 61 > 0.99 < 10 0.98 UL, cUL 50 AA1 IS
2 ESD-A35T5M 120~277 0.56~0.25 56 > 0.99 < 10 0.95 UL, cUL 49 AA2 PS
2 ESD-A35T5S 120~277 0.56~0.25 69 > 0.99 < 10 0.96 UL, cUL 49 AA2 PS
2 ESD-B35T5 ws 277~347 0.24~0.19 66 > 0.99 < 10 0.96 UL, cUL 49 AA2 PS
2 ESD-B35T5S 277~347 0.24~0.19 66 > 0.99 < 10 0.96 UL, cUL 49 AA2 PS
2 TSD-B35T5M 277~347 0.28~0.25 65 > 0.99 < 12 0.94 UL, cUL 5 AA1 PS
2 TSD-UV35T5M 120~277 0.56~0.25 68 > 0.99 < 10 0.95 UL, cUL 5 AA1 PS
3 EPQ-A28T5M 120~277 0.67~0.29 80 > 0.99 < 10 1 UL, cUL 51 AA1 IS
3 EPT-A28T5M 120~277 0.65~0.29 78 > 0.99 < 10 0.9 UL, cUL 13 AA1 IS
3 EPT-A35T5M 120~277 0.65~0.29 78 > 0.98 < 10 0.9 UL, cUL 13 AA1 IS
4 EPQ-A28T5M 120~277 0.87~0.38 104 > 0.99 < 10 0.93 UL, cUL 14 AA1 IS
4 EPQ-A35T5M 120~277 0.80~0.35 97 > 0.99 < 10 0.74 UL, cUL 14 AA1 IS
4 EPQ-335T5S 347 0.29 101 > 0.98 < 10 0.81 UL, cUL 14 AA3 IS
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A6T5 Straight Lamps
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Ele
ctr
onic
Balla
sts
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
35W F35T5
1 EPD-A35T5M 120~277 0.31~0.13 37 > 0.98 < 10 0.95 UL. cUL 47 AA1 IS
1 ESD-A35T5S 120~277 0.35~0.16 44 > 0.98 < 10/15 1.02 UL. cUL 48 AA2 PS
1 ESD-B35T5ws 277~347 0.15~0.12 44 > 0.98 < 10/15 0.99 UL. cUL 48 AA2 PS
1 ESD-B35T5S 277~347 0.15~0.12 41 > 0.99 < 10/15 0.99 UL. cUL 48 AA2 PS
1 TSD-B35T5M 277~347 0.15~0.13 41 > 0.99 < 35 0.96 UL. cUL 5 AA1 PS
1 TSD-UV35T5M 120~277 0.35~0.16 36 > 0.98 < 10/20 1.03 UL. cUL 5 AA1 PS
2 EPD-A35T5M 120~277 0.55~0.24 67 > 0.99 < 10/15 0.88 UL. cUL 12 AA1 IS
2 EPT-A35T5M 120~277 0.85~0.37 102 > 0.98 < 10 0.98 UL. cUL 50 AA1 IS
2 ESD-A35T5S 120~277 0.69~0.3 84 > 0.99 < 10 0.95 UL. cUL 49 AA2 PS
2 ESD-B35T5ws 277~347 0.28~0.23 78 > 0.97 < 10 0.90 UL. cUL 49 AA2 PS
2 ESD-B35T5S 277~347 0.28~0.23 78 > 0.99 < 10 0.90 UL. cUL 49 AA2 PS
2 TSD-B35T5M 277~347 0.28~0.23 78 > 0.99 < 10 0.99 UL. cUL 5 AA1 PS
2 TSD-UV35T5M 120~277 0.69~0.3 85 > 0.99 < 10 0.92 UL. cUL 5 AA1 PS
3 EPT-A35T5M 120~277 0.85~0.37 102 > 0.98 < 10 0.90 UL. cUL 13 AA1 IS
4 EPQ-335T5S 347 0.39 134 > 0.98 < 10 0.80 UL. cUL 14 AA3 IS
4 EPQ-A35T5M 120~277 0.99~0.43 118 > 0.99 < 10 0.77 UL. cUL 14 AA1 IS
35W F35T5HE
1 EB-135HE-1-TPws 120 0.48 34 > 0.50 < 130 0.88 UL. cUL 28 N1 RS
1 EB-135HE-1-TP-PH 120 0.48 34 > 0.50 < 130 0.88 UL. cUL 28 N1 PH
1 EB-235HE-UV-TP-PS 120~277 0.34~0.15 41 > 0.98 < 10 1.00 PENDING 37 U4 PS
2 EB-235HE-UV-TP-PS 120~277 0.67~0.28 80 > 0.98 < 10 1.00 PENDING 36 U4 PS
39W F39T5
1 ESS-A54T5ws 120~277 0.35~0.14 43 > 0.99 < 10/15 0.82 UL. cUL 48 AA2 PS
2 EPD-A54T5M 120~277 0.69~0.32 87 > 0.98 < 10/15 1.02 UL. cUL 47 AA1 IS
2 ESD-A54T5ws 120~277 0.76~0.33 92 > 0.98 < 10/15 0.99 UL. cUL 49 AA4 PS
2 TSD-UV54T5M 120~277 0.7~0.32 85 > 0.99 < 10/15 1 UL. cUL 5 AA1 PS
2 ESD-B54T5ws 277~347 0.3~0.25 84 > 0.99 < 10 0.93 UL. cUL 49 AA4 PS
4 ESPQ-A54T5S 120~277 1.42~0.64 174 > 0.98 < 10/15 1 UL. cUL 42 AA5 PS
39W F39T5 HO
1 EB-139HO-1-TP 120 0.49 35 > 0.50 < 130 0.90 UL. cUL 28 N1 RS
1 EB-224HO-UV-TP-PS 120~277 0.33~0.15 39 > 0.97 < 12 0.90 UL. cUL 37 U4 PS
1 EB-239HO-UV-TP-PS 120~277 0.40~0.18 48 > 0.96 < 12 1.15 UL. cUL 37 U4 PS
2 EB-239HO-UV-TP-PS 120~277 0.78~0.34 94 > 0.98 < 10 1.12 UL. cUL 36 U4 PS
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A7T5 Straight Lamps
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Ele
ctro
nic
Balla
sts
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
54WF54T5
HO
1 EB-154HO-1-TP 120 0.74 51 > 0.5 < 130 0.95 UL. cUL 28 N1 RS
1 EB-155-1-TP-SC* 120 0.82 59 > 0.5 < 130 1.00 UL. cUL 28 L8 RS
1 EB-254HO-UV-TP-PS 120 ~ 277 0.51~0.23 61 > 0.98 < 10 1.02 UL. cUL 37 U4 PS
1 EB-454HO-UV-TP-PS 120 ~ 277 0.52~0.25 63 > 0.91 < 20 1.02 PENDING 48 L10 PS
1 EPD-A54T5M 120 ~ 277 0.57~0.23 69 > 0.99 < 10 0.87 UL. cUL 47 AA1 IS
1 ESS-A54T5 120 ~ 277 0.45~0.2 55 > 0.98 < 10 0.85 UL. cUL 48 AA2 PS
1 TSD-UV54T5M 120 ~ 277 0.51~0.24 63 > 0.98 < 10/18 1.03 UL. cUL 5 AA1 PS
1 ESD-A54T5ws 120 ~ 277 0.5~0.23 61 > 0.98 < 10/15 0.99 UL. cUL 48 AA4 PS
1 ESD-B54T5 277 ~ 347 0.22~0.18 61 > 0.99 < 15 0.97 UL. cUL 48 AA4 PS
2 EB-254HO-UV-TP-PS 120 ~ 277 0.98~0.42 117 > 0.98 < 10 1.00 UL. cUL 36 U4 PS
2 EB-454HO-UV-TP-PS 120 ~ 277 0.98~0.44 116 > 0.97 < 15 1.00 PENDING 47 L10 PS
2 EPD-A54T5M 120 ~ 277 0.9~0.43 108 > 0.99 < 10 0.87 UL. cUL 12 AA1 IS
2 ESD-A54T5ws 120 ~ 277 0.97~0.43 117 > 0.98 < 10 0.99 UL. cUL 49 AA4 PS
2 TSD-UV54T5M 120 ~ 277 0.96~0.43 115 > 0.99 < 10/12 0.93 UL. cUL 5 AA1 PS
2 ESD-B54T5 277 ~ 347 0.43~0.34 119 > 0.99 < 10 0.93 UL. cUL 49 AA4 PS
3 EB-454HO-UV-TP-PS 120 ~ 277 1.42~0.62 170 > 0.98 < 15 1.02 PENDING 48 L10 PS
3 ESPQ-A54T5S 120 ~ 277 1.47~0.67 180 > 0.98 < 10/15 1.00 UL. cUL 51 AA5 PS
4 EB-454HO-UV-TP-PS 120 ~ 277 1.85~0.79 220 > 0.99 < 10 1.00 PENDING 47 L10 PS
4 ESPQ-A54T5S 120 ~ 277 1.92~0.86 231 > 0.98 < 10 0.98 UL. cUL 42 AA5 PS
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A8T8 Straight Lamps
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
14W F13T8
1 EB-126-1-TPws
120 0.27 16 > 0.50 < 160 1.1 UL,CSA 28
S1 RS
1 EB-126-1-TP-LC L2 RS
1 EB-126-1-TP-LC-TB U2 RS
1 EB-126-1-TP-SL N1 RS
1 EB-126-1-TP-SL-TB U3 RS
1 EB-126-1-TP-SC * L8 RS
14W F14T8
1 EB-120-1-TP 120 0.24 15 > 0.50 < 150 1.1 UL, cUL 28 X1 RS
1 EB-120-1-TP-EMI 120 0.24 15 > 0.50 < 150 1.1 UL, cUL 28 L7 RS
2 EB-220-1-TP # 120 0.42 27 > 0.50 < 150 0.85 UL, cUL 30 L7 RS
15W F15T8
1 EB-126-1-TPws
120 0.27 17 > 0.50 < 150 1.0 UL,CSA 28
S1 RS
1 EB-126-1-TP-LC L2 RS
1 EB-126-1-TP-LC-TB U2 RS
1 EB-126-1-TP-SL N1 RS
1 EB-126-1-TP-SL-TB U3 RS
1 EB-126-1-TP-SC * L8 RS
1 EB-132-2-TP-PIC-SL 277 0.07 19 0.98 < 10 1.05 UL, cUL 28 N3 RS
1 EB-232RIS-1-TP-SL 120 0.32 20 0.52 < 150 0.90 UL, cUL 31 N3 IS
1 EB-120-1-TP 120 0.26 17 > 0.50 < 150 1.1 UL, cUL 28 X1 RS
1 EB-120-1-TP-EMI 120 0.26 17 > 0.50 < 150 1.1 UL, cUL 28 L7 RS
1 EB-132-1-TP* 120 0.27 17 > 0.50 < 150 1.1 UL, cUL 28 L7 RS
2 EB-220-1-TP # 120 0.48 32 > 0.50 < 150 1.0 UL, cUL 30 L7 RS
2 EB-2C72-1-TP 120 0.45 29 > 0.50 < 160 0.80 UL, CSA 30 L1 RS
2 EB-232-1-TP-SL 120 0.45 29 > 0.50 < 160 0.80 UL, cUL 30 N1 RS
2 EB-232RIS-1-TP-SL 120 0.43 28 > 0.50 < 160 0.80 UL, cUL 30 N3 IS
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Ele
ctr
onic
Balla
sts
* replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
# add “EMI” for model with EMI filter, comply with FCC Class B.
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A9T8 Straight Lamps
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
** replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
* cap off one BLUE wire for one lamp application.
# add “EMI” for model with EMI filter, comply with FCC Class B.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Ele
ctro
nic
Balla
sts
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
17W F17T8
1 EB-126-1-TPws
120 0.31 20 > 0.50 < 150 1.0 UL, CSA 28
S1 RS
1 EB-126-1-TP-LC L2 RS
1 EB-126-1-TP-LC-TB U2 RS
1 EB-126-1-TP-SL N1 RS
1 EB-126-1-TP-SL-TB U3 RS
1 EB-126-1-TP-SC ** L8 RS
1 EB-132-1-TP 120 0.31 20 > 0.50 < 150 1.15 UL, cUL 28 L7 RS
1 EB-120-1-TP 120 0.29 19 > 0.50 < 150 1.15 UL, cUL 28 X1 RS
1 EB-120-1-TP-EMI 120 0.29 19 > 0.50 < 150 1.15 UL, cUL 28 L7 RS
1 EB-132-1-TP-PIC 120 0.18 22 > 0.99 < 12 1.0 UL, cUL 31 L3 IS
1 EB-232RIS-1-TP 120 0.37 21 > 0.50 < 160 0.97 UL, cUL 31 L5 IS
1 EB-132LBF-1-TP-PIC 120 0.15 17 > 0.98 < 10 0.90 UL, cUL 31 L5 IS
1 EB-132LBF-1-TP-PIC-SL 120 0.15 17 > 0.98 < 10 0.90 UL, cUL 31 L6 IS
1 EB-132LBF-2-TP-PIC 277 0.07 17 > 0.98 < 10 0.90 UL, cUL 31 L5 IS
1 EB-132LBF-2-TP-PIC-SL 277 0.07 17 > 0.98 < 10 0.90 UL, cUL 31 L6 IS
1 EB-132-2-TP-PIC-SL 277 0.08 21 > 0.98 < 10 0.95 UL, cUL 31 N3 RS
1 EB-132-UV-TP-SLws 120~277 0.18~0.08 21 > 0.96 < 12 1.0 UL, cUL 6 RS
1 EB-132-UV-TP-PIC 120~277 0.18~0.08 21 > 0.96 < 10 1.0 UL, cUL 31 IS
1 EB-132LBF-UV-TP-PIC 120~277 0.15~0.07 18 > 0.98 < 10 0.88 UL, cUL 31 IS
1 EB-132LBF-UV-TP-PIC-SL 120~277 0.15~0.07 18 > 0.98 < 10 0.88 UL, cUL 31 IS
1 EB-132EBF-UV-TP-PIC 120~277 0.14~0.06 17 > 0.97 < 12 0.77 UL, cUL 31 IS
1 EB-232RIS-1-TP-SL 120 0.39 25 0.54 < 150 1.10 UL, cUL 31 L5 IS
1 EB-132EBF-1-TP-PIC 120 0.14 17 > 0.97 < 12 0.77 UL, cUL 31 L5 IS
1 EB-132EBF-2-TP-PIC 277 0.06 17 > 0.97 < 12 0.77 UL, cUL 31 L5 IS
1 EB-132HBF-1-TP-PIC 120 0.19 23 > 0.97 < 12 1.18 UL, cUL 31 L5 IS
1 EB-132HBF-2-TP-PIC 277 0.09 23 > 0.97 < 12 1.18 UL, cUL 31 L5 IS
1 EB-132HBF-UV-TP-PIC 120~277 0.19~0.09 23 > 0.97 < 12 1.18 UL, cUL 31 IS
1 EB-232EBF-1-TP-PIC 120 0.17 18 > 0.97 < 12 0.88 UL, cUL 31 L5 IS
1 EB-232EBF-2-TP-PIC 277 0.07 18 > 0.97 < 12 0.88 UL, cUL 31 L5 IS
1 EB-232HBF-1-TP-PIC 120 0.22 27 > 0.97 < 12 1.40 UL, cUL 31 L5 IS
1 EB-232HBF-2-TP-PIC 277 0.17 27 > 0.97 < 12 1.40 UL, cUL 31 L5 IS
1 EB-232EBF-UV-TP-PIC 120~277 0.17~0.07 18 > 0.97 < 12 0.88 UL, cUL 31 IS
1 EB-232HBF-UV-TP-PIC 120~277 0.22~0.17 27 > 0.97 < 12 1.40 UL, cUL 31 IS
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
T8 Straight LampsA10
** replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
* cap off one BLUE wire for one lamp application.
# add “EMI” for model with EMI filter, comply with FCC Class B.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
17W F17T8
2 EB-220-1-TP # 120 0.54 37 > 0.50 < 150 1.02 UL, cUL 30 L7 RS
2 EB-232-1-TP-SL 120 0.60 36 > 0.50 < 160 0.95 UL, cUL 30 N1 RS
2 EB-232-UV-TP-SLws 120~277 0.34~0.1 40 > 0.97 < 10 1.0 UL, cUL 32 L4 RS
2 EB-232-UV-TP-PIC 120~277 0.33~0.14 39 > 0.98 < 10 1.0 UL, cUL 12 L3 IS
2 EB-232LBF-UV-TP-PIC 120~277 0.28~0.12 33 > 0.97 < 10 0.90 UL, cUL 12 L5 IS
2 EB-232LBF-UV-TP-PIC-SL * 120~277 0.28~0.12 33 > 0.97 < 10 0.90 UL, cUL 12 L6 IS
2 EB-232EBF-UV-TP-PIC 120~277 0.24~0.11 29 > 0.97 < 12 0.77 UL, cUL 12 L5 IS
2 EB-2C72-1-TP 120 0.60 36 > 0.50 < 160 0.95 UL, CSA 30 L1 RS
2 EB-232-1-TP-PIC 120 0.33 40 > 0.99 < 10 1.00 UL, cUL 12 L3 IS
2 EB-232RIS-1-TP ws 120 0.51 32 > 0.50 < 150 0.84 UL, cUL 12 L5 IS
2 EB-232LBF-1-TP-PICws * 120 0.28 32 > 0.98 < 10 0.90 UL, cUL 12 L5 IS
2 EB-232LBF-1-TP-PIC-SL * 120 0.28 32 > 0.98 < 10 0.90 UL, cUL 12 L6 IS
2 EB-232LBF-2-TP-PIC * 277 0.12 32 > 0.98 < 10 0.90 UL, cUL 12 L5 IS
2 EB-232LBF-2-TP-PIC-SL * 277 0.12 32 > 0.98 < 10 0.90 UL, cUL 12 L6 IS
2 EB-232RIS-1-TP-SL 120 0.50 34 0.54 < 150 0.93 UL, cUL 12 N3 IS
2 EB-232EBF-1-TP-PIC 120 0.24 29 > 0.97 < 12 0.77 UL, cUL 12 L5 IS
2 EB-232EBF-2-TP-PIC 277 0.11 29 > 0.97 < 12 0.77 UL, cUL 12 L5 IS
2 EB-232HBF-1-TP-PIC 120 0.35 43 > 0.97 < 12 1.18 UL, cUL 12 L3 IS
2 EB-232HBF-2-TP-PIC 277 0.16 43 > 0.97 < 12 1.18 UL, cUL 12 L3 IS
2 EB-232HBF-UV-TP-PIC 120~277 0.35~0.16 43 > 0.97 < 12 1.18 UL, cUL 12 L5 IS
2 EB-332EBF-1-TP-PIC 120 0.29 34 > 0.97 < 12 0.88 PENDING 12 L5 IS
2 EB-332EBF-2-TP-PIC 277 0.13 34 > 0.95 < 12 0.88 PENDING 12 L5 IS
2 EB-332EBF-UV-TP-PIC 120~277 0.29~0.13 34 > 0.97 < 12 0.88 UL, cUL 12 L3 IS
2 EB-332HBF-1-TP-PIC 120 0.38 46 > 0.97 < 12 1.25 PENDING 12 L3 IS
2 EB-332HBF-2-TP-PIC 277 0.18 46 > 0.95 < 12 1.25 PENDING 12 L3 IS
2 EB-332HBF-UV-TP-PIC 120~277 0.38~0.18 46 > 0.97 < 12 1.25 UL, cUL 12 L3 IS
2 EPD-132T8M 120 0.26 33 > 0.99 < 10 0.95 UL, cUL 12 AA1 IS
Ele
ctr
onic
Balla
sts
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
T8 Straight Lamps A11
** replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
* cap off one BLUE wire for one lamp application.
# add “EMI” for model with EMI filter, comply with FCC Class B.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
17W F17T8
2 EPD-317T8M 347 0.06 28 > 0.98 < 10 0.88 UL, cUL 12 AA1 IS
2 EPD-332T8M 347 0.10 36 > 0.99 < 10 1.03 UL, cUL 12 AA1 IS
2 EPD-A32T8M 120~277 0.28~0.12 33 > 0.99 < 10 0.95 UL, cUL 12 AA1 IS
2 EPT-132T8M 120 0.30 36 > 0.99 < 15 1.05 UL, cUL 12 AA1 IS
2 EPT-332T8M 347 0.11 38 > 0.95 < 35 1.05 UL, cUL 12 AA1 IS
2 EPT-A32T8M 120~277 0.30~0.15 37 > 0.97 < 15/35 1.05 UL, cUL 12 AA1 IS
2 ESD-332T8M 347 0.11 38 > 0.97 < 15 0.97 UL, cUL 5 AA1 RS
2 ESD-A32T8M 120~277 0.30~0.14 38 > 0.98 < 15/35 0.96 UL, cUL 5 AA1 RS
3 EB-332-1-TP-PIC 120 0.48 57 > 0.99 < 10 1 UL, cUL 13 L3 IS
3 EB-332-UV-TP-PIC 120~277 0.48~0.21 56 > 0.98 < 10 1 UL, cUL 13 L3 IS
3 EB-432RIS-1-TPws 120 0.82 46 > 0.50 < 150 0.87 UL, cUL 13 L5 IS
3 EB-332LBF-1-TP-PIC 120 0.40 47 > 0.98 < 10 0.90 UL, cUL 13 L5 IS
3 EB-332LBF-2-TP-PIC 277 0.18 47 > 0.98 < 10 0.90 UL, cUL 13 L5 IS
3 EB-332EBF-1-TP-PIC 120 0.35 42 > 0.97 < 12 0.81 UL, cUL 13 L5 IS
3 EB-332EBF-2-TP-PIC 277 0.16 42 > 0.97 < 12 0.81 UL, cUL 13 L5 IS
3 EB-332EBF-UV-TP-PIC 120~277 0.35~0.16 42 > 0.97 < 12 0.81 UL, cUL 13 L5 IS
3 EB-332HBF-1-TP-PIC 120 0.48 58 > 0.97 < 12 1.18 UL, cUL 13 L3 IS
3 EB-332HBF-2-TP-PIC 277 0.22 58 > 0.97 < 12 1.18 UL, cUL 13 L3 IS
3 EB-332HBF-UV-TP-PIC 120~277 0.48~0.22 58 > 0.97 < 12 1.18 UL, cUL 13 L3 IS
3 EB-332LBF-UV-TP-PIC 120~277 0.43~0.19 51 > 0.97 < 10 0.90 UL, cUL 13 L5 IS
3 EB-432EBF-1-TP-PIC 120 0.36 43 > 0.97 < 12 0.87 UL, cUL 13 L5 IS
3 EB-432EBF-2-TP-PIC 277 0.17 43 > 0.97 < 12 0.87 UL, cUL 13 L5 IS
3 EB-432EBF-UV-TP-PIC 120~277 43 > 0.97 < 12 0.87 UL, cUL 13 L5 IS
3 EP6-132T8HO-S 120 0.42 56 > 0.99 < 10 1.32 UL, cUL 54 AA22 IS
3 EP6-332T8HO 347 0.20 69 > 0.95 < 25 1.23 UL, cUL 54 AA22 IS
3 EP6-A32T8HO 120~277 0.42~0.20 56 > 0.99 < 10 1.32 UL, cUL 54 AA1 IS
3 EPQ-132T8M 120 0.40 48 > 0.99 < 15 1 UL, cUL 52 AA1 IS
3 EPQ-332T8M 347 0.15 51 > 0.99 < 15 1 UL, cUL 52 AA1 IS
Ele
ctro
nic
Balla
sts
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
A12 T8 Straight Lamps
*** cap off one BLUE wire for three lamp application.
** replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
* cap off one BLUE wire for one lamp application.
# add “EMI” for model with EMI filter, comply with FCC Class B.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
17W F17T8
3 EPQ-A32T8M 120~277 0.42~0.21 51 > 0.92 < 15/40 1.01 UL, cUL 52 AA1 IS
3 EPT-132T8M 120 0.38 45 > 0.96 < 10 0.96 UL, cUL 13 AA1 IS
3 EPT-332T8M 347 0.14 48 > 0.98 < 25 0.96 UL, cUL 13 AA1 IS
3 EPT-A32T8M 120~277 0.40~0.20 48 > 0.98 < 10 0.96 UL, cUL 13 AA1 IS
3 ESPQ-132T8HO 120 0.50 60 > 0.99 < 10 0.77 UL, cUL 57 AA29 RS
3 ESPQ-332T8HO 347 0.18 61 > 0.99 < 10 0.77 UL, cUL 57 AA29 RS
3 ESPQ-A32T8HO 120~277 0.53~0.23 63 > 0.99 < 10 0.77 UL, cUL 57 AA3 RS
4 EB-432-1-TP-PIC 120 0.61 73 > 0.99 < 10 1.00 UL, cUL 14 L3 IS
4 EB-432RIS-1-TPws 120 0.96 60 > 0.50 < 140 0.88 UL, cUL 14 L5 IS
4 EB-432LBF-1-TP-PICws *** 120 0.51 60 > 0.98 < 10 0.90 UL, cUL 14 L5 IS
4 EB-432LBF-2-TP-PIC *** 277 0.22 60 > 0.98 < 10 0.90 UL, cUL 14 L5 IS
4 EB-432EBF-1-TP-PIC 120 0.43 52 > 0.97 < 12 0.81 UL, cUL 14 L5 IS
4 EB-432EBF-2-TP-PIC 277 0.20 52 > 0.97 < 12 0.81 UL, cUL 14 L5 IS
4 EB-432-UV-TP-PIC 120~277 0.60~0.26 69 > 0.95 < 10 1.0 UL, cUL 14 L3 IS
4 EB-432LBF-UV-TP-PIC ** 120~277 0.51~0.23 61 > 0.97 < 10 0.90 UL, cUL 14 L5 IS
4 EB-432EBF-UV-TP-PIC 120~277 0.43~0.20 52 > 0.97 < 12 0.81 UL, cUL 14 L5 IS
4 EP6-332T8HO 347 0.27 92 > 0.95 < 25 1.35 UL, cUL 55 AA22 IS
4 EPQ-132T8M 120 0.48 57 > 0.99 < 15 0.92 UL, cUL 53 AA1 IS
4 EPQ-332T8M 347 0.18 61 > 0.99 < 10 0.92 UL, cUL 14 AA1 IS
4 EPQ-A32T8M 120~277 0.48~0.24 60 > 0.93 < 15/35 0.92 UL, cUL 14 AA1 IS
4 ESPQ-132T8HO 120 0.67 80 > 0.99 < 10 0.75 UL, cUL 42 AA29 RS
4 ESPQ-332T8HO 347 0.22 77 > 0.99 < 10 0.75 UL, cUL 42 AA29 RS
4 ESPQ-A32T8HO 120~277 0.67~0.29 80 > 0.99 < 10 0.75 UL, cUL 42 AA3 RS
6 EP6-132T8HO-S 120 0.84 112 > 0.99 < 10 1.32 UL, cUL 56 AA22 IS
6 EP6-332T8HO 347 0.40 138 > 0.98 < 25 1.23 UL, cUL 56 AA22 IS
6 EP6-A32T8HO 120~277 0.84~0.40 112 > 0.99 < 10 1.32 UL, cUL 56 AA22 IS
Ele
ctr
onic
Balla
sts
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
A13T8 Straight Lamps
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
18W
F18T8 24”
1 EB-120-1-TP 120 0.27 18 > 0.50 < 150 0.95 UL, cUL 28 X1 RS
1 EB-120-1-TP-EMI 120 0.27 18 > 0.50 < 150 0.95 UL, cUL 28 L7 RS
2 EB-220-1-TP # 120 0.50 34 > 0.50 < 150 0.92 UL, cUL 30 L7 RS
1 EB-126-1-TPws
120 0.27 17 > 0.50 < 160 0.95 UL, cUL 28
S1 RS
1 EB-126-1-TP-LC L2 RS
1 EB-126-1-TP-LC-TBws U2 RS
1 EB-126-1-TP-LC-TBws N1 RS
1 EB-126-1-TP-SL U3 RS
1 EB-126-1-TP-SL-TBws L8 RS
F18T8 26” 1
EB-126-1-TPws
120 0.28 18 > 0.50 < 160 1.0 UL, cUL 28
S1 RS
EB-126-1-TP-LC L2 RS
EB-126-1-TP-LC-TBws U2 RS
EB-126-1-TP-SL N1 RS
EB-126-1-TP-SL-TBws U3 RS
EB-126-1-TP-SC * L8 RS
F18T8 28” 1
EB-126-1-TPws
120 0.29 18 > 0.50 < 160 1.0 UL, cUL 28
S1 RS
EB-126-1-TP-LC L2 RS
EB-126-1-TP-LC-TBws U2 RS
EB-126-1-TP-SL N1 RS
EB-126-1-TP-SL-TBws U3 RS
EB-126-1-TP-SC * L8 RS
F18T8 30” 1
EB-126-1-TPws
120 0.30 19 > 0.50 < 160 1.05 UL, cUL 28
S1 RS
EB-126-1-TP-LC L2 RS
EB-126-1-TP-LC-TBws U2 RS
EB-126-1-TP-SL N1 RS
EB-126-1-TP-SL-TBws U3 RS
EB-126-1-TP-SC * L8 RS
* replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
# add “EMI” for model with EMI filter, comply with FCC Class B.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
A14 T8 Straight Lamps
* replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
# add “EMI” for model with EMI filter, comply with FCC Class B.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
25W F25T8
1 EB-126-1-TPws
120 0.41 28 > 0.50 < 130 0.95 UL, cUL 28
S1 RS
1 EB-126-1-TP-LC L2 RS
1 EB-126-1-TP-LC-TBws U2 RS
1 EB-126-1-TP-SL N1 RS
1 EB-126-1-TP-SL-TBws U3 RS
1 EB-126-1-TP-SC * L8 RS
1 EB-132-1-TP 120 0.41 28 > 0.50 < 130 1.05 UL, cUL 28 L7 RS
1 EB-132-1-TP-PIC 120 0.25 30 > 0.99 < 10 1.0 UL, cUL 31 L3 IS
1 EB-132-UV-TP-SL 120~277 0.24~0.10 28 > 0.98 < 10 1.0 UL, cUL 6 L4 RS
1 EB-132-UV-TP-PIC 120~277 0.26~0.11 30 > 0.98 < 10 1.0 UL, cUL 31 L3 IS
1 EB-132LBF-UV-TP-PIC 120~277 0.20~0.09 24 > 0.99 < 10 0.90 UL, cUL 31 L5 IS
1 EB-132LBF-UV-TP-PIC-SL 120~277 0.20~0.09 24 > 0.99 < 10 0.90 UL, cUL 31 L6 IS
1 EB-132EBF-UV-TP-PIC 120~277 0.19~0.08 23 > 0.98 < 10 0.77 UL, cUL 31 L5 IS
1 EB-132HBF-UV-TP-PIC 120~277 0.27~0.12 32 > 0.98 < 10 1.18 UL, cUL 31 L5 IS
1 EB-232RIS-1-TPws 120 0.45 27 > 0.50 < 150 0.95 UL, cUL 31 L5 IS
1 EB-132LBF-1-TP-PIC 120 0.20 24 > 0.99 < 10 0.90 UL, cUL 31 L5 IS
1 EB-132LBF-1-TP-PIC-SL 120 0.20 24 > 0.99 < 10 0.90 UL, cUL 31 L6 IS
1 EB-132LBF-2-TP-PIC 277 0.09 24 > 0.99 < 10 0.90 UL, cUL 31 L5 IS
1 EB-132LBF-2-TP-PIC-SL 277 0.09 24 > 0.99 < 10 0.90 UL, cUL 31 L6 IS
1 EB-132-2-TP-PIC-SL 277 0.10 27 > 0.98 < 10 0.95 UL, cUL 31 N3 IS
1 EB-232RIS-1-TP-SL 120 0.47 31 0.57 < 150 1.05 UL, cUL 31 N3 IS
1 EB-132EBF-1-TP-PIC 120 0.19 23 > 0.98 < 10 0.77 UL, cUL 31 L5 IS
1 EB-132EBF-2-TP-PIC 277 0.08 23 > 0.98 < 10 0.77 UL, cUL 31 L5 IS
1 EB-132HBF-1-TP-PIC 120 0.27 32 > 0.98 < 10 1.18 UL, cUL 31 L3 IS
1 EB-132HBF-2-TP-PIC 277 0.12 32 > 0.98 < 10 1.18 UL, cUL 31 L3 IS
1 EB-232EBF-1-TP-PIC 120 0.21 25 > 0.98 < 10 0.88 UL, cUL 31 L5 IS
1 EB-232EBF-2-TP-PIC 277 0.09 25 > 0.98 < 10 0.88 UL, cUL 31 L5 IS
1 EB-232EBF-UV-TP-PIC 120~277 0.21~0.09 25 > 0.98 < 10 0.88 UL, cUL 31 L5 IS
1 EB-232HBF-1-TP-PIC 120 0.29 39 > 0.98 < 10 1.34 UL, cUL 31 L3 IS
1 EB-232HBF-2-TP-PIC 277 0.14 39 > 0.98 < 10 1.34 UL, cUL 31 L3 IS
1 EB-232HBF-UV-TP-PIC 120~277 0.29~0.14 39 > 0.98 < 10 1.34 UL, cUL 31 L3 IS
1 EPD-132T8M 120 0.25 30 > 0.99 < 10 0.99 UL, cUL 31 AA1 IS
1 EPD-332T8M 347 0.08 30 > 0.98 < 10 1.13 UL, cUL 31 AA1 IS
1 EPD-A32T8M 120~277 0.25~0.11 30 > 0.99 < 10/15 1.13 UL, cUL 31 AA1 IS
1 EPS-132T8M 120 0.25 30 > 0.99 < 10 1.13 UL, cUL 31 AA1 IS
1 ESD-332T8M 347 0.08 30 > 0.98 < 15 1.1 UL, cUL 6 AA1 RS
Ele
ctr
onic
Balla
sts
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FORFLUORESCENT LAMPS
A15T8 Straight Lamps
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
25W F25T8
1 ESD-A32T8M 120~277 0.25~0.13 30 > 0.99 < 10/20 1.1 UL, cUL 6 AA1 RS
2 EB-2C72-1-TP 120 0.72 48 > 0.50 < 150 0.95 UL, CSA 30 L1 RS
2 EB-232-1-TP-SL 120 0.72 48 > 0.50 < 150 0.95 UL, cUL 30 N1 RS
2 EB-240-1-TP 120 0.81 52 > 0.50 < 150 1.05 UL, cUL 30 L1 RS
2 EB-232-1-TP-PIC 120 0.46 55 > 0.99 < 10 1.0 UL, cUL 12 L3 IS
2 EB-232RIS-1-TP 120 0.64 42 > 0.50 < 130 0.81 UL, cUL 12 L5 IS
2 EB-232LBF-1-TP-PICws ** 120 0.39 46 > 0.99 < 10 0.90 UL, cUL 12 L5 IS
2 EB-232LBF-1-TP-PIC-SL ** 120 0.39 46 > 0.99 < 10 0.90 UL, cUL 12 L6 IS
2 EB-232LBF-2-TP-PIC ** 277 0.17 46 > 0.99 < 10 0.90 UL, cUL 12 L5 IS
2 EB-232LBF-2-TP-PIC-SL ** 277 0.17 46 > 0.99 < 10 0.90 UL, cUL 12 L6 IS
2 EB-232RIS-1-TP-SL 120 0.65 47 > 0.59 < 150 0.90 UL, cUL 12 N3 IS
2 EB-232EBF-1-TP-PIC 120 0.33 40 > 0.98 < 10 0.80 UL, cUL 12 L5 IS
2 EB-232EBF-2-TP-PIC 277 0.15 40 > 0.98 < 10 0.80 UL, cUL 12 L5 IS
2 EB-232HBF-1-TP-PIC 120 0.48 57 > 0.98 < 10 1.18 UL, cUL 12 L3 IS
2 EB-232HBF-2-TP-PIC 277 0.21 57 > 0.98 < 10 1.18 UL, cUL 12 L3 IS
2 EB-232-UV-TP-SL 120~277 0.47~0.20 55 > 0.98 < 10 1.0 UL, cUL 32 L4 RS
2 EB-232-UV-TP-PIC 120~277 0.47~0.20 55 > 0.98 < 10 1.0 UL, cUL 12 L3 IS
2 EB-232LBF-UV-TP-PIC 120~277 0.39~0.17 46 > 0.99 < 10 0.90 UL, cUL 12 L5 IS
2 EB-232LBF-UV-TP-PIC-SL * 120~277 0.39~0.17 46 > 0.99 < 10 0.90 UL, cUL 12 L6 IS
2 EB-232EBF-UV-TP-PIC 120~277 0.33~0.15 40 > 0.98 < 10 0.80 UL, cUL 12 L5 IS
2 EB-232HBF-UV-TP-PIC 120~277 0.48~0.21 57 > 0.98 < 10 1.18 UL, cUL 12 L5 IS
2 EB-332EBF-1-TP-PIC 120 0.38 45 > 0.98 < 10 0.87 UL, cUL 13 L5 IS
2 EB-332EBF-2-TP-PIC 277 0.17 45 > 0.98 < 10 0.87 UL, cUL 13 L5 IS
2 EB-332HBF-1-TP-PIC 120 0.52 62 > 0.98 < 10 1.24 UL, cUL 13 L3 IS
2 EB-332HBF-2-TP-PIC 277 0.23 62 > 0.98 < 10 1.24 UL, cUL 13 L3 IS
2 EB-332EBF-UV-TP-PIC 120~277 45 > 0.98 < 10 0.87 UL, cUL 12 L3 IS
2 EB-332HBF-UV-TP-PIC 120~277 62 > 0.98 < 10 1.24 UL, cUL 12 L3 IS
2 EPD-132T8M 120 0.37 46 > 0.99 < 10 0.90 UL, cUL 12 AA1 IS
2 EPD-332T8M 347 0.13 47 > 0.99 < 10 0.95 UL, cUL 12 AA1 IS
2 EPD-A32T8M 120~277 0.37~0.16 46 > 0.99 < 10 0.90 UL, cUL 12 AA1 IS
* replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
# add “EMI” for model with EMI filter, comply with FCC Class B.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
FLUORESCENT LAMPS
A16T8 Straight Lamps
Ele
ctr
onic
Balla
sts
* replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
** cap off one BLUE wire for one lamp application.
*** cap off one BLUE wire for three lamp application.
ws This item is well stocked
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
25W F25T8
2 EPQ-332T8M 347 0.15 51 > 0.98 < 20 1.03 UL, cUL 12 AA1 IS
2 EPT-132T8M 120 0.41 49 > 0.99 < 10 1.03 UL, cUL 12 AA1 IS
2 EPT-A32T8M 120~277 0.42~0.20 51 > 0.99 < 10 1.02 UL, cUL 12 AA1 IS
2 ESD-332T8M 347 0.15 52 > 0.99 < 10 0.95 UL, cUL 5 AA1 RS
2 ESD-A32T8M 120~277 0.40~0.19 50 > 0.98 < 10/15 0.93 UL, cUL 5 AA1 RS
3 EB-332-1-TP-PIC 120 0.67 80 > 0.99 < 10 1.0 UL, cUL 13 L3 IS
3 EB-432RIS-1-TPws 120 1.04 63 > 0.50 < 130 0.84 UL, cUL 13 L5 IS
3 EB-332LBF-1-TP-PIC 120 0.58 69 > 0.99 < 10 0.90 UL, cUL 13 L5 IS
3 EB-332LBF-2-TP-PIC 277 0.26 69 > 0.99 < 10 0.90 UL, cUL 13 L5 IS
3 EB-332EBF-1-TP-PIC 120 0.48 57 > 0.98 < 10 0.80 UL, cUL 13 L5 IS
3 EB-332EBF-2-TP-PIC 277 0.21 57 > 0.98 < 10 0.80 UL, cUL 13 L5 IS
3 EB-332EBF-UV-TP-PIC 120~277 0.48~0.21 57 > 0.98 < 10 0.80 UL, cUL 13 L5 IS
3 EB-332HBF-1-TP-PIC 120 0.69 92 > 0.98 < 10 1.18 UL, cUL 13 L3 IS
3 EB-332HBF-2-TP-PIC 277 0.30 92 > 0.98 < 10 1.18 UL, cUL 13 L3 IS
3 EB-332HBF-UV-TP-PIC 120~277 0.69~0.30 92 > 0.98 < 10 1.18 UL, cUL 13 L3 IS
3 EB-332LBF-UV-TP-PIC 120~277 0.58~0.26 70 > 0.98 < 10 0.90 UL, cUL 13 L5 IS
3 EB-332-UV-TP-PIC 120~277 0.68~0.29 80 > 0.98 < 10 1.0 UL, cUL 13 L3 IS
3 EB-432EBF-1-TP-PIC 120 0.51 60 > 0.98 < 10 0.85 UL, cUL 13 L5 IS
3 EB-432EBF-2-TP-PIC 277 0.23 60 > 0.98 < 10 0.85 UL, cUL 13 L5 IS
3 EB-432EBF-UV-TP-PIC 120~277 0.51~0.23 60 > 0.98 < 10 0.85 UL, cUL 13 L5 IS
4 EB-432-1-TP-PIC 120 0.89 106 > 0.99 < 10 1.0 UL, cUL 14 L3 IS
4 EB-432RIS-1-TPws 120 1.22 77 > 0.50 < 130 0.80 UL, cUL 14 L5 IS
4 EB-432LBF-1-TP-PICws ** 120 0.74 88 > 0.99 < 10 0.90 UL, cUL 14 L5 IS
4 EB-432LBF-1-TP-PICws ** 120 0.32 88 > 0.99 < 10 090 UL, cUL 14 L5 IS
4 EB-432EBF-1-TP-PICws 120 0.60 72 > 0.98 < 10 0.80 UL, cUL 14 L5 IS
4 EB-432EBF-2-TP-PIC 277 0.27 72 > 0.97 < 10 0.80 UL, cUL 14 L5 IS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
FLUORESCENT LAMPS
A17T8 Straight Lamps
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
30W F30T8
1 EPD-132T8M 120 0.29 35 > 0.99 < 10 1.08 UL, cUL 31 AA1 IS
1 EPD-332T8M 347 0.10 36 > 0.99 < 10 1.11 UL, cUL 31 AA1 IS
1 EPD-A32T8M 120~277 0.29~0.12 35 > 0.99 < 10/15 1.08 UL, cUL 31 AA1 IS
1 ESD-332T8M 347 0.16 36 > 0.96 < 15 1.09 UL, cUL 6 AA1 RS
1 ESD-A32T8M 120~277 0.29~0.16 35 > 0.99 < 10/15 1.08 UL, cUL 6 AA1 RS
2 EPD-132T8M 120 0.47 56 > 0.99 < 10 0.93 UL, cUL 12 AA1 IS
2 EPD-332T8M 347 0.16 56 > 0.99 < 10 0.96 UL, cUL 12 AA1 IS
2 EPD-A32T8M 120~277 0.47~0.20 56 > 0.99 < 10 0.93 UL, cUL 12 AA1 IS
2 ESD-332T8M 347 0.24 56 > 0.98 < 20 0.93 UL, cUL 5 AA1 RS
2 ESD-A32T8M 120~277 0.46~0.24 56 > 0.98 < 10/15 0.93 UL, cUL 5 AA1 RS
3 EP6-A32T8HO 120~277 0.87~0.38 104 > 0.99 < 10 1.2 UL, cUL 54 AA22 IS
3 ESPQ-132T8HO 120 0.86 103 > 0.99 < 10 1.13 UL, cUL 57 AA29 RS
3 ESPQ-332T8HO 347 0.31 106 > 0.99 < 10 1.17 UL, cUL 57 AA29 RS
4 ESPQ-132T8HO 120 1.11 133 > 0.99 < 10 1.1 UL, cUL 42 AA29 RS
4 ESPQ-332T8HO 347 0.41 140 > 0.99 < 10 1.16 UL, cUL 42 AA29 RS
6 EP6-A32T8HO 120~277 1.73~0.76 208 > 0.99 < 10 1.2 UL, cUL 56 AA22 IS
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
Ele
ctr
onic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A18
ELECTRONIC BALLAST FOR
FLUORESCENT LAMPS
T8 Straight Lamps
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
32W F32T8
1 EB-126-1-TPws 120 0.51 35 > 0.50 < 130 1.1 UL, cUL 28 S1 RS
1 EB-126-1-TP-LC 120 0.51 35 > 0.50 < 130 1.1 UL, cUL 28 L2 RS
1 EB-126-1-TP-LC-TBws 120 0.51 35 > 0.50 < 130 1.1 UL, cUL 28 U2 RS
1 EB-126-1-TP-SL 120 0.51 35 > 0.50 < 130 1.1 UL, cUL 28 N1 RS
1 EB-126-1-TP-SL-TBws 120 0.51 35 > 0.50 < 130 1.1 UL, cUL 28 U3 RS
1 EB-126-1-TP-SC * 120 0.51 35 > 0.50 < 130 1.1 UL, cUL 28 L8 RS
1 EB-132-1-TP 120 0.48 32 > 0.50 < 130 0.95 UL, cUL 28 L7 RS
1 EB-132-1-TP-PIC 120 0.33 39 > 0.99 < 10 1.2 UL, cUL 31 L3 IS
1 EB-132-2-TP-PIC-SL 277 0.12 33 > 0.98 < 10 1.0 UL, cUL 28 N3 RS
1 EB-132EBF-1-TP-PIC 120 0.23 27 > 0.99 < 10 0.77 UL, cUL 31 L5 IS
1 EB-132EBF-2-TP-PIC 277 0.10 27 > 0.99 < 10 0.77 UL, cUL 31 L5 IS
1 EB-132HBF-1-TP-PIC 120 0.32 41 > 0.99 < 10 1.18 UL, cUL 31 L3 IS
1 EB-132HBF-2-TP-PIC 277 0.15 41 > 0.99 < 10 1.18 UL, cUL 31 L3 IS
1 EB-132LBF-1-TP-PIC 120 0.26 30 > 0.99 < 10 0.88 UL, cUL 31 L5 IS
1 EB-132LBF-1-TP-PIC-SL 120 0.26 30 > 0.99 < 10 0.88 UL, cUL 31 L6 IS
1 EB-132LBF-2-TP-PIC 277 0.11 30 > 0.99 < 10 0.88 UL, cUL 31 L5 IS
1 EB-132LBF-2-TP-PIC-SL 277 0.11 30 > 0.99 < 10 0.88 UL, cUL 31 L6 IS
1 EB-132-UV-TP-SLws 120~277 0.30~0.13 35 > 0.98 < 10 1.0 UL, cUL 6 L4 RS
1 EB-132-UV-TP-PIC 120~277 0.31~0.14 37 > 0.98 < 10 1.0 UL, cUL 31 L3 IS
1 EB-132LBF-UV-TP-PIC 120~277 0.25~0.11 30 > 0.99 < 10 0.88 UL, cUL 31 L5 IS
1 EB-132LBF-UV-TP-PIC-SL 120~277 0.25~0.11 30 > 0.99 < 10 0.88 UL, cUL 31 L6 IS
1 EB-132EBF-UV-TP-PIC 120~277 0.23~0.10 27 > 0.99 < 10 0.77 UL, cUL 31 L5 IS
1 EB-132HBF-UV-TP-PIC 120~277 0.32~0.15 41 > 0.99 < 10 1.18 UL, cUL 31 L3 IS
1 EPD-132T8M 120 0.30 36 > 0.99 < 10 1.06 UL, cUL 31 AA1 IS
1 EPD-332T8M 347 0.10 37 > 0.99 < 10 1.08 UL, cUL 31 AA1 IS
1 EPD-A32T8M 120~277 0.30~0.13 36 > 0.99 < 10 1.06 UL, cUL 31 AA1 IS
1 EPS-132T8M 120 0.28 33 > 0.99 < 10 0.9 UL, cUL 31 AA1 IS
1 ESD-332T8M 347 0.11 37 > 0.99 < 10 1.06 UL, cUL 6 AA1 RS
1 ESD-A32T8M 120~277 0.30~0.15 36 > 0.97 < 10/15 1.05 UL, cUL 6 AA1 RS
1 EB-232EBF-UV-TP-PIC 120~277 0.26~0.12 32 > 0.99 < 10 0.85 UL, cUL 31 L5 IS
1 EB-232EBF-1-TP-PIC 120 0.26 32 > 0.99 < 10 0.85 UL, cUL 31 L5 IS
1 EB-232EBF-2-TP-PIC 277 0.12 32 > 0.99 < 10 0.85 UL, cUL 31 L5 IS
1 EB-232HBF-1-TP-PIC 120 0.39 46 > 0.99 < 10 1.42 UL, cUL 31 L3 IS
1 EB-232HBF-2-TP-PIC 277 0.18 46 > 0.99 < 10 1.42 UL, cUL 31 L3 IS
1 EB-232HBF-UV-TP-PIC 120~277 0.39~0.18 46 > 0.99 < 10 1.42 UL, cUL 31 L3 IS
1 EB-232RIS-1-TPws 120 0.55 35 > 0.50 < 150 1.1 UL, cUL 31 L5 IS
1 EB-232RIS-1-TP-SL 120 0.55 37 0.57 < 150 1.00 UL, cUL 31 N3 IS
* replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A19
ELECTRONIC BALLAST FOR
FLUORESCENT LAMPS
T8 Straight Lamps
ws This item is well stocked
* replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
** cap off one BLUE wire for one lamp application.
*** cap off one BLUE wire for three lamp application.
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
32W F32T8
2 EB-2C72-1-TP 120 0.89 62 > 0.50 < 130 0.97 UL, CSA 30 L1 RS
2 EB-232-1-TP-SL 120 0.89 62 > 0.50 < 130 0.90 UL, cUL 30 N1 RS
2 EB-240-1-TP 120 1.0 68 > 0.50 < 150 1.05 UL, cUL 30 L1 RS
2 EB-232-1-TP-PIC 120 0.62 74 > 0.99 < 10 1.0 UL, cUL 12 L3 IS
2 EB-232EBF-UV-TP-PIC 120~277 0.42~0.18 50 > 0.99 < 10 0.77 UL, cUL 12 L5 IS
2 EB-232EBF-1-TP-PIC 120 0.42 76 > 0.99 < 10 0.77 UL, cUL 12 L5 IS
2 EB-232EBF-2-TP-PIC 277 0.18 76 > 0.99 < 10 0.77 UL, cUL 12 L5 IS
2 EB-232HBF-1-TP-PIC 120 0.63 50 > 0.99 < 10 1.18 UL, cUL 12 L3 IS
2 EB-232HBF-2-TP-PIC 277 0.28 50 > 0.99 < 10 1.18 UL, cUL 12 L3 IS
2 EB-232HBF-UV-TP-PIC 120~277 0.63~0.28 76 > 0.99 < 10 1.18 UL, cUL 12 L3 IS
2 EB-332HBF-UV-TP-PIC 120~277 0.68~0.30 81 > 0.99 < 10 1.30 UL, cUL 12 L3 IS
2 EB-232LBF-1-TP-PICws ** 120 0.49 58 > 0.99 < 10 0.88 UL, cUL 12 L5 IS
2 EB-232LBF-1-TP-PIC-SL ** 120 0.49 58 > 0.99 < 10 0.88 UL, cUL 12 L6 IS
2 EB-232LBF-2-TP-PIC ** 277 0.22 58 > 0.99 < 10 0.88 UL, cUL 12 L5 IS
2 EB-232LBF-2-TP-PIC-SL ** 277 0.22 58 > 0.99 < 10 0.88 UL, cUL 12 L6 IS
2 EB-232LBF-UV-TP-PIC 120~277 0.49~0.22 59 > 0.99 < 10 0.88 UL, cUL 12 L5 IS
2 EB-232LBF-UV-TP-PIC-SL * 120~277 0.49~0.22 59 > 0.99 < 10 0.88 UL, cUL 12 L6 IS
2 EB-232RIS-1-TPws 120 0.79 54 > 0.50 < 120 0.83 UL, cUL 12 L5 IS
2 EB-232RIS-1-TP-SL 120 0.78 57 > 0.60 < 150 0.88 UL, cUL 12 N3 IS
2 EB-332EBF-1-TP-PIC 120 0.48 57 > 0.99 < 10 0.86 UL, cUL 12 L5 IS
2 EB-332EBF-2-TP-PIC 277 0.21 57 > 0.99 < 10 0.86 UL, cUL 12 L5 IS
2 EB-332EBF-UV-TP-PIC 120~277 0.48~0.21 57 > 0.99 < 10 0.86 UL, cUL 12 L5 IS
2 EB-332HBF-1-TP-PIC 120 0.68 81 > 0.99 < 10 1.30 UL, cUL 12 L3 IS
2 EB-332HBF-2-TP-PIC 277 0.30 81 > 0.99 < 10 1.30 UL, cUL 12 L3 IS
2 EPD-132T8M 120 0.48 57 > 0.99 < 10 0.88 UL, cUL 12 AA1 IS
2 EPD-332T8M 347 0.18 57 > 0.99 < 10 0.88 UL, cUL 12 AA1 IS
2 EPD-A32T8M 120~277 0.48~0.20 57 > 0.99 < 10 0.88 UL, cUL 12 AA1 IS
2 EPT-132T8M 120 0.53 64 > 0.99 < 10 0.96 UL, cUL 12 AA1 IS
2 EPT-332T8M 347 0.19 64 > 0.99 < 10 0.96 UL, cUL 12 AA1 IS
2 EPT-A32T8M 120~277 0.53~0.25 64 > 0.99 < 10 0.97 UL, cUL 12 AA1 IS
2 ESD-A32T8M 120~277 0.52~0.23 64 > 0.99 < 10 0.89 UL, cUL 5 AA1 RS
3 EB-332-1-TP-PIC 120 0.92 110 > 0.99 < 10 1.0 UL, cUL 13 L3 IS
3 EB-332EBF-1-TP-PIC 120 0.62 74 > 0.99 < 10 0.77 UL, cUL 13 L5 IS
3 EB-332EBF-2-TP-PIC 277 0.27 74 > 0.99 < 10 0.77 UL, cUL 13 L5 IS
3 EB-332EBF-UV-TP-PIC 120~277 0.62~0.27 74 > 0.99 < 10 0.77 UL, cUL 13 L5 IS
3 EB-332HBF-1-TP-PIC 120 0.90 108 > 0.99 < 10 1.18 UL, cUL 13 L3 IS
3 EB-332HBF-2-TP-PIC 277 0.40 108 > 0.99 < 10 1.18 UL, cUL 13 L3 IS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A20T8 Straight Lamps
ELECTRONIC BALLAST FOR
FLUORESCENT LAMPS
ws This item is well stocked
* replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
** cap off one BLUE wire for one lamp application.
*** cap off one BLUE wire for three lamp application.
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
32W F32T8
3 EB-332HBF-UV-TP-PIC 120~277 0.90~0.40 100 > 0.99 < 10 1.18 UL, cUL 13 L3 IS
3 EB-332LBF-1-TP-PIC 120 0.75 88 > 0.99 < 10 0.88 UL, cUL 13 L5 IS
3 EB-332LBF-2-TP-PIC 277 0.32 88 > 0.99 < 10 0.88 UL, cUL 13 L5 IS
3 EB-332LBF-UV-TP-PIC 120~277 0.76~0.33 90 > 0.99 < 10 0.88 UL, cUL 13 L5 IS
3 EB-332-UV-TP-PIC 120~277 0.88~0.38 105 > 0.99 < 10 1.0 UL, cUL 13 L3 IS
3 EB-432EBF-1-TP-PIC 120 0.67 79 > 0.99 < 10 0.82 UL, cUL 13 L5 IS
3 EB-432EBF-2-TP-PIC 277 0.29 79 > 0.99 < 10 0.82 UL, cUL 13 L5 IS
3 EB-432EBF-UV-TP-PIC 120~277 0.67~0.29 79 > 0.99 < 10 0.82 UL, cUL 13 L5 IS
3 EB-432RIS-1-TPws 120 1.29 83 > 0.50 < 130 0.87 UL, cUL 13 L5 IS
3 EP6-132T8HO-S 120 0.87 104 > 0.99 < 10 1.2 UL, cUL 54 AA22 IS
3 EP6-332T8HO 347 0.30 104 > 0.99 < 15 1.18 UL, cUL 54 AA22 IS
3 EPQ-132T8M 120 0.73 87 > 0.99 < 10 0.94 UL, cUL 52 AA1 IS
3 EPQ-332T8M 347 0.25 87 > 0.99 < 10 0.95 UL, cUL 52 AA1 IS
3 EPQ-A32T8M 120~277 0.74~0.33 90 > 0.99 < 10/15 0.96 UL, cUL 52 AA1 IS
3 EPT-132T8M 120 0.69 83 > 0.99 < 10 0.96 UL, cUL 13 AA1 IS
3 EPT-332T8M 347 0.24 83 > 0.99 < 10 0.89 UL, cUL 13 AA1 IS
3 EPT-A32T8M 120~277 0.69~0.31 83 > 0.99 < 10 0.89 UL, cUL 13 AA1 IS
3 ESPQ-132T8HO 120 0.87 105 > 0.99 < 10 1.2 UL, cUL 57 AA29 RS
3 ESPQ-332T8HO 347 0.30 102 > 0.99 < 10 1.2 UL, cUL 57 AA29 RS
3 ESPQ-A32T8HO 120~277 0.90~0.39 107 > 0.99 < 10 1.2 UL, cUL 57 AA3 RS
4 EB-432EBF-1-TP-PIC 120 0.81 96 > 0.99 < 10 0.77 UL, cUL 14 L5 IS
4 EB-432EBF-2-TP-PIC 277 0.35 96 > 0.99 < 10 0.77 UL, cUL 14 L5 IS
4 EB-432LBF-1-TP-PICws *** 120 0.93 112 > 0.99 < 10 0.88 UL, cUL 14 L5 IS
4 EB-432LBF-2-TP-PIC *** 277 0.40 112 > 0.99 < 10 0.88 UL, cUL 14 L5 IS
4 EB-432RIS-1-TPws 120 1.47 99 > 0.99 < 120 0.80 UL, cUL 14 L5 IS
4 EB-432LBF-UV-TP-PIC ** 120~277 0.93~0.40 112 > 0.99 < 10 0.88 UL, cUL 14 L5 IS
4 EB-432-UV-TP-PIC 120~277 1.15~0.50 135 > 0.99 < 10 1.0 UL, cUL 14 L3 IS
4 EP6-332T8HO 347 0.39 135 > 0.99 < 15 1.25 UL, cUL 55 AA22 IS
4 EPQ-132T8M 120 0.88 106 > 0.99 < 10 0.87 UL, cUL 53 AA1 IS
4 EPQ-332T8M 347 0.30 105 > 0.99 < 10 0.87 UL, cUL 14 AA1 IS
4 EPQ-A32T8M 120~277 0.88~0.39 107 > 0.99 < 10 0.87 UL, cUL 52 AA1 IS
4 ESPQ-132T8HO 120 1.13 136 > 0.99 < 10 1.18 UL, cUL 42 AA29 RS
4 ESPQ-332T8HO 347 0.40 138 > 0.99 < 10 1.18 UL, cUL 42 AA29 RS
4 ESPQ-A32T8HO 120~277 1.14~0.50 137 > 0.99 < 10 1.18 UL, cUL 42 AA3 RS
6 EP6-132T8HO-S 120 1.73 208 > 0.99 < 10 1.2 UL, cUL 56 AA22 IS
6 EP6-332T8HO 347 0.60 208 > 0.99 < 10 1.18 UL, cUL 56 AA22 IS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Ele
ctr
onic
Balla
sts
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A21T8 Straight Lamps
ELECTRONIC BALLAST FOR
FLUORESCENT LAMPS
ws This item is well stocked
* replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
** cap off one BLUE wire for one lamp application.
*** cap off one BLUE wire for three lamp application.
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
40W F40T8
1 EB-142T-1-TP-SC * 120 0.57 39 > 0.50 < 130 0.88 UL, cUL 28 L8 RS
1 EB-232LBF-1-TP-PIC 120 0.37 43 > 0.99 < 10 1.0 UL, cUL 31 L5 IS
1 EB-232LBF-1-TP-PIC-SL 120 0.37 43 > 0.99 < 10 1.0 UL, cUL 31 L6 IS
1 EB-232LBF-2-TP-PIC 277 0.16 43 > 0.99 < 10 1.0 UL, cUL 31 L5 IS
1 EB-232LBF-2-TP-PIC-SL 277 0.16 43 > 0.99 < 10 1.0 UL, cUL 31 L6 IS
1 EB-232LBF-UV-TP-PIC 120~277 0.16~0.37 43 > 0.99 < 10 1.0 UL, cUL 31 L5 IS
1 EB-232RIS-1-TP-SL 120 0.60 42 > 0.57 < 150 1.0 UL, cUL 31 N3 IS
1 EB-232EBF-1-TP-PIC 120 0.32 38 > 0.98 < 10 0.93 UL, cUL 31 L5 IS
1 EB-232EBF-2-TP-PIC 277 0.14 38 > 0.98 < 10 0.93 UL, cUL 31 L5 IS
1 EB-232EBF-UV-TP-PIC 120~277 0.32~0.14 38 > 0.98 < 10 0.93 UL, cUL 31 L5 IS
1 EB-232HBF-1-TP-PIC 120 0.46 55 > 0.98 < 10 1.30 UL, cUL 31 L3 IS
1 EB-232HBF-2-TP-PIC 277 0.21 55 > 0.98 < 10 1.30 UL, cUL 31 L3 IS
1 EB-232HBF-UV-TP-PIC 120~277 0.46~0.21 55 > 0.98 < 10 1.30 UL, cUL 31 L3 IS
1 EPD-140T8M 120 0.37 44 > 0.99 < 10 1.03 UL, cUL 31 AA1 IS
1 EPD-332T8M 347 0.12 43 > 0.99 < 10 1 UL, cUL 31 AA1 IS
1 EPD-A32T8M 120~277 0.37~0.16 44 > 0.99 < 10 1.03 UL, cUL 31 AA1 IS
1 ESD-A32T8M 120~277 0.37~0.19 45 > 0.98 < 10/15 1 UL, cUL 6 AA1 RS
2 EB-332LBF-1-TP-PIC 120 0.65 77 > 0.98 < 10 0.88 UL, cUL 12 L5 IS
2 EB-332LBF-2-TP-PIC 277 0.28 77 > 0.98 < 10 0.88 UL, cUL 12 L5 IS
2 EB-332LBF-UV-TP-PIC 120~277 0.28~0.65 77 > 0.98 < 10 0.88 UL, cUL 12 L5 IS
2 EB-332EBF-1-TP-PIC 120 0.56 67 > 0.98 < 10 0.88 UL, cUL 12 L5 IS
2 EB-332EBF-2-TP-PIC 277 0.25 67 > 0.98 < 10 0.88 UL, cUL 12 L5 IS
2 EB-332EBF-UV-TP-PIC 120~277 0.56~0.25 67 > 0.98 < 10 0.88 UL, cUL 12 L5 IS
2 EB-332HBF-1-TP-PIC 120 0.84 100 > 0.98 < 10 1.18 UL, cUL 12 L3 IS
2 EB-332HBF-2-TP-PIC 277 0.36 100 > 0.98 < 10 1.18 UL, cUL 12 L3 IS
2 EB-332HBF-UV-TP-PIC 120~277 0.84~0.36 100 > 0.98 < 10 1.18 UL, cUL 12 L3 IS
2 EPD-140T8M 120 0.67 80 > 0.99 < 10 0.90 UL, cUL 12 AA1 IS
2 EPT-332T8M 347 0.22 77 > 0.99 < 15 0.89 UL, cUL 12 AA1 IS
2 EPT-A32T8M 120~277 0.65~0.29 79 > 0.99 < 10 0.89 UL, cUL 12 AA1 IS
2 EB-432LBF-1-TP-PICws *** 120 0.40 108 > 0.98 < 10 0.88 UL, cUL 13 L5 IS
2 EB-432LBF-2-TP-PIC 277 0.90 108 > 0.98 < 10 0.88 UL, cUL 13 L5 IS
2 EB-432LBF-UV-TP-PICws 120~277 0.40~0.90 108 > 0.98 < 10 0.88 UL, cUL 13 L5 IS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
FLUORESCENT LAMPS
A22T8 Straight Lamps
ws This item is well stocked
* replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
** cap off one BLUE wire for one lamp application.
*** cap off one BLUE wire for three lamp application.
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Ele
ctr
onic
Balla
sts Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
40W F40T8
3 EB-432EBF-1-TP-PIC 120 0.82 98 > 0.98 < 10 0.85 UL, cUL 13 L5 IS
3 EB-432EBF-2-TP-PIC 277 0.36 98 > 0.98 < 10 0.85 UL, cUL 13 L5 IS
3 EB-432EBF-UV-TP-PIC 120~277 0.82~0.36 98 > 0.98 < 10 0.85 UL, cUL 13 L5 IS
3 EPQ-140T8M 120 0.89 107 > 0.99 < 10 0.87 UL, cUL 52 AA1 IS
3 EPQ-332T8M 347 0.31 107 > 0.99 < 10 0.87 UL, cUL 52 AA1 IS
3 EPQ-A32T8M 120~277 0.89~0.40 108 > 0.99 < 10/15 0.89 UL, cUL 52 AA1 IS
3 ESPQ-132T8HO 120 1.02 122 > 0.99 < 10 1.02 UL, cUL 57 A29 RS
3 ESPQ-332T8HO 347 0.36 125 > 0.99 < 10 0.90 UL, cUL 57 A29 RS
4 ESPQ-132T8HO 120 1.36 163 > 0.99 < 10 0.72 UL, cUL 42 A29 RS
4 ESPQ-332T8HO 347 0.48 166 > 0.99 < 10 0.74 UL, cUL 42 AA29 RS
59W F96T8
1 OR 2 EB-259-1-TP-PIC ** 120 0.95 112 > 0.99 < 10 0.88 UL, cUL 12 L3 IS
1 OR 2 EB-259-2-TP-PIC ** 277 0.41 112 > 0.98 < 10 0.88 UL, cUL 12 L3 IS
1 OR 2 EB-259-UV-TP-PIC ** 120~277 0.95~0.41 112 > 0.98 < 10 0.88 UL, cUL 12 L3 IS
1 EPD-159T8M 120 0.55 66 > 0.99 < 10 1.07 UL, cUL 31 AA1 IS
1 EPD-359T8M 347 0.19 66 > 0.99 < 10 1.05 UL, cUL 31 AA1 IS
1 EPD-A59T8M 120~277 0.55~0.25 67 > 0.99 < 10 1.09 UL, cUL 31 AA1 IS
2 EPD-159T8M 120 0.89 107 > 0.99 < 10 0.89 UL, cUL 12 AA1 IS
2 EPD-359T8M 347 0.32 110 > 0.99 < 10 0.92 UL, cUL 12 AA1 IS
2 EPD-A59T8M 120~277 0.89~0.39 107 > 0.99 < 10 0.89 UL, cUL 12 AA1 IS
86W F96T8
1 ESD-A86T8HO 120~277 0.92~0.4 110 > 0.99 < 10 1.12 UL, cUL 6 AA22 RS
1 EPD-359T8M 347 0.19 66 > 0.99 < 10 1.05 UL, cUL 31 AA1 IS
1 EPD-A59T8M 120~277 0.55~0.25 67 > 0.99 < 10 1.09 UL, cUL 31 AA1 IS
2 ESD-A86T8HO 120~277 1.56~0.67 110 > 0.99 < 10 1 UL, cUL 5 AA29 RS
2 ESD-A86T8HO 347 0.32 110 > 0.99 < 10 0.92 UL, cUL 12 AA1 IS
2 EPD-A59T8M 120~277 0.89~0.39 107 > 0.99 < 10 0.89 UL, cUL 12 AA1 IS
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
FLUORESCENT LAMPS
A23T12 Straight Lamps
ws This item is well stocked# add “EMI” for model with EMI filter, comply with FCC Class B.
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
14W F14T12
1 EB-120-1-TP 120 0.24 15 > 0.50 < 150 1.0 UL, cUL 28 X1 RS
1 EB-120-1-TP-EMI 120 0.24 15 > 0.50 < 150 1.0 UL, cUL 28 L7 RS
2 EB-220-1-TP # 120 0.42 27 > 0.50 < 150 0.85 UL, cUL 30 L7 RS
15W F15T12
1 EB-120-1-TP 120 0.26 17 > 0.50 < 150 1.0 UL, cUL 28 X1 RS
1 EB-120-1-TP-EMI 120 0.26 17 > 0.50 < 150 1.02 UL, cUL 28 L7 RS
2 EB-220-1-TP # 120 0.45 32 > 0.50 < 150 1.02 UL, cUL 30 L7 RS
20W F20T12
1 EB-120-1-TP 120 0.27 18 > 0.50 < 150 0.90 UL, cUL 28 X1 RS
1 EB-120-1-TP-EMI 120 0.27 18 > 0.50 < 150 0.90 UL, cUL 28 L7 RS
2 EB-220-1-TP # 120 0.52 36 > 0.50 < 150 0.87 UL, cUL 30 L7 RS
25W F40T12
1 EB-1382D-1-TP 120 0.60 40 > 0.50 < 150 0.95 UL, cUL 28 S1 RS
1 EB-1382D-1-TP-LC 120 0.60 40 > 0.50 < 150 0.95 UL, cUL 28 L2 RS
1 EB-140-1-TP # 120 0.53 36 > 0.50 < 150 0.88 UL, cUL 28 L7 RS
1 EB-240-UV-TP-PIC 120~277 0.43~0.19 51 > 0.99 < 10 1.70 UL, cUL 39 L5 RS
2 EB-240-1-TP 120 0.85 56 > 0.50 < 150 1.05 UL, cUL 30 L1 RS
2 EB-240-1-TP-PIC 120 0.66 78 > 0.99 < 10 1.40 UL, cUL 5 L5 RS
2 EB-240-UV-TP-PIC 120~277 0.66~0.28 78 > 0.99 < 10 1.40 UL, cUL 5 L5 RS
30W F30T12
2 EB-240-1-TP 120 0.73 47 0.55 < 150 0.85 UL, cUL 30 L1 RS
1 EB-240-1-TP-PIC 120~277 0.32 38 > 0.98 < 10 1.00 UL, cUL 39 L5 RS
2 EB-240-UV-TP-PIC 120~277 0.32~0.14 38 > 0.99 < 10 1.00 UL, cUL 5 L5 RS
1 EB-240-1-TP-PIC 120 0.49 58 > 0.99 < 10 0.88 UL, cUL 5 L5 RS
2 EB-240-UV-TP-PIC 120~277 0.49~0.22 58 > 0.99 < 10 0.88 UL, cUL 5 L5 RS
34WF40T12
Energy
Saver
1 EB-1382D-1-TP 120 0.59 39 > 0.50 < 150 1.00 UL, cUL 28 S1 RS
1 EB-1382D-1-TP-LC 120 0.59 39 > 0.50 < 150 1.00 UL, cUL 28 L2 RS
1 EB-140-1-TP # 120 0.45 30 > 0.50 < 150 0.88 UL, cUL 28 L7 RS
1 EB-240-UV-TP-PIC 120~277 0.34~0.15 40 > 0.98 < 10 1.10 UL, cUL 39 L5 RS
2 EB-240-1-TP 120 0.76 48 > 0.50 < 150 0.73 UL, cUL 30 L1 RS
2 EB-240-1-TP-PIC 120 0.53 63 > 0.99 < 10 0.85 UL, cUL 5 L5 RS
2 EB-240-UV-TP-PIC 120~277 0.53~0.23 63 > 0.98 < 10 0.85 UL, cUL 5 L5 RS
34W
F40T12
/U
Energy
Saver
1 EB-140-1-TP # 120 0.45 30 > 0.50 < 150 0.88 UL, cUL 28 L7 RS
1 EB-240-UV-TP-PIC 120~277 0.34~0.15 40 > 0.98 < 10 1.10 UL, cUL 39 L5 RS
2 EB-240-1-TP-PIC 120 0.53 63 > 0.98 < 10 0.85 UL, cUL 5 L5 RS
2 EB-240-UV-TP-PIC 120~277 0.53~0.23 63 > 0.98 < 10 0.85 UL, cUL 5 L5 RS
40W F40T12
1 EB-1382D-1-TP 120 0.60 40 > 0.50 < 150 0.95 UL, cUL 28 S! RS
1 EB-1382D-1-TP-LC 120 0.60 40 > 0.50 < 150 0.95 UL, cUL 28 L2 RS
1 EB-140-1-TP # 120 0.53 36 > 0.50 < 150 0.88 UL, cUL 28 L7 RS
1 EB-240-UV-TP-PIC 120~277 0.40~0.17 47 > 0.99 < 10 1.10 UL, cUL 5 L5 RS
2 EB-240-1-TP 120 0.87 58 > 0.50 < 150 0.75 UL, cUL 30 L1 RS
2 EB-240-1-TP-PIC 120 0.62 74 > 0.99 < 10 0.88 UL, cUL 5 L5 RS
2 EB-240-UV-TP-PIC 120~277 0.62~0.27 74 > 0.99 < 10 0.88 UL, cUL 5 L5 RS
40WF40T12
/U
1 EB-140-1-TP # 120 0.53 36 > 0.50 < 150 0.88 UL, cUL 28 L7 RS
1 EB-240-UV-TP-PIC 120~277 0.40~0.17 47 > 0.99 < 10 1.10 UL, cUL 39 L5 RS
2 EB-240-1-TP-PIC 120 0.62 74 > 0.99 < 10 0.88 UL, cUL 5 L5 RS
2 EB-240-UV-TP-PIC 120~277 0.62~0.27 74 > 0.99 < 10 0.88 UL, cUL 5 L5 RS
Ele
ctro
nic
Balla
sts
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
FLUORESCENT LAMPS
A24T12 Straight Lamps
* add “SL” for model L3 or AA1 Case style.
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
30WF48T12/
ES
2 EB-275-1-TP-PIC* 120 0.60 64 0.98 < 12 0.92 UL, cUL 12 D8 IS
2 EB-275-2-TP-PIC* 277 0.26 64 0.95 < 12 0.92 UL, cUL 12 D8 IS
2 EB-275-UV-TP-PIC* 120~277 0.60~0.26 64 0.95 < 12 0.92 UL, cUL 12 D8 IS
35W F42T12
2 EB-260-1-TP-PIC 120 0.55 66 0.98 < 12 1.00 UL, cUL 12 L5 IS
2 EB-260-2-TP-PIC 277 0.24 66 0.98 < 12 1.00 UL, cUL 12 L5 IS
2 EB-260-UV-TP-PIC 120~277 0.55~0.24 66 0.95 < 12 1.00 UL, cUL 12 L5 IS
40W F48T12
2 EB-260-1-TP-PIC 120 0.62 74 0.98 < 12 0.92 UL, cUL 12 L5 IS
2 EB-275-1-TP-PIC* 120 0.68 76 0.98 < 12 0.92 UL, cUL 12 D8 IS
2 EB-260-2-TP-PIC 277 0.27 74 0.98 < 12 0.92 UL, cUL 12 L5 IS
2 EB-275-2-TP-PIC* 277 0.30 76 0.95 < 12 0.92 UL, cUL 12 D8 IS
2 EB-260-UV-TP-PIC 120~277 0.62~0.27 74 0.95 < 12 0.92 UL, cUL 12 L5 IS
2 EB-275-UV-TP-PIC* 120~277 0.68~0.30 76 0.95 < 12 0.92 UL, cUL 12 D8 IS
57W F72T12
1 EB-275-1-TP-PIC* 120 0.60 67 0.98 < 12 1.05 UL, cUL 31 D8 IS
1 EB-275-2-TP-PIC* 277 0.26 67 0.95 < 12 1.05 UL, cUL 31 D8 IS
1 EB-275-UV-TP-PIC* 120~277 0.60~0.26 67 0.95 < 12 1.05 UL, cUL 31 D8 IS
2 EB-260-1-TP-PIC 120 0.90 106 0.98 < 12 0.95 UL, cUL 12 L5 IS
2 EB-275-1-TP-PIC* 120 0.92 107 0.98 < 12 0.95 UL, cUL 12 D8 IS
2 EB-260-2-TP-PIC 277 0.39 106 0.98 < 12 0.95 UL, cUL 12 L5 IS
2 EB-275-2-TP-PIC* 277 0.40 107 0.95 < 12 0.95 UL, cUL 12 D8 IS
2 EB-260-UV-TP-PIC 120~277 0.92~0.39 106 0.95 < 12 0.95 UL, cUL 12 L5 IS
2 EB-275-UV-TP-PIC* 120~277 0.92~0.40 107 0.95 < 12 0.95 UL, cUL 12 D8 IS
60WF96T12/
ES
1 EB-275-1-TP-PIC* 120 0.60 71 > 0.98 < 12 1.12 UL, cUL 31 D8 IS
1 EB-275-2-TP-PIC* 277 0.27 72 > 0.98 < 12 1.12 UL, cUL 31 D8 IS
1 EB-275-UV-TP-PIC* 120~277 0.27~0.60 72 > 0.98 < 12 1.12 UL, cUL 31 D8 IS
2 EB-260-1-TP-PIC 120 0.97 115 > 0.98 < 12 0.95 UL, cUL 12 L5 IS
2 EB-275-1-TP-PIC* 120 0.97 115 > 0.98 < 12 0.95 UL, cUL 12 D8 IS
2 EB-260-2-TP-PIC 277 0.42 115 > 0.98 < 12 0.95 UL, cUL 12 L5 IS
2 EB-275-2-TP-PIC 277 0.42 115 > 0.98 < 12 0.95 UL, cUL 12 D8 IS
2 EB-260-UV-TP-PIC 120~277 0.97~0.42 115 0.95 < 12 0.95 UL, cUL 12 L5 IS
2 EB-275-UV-TP-PIC* 120~277 0.97~0.42 115 > 0.98 < 12 0.95 UL, cUL 12 D8 IS
75W F96T12
1 EB-275-1-TP-PIC* 120 0.69 83 > 0.98 < 12 1.05 UL, cUL 31 D8 IS
1 EB-275-2-TP-PIC* 277 0.31 83 > 0.98 < 12 1.05 UL, cUL 31 D8 IS
1 EB-275-UV-TP-PIC* 120~277 031~0.69 83 > 0.98 < 12 1.05 UL, cUL 31 D8 IS
2 EB-275-1-TP-PIC* 120 1.15 133 > 0.98 < 12 0.86 UL, cUL 12 D8 IS
2 EB-275-2-TP-PIC* 277 0.50 136 > 0.98 < 12 0.86 UL, cUL 12 D8 IS
2 EB-275-UV-TP-PIC* 120~277 0.49~1.15 133 > 0.98 < 12 0.86 UL, cUL 12 D8 IS
Ele
ctr
onic
Balla
sts
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
HIGH OUTPUT LAMPS
A25T12 Straight Lamps
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
60W F48T12/HO
2 EB-2110-1-TP-PIC 120 0.88 104 > 0.98 < 10 0.90 UL, cUL 5 AA1 RS
2 EB-2110-2-TP-PIC 277 0.38 104 > 0.98 < 10 0.90 UL, cUL 5 AA1 RS
2 EB-2110-UV-TP-PIC 120~277 0.88~0.38 104 > 0.95 < 20 0.90 UL, cUL 5 AA1 RS
75W F60T12/HO
2 EB-2110-1-TP-PIC 120 1.10 132 > 0.98 < 10 0.90 UL, cUL 5 AA1 RS
2 EB-2110-2-TP-PIC 277 0.48 132 > 0.98 < 10 0.90 UL, cUL 5 AA1 RS
2 EB-2110-UV-TP-PIC 120~277 1.10~0.48 132 > 0.95 < 20 0.90 UL, cUL 5 AA1 RS
85W F72T12/HO
2 EB-2110-1-TP-PIC 120 1.30 154 > 0.98 < 10 0.90 UL, cUL 5 AA1 RS
2 EB-2110-2-TP-PIC 277 0.56 154 > 0.98 < 10 0.90 UL, cUL 5 AA1 RS
2 EB-2110-UV-TP-PIC 120~277 1.30~0.56 154 > 0.95 < 10 0.90 UL, cUL 5 AA1 RS
95WF96T12/HO/
ES
2 EB-2110-1-TP-PIC 120 1.38 164 > 0.98 < 10 0.90 UL, cUL 5 AA1 RS
2 EB-2110-2-TP-PIC 277 0.60 164 > 0.98 < 10 0.90 UL, cUL 5 AA1 RS
2 EB-2110-UV-TP-PIC 120~277 1.38~0.60 164 > 0.95 < 20 0.90 UL, cUL 5 AA1 RS
110W F96T12/HO
1 EB-260-1-TP-PIC 120 0.90 108 > 0.98 < 12 1.00 UL, cUL 31 L5 IS
1 EB-260-2-TP-PIC 277 0.39 106 > 0.98 < 12 1.00 UL, cUL 31 L5 IS
1 EB-260-UV-TP-PIC 120~277 0.90~0.39 108 > 0.95 < 20 1.00 UL, cUL 31 L5 IS
1 EB-2110-1-TP-PIC 120 0.88 104 > 0.98 < 10 0.92 UL, cUL 39 AA1 RS
1 EB-2110-2-TP-PIC 277 0.38 104 > 0.98 < 10 0.92 UL, cUL 39 AA1 RS
1 EB-2110-UV-TP-PIC 120~277 0.88~0.38 104 > 0.95 < 20 0.92 UL, cUL 39 AA1 RS
2 EB-2110-1-TP-PIC 120 1.65 196 > 0.98 < 10 0.90 UL, cUL 5 AA1 RS
2 EB-2110-2-TP-PIC 277 0.72 196 > 0.98 < 10 0.90 UL, cUL 5 AA1 RS
2 EB-2110-UV-TP-PIC 120~277 1.65~0.72 196 > 0.95 < 20 0.90 UL, cUL 5 AA1 RS
Ele
ctro
nic
Balla
sts
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
COMPACT FLUORESCENT LAMPS
A26T5 Compact Lamps
ws This item is well stocked
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
7W CFT7W/2G7 1 EB-108-1-TP-FC 120 0.12 7.5 > 0.50 < 150 1.05 UL, cUL 26 V1 RS
9W CFT9W/2G7 1 EB-108-1-TP-FC 120 0.13 8.5 > 0.50 < 150 1.0 UL, cUL 26 V1 RS
13WCFQ13W/
G24q
1 EB-113-1-TP 120 0.22 14 > 0.50 < 150 0.90 UL, cUL 26 C6 RS
1 EB-113-1-TP-MC 120 0.22 14 > 0.50 < 150 0.90 UL, cUL 26 J1 RS
1 EB-113-1-TP-SL 120 0.22 14 > 0.50 < 150 0.90 UL, cUL 26 N2 RS
1 EB-113-1-TP-SL-MC 120 0.22 14 > 0.50 < 150 0.90 UL, cUL 26 P2 RS
1 EB-113-1-TP-SLLws 120 0.22 14 > 0.50 < 150 0.90 UL, cUL 26 N1 RS
1 EB-113-1-TP-SLL-MCws 120 0.22 14 > 0.50 < 150 0.90 UL, cUL 26 P1 RS
1 EB-113-1-TP-PN 120 0.22 14 > 0.50 < 150 0.90 UL, cUL 26 S1 RS
1 EB-113-1-TP-SC # 120 0.22 14 > 0.50 < 150 0.90 UL, cUL 26 L8 RS
1 EB-114-1-TP-FC 120 0.22 14 > 0.50 < 150 0.90 UL, cUL 26 V1 RS
1 EB-213-UV-TP-PIC-DWws* 120~277 0.15~0.07 18 > 0.96 < 10 1.1 UL, cUL 35 W1 RS
1 EB-213-UV-TP-PSD* 120~277 0.14~0.065 17 > 0.95 < 12 1.05 UL, cUL 35 W1 PS
2 CSD-UV-18Pws 120~277 0.29~0.13 35 > 0.98 < 10/15 1.3 UL, cUL 33 AA15 PS
2 CSD-UV-18PBM 120~277 0.29~0.14 35 > 0.98 < 10/15 1.3 UL, cUL 33 AA16 PS
2 EB-213-1-TP 120 0.43 28 > 0.50 < 150 0.95 UL, cUL 29 C6 RS
2 EB-213-1-TP-MCws 120 0.43 28 > 0.50 < 150 0.95 UL, cUL 29 J1 RS
2 EB-213-1-TP-SLws 120 0.43 28 > 0.50 < 150 0.95 UL, cUL 29 N1 RS
2 EB-213-1-TP-SL-MCws 120 0.43 28 > 0.50 < 150 0.95 UL, cUL 29 P1 RS
2 EB-213-UV-TP-PSD* 120~277 0.26~0.12 30 > 0.98 < 10 1.0 UL, cUL 33 W1 PS
2 EB-213-UV-TP-PIC-DWws* 120~277 0.27~0.12 32 > 0.99 < 10 1.05 UL, cUL 33 W1 RS
2 EB-213-UV-TP-PICws * 120~277 0.27~0.12 32 > 0.99 < 10 1.05 UL, cUL 33 T1 RS
2 EB-213-1-TP-SC # 120 0.43 28 > 0.50 < 150 0.95 UL, cUL 29 L8 RS
2 EB-213-1-TP-DW * 120 0.43 28 > 0.50 < 150 0.95 UL, cUL 33 W1 RS
13W
CFTR13
W/
GX24q
1 CSD-UV-18Pws 120~277 0.18~0.07 19 > 0.96 < 17 1.47 UL, cUL 35 AA15 PS
1 CSD-UV18PBMws 120~277 0.18~0.07 19 > 0.96 < 17 1.47 UL, cUL 35 AA16 PS
1 FSD-A18PBM 120~277 0.14~0.07 18 > 0.97 < 10/20 0.95 UL, cUL 35 AA23 PS
1 GSD-A18PBM 120~277 0.14~0.07 18 > 0.98 < 10/20 0.95 UL, cUL 35 AA24 PS
1 EB-213-UV-TP-PSD* 120~277 0.14~0.065 17 > 0.95 < 12 1.05 UL, cUL 35 W1 PS
1 EB-213-UV-TP-PIC-DWws * 120~277 0.15~0.07 18 > 0.96 < 10 1.1 UL, cUL 35 W1 RS
2 CSD-B18P 277~347 0.13~0.1 35 > 0.99 < 15 1.31 UL, cUL 33 AA15 PS
2 CSD-UV-18Pws 120~277 0.28~0.13 35 > 0.98 < 10/15 1.3 UL, cUL 33 AA15 PS
2 CSD-UV18PBMws 120~277 0.28~0.13 35 > 0.98 < 10/15 1.3 UL, cUL 33 AA16 PS
2 EB-213-UV-TP-PIC-DWws * 120~277 0.27~0.07 32 > 0.99 < 10 1.05 UL, cUL 33 W1 RS
2 FSD-A18PBMws 120~277 0.27~0.12 33 > 0.98 < 10 0.91 UL, cUL 33 AA23 PS
2 GSD-A18PBMws 120~277 0.27~0.12 33 > 0.98 < 10 0.98 UL, cUL 33 AA24 PS
2 EB-213-UV-TP-PIC-DW * 120~277 0.27~0.12 32 > 0.99 < 10 1.05 UL, cUL 33 W1 RS
2 EB-213-1-TP-SC # 120 0.43 28 > 0.50 < 150 0.95 UL, cUL 29 L8 RS
2 EB-213-1-TP-DW * 120 0.43 28 > 0.50 < 150 0.95 UL, cUL 33 W1 RS
13WCFT13W/
2GX7
1 EB-113FT-1-TP-PN 120 0.20 13 > 0.50 < 150 0.95 UL, cUL 26 S1 RS
1 EB-113FT-1-TP-SC # 120 0.20 13 > 0.50 < 150 0.95 UL, cUL 26 L8 RS
* Ballast with bottom out connectors and with studs, Add “/NS” for case with bottom out connectors and without studs, Add “/LS” for
case with lead wire out and with studs, Add “/NL” for case with lead wire out and without studs
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Ele
ctr
onic
Balla
sts
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
COMPACT FLUORESCENT LAMPS
A27T5 Compact Lamps
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
18WCFQ18
W/G24q
1 EB-1C22-1-TP 120 0.33 20 > 0.50 < 150 1.0 UL, cUL 26 S1 RS
1 EB-1C22-1-TP-LC 120 0.33 20 > 0.50 < 150 1.0 UL, cUL 26 L1 RS
1 EB-1C22-1-TP-SC # 120 0.33 20 > 0.50 < 150 1.0 UL, cUL 26 L8 RS
1 EB-118-1-TP-SC # 120 0.28 18 > 0.50 < 150 1.0 UL, cUL 26 L8 RS
1 EB-213-UV-TP-PICws * 120~277 0.21~0.0085 23 > 0.98 < 12 1.2 UL, cUL 35 T1 RS
1 EB-218-UV-TP-PIC-DWws* 120~277 0.21~0.10 24 > 0.95 < 12 1.2 UL, cUL 35 W1 RS
2 EB-218-UV-TP-PICws* 120~277 0.36~0.16 40 > 0.99 < 10 1.1 UL, cUL 33 T1 RS
2 EB-218-UV-TP-PIC-DWws* 120~277 0.36~0.16 40 > 0.99 < 10 1.1 UL, cUL 33 W1 RS
2 EB-218-1-TP 120 0.59 36 > 0.50 < 150 1.0 UL, cUL 29 C6 RS
2 EB-218-1-TP-SC # 120 0.59 36 > 0.50 < 150 1.0 UL, cUL 29 L8 RS
2 EB-218-1-TP-DW * 120 0.59 36 > 0.50 < 150 1.0 UL, cUL 33 W1 RS
18W
CFTR18
W/
GX24q
1 EB-218-UV-TP-PIC-DWws 120~277 0.21~0.10 24 > 0.95 < 12 1.2 UL, cUL 35 W1 RS
2 EB-218-UV-TP-PIC-DWws 120~277 0.36~0.16 42 > 0.99 < 10 1.1 UL, cUL 33 W1 RS
2 EB-218-1-TP-SC # 120 0.59 36 > 0.50 < 150 1.0 UL, cUL 29 L8 RS
2 EB-218-1-TP-DW * 120 0.59 36 > 0.50 < 150 1.0 UL, cUL 33 W1 RS
18W
CFTR18
W/
GX24q
1 CSD-B18P 277~347 0.08~0.06 22 > 0.98 < 15 1.1 UL, cUL 35 AA15 PS
1 CSD-UV-18P 120~277 0.18~0.08 22 > 0.98 < 15 1.27 UL, cUL 35 AA15 PS
1 CSD-UV-18PBM 120~277 0.17~0.08 22 > 0.98 < 15 1.1 UL, cUL 35 AA16 PS
1 EB-218-UV-TP-PSD* 120~277 0.17~0.08 20 > 0.95 < 12 1.0 UL, cUL 35 W1 PS
1 FSD-A18PBMws 120~277 0.17~0.08 21 > 0.97 < 10/15 0.92 UL, cUL 35 AA23 PS
1 GSD-A18PBM 120~277 0.17~0.08 21 > 0.98 < 10/15 0.92 UL, cUL 35 AA24 PS
2 CSD-UV-18Pws 120~277 0.34~0.15 41 > 0.99 < 10/15 1.08 UL, cUL 33 AA15 PS
2 CSD-B18P 120~277 0.14~0.11 40 > 0.99 < 10 1.1 UL, cUL 33 AA15 PS
2 CSD-UV18PBM 120~277 0.34~0.15 41 > 0.98 < 10/15 1.13 UL, cUL 33 AA16 PS
2 EB-218-UV-TP-PSD* 120~277 0.30~0.13 36 > 0.98 < 10 0.95 UL, cUL 33 W1 PS
2 FSD-A18PBMws 120~277 0.32~0.15 39 > 0.98 < 10/15 0.85 UL, cUL 33 AA23 PS
2 GSD-A18PBMws 120~277 0.32~0.15 39 > 0.98 < 10/15 0.92 UL, cUL 33 AA24 PS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ws This item is well stocked
* Ballast with bottom out connectors and with studs, Add “/NS” for case with bottom out connectors and without studs, Add “/LS” for case with lead wire out and with
studs, Add “/NL” for case with lead wire out and without studs.
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs
Ele
ctro
nic
Balla
sts
ElectronicBallast
Ele
ctr
onic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A28
ELECTRONIC BALLAST FOR
COMPACT FLUORESCENT LAMPS
T5 Compact Lamps
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
26WCFQ26
W/G24q
1 CSD-UV32P/BM 120-277 0.29-0.13 36 > 0.95 < 10/40 1 UL, cUL 35 AA18 PS
1 CSD-UV32PXS 120-277 0.29-0.13 36 > 0.95 < 10/40 1 UL, cUL 35 AA5 PS
1 CSD-UV42P 120-277 0.3-0.13 36 > 0.98 < 20/50 0.99 UL, cUL 35 AA19 PS
1 CSD-UV42P/BM 120-277 0.24-0.13 30 > 0.97 < 30/60 1 UL, cUL 35 AA21 PS
1 EB-126-1-TP 120 0.40 24 > 0.50 < 150 0.90 UL, cUL 26 S1 RS
1 EB-126-1-TP-SC # 120 0.40 24 > 0.50 < 150 0.90 UL, cUL 26 L8 RS
1 EB-142T-1-TP-SC # 120 0.43 28 > 0.50 < 150 1.05 UL, cUL 26 L8 RS
1 EB-218-UV-TP-PICws * 120-277 0.26~0.11 30 > 0.98 < 10 1.05 UL, cUL 35 T1 RS
1 EB-226-UV-TP-PIC-DWws* 120-277 0.27~0.12 33 > 0.96 < 12 1.2 UL, cUL 35 W1 RS
1 EB-226-UV-TP-PSD* 120-277 0.23~0.10 27 > 0.95 < 10 0.95 UL, cUL 35 W1 PS
1 EB-242T-UV-TP-PSD* 120-277 0.27~0.13 32 > 0.95 < 10 1.0 UL, cUL 35 W2 PS
1 EB-242T-UV-TP-PIC-DW * 120-277 0.27~0.13 32 > 0.95 < 10 1.0 UL, cUL 35 W2 RS
1 FSD-A32PBMws 120-277 0.19-0.09 23 > 0.98 < 10/15 0.74 UL, cUL 35 AA23 PS
1 GSD-A18PBMws 120-277 0.19-0.09 23 > 0.98 < 10/15 0.74 UL, cUL 35 AA24 PS
2 CSD-B42PBM 277-347 0.22-0.18 60 > 0.98 < 15 1 UL, cUL 33 AA20 PS
2 CSD-B42PS 277-347 0.32-0.18 60 > 0.98 < 10/15 0.90 UL, cUL 33 AA19 P
2 CSD-UV32P/BM 120-277 0.49-0.21 59 > 0.99 < 10 1 UL, cUL 33 AA18 PS
2 CSD-UV32PXS 120-277 0.49-0.21 59 > 0.99 < 10 1 UL, cUL 33 AA15 PS
2 CSD-UV42P 120-277 0.46-0.21 56 > 0.98 < 10/20 1.07 UL, cUL 33 AA19 PS
2 CSD-UV42PBM 120-277 0.46~0.21 56 > 0.98 < 10/20 1.07 UL, cUL 33 AA20 PS
2 EB-226-1-TPws 120 0.80 51 > 0.50 < 150 1.0 UL, cUL 29 C6 RS
2 EB-226-1-TP-SC # 120 0.80 51 > 0.50 < 150 1.0 UL, cUL 29 L8 RS
2 EB-226-1-TP-DW * 120 0.80 51 > 0.50 < 150 1.0 UL, cUL 33 W1 RS
2 EB-226-UV-TP-PSD* 120-277 0.42~0.18 51 > 0.98 < 10 0.95 UL, cUL 33 W1 PS
2 EB-226-UV-TP-PIC * 120-277 0.49~0.21 58 > 0.99 < 10 1.0 UL, cUL 33 T1 RS
2 EB-226-UV-TP-PIC-DWws* 120-277 0.49~0.21 58 > 0.99 < 10 1.0 UL, cUL 33 W1 RS
2 EB-240-1-TP 120 0.69 43 > 0.50 < 150 0.85 UL, cUL 29 L1 RS
2 EB-242T-UV-TP-PICws* 120-277 0.50~0.22 60 > 0.97 < 10 1.05 UL, cUL 33 T2 RS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
* Ballast with bottom out connectors and with studs, Add “/NS” for case with bottom out connectors and without studs, Add “/LS” for case with lead wire out and with
studs, Add “/NL” for case with lead wire out and without studs.
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs
ws This item is well stocked
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A29
ELECTRONIC BALLAST FOR
COMPACT FLUORESCENT LAMPS
T5 Compact Lamps
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
* Ballast with bottom out connectors and with studs, Add “/NS” for case with bottom out connectors and without studs, Add “/LS” for case with lead wire out and with
studs, Add “/NL” for case with lead wire out and without studs.
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs
ws This item is well stocked
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
26WCFQ26W/
G24q
2 EB-242T-UV-TP-PIC-DWws* 120~277 0.45~0.21 54 > 0.97 < 10 0.90 UL, cUL 33 W2 RS
2 EB-242T-UV-TP-PSD* 120~277 0.45~0.21 54 > 0.97 < 10 0.90 UL, cUL 33 W2 PS
2 FSD-A32PBMws 120~277 0.5-0.22 59 > 0.98 < 10/20 0.93 UL, cUL 33 AA23 PS
2 GSD-A32PBM 120~277 0.5-0.22 59 > 0.98 < 10/20 0.93 UL, cUL 35 AA24 PS
26WCFTR26
W/G24Xq
1 EB-142T-1-TP-SC # 120 0.40 26 > 0.50 < 50 1.0 UL, cUL 26 L8 RS
1 EB-226-UV-TP-PSD* 120~277 0.20~0.09 24 > 0.95 < 10 0.90 UL, cUL 35 W1 PS
1 EB-226-UV-TP-PIC-DWws* 120~277 0.26~0.11 30 > 0.96 < 12 1.05 UL, cUL 35 W1 RS
1 EB-242T-UV-TP-PIC-DW * 120~277 0.27~0.13 32 > 0.95 < 10 1.0 UL, cUL 35 W2 RS
1 EB-242T-UV-TP-PSD* 120~277 0.27~0.13 32 > 0.95 < 10 1.0 UL, cUL 35 W2 PS
2 EB-226-UV-TP-PIC-DWws* 120~277 0.46~0.20 54 > 0.98 < 10 0.95 UL, cUL 33 W1 RS
2 EB-242T-UV-TP-PICws * 120~277 0.48~0.21 56 > 0.97 < 10 1.0 UL, cUL 33 T2 RS
2 EB-226-1-TP-SC # 120 0.80 51 > 0.50 < 150 1.0 UL, cUL 29 L8 RS
2 EB-226-1-TP-DW * 120 0.80 51 > 0.50 < 150 1.0 UL, cUL 33 W1 RS
2 EB-226-UV-TP-PSD* 120~277 0.40~0.18 48 > 0.98 < 10 0.90 UL, cUL 33 W1 PS
2 EB-242T-UV-TP-PIC-DW * 120~277 0.45~0.21 54 > 0.97 < 10 0.90 UL, cUL 33 W2 RS
2 EB-242T-UV-TP-PSD* 120~277 0.45~0.21 54 > 0.97 < 10 0.90 UL, cUL 33 W2 PS
32WCFTR32
W/GX24q
1 CSD-UV32P/BM 120~277 0.33~0.15 36 > 0.98 < 10/20 0.94 UL, cUL 35 AA18 PS
1 CSD-UV32PXS 120~277 0.33~0.15 36 > 0.98 < 10/20 0.93 UL, cUL 35 AA15 PS
1 CSD-UV42P 120~277 0.30~0.13 35 > 0.98 < 20/50 0.99 UL, cUL 35 AA19 PS
1 CSD-UV42P/BM 120~277 0.30~0.13 35 > 0.98 < 20/25 0.88 UL, cUL 35 AA21 PS
1 CSD-UV42PBM 120~277 0.30~0.13 35 > 0.98 < 20/50 0.99 UL, cUL 35 AA20 PS
1 EB-142T-1-TP-SC# 120 0.50 33 > 0.50 < 130 0.95 UL, cUL 26 L8 RS
1 EB-226-UV-TP-PICws* 120~277 0.35~0.15 41 > 0.98 < 10 1.1 UL, cUL 35 T1 RS
1 EB-226-UV-TP-PIC-DWws* 120~277 0.35~0.15 41 > 0.98 < 10 1.1 UL, cUL 35 W1 RS
1 EB-226-UV-TP-PSD* 120~277 0.30~0.13 36 > 0.98 < 10 1.0 UL, cUL 35 W1 PS
1 EB-242T-UV-TP-PIC-DW* 120~277 0.35~0.13 42 > 0.96 < 10 0.96 UL, cUL 35 W2 RS
1 EB-242T-UV-TP-PSD* 120~277 0.35~0.13 42 > 0.96 < 10 0.96 UL, cUL 35 W2 PS
2 EB-240-1-TP 120 0.91 61 > 0.50 < 150 0.89 UL, cUL 30 L1 RS
2 EB-232T-UV-TP-PIC* 120~277 0.55~0.24 65 > 0.98 < 10 0.95 UL, cUL 33 T2 RS
2 EB-242T-UV-TP-PICws* 120~277 0.62~0.27 74 > 0.97 < 10 1.0 UL, cUL 33 T2 RS
2 EB-242T-UV-TP-PIC-DW* 120~277 0.56~0.23 69 > 0.96 < 10 0.90 UL, cUL 33 W2 RS
ElectronicBallast
Ele
ctr
onic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A30T5 Compact Lamps
ELECTRONIC BALLAST FOR
COMPACT FLUORESCENT LAMPS
* Ballast with bottom out connectors and with studs, Add “/NS” for case with bottom out connectors and without studs, Add “/LS” for case with lead wire out and with studs,
Add “/NL” for case with lead wire out and without
studs.
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs
ws This item is well stocked
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
32WCFTR32
W/GX24q
1 FSD-A32PBMws 120~277 0.29~0.13 34 > 0.97 < 10/30 0.88 UL, cUL 35 AA23 PS
1 FSD-B32PBMws 277~347 0.13~0.11 35 > 0.98 < 15 0.88 UL, cUL 35 AA23 PS
1 GSD-A32PBM 120~277 0.29~0.13 34 > 0.97 < 10/30 0.88 UL, cUL 35 AA24 PS
42WCFTR42
W/GX24q
1 CSD-UV32P/BM 120~277 0.37~0.17 46 > 0.99 < 10/15 0.89 UL, cUL 35 AA18 PS
1 CSD-UV32PXS 120~277 0.37~0.17 46 > 0.99 < 10/15 0.89 UL, cUL 35 AA15 PS
1 CSD-UV42P 120~277 0.38~0.18 46 > 0.98 < 15/30 0.99 UL, cUL 35 AA19 PS
1 CSD-UV42P/BM 120~277 0.38~0.18 46 > 0.98 < 15/30 0.99 UL, cUL 35 AA21 PS
1 CSD-UV42PBM 120~277 0.36~0.17 43 > 0.98 < 20/35 0.91 UL, cUL 35 AA20 PS
1 EB-142T-1-TP-SC # 120 0.54 37 > 0.50 < 120 0.80 UL, cUL 26 L8 RS
1 EB-226-UV-TP-PSD* 120~277 0.38~0.16 45 > 0.98 < 10 1.0 UL, cUL 35 W1 PS
1 EB-226-UV-TP-PICws * 120~277 0.45~0.19 53 > 0.98 < 10 1.1 UL, cUL 35 T1 RS
1 EB-226-UV-TP-PIC-DWws* 120~277 0.45~0.19 53 > 0.98 < 10 1.1 UL, cUL 35 W1 RS
1 EB-242T-UV-TP-PIC-DW* 120~277 0.38~0.18 47 > 0.96 < 10 0.96 UL, cUL 35 W2 RS
1 EB-242T-UV-TP-PSD* 120~277 0.38~0.18 47 > 0.96 < 10 0.96 UL, cUL 35 W2 PS
1 FSD-A32PBMws 120~277 0.39~0.18 46 > 0.98 < 10/20 0.88 UL, cUL 35 AA23 PS
1 FSD-B32PBMws 277~347 0.17~0.14 47 > 0.99 < 10 0.93 UL, cUL 35 AA23 PS
1 GSD-A32PBM 120~277 0.39~0.18 46 > 0.98 < 10/20 0.88 UL, cUL 35 AA24 PS
2 CSD-B42PBM 277~347 0.34~0.27 95 > 0.98 < 10 0.91 UL, cUL 33 AA20 PS
2 CSD-B42PS ws 277~347 0.34~0.27 95 > 0.98 < 10 0.91 UL, cUL 33 AA19 PS
2 CSD-UV42P 120~277 0.74~0.32 88 > 0.99 < 10/20 0.92 UL, cUL 33 AA19 PS
2 CSD-UV42P/BM 120~277 0.74~0.32 88 > 0.99 < 10/20 0.92 UL, cUL 33 AA21 PS
2 CSD-UV42PBM 120~277 0.74~0.32 88 > 0.99 < 10/20 0.92 UL, cUL 33 AA20 PS
2 EB-242T-UV-TP-PICws * 120~277 0.74~0.31 88 > 0.98 < 10 1.0 UL, cUL 33 T2 RS
2 EB-242T-UV-TP-PIC-DW * 120~277 0.70~0.30 84 > 0.98 < 10 0.90 UL, cUL 33 W2 RS
2 EB-242T-UV-TP-PSD* 120~277 0.70~0.30 84 > 0.98 < 10 0.90 UL, cUL 33 W2 PS
2 ESPQ-A42PS-S 120~277 0.74~0.32 88 > 0.99 < 10 0.90 UL, cUL 33 AA22 PS
2 FSD-B32PBMws 277~347 0.26~0.20 69 > 0.99 < 10 0.85 UL, cUL 33 AA23 PS
4 ESPQ-A42PS-S 120~277 1.32~0.60 163 > 0.99 < 10 0.90 UL, cUL 33 AA22 PS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A31T5 Compact Lamps
ELECTRONIC BALLAST FOR
COMPACT FLUORESCENT LAMPS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
* Ballast with bottom out connectors and with studs, Add “/NS” for case with bottom out connectors and without studs, Add “/LS” for case with lead wire out and with
studs, Add “/NL” for case with lead wire out and without
studs.
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs
ws This item is well stocked
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
57WCFTR57W
/GX24q
1 CSD-B57PSHO 277~347 0.25~0.20 67 > 0.98 < 10 1.05 UL, cUL 35 AA26 PS
1 CSD-UV57P 120~277 0.48~0.22 58 > 0.98 < 10/25 0.84 UL, cUL 35 AA19 PS
1 CSD-UV57PBMS 120~277 0.46~0.21 58 > 0.98 < 10/20 0.85 UL, cUL 35 AA20 PS
1 CSD-UV57PS ws 120~277 0.46~0.21 57 > 0.98 < 10/20 0.86 UL, cUL 35 AA19 PS
1 EB-242T-UV-TP-PIC-DW * 120~277 0.42~0.19 50 > 0.97 < 10 0.80 UL, cUL 33 W2 RS
2 CSD-B57PSHO 277~347 0.5~0.40 136 > 0.98 < 10 0.98 UL, cUL 33 AA26 PS
2 CSD-B70PS 277~347 0.41~0.33 112 > 0.99 < 10 0.90 UL, cUL 33 AA26 PS
2 CSD-UV57P 120~277 0.95~0.4 112 > 0.98 < 10/15 0.84 UL, cUL 33 AA19 PS
2 CSD-UV57PBMS 120~277 0.92~0.41 111 > 0.98 < 10/15 0.79 UL, cUL 33 AA20 PS
2 CSD-UV57PSws 120~277 0.92~0.41 111 > 0.98 < 10/15 0.79 UL, cUL 33 AA19 PS
2 CSD-UV70PBMS 120~277 0.99~0.43 119 > 0.99 < 10 0.93 UL, cUL 33 AA25 PS
2 CSD-UV70PSws 120~277 0.99~0.43 119 > 0.99 < 10 0.93 UL, cUL 33 AA26 PS
4 ESPQ-A42PS-S 120~277 1.32~0.60 163 > 0.99 < 10 0.90 UL, cUL 33 AA22 PS
ElectronicBallast
Ele
ctr
onic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
COMPACT FLUORESCENT LAMPS
A32T5 Compact Lamps
ws This item is well stocked
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
70W CFTR70WGXq
1 CSD-B70PS 277~347 0.28~0.22 77 > 0.99 < 10/15 0.99 UL, cUL 35 AA26 PS
1 CSD-UV57PBMS 120~277 0.52~0.23 63 > 0.98 < 10/20 0.79 UL, cUL 35 AA20 PS
1 CSD-UV57PSws 120~277 0.52~0.23 63 > 0.98 < 10/20 0.79 UL, cUL 35 AA19 PS
1 CSD-UV70PBMS 120~277 0.62~0.27 74 > 0.98 < 10/15 0.99 UL, cUL 35 AA25 PS
1 CSD-UV70PS 120~277 0.62~0.27 74 > 0.98 < 10/15 0.99 UL, cUL 35 AA26 PS
1 TSD-UV70P 120~277 0.63~0.27 74 > 0.99 < 10 0.95 UL, cUL 35 AA27 PS
2 CSD-B70PSws 277~347 0.55~0.44 150 > 0.99 < 10 0.95 UL, cUL 33 AA26 PS
2 CSD-UV70PBMS 120~277 1.2~0.52 145 > 0.99 < 10 0.92 UL, cUL 33 AA25 PS
2 CSD-UV70PSws 120~277 1.2~0.52 145 > 0.99 < 10 0.92 UL, cUL 33 AA26 PS
2 TSD-UV70P 120~277 1.2~0.52 144 > 0.99 < 10 0.87 UL, cUL 33 AA27 PS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
LONG TWIN LAMPS 2G11 BASE
A33Long Twin Tube
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
ws This item is well stocked
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
24WFT24W
/2G11
1 EB-139HO-1-TP 120 0.43 28 > 0.50 < 150 1.00 UL, cUL 26 N1 RS
1 EB-224HO-UV-TP-PS 120~277 0.10~0.22 26 > 0.95 < 12 0.95 UL, cUL 37 U4 PS
1 EPSD-A40PBXM 120~277 0.23~0.11 27 > 0.97 < 10/30 0.90 UL, cUL 58 AA1 IS
1 EPD-340BXM 347 0.06 27 > 0.97 < 15 0.90 UL, cUL 58 AA1 IS
2 EB-224HO-UV-TP-PS 120~277 0.18~0.42 50 > 0.98 < 12 0.90 UL, cUL 36 U4 PS
2 EB-226-UV-TP-PSD 120~277 0.38~0.17 46 > 0.98 < 10 0.87 UL, cUL 33 W1 PS
2 EB-242T-UV-TP-PSD 120~277 0.45~0.20 54 > 0.98 < 10 1.00 UL, cUL 33 W2 PS
2 EB-242T-UV-TP-PIC-DW 120~277 0.45~0.20 54 > 0.98 < 10 1.00 UL, cUL 33 W2 RS
2 EPD-340BXM 347 0.13 44 > 0.98 < 15 0.82 UL, cUL 59 AA1 IS
2 EPSD-A40PBXM 120~277 0.37~0.17 44 > 0.99 < 10/15 0.82 UL, cUL 59 AA1 IS
2 FSD-A32PBMws 120~277 0.45~0.21 54 > 0.97 < 10/20 0.88 UL, cUL 33 AA23 PS
2 FSD-B32PBMws 277~347 0.20~0.16 54 > 0.99 < 10 0.88 UL, cUL 33 AA23 PS
2 GSD-A32PBM 120~277 0.45~0.21 54 > 0.97 < 10/20 0.88 UL, cUL 33 AA24 PS
36WFT36W
/2G11
1 CSD-UV42P 120~277 0.28~0.13 34 > 0.95 < 25/45 0.89 UL, cUL 35 AA19 PS
1 CSD-UV42P/BM 120~277 0.28~0.13 34 > 0.95 < 25/45 0.89 UL, cUL 35 AA21 PS
1 CSD-UV42PBM 120~277 0.28~0.13 34 > 0.95 < 25/45 0.89 UL, cUL 35 AA20 PS
1 EB-139HO-1-TP 120 0.48 33 > 0.50 < 150 0.90 UL, cUL 26 N1 RS
1 EB-1382D-1-TPws 120 0.56 37 > 0.50 < 150 0.95 UL, cUL 26 S1 RS
1 EB-1382D-1-TP-SC# 120 0.56 37 > 0.50 < 150 0.95 UL, cUL 26 L8 RS
1 EB-224HO-UV-TP-PS 120~277 0.33~0.15 40 > 0.95 < 12 1.0 UL, cUL 37 U4 RS
1 EB-242T-UV-TP-PSD 120~277 0.31~0.14 37 > 0.95 < 12 0.88 UL, cUL 35 W2 PS
1 EB-242T-UV-TP-PIC-DW 120~277 0.31~0.14 37 > 0.95 < 12 0.88 UL, cUL 35 W2 RS
1 EPD-340BXM 347 0.10 34 > 0.98 < 15 0.89 UL, cUL 58 AA1 IS
1 EPSD-A40PBXM 120~277 0.27~0.13 34 > 0.98 < 10/15 0.84 UL, cUL 58 AA1 IS
1 FSD-A32PBMws 120~277 0.29~0.13 34 > 0.97 < 10/30 0.83 UL, cUL 35 AA23 PS
1 FSD-B32PBMws 277~347 0.13~0.1 34 > 0.99 < 10/15 0.82 UL, cUL 35 AA23 PS
1 GSD-A32PBM 120~277 0.29~0.13 34 > 0.97 < 10/30 0.83 UL, cUL 35 AA24 PS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
Ele
ctr
onic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
LONG TWIN LAMPS 2G11 BASE
A34Long Twin Tube
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
36WFT36W/
2G11
2 CSD-B42PBMws 277~347 0.25~0.21 68 > 0.98 < 10/15 0.88 UL, cUL 33 AA20 PS
2 CSD-B42PSws 277~347 0.25~0.21 68 > 0.98 < 10/15 0.88 UL, cUL 33 AA19 PS
2 CSD-UV32P/BM 120~277 0.52~0.24 63 > 0.99 < 10/15 0.88 UL, cUL 33 AA18 PS
2 CSD-UV32PSX 120~277 0.52~0.24 63 > 0.99 < 10 0.88 UL, cUL 33 AA15 PS
2 CSD-UV42P 120~277 0.51~0.23 63 > 0.98 < 10/20 0.91 UL, cUL 33 AA19 PS
2 CSD-UV42P/BM 120~277 0.51~0.23 63 > 0.98 < 10/20 0.91 UL, cUL 33 AA21 PS
2 EB-239HO-UV-TP-PSws 120~277 0.62~0.27 74 > 0.98 < 10 0.95 UL, cUL 36 U4 PS
2 EB-242T-UV-TP-PSD 120~277 0.55~0.24 66 > 0.98 < 10 0.80 UL, cUL 33 W2 PS
2 EB-242T-UV-TP-PIC-DW 120~277 0.55~0.24 66 > 0.98 < 10 0.80 UL, cUL 33 W2 RS
2 EPD-340BXM 347 0.156 54 > 0.99 < 10 0.78 UL, cUL 59 AA1 IS
2 EPSD-A40PBXM 120~277 0.46~0.20 56 > 0.99 < 10 0.76 UL, cUL 59 AA1 IS
2 EPT-340PBXM 347 0.18 64 > 0.99 < 10 0.69 UL, cUL 59 AA1 IS
2 FSD-A32PBMws 120~277 0.51~0.23 62 > 0.98 < 10/15 0.81 UL, cUL 33 AA23 PS
2 FSD-B32PBMws 277~347 0.23~0.19 63 > 0.99 < 10 0.80 UL, cUL 33 AA23 PS
2 GSD-A32PBM 120~277 0.51~0.23 62 > 0.98 < 10/15 0.81 UL, cUL 33 AA24 PS
3 EPT-340PBXM 347 0.24 85 > 0.99 < 10 0.76 UL, cUL 66 AA1 IS
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
LONG TWIN LAMPS 2G11 BASE
A35Long Twin Tube
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs
ws This item is well stocked
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
40WFT40W/
2G11RS
1 CSD-UV42P 120~277 0.36~0.17 43 > 0.97 < 20/35 0.91 UL, cUL 35 AA19 PS
1 CSD-UV42P/BM 120~277 0.36~0.17 43 > 0.95 < 20/35 0.91 UL, cUL 35 AA21 PS
1 CSD-UV42PBMws 120~277 0.36~0.17 43 > 0.95 < 20/35 0.91 UL, cUL 35 AA20 PS
1 EB-139HO-1-TP 120 0.55 38 > 0.50 < 150 0.90 UL, cUL 26 N1 RS
1 EB-142T-1-TP-SC # 120 0.56 39 > 0.50 < 120 0.85 UL, cUL 26 L8 RS
1 EB-242T-UV-TP-PSD 120~277 0.37~0.17 45 > 0.96 < 10 1.00 UL, cUL 35 W2 PS
1 EB-242T-UV-TP-PIC-DW 120~277 0.37~0.17 45 > 0.96 < 10 1.00 UL, cUL 35 W2 RS
1 EPD-132T8M 120 0.31 38 > 0.99 < 10 0.95 UL, cUL 35 AA27 IS
1 EPD-332T8M 347 0.11 39 > 0.99 < 10 0.98 UL, cUL 31 AA27 IS
1 EPD-340BXM 347 0.12 41 > 0.98 < 15 1.05 UL, cUL 58 AA1 IS
1 EPD-A32T8M 120~277 0.31~0.14 38 > 0.99 < 10/15 0.95 UL, cUL 35 AA27 IS
1 EPS-A32T8M 120~277 0.34~0.1 41 > 0.98 < 10/15 0.96 UL, cUL 6 AA27 RS
1 EPSD-A40PBXM 120~277 0.35~0.16 42 > 0.98 < 10/15 0.99 UL, cUL 58 AA1 IS
1 ESD-332T8M 347 0.18 41 > 0.96 < 20 0.96 UL, cUL 6 AA1 RS
1 FSD-A32PBMws 120~277 0.36~0.17 43 > 0.97 < 10/30 1.01 UL, cUL 35 AA23 PS
1 FSD-B32PBMws 277~347 0.16~0.13 43 > 0.99 < 15 1.04 UL, cUL 35 AA23 PS
1 GSD-A32PBM 120~277 0.36~0.17 43 > 0.97 < 10/30 1.01 UL, cUL 35 AA24 PS
2 CSD-B42PBMws 277~347 0.32~0.26 88 > 0.99 < 10 0.91 UL, cUL 33 AA20 PS
2 CSD-B42PS 277~347 0.32~0.26 88 > 0.99 < 10 0.91 UL, cUL 33 AA19 PS
2 CSD-UV42P 120~277 0.66~0.29 79 > 0.98 < 10/20 0.95 UL, cUL 33 AA19 PS
2 CSD-UV42P/BMws 120~277 0.66~0.29 80 > 0.98 < 10/20 0.85 UL, cUL 33 AA21 PS
2 CSD-UV42PBM 120~277 0.66~0.29 80 > 0.98 < 10/20 0.85 UL, cUL 33 AA20 PS
2 EB-242T-UV-TP-PSD 120~277 0.69~0.30 82 > 0.98 < 10 0.95 UL, cUL 33 W2 PS
2 EB-242T-UV-TP-PIC-DW 120~277 0.69~0.30 82 > 0.98 < 10 0.95 UL, cUL 33 W2 RS
2 EPD-132T8M 120 0.50 58 > 0.99 < 10 0.75 UL, cUL 33 AA27 IS
2 EPD-332T8M 347 0.18 58 > 0.99 < 10 0.77 UL, cUL 12 AA27 IS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
LONG TWIN LAMPS 2G11 BASE
A36Long Twin Tube
ws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Ele
ctr
onic
Balla
sts
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
40WFT40W/2
G11RS
2 EPD-340BXM 347 0.196 68 > 0.99 < 10 0.88 UL, cUL 59 AA1 IS
2 EPD-A32T8M 120~277 0.5~21 58 > 0.99 < 10/15 0.95 UL, cUL 12 AA27 IS
2 EPQ-132T8M 120 0.59 70 > 0.99 < 10 0.89 UL, cUL 33 AA27 IS
2 EPQ-A32T8M 120~277 0.59~0.28 70 > 0.97 < 10 0.89 UL, cUL 33 AA27 IS
2 EPS-A32T8M 120~277 0.53~0.28 64 > 0.98 < 10/15 0.76 UL, cUL 5 AA27 RS
2 EPSD-A40PBXM 120~277 0.57~0.25 68 > 0.99 < 10 0.88 UL, cUL 59 AA1 IS
2 EPT-132T8M 120 0.59 70 > 0.99 < 10 0.89 UL, cUL 33 AA27 IS
2 EPT-340PBXM 347 0.24 83 > 0.99 < 10 1.09 UL, cUL 59 AA1 IS
2 EPT-A32T8M 120~277 0.60~0.27 72 > 0.99 < 10 0.89 UL, cUL 12 AA27 IS
2 ESD-332T8M 347 0.28 64 > 0.99 < 15 0.76 UL, cUL 5 AA1 RS
3 EPQ-132T8M 120 0.77 93 > 0.99 < 10 0.82 UL, cUL 52 AA27 IS
3 EPQ-A32T8M 120~277 0.77~0.34 93 > 0.98 < 10 0.82 UL, cUL 52 AA27 IS
3 EPT-340PBXM 347 0.31 107 > 0.99 < 10 0.89 UL, cUL 66 AA1 IS
3 ESPQ-132T8HO 120 0.91 109 > 0.99 < 10 0.95 UL, cUL 57 AA22 RS
3 ESPQ-332T8HO 347 0.33 113 > 0.99 < 10 0.99 UL, cUL 57 AA22 RS
4 ESPQ-132T8HO 120 1.36 163 > 0.99 < 10 0.72 UL, cUL 42 AA22 RS
4 ESPQ-332T8HO 347 0.43 149 > 0.99 < 10 0.92 UL, cUL 42 AA22 RS
50WFT50W/2
G11RS
1 CSD-B42PBMws 277~347 0.17~0.14 47 > 0.97 < 10/20 0.78 UL, cUL 35 AA20 PS
1 CSD-UV42P 120~277 0.39~0.18 43 > 0.97 < 20/35 0.91 35 AA19 PS
1 CSD-UV42P/BM 120~277 0.39~0.18 48 > 0.98 < 20/35 0.88 UL, cUL 35 AA21 PS
1 CSD-UV42PBM 120~277 0.39~0.18 48 > 0.98 < 20/35 0.88 UL, cUL 35 AA20 PS
1 EB-154HO-1-TP 120 0.73 48 > 0.50 < 150 0.90 UL, cUL 26 N1 RS
1 EB-155-1-TP-SC# 120 0.82 58 > 0.50 < 150 1.0 UL, cUL 26 L8 RS
1 EB-254HO-UV-TP-PS 120~277 0.49~0.22 57 > 0.92 < 12 1.0 UL, cUL 37 U4 PS
1 EPD-A55PBXM 120~277 0.52~0.22 62 > 0.99 < 10 1.1 UL, cUL 58 AA1 IS
1 FSD-A32PBMws 120~277 0.40~0.18 48 > 0.98 < 10/20 0.8 UL, cUL 35 AA23 PS
1 FSD-B32PBMws 277~347 0.18~0.14 48 > 0.99 < 10 0.78 UL, cUL 35 AA23 PS
1 GSD-A32PBM 120~277 0.40~0.18 48 > 0.98 < 10/20 0.8 UL, cUL 35 AA24 PS
2 EB-254HO-UV-TP-PS 120~277 0.98~0.43 115 > 0.98 < 10 1.0 UL, cUL 36 U4 PS
2 EPD-A55PBXM 120~277 0.85~0.37 102 > 0.99 < 10 0.99 UL, cUL 59 AA1 IS
2 EPQ-A55PBX-S 120~277 0.85~0.37 102 > 0.99 < 10 0.99 UL, cUL 59 AA1 IS
4 EPD-A55PBXM 120~277 0.85~0.37 102 > 0.99 < 10 0.99 UL, cUL 59 AA1 IS
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLAST FOR
LONG TWIN LAMPS 2G11 BASE
A37
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
Factor
Approvals Wiring
Dia.
Dimen
-sions
Staring
Method
55W FT55W/2G11RS
1 CSD-B42PBMws 277~347 0.17~0.15 47 > 0.95 < 15/20 0.69 UL, cUL 35 AA20 PS
1 CSD-UV42P 120~277 0.36~0.16 44 > 0.95 < 20/35 0.67 UL, cUL 35 AA19 PS
1 CSD-UV42P/BMws 120~277 0.36~0.16 44 > 0.97 < 20/35 0.67 UL, cUL 35 AA21 PS
1 CSD-UV42PBMws 120~277 0.36~0.16 44 > 0.97 < 20/35 0.67 UL, cUL 35 AA20 PS
1 EB-154HO-1-TP 120 0.73 48 > 0.50 < 150 0.85 UL, cUL 35 NQ RS
1 EB-155-1-TP-SC# ws 120 0.74 52 > 0.50 < 120 0.90 UL, cUL 26 L8 RS
1 EB-254HO-UV-TP-PS 120~277 0.46~0.21 55 > 0.92 < 12 0.86 UL, cUL 37 U4 PS
1 EPD-A55PBXM 120~277 0.52~0.22 62 > 0.99 < 10 1.1 UL, cUL 58 AA1 IS
2 EB-254HO-UV-TP-PS 120~277 0.90~0.38 106 > 0.99 < 10 0.85 UL, cUL 36 U4 PS
2 EPD-A55PBXM 120~277 0.52~0.22 62 > 0.99 < 10 1.1 UL, cUL 58 AA1 IS
Long Twin Tube
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studs.
ws This item is well stocked
ElectronicBallast
Ele
ctr
onic
Balla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A38
ELECTRONIC BALLAST FORCIRCLINE LAMPS
Circline Lamps
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
Approvals WiringDia.
Dimen-sions
StaringMethod
22W FC8T91 EB-1C22-1-TP-WSws 120 0.33 21 > 0.50 < 150 0.90 UL, cUL 10 S1 RS
1 EB-1C22-1-TP-WS-LC 120 0.33 21 > 0.50 < 150 0.90 UL, cUL 10 L1 RS
22W FC9T5
1 EB-126-1-TP 120 0.34 22 > 0.50 < 150 1.0 UL, cUL 10 S1 RS
1 EB-126-1-TP-LC 120 0.34 22 > 0.50 < 150 1.0 UL, cUL 10 L2 RS
1 CSD-UV18Pws 120~277 0.17~0.08 21 > 0.97 < 15 1.08 UL, cUL 35 AA15 PS
1 CSD-UV-18PBM 120~277 0.17~0.08 21 > 0.98 < 15 1.08 UL, cUL 35 AA16 PS
1 EB-242T-UV-TP-PSD 120~277 0.27~0.13 31 > 0.93 < 15 1.2 UL, cUL 33 W2 PS
1 EB-242T-UV-TP-PIC-DW 120~277 0.27~0.13 31 > 0.93 < 15 1.2 UL, cUL 33 W2 RS
2 EB-242T-UV-TP-PSD 120~277 0.49~0.22 59 > 0.97 < 10 1.1 UL, cUL 35 W2 PS
2 EB-242T-UV-TP-PIC-DW 120~277 0.49~0.22 59 > 0.97 < 10 1.1 UL, cUL 35 W2 RS
30W FCL-301 EB-1C3032-1-TP-WSws 120 0.50 32 > 0.50 < 150 0.95 UL, cUL 10 S1 RS
1 EB-1C3032-1-TP-WS-LC 120 0.50 32 > 0.50 < 150 0.95 UL, cUL 10 L2 RS
32W FC12T91 EB-1C3032-1-TP-WSws 120 0.55 37 > 0.50 < 150 1.0 UL, cUL 10 S1 RS
1 EB-1C3032-1-TP-WS-LC 120 0.55 37 > 0.50 < 150 1.0 UL, cUL 10 L2 RS
40W FC12T5
1 EB-1382D-1-TP-WS 120 0.62 41 > 0.50 < 150 0.95 UL, cUL 10 S1 RS
1 EB-1382D-1-TP-LC-WS 120 0.62 41 > 0.50 < 150 0.95 UL, cUL 10 L2 RS
1 EB-242T-UV-TP-PSD 120~277 0.37~0.17 45 > 0.96 < 10 1.0 UL, cUL 33 W2 PS
1 EB-242T-UV-TP-PIC-DW 120~277 0.37~0.17 45 > 0.96 < 10 1.0 UL, cUL 33 W2 RS
2 EB-242T-UV-TP-PSD 120~277 0.69~0.30 82 > 0.97 < 10 0.95 UL, cUL 35 W2 PS
2 EB-242T-UV-TP-PIC-DW 120~277 0.69~0.30 82 > 0.97 < 10 0.95 UL, cUL 35 W2 PS
40W FC16T9
1 EB-226-UV-TP-PIC 120~277 0.36~0.16 42 > 0.97 < 10 1.0 UL, cUL 35 T1 RS
1 EB-226-UV-TP-PIC-DW 120~277 0.36~0.16 42 > 0.97 < 10 1.0 UL, cUL 35 W1 RS
1 EB-1382D-1-TP-WS 120 0.63 43 > 0.50 < 130 0.95 UL, cUL 10 S1 RS
1 EB-1382D-1-TP-LC-WS 120 0.63 43 > 0.50 < 130 0.95 UL, cUL 10 L2 RS
22+32 FC8T9+FC12T92 EB-2C72-1-TP-WS 120 0.60 40 > 0.50 < 150 0.76 UL, cUL 11 L1 RS
2 EB-2C54PS-1-TP-WS 120 0.68 48 > 0.50 < 130 0.85 UL, cUL 11 L1 PS
22+40 FC9T5+FC12T52 EB-242T-UV-TP-PSD 120~277 0.55~0.25 67 > 0.98 < 10 0.90 UL, cUL 35 W2 PS
2 EB-242T-UV-TP-PIC-DW 120~277 0.55~0.25 67 > 0.98 < 10 0.90 UL, cUL 35 W2 RS
32+40 FC12T9+FC16T9 2 EB-2C72-1-TP-WS 120 0.75 50 > 0.50 < 150 0.70 UL, cUL 11 L1 RS
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studsws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A39
ELECTRONIC BALLAST FOR2D LAMPS
2D Lamps
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
Approvals WiringDia.
Dimen-sions
StaringMethod
2D
21W CFS28W/GR10q
1 EB-1C22-1-TP 120 0.30 19 > 0.50 < 150 0.85 UL, cUL 27 S1 RS
1 EB-1C22-1-TP-LC 120 0.30 19 > 0.50 < 150 0.85 UL, cUL 27 L1 RS
1 EB-218-UV-TP-PICws 120~277 0.20~0.09 24 > 0.95 < 12 1.05 UL, cUL 35 T1 RS
1 EB-218-UV-TP-PIC-DWws 120~277 0.20~0.09 24 > 095 < 12 1.05 UL, cUL 35 W1 RS
1 EB-118-1-TP-SC # 120 0.28 18 > 0.50 < 150 0.80 UL, cUL 27 L8 RS
1 EB-218-UV-TP-PSD 120~277 0.17~0.07 20 > 0.95 < 10 0.85 UL, cUL 35 W1 PS
2 EB-218-UV-TP-PSD 120~277 0.31~0.13 37 > 0.98 < 10 0.80 UL, cUL 33 W1 PS
2 EB-226-UV-TP-PSD 120~277 0.35~0.15 42 > 0.98 < 10 0.92 UL, cUL 33 W1 PS
28W CFS28W/GR10q
1 EB-126-1-TP 120 0.40 28 > 0.50 < 130 0.90 UL, cUL 27 S1 RS
1 EB-142T-1-TP-SC # 120 0.45 30 > 0.50 < 130 0.95 UL, cUL 27 L8 RS
1 EB-218-UV-TP-PICws 120~277 0.26~0.12 31 > 0.97 < 10 1.0 UL, cUL 35 T1 RS
1 EB-218-UV-TP-PIC-DWws 120~277 0.26~0.12 31 > 0.97 < 10 1.0 UL, cUL 35 W1 RS
1 EB-226-UV-TP-PSD 120~277 0.25~0.11 30 > 0.97 < 10 0.95 UL, cUL 35 W1 PS
1 EB-242T-UV-TP-PSD 120~277 0.29~0.14 34 > 0.93 < 15 1.0 UL, cUL 35 W2 PS
1 EB-242T-UV-TP-PIC-DW 120~277 0.29~0.14 34 > 0.93 < 15 1.0 UL, cUL 35 W2 RS
38W CFS38W/GR10q 1 EB-1382D-1-TPws 120 0.60 40 > 0.50 < 150 0.95 UL, cUL 27 S1 RS
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studsws This item is well stocked
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
Ele
ctr
onic
Balla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A40GU24 Adapter Ballasts
ELECTRONIC BALLAST FORENERGY SAVING GU-24 LAMPS
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
Approvals WiringDia.
Dimen-sions
StaringMethod
13W CFQ13W/G24q 1 EB-113-1-TP-AD 120 0.22 14 > 0.50 <150 1.02 UL, cUL 26 Y1 PH
13W CFTR13W/GX24q 1 EB-113-1-TP-AD 120 0.22 14 > 0.50 <150 1.02 UL, cUL 26 Y1 PH
18W CFQ18W/G24q 1 EB-118-1-TP-AD 120 0.24 16 > 0.50 <150 0.85 UL, cUL 26 Y1 PH
18W CFTR18W/GX24Q 1 EB-118-1-TP-AD 120 0.24 16 > 0.50 <150 0.85 UL, cUL 26 Y1 PH
26W CFTR26W/GX24q 1 EB-126-1-TP-ADw 120 0.31 21 > 0.50 <150 0.80 UL, cUL 26 Y1 PS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ElectronicBallast
Ele
ctro
nic
Balla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A41Dimming Ballast
DIMMING BALLASTS
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
Approvals WiringDia.
Dimen-sions
StaringMethod
T528W F28T5 1 EB-128-1-TP-LDIM 120 PENDING
T8
32W F32T8 1 EB-132-1-TP-LDIM 120120 PENDING
CFL
26WCFQ26W/
G24q1
EB-126-1-TP-DIM full power 120 0.31 31 0.840 < 150 1.05 UL, cUL 26 W1 RS
Least power 120 0.58 10 0.15 --- --- --- --- --- ---
CIRCLINE
30W FCL-30 1EB-1C30-1-TP-DIM full power 120 0.28 25 0.74 < 150 0.80 UL, cUL 10 S2 RS
Least power 120 0.55 9 0.15 --- --- --- --- --- ---
2D
55WCFS55W/
GR10q1
EB-1552D-1-TP-LDIM full power 120 0.85 0.85 59 0.57 < 150 RU, cRU 27 AC1 RS
Least power 120 0.49 29 0.50 --- --- --- --- --- ---
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
# replace “-SC” with “-SCS” for model with studs; with “SC-RJ” for model with bottom out leads; with “-SC-RJS” with bottom out leads and with studsws This item is well stocked
BallastsDisconnects
Balla
st
Dis
connects
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
“POWER-SAFE” BALLAST DISCONNECTS
A42Ballast Disconnects
Model Electrical Rating Wire TypeWire Range -
Line SideWire Range -
Load SideQuantity and
PackedCat No.
BD2-2 6 A/600V Solid 12 AWG - 18 AWG 12 AWG - 18 AWG 1,000 pcs - boxed100 pcs - poly bagged 20 pcs - blister boxed
BD2-2BD2-2/CPBBD2-2/BB
Stranded 12 AWG - 14 AWG 12 AWG - 14 AWG19 strand or less
BD2-4 6 A/600V 1,000 pcs - boxed100 pcs - poly bagged20 pcs - blister boxed
BD2-4BD2-4/CPBB2-4/BB
Stranded Tinned 12 AWG =/< 19 strand14 AWG =/< 19 strand16 AWG =/< 26 strand18 AWG =/< 16 strand
12 AWG =/< 19 strand14 AWG =/< 19 strand16 AWG =/< 26 strand18 AWG =/< 16 strandBD3-3 6 A/600V 1,000 pcs - boxed
100 pcs - poly bagged20 pcs - blister boxed
BD3-3BD3-3/CPBBD3-3/BB
BD2-2 BD2-4 BD3-3
Specifications:
Housing: Polycarbonate (PC) Rated UL94 V-0 Contacts: Copper AlloyTemp.Rating: Working temperature - 105C (221F).Electrical Rating: 6A 600V on line side, 6A on load sizeStrip Length: 3/8”
SIZES IN MM SIZES IN MM SIZES IN MM
BallastDisconnects
Balla
st D
isconnects
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
“POWER-SAFE” BALLAST DISCONNECTS
A43Ballast Disconnects
The Etlin Daniels “Power-Safe” Luminaire Disconnects fully meets the 2008 National Electrical Code 410.130(G),2005 NEC 410.73(G) and Canadian Electrical Code 30-308(4) for non-residential fluorescent luminaires. The ED“Ballast quick latch” helps protect electricians from electrical shock hazard during ballast replacement by safelydisconnecting hot and neutral ballast wiring. Both halves of the “BD Series ” meet UL finger-probe safetyrequirements. The ED “BD Series” is available in 2-pole and 3-pole models with options for new installations orballast retrofitting. Quick wire push-in terminations provides fast, efficient ballast connections for faster installationtimes and labor savings. There is no need for additional pigtails that require additional connectors and labor.
Features:
• Meets CEC and NEC code changes for non-residential fluorescent luminaires with ballasts• Perfect for fixture OEM’s or retrofit lighting applications or facility maintenance electrical personnel. • Well designed. Color coded Push-in wire ports make wiring easy and quickly lock wires in place and can be
used with a wide range of either solid or stranded wire sizes. • Pieces pull apart safely with ease by simply pushing down on the integrated locking latch when needed for
ballast servicing without disconnecting the power.• Dead front design in all wiring areas which protects the installer from touching any live wires.• Fool-proof keyed design enables mating halves of the disconnect to be installed only one way, eliminating
possible incorrect polarization• Oversize electrical contacts which improve conductivity and reduce the temperature rise. • Some models can be daisy chained to wire to another ballast (BD2-4) or wired for dimming circuits (BD3-3) • Passes UL 2459 & CSA 182.3 finger probe requirements• Fits through 1/2 in. knockout.• Built in 3/8 in. strip length indicator
Etlin-Daniels reserves the right to discontinue, modify designs and change specifications without incurring obligation. While every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct,no warranty is given in respect thereof and the company shall not be liable for any error herein.Copyright © 2011 Etlin-Daniels
MA
GN
ET
IC B
ALLA
ST
S
A44
1850 Wilson Avenue, Toronto,Ontario, Canada, M9M 1A1
Ph: 416-741-7336 Fax: 416-741-9104www.etlin.com
SECTION A
BALLASTS
MAGNETIC BALLASTS
Electronic Ballasts A1-A41
Ballast Disconnects A42-A43
Magnetic Ballasts A44T5 Straight Lamps A45T8 Straight Lamps A46-A47T12 Straight Lamps A48-51Compact Lamps A52-A53Circline Lamps A54Sign Ballasts A55Emergency Ballasts A56-A64
Appendix: Wiring Diagrams & Case Styles A65-A73
Appendix: Electronic Ballasts: Standard Lead Lengths & Standard Packaging A74-A79
Suffix Guide A80
MagneticBallast
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
MAGNETIC BALLASTS FORFLUORESCENT LAMPS
A45T5 Straight Lamps
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
* Add –PF for single blow thermal fuse or Add– TP for Class P type% Replace –OC by –WC for With Cord modelws This item is well stocked
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
ApprovalsWiringDia.
Dimen-sions
StaringMethod
4W F4T51 CF-49-CC * 120 0.12 8 > 0.55 < 15 0.80 UL, cUL 1 B1 PH
1 CF-49-OC * % 120 0.12 8 > 0.55 < 15 0.80 UL, cUL 1 A1 PH
6W F6T5
1 CF-49-CC ws * 120 0.12 8 > 0.55 < 15 0.80 UL, cUL 1 B1 PH
1 CF-49-OC * % 120 0.12 8 > 0.55 < 15 0.80 UL, cUL 1 A1 PH
1 CF-68T5-PG 120 0.15 8 > 0.45 < 20 0.80 UL, cUL 9 E2 PH
8W F8T5
1 CF-49-CC ws * 120 0.12 8 > 0.50 < 15 0.80 UL, cUL 1 B1 PH
1 CF-49-OC * % 120 0.12 8 > 0.50 < 15 0.80 UL, cUL 1 A1 PH
1 CF-579-CC * 120 0.14 9 > 0.50 < 15 0.82 UL, cUL 1 B1 PH
1 CF-579-OC * % 120 0.14 9 > 0.50 < 15 0.82 UL, cUL 1 A1 PH
1 CF-68T5-PG 120 0.13 8 > 0.50 < 20 0.80 UL, cUL 9 E2 PH
1 N-113-1-TP-IES 120 0.17 10 > 0.50 < 20 0.97 UL, cUL 19 C6 IES
2 N-213-1-TP-IES 120 0.31 19 > 0.50 < 20 0.97 UL, cUL 20 J1 IES
13W F13T5
1 N-113A-1-TP 120 0.28 17 > 0.50 < 15 0.84 UL, cUL 16 C6 PH
1 N-113A-1-TP-SS 120 0.28 17 > 0.50 < 15 0.84 UL, cUL 6 C6 PH
1 N-113-1-TP-IES 120 0.16 14 > 0.75 < 30 0.79 UL, cUL 19 J1 IES
1 CF-13T5-PG 120 0.17 16 > 0.80 < 30 0.80 UL, cUL 9 E3 PH
2 N-213-1-TP-IES 120 0.30 27 > 0.75 < 30 0.79 UL, cUL 20 J1 IES
Magnetic B
alla
sts
MagneticBallast
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
MAGNETIC BALLASTS FORFLUORESCENT LAMPS
A46T8 Straight Lamps
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
* Add –PF for single blow thermal fuse or Add– TP for Class P type% Replace –OC by –WC for With Cord modelws This item is well stocked
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
ApprovalsWiringDia.
Dimen-sions
StaringMethod
14W F14T8
1 CF-1322-CC ws * 120 0.33 16 > 0.40 < 15 0.80 UL, CSA 1 B2 PH
1 CF-1322-OC * % 120 0.33 16 > 0.40 < 15 0.80 UL, CSA 1 A2 PH
1 CF-1322M-CC ws * 120 0.33 16 > 0.40 < 15 0.80 UL, cUL 1 B2 PH
1 CF-1322M-OC * % 120 0.33 16 > 0.40 < 15 0.80 UL, cUL 1 A2 PH
1 CF-1320S-CC ws * 120 0.33 16 > 0.40 < 15 0.80 UL, cUL 1 B4 PH
1 CF-1320S-OC ws * % 120 0.33 16 > 0.40 < 15 0.80 UL, cUL 1 A4 PH
1 CF-1320LH-OC * 120 0.33 16 > 0.40 < 15 0.80 UL, cUL 1 A4 PH
1 CF-1320LH-CC * 120 0.33 16 > 0.40 < 15 0.80 UL, cUL 1 B4 PH
15W F15T8
1 CF-1322-CC ws * 120 0.27 17 > 0.50 < 15 0.82 UL, CSA 1 B2 PH
1 CF-1322-OC * % 120 0.27 17 > 0.50 < 15 0.82 UL, CSA 1 A2 PH
1 CF-1322M-CC ws * 120 0.27 17 > 0.50 < 15 0.86 UL, CSA 1 B2 PH
1 CF-1322M-OC * % 120 0.27 17 > 0.50 < 15 0.86 UL, cUL 1 A2 PH
1 CF-1320S-CC ws * 120 0.27 17 > 0.50 < 20 0.82 UL, cUL 1 B4 PH
1 CF-1320S-OC ws * % 120 0.27 17 > 0.50 < 20 0.82 UL, cUL 1 A4 PH
1 CF-1320LH-OC * 120 0.27 17 > 0.50 < 20 0.82 UL, cUL 1 A4 PH
1 CF-1320LH-CC * 120 0.27 17 > 0.50 < 20 0.82 UL, cUL 1 B4 PH
1 N-120-1-TP ws 120 0.63 31 > 0.40 < 10 1.0 UL, cUL 4 D1 TS
1 CF-1540-1-TP-IES ws 120 0.32 17 > 0.45 < 30 0.93 UL, cUL 19 C7 IES
2 N-220-1-TP ws 120 0.65 35 > 0.45 < 20 0.70 UL, cUL 5 C1 TS
17W F17T8
1 N-117-1-TP ws 120 0.44 23 > 0.45 < 20 0.95 UL, cUL 4 D1 RS
1 N-117SL-1-TP 120 0.44 23 > 0.45 < 20 0.95 UL, cUL 4 C6/J1 RS
1 N-117-1-TP-HP 120 0.21 23 > 0.90 < 20 0.95 UL, cUL 4 D1 RS
18W F18T8
1 CF-1322-CC ws * 120 0.23 15 > 0.55 < 15 0.68 UL, cUL 1 B2 PH
1 CF-1322-OC * % 120 0.23 15 > 0.55 < 15 0.68 UL, CSA 1 A2 PH
1 CF-1322M-CC ws * 120 0.23 15 > 0.55 < 15 0.68 UL, CSA 1 B2 PH
1 CF-1322M-OC * % 120 0.23 15 > 0.55 < 15 0.71 UL, cUL 1 A2 PH
1 CF-1320S-CC ws * 120 0.23 15 > 0.55 < 15 0.71 UL, cUL 1 B4 PH
1 CF-1320S-OC * % 120 0.23 15 > 0.55 < 15 0.68 UL, cUL 1 A4 PH
1 CF-1320LH-OC * 120 0.23 15 > 0.55 < 15 0.68 UL, cUL 1 A4 PH
1 CF-1320LH-CC * 120 0.23 15 > 0.55 < 15 0.68 UL, cUL 1 B4 PH
25W F25T8
1 N-125-1-TP ws 120 0.51 31 > 0.50 < 20 0.95 UL, cUL 4 D1 RS
1 N-125SL-1-TP 120 0.51 31 > 0.50 < 20 0.95 UL, cUL 4 C6/J1 RS
1 N-125-1-TP-HP 120 0.28 31 > 0.90 < 20 0.95 UL, cUL 4 D1 RS
Magnetic
Balla
sts
MagneticBallast
Magnetic B
alla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A47
MAGNETIC BALLASTS FORFLUORESCENT LAMPS
T8 Straight Lamps
ws This item is well stocked
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
ApprovalsWiringDia.
Dimen-sions
StaringMethod
30W F30T8
1 N-140A-1-TP ws 120 0.60 36 > 0.50 < 15 0.88 UL, cUL 16 D1 PH
1 N-140A-1-TP-SS 120 0.60 36 > 0.50 < 15 0.88 UL, cUL 6 D1 PH
1 N-140A-1-TP-WC 120 0.60 36 > 0.50 < 15 0.88 UL, cUL 17 D1 PH
32W F32T8
1 N-132-1-TP ws 120 0.52 33 > 0.50 < 20 0.84 UL, cUL 4 D1 RS
1 N-132SL-1-TP 120 0.52 33 > 0.50 < 20 0.84 UL, cUL 4 C6/J1 RS
1 N-132-1-TP-HP 120 0.31 33 > 0.90 < 20 0.84 UL, cUL 4 D1 RS
2 ES-232-1-TP ws 120 0.65 70 > 0.90 < 10 0.90 UL, cUL 5 C2 RS
2 ES-232-2-TP 277 0.28 70 > 0.90 < 10 0.90 UL, cUL 5 C2 RS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
MagneticBallast
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A48
MAGNETIC BALLASTS FORFLUORESCENT LAMPS
T12 Straight Lamps
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
* Add –PF for single blow thermal fuse or –TP for resettable thermal protector % Replace –OC by –WC for With Cord model# Add –WS for standard bi-pin lampholders attached @ Add –LC for using 9” long canWS This item is well stocked
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
ApprovalsWiringDia.
Dimen-sions
StaringMethod
14W F14T12
1 CF-1322-CCWS * 120 0.33 16 > 0.40 < 15 0.80 UL, CSA 1 B2 PH
1 CF-1322-OC * % 120 0.33 16 > 0.40 < 15 0.80 UL, CSA 1 A2 PH
1 CF-1322M-CC ws * 120 0.33 16 > 0.40 < 15 0.80 UL, cUL 1 B2 PH
1 CF-1322M-OC * % 120 0.33 16 > 0.40 < 15 0.80 UL, cUL 1 A2 PH
1 CF-1320S-CC ws * 120 0.33 16 > 0.40 < 15 0.80 UL, cUL 1 B4 PH
1 CF-1320S-OC ws * % 120 0.33 16 > 0.40 < 15 0.80 UL, cUL 1 A4 PH
1 CF-1320LH-OC * 120 0.33 16 > 0.40 < 15 0.80 UL, cUL 1 A4 PH
1 CF-1320LH-CC * 120 0.33 16 > 0.40 < 15 0.80 UL, cUL 1 B4 PH
1 N-120-1-TP ws 120 0.69 29 > 0.35 < 10 0.93 UL, cUL 4 D1 TS
15W F15T12
1 CF-1322-CC ws * 120 0.32 17 > 0.45 < 15 0.85 UL, cUL 1 B2 PH
1 CF-1322-OC * % 120 0.32 17 > 0.45 < 15 0.85 UL, cUL 1 A2 PH
1 CF-1322M-CC ws * 120 0.32 17 > 0.45 < 15 0.85 UL, cUL 1 B2 PH
1 CF-1322M-OC * % 120 0.32 17 > 0.45 < 15 0.85 UL, cUL 1 A2 PH
1 CF-1320S-CC ws * 120 0.32 17 > 0.45 < 15 0.85 UL, cUL 1 B4 PH
1 CF-1320S-OC ws * % 120 0.32 17 > 0.45 < 15 0.85 UL, cUL 1 A4 PH
1 CF-1320LH-OC * 120 0.32 17 > 0.45 < 15 0.85 UL, cUL 1 A4 PH
1 CF-1320LH-CC * 120 0.32 17 > 0.45 < 15 0.85 UL, cUL 1 B4 PH
1 CF-1540-1-TP-IES ws 120 0.35 17 > 0.40 < 20 0.90 UL, cUL 19 C7 IES
1 N-120-1-TP ws 120 0.63 31 > 0.40 < 10 1.0 UL, cUL 4 D1 TS
1 N-220-1-TP ws 120 0.65 35 > 0.45 < 20 0.70 UL, cUL 5 C1 TS
20W F20T12
1 CF-1322-CC ws * 120 0.24 17 > 0.60 < 15 0.65 UL, CSA 1 B2 PH
1 CF-1322-OC * % 120 0.24 17 > 0.60 < 15 0.65 UL, CSA 1 A2 PH
1 CF-1322M-CCWS * 120 0.24 17 > 0.60 < 15 0.65 UL, cUL 1 B2 PH
1 CF-1322M-OC * % 120 0.24 17 > 0.60 < 15 0.65 UL, cUL 1 A2 PH
1 CF-1320S-CC ws * 120 0.24 17 > 0.60 < 15 0.65 UL, cUL 1 B4 PH
1 CF-1320S-OC ws * % 120 0.24 17 > 0.60 < 15 0.65 UL, cUL 1 A4 PH
1 CF-1320LH-OC * 120 0.24 17 > 0.60 < 15 0.65 UL, cUL 1 A4 PH
1 CF-1320LH-CC * 120 0.24 17 > 0.60 < 15 0.65 UL, cUL 1 B4 PH
1 CF-1540-1-TP-IES ws 120 0.33 20 > 0.50 < 25 0.83 UL, cUL 19 C7 IES
1 N-120-1-TP ws 120 0.62 30 > 0.40 < 10 0.85 UL, cUL 4 D1 TS
2 N-220-1-TP ws 120 0.59 35 > 0.50 < 20 0.54 UL, cUL 5 C1 TS
25W F25T12 1 CF-25-WC-TP 120 0.31 22 > 0.60 < 20 0.70 UL, cUL 17 G2 PH
Magnetic
Balla
sts
MagneticBallast
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A49T12 Straight Lamps
MAGNETIC BALLASTS FORFLUORESCENT LAMPS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
# Add –WS for standard bi-pin lampholders attached @ Add –LC for using 9” long canws This item is well stocked
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
ApprovalsWiringDia.
Dimen-sions
StaringMethod
30W F30T12
1 N-140A-1-TP ws 120 0.67 35 > 0.40 < 10 0.87 UL, cUL 16 D1 PH
1 N-140A-1-TP-SS 120 0.67 35 > 0.40 < 10 0.87 UL, cUL 6 D1 PH
1 N-140A-1-TP-WC 120 0.67 35 > 0.40 < 10 0.87 UL, cUL 17 D1 PH
1 N-140-1-TP ws 120 0.61 33 > 0.45 < 10 0.95 UL, cUL 4 D1 RS
1 CF-1540-1-TP-IES ws 120 0.33 20 > 0.50 < 25 0.83 UL, cUL 19 C7 IES
2 ES-240J-1-TP 120 0.66 75 > 0.95 < 20 0.97 UL, cUL 5 C2 RS
2 ES-230-1-TP 120 0.55 64 > 0.95 < 20 0.75 UL, cUL 5 C2 RS
25W F40T12
1 N-140-1-TP ws 120 0.55 30 > 0.45 < 10 0.70 UL, cUL 4 D1 RS
1 CF-1540-1-TP-IES ws 120 0.31 30 > 0.80 < 40 0.66 UL, cUL 19 C7 IES
2 N-240-1-TP # @ 120 0.58 45 > 0.65 < 20 0.50 UL, cUL 5 C7 RS
2 N-234-1-TP # @ 120 0.52 41 > 0.65 < 20 0.36 UL, cUL 5 C7 RS
2 N-240-1-TP-IES 120 0.64 58 > 0.75 < 40 0.60 UL, cUL 20 D1 IES
2 LW-240-1-TP 120 0.58 66 > 0.95 < 30 0.67 UL, cUL 5 C2 RS
Magnetic B
alla
sts
MagneticBallast
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A50T12 Straight Lamps
MAGNETIC BALLASTS FORFLUORESCENT LAMPS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
# Add –WS for standard bi-pin lampholders attached @ Add –LC for using 9” long canws This item is well stocked
Magnetic
Balla
sts
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
ApprovalsWiringDia.
Dimen-sions
StaringMethod
34WF40T12Energy
SaverF30T8
1 N-140-1-TP ws 120 0.63 34 > 0.45 < 10 0.70 UL, cUL 4 D1 PH
1 CF1540-TP-IES ws 120 0.38 25 > 0.50 < 40 0.69 UL, cUL 19 C7 IES
1 ES-140N-1-TP ws 120 0.38 44 > 0.95 < 15 0.88 UL, cUL 6 C2 RS
1 ES-140N-2-TP 277 0.17 46 > 0.95 < 15 0.90 UL, cUL 6 C2 RS
2 N-234-1-TP # @ 120 0.80 53 > 0.5 < 15 0.60 UL, cUL 5 C1 RS
2 LW-240-1-TP 120 0.47 51 > 0.90 < 40 0.60 UL, cUL 5 C2 RS
2 N-240-1-TP-IES 120 0.70 51 > 0.60 < 40 0.60 UL, cUL 20 D1 IES
2 ES-240N-1-TP 120 0.64 75 > 0.95 < 25 0.88 UL, cUL 5 C2 RS
2 ES-240J-1-TP 120 0.70 76 > 0.90 < 20 0.88 UL, cUL 5 C2 RS
2 ES-240N-2-TP 277 0.30 78 > 0.95 < 20 0.90 UL, cUL 5 C2 RS
2 ES-240N-3-TP 347 0.22 76 > 0.95 < 20 0.90 UL, cUL 5 C2 RS
40W F40T12
1 N-140-1-TP ws 120 0.61 37 > 0.50 < 10 0.64 UL, cUL 4 D1 PH
1 N-140A-1-TP ws 120 0.60 36 > 0.50 < 10 0.72 UL, cUL 16 D1 PH
1 N-140A-1-TP-SS 120 0.60 36 > 0.50 < 10 0.72 UL, cUL 6 D1 PH
1 N-140A-1-TP-WC 120 0.60 36 > 0.50 < 10 0.72 UL, cUL 17 G1 PH
1 CF-1540-1-TP-IES ws 120 0.31 30 > 0.80 < 40 0.66 UL, cUL 19 C7 IES
1 ES-140N-1-TP ws 120 0.44 51 > 0.95 < 15 0.93 UL, cUL 6 C2 RS
1 ES-140N-2-TP 277 0.19 52 > 0.95 < 15 0.94 UL, cUL 6 C2 RS
2 N-240-1-TP # @ 120 0.64 50 > 0.65 < 20 0.45 UL, cUL 5 C1 RS
2 N-234-1-TP # @ 120 0.52 41 > 0.50 < 20 0.36 UL, cUL 5 C1 RS
2 N-240-1-TP-IES 120 0.65 59 > 0.75 < 40 0.60 UL, cUL 20 D1 IES
2 ES-240N-1-TP 120 0.77 88 > 0.95 < 20 0.91 UL, cUL 5 C2 RS
2 LW-240-1-TP 120 0.57 66 > 0.95 < 30 0.67 UL, cUL 5 C2 RS
2 ES-240J-1-TP 120 0.77 88 > 0.95 < 20 0.90 UL, cUL 5 C2 RS
2 LE-240-1-TP 120 0.68 80 > 0.95 < 20 0.81 UL, cUL 5 C2 RS
2 ES-240N-2-TP 277 0.33 88 > 0.95 < 20 0.91 UL, cUL 5 C2 RS
2 ES-240N-3-TP 347 0.25 86 > 0.95 < 20 0.90 UL, cUL 5 C2 RS
MagneticBallast
Magnetic B
alla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A51T12 Straight Lamps
MAGNETIC BALLASTS FORFLUORESCENT LAMPS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
* For model without thermal protector, remove –TP suffixws This item is well stocked
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
ApprovalsWiringDia.
Dimen-sions
StaringMethod
55W F72T12
1 ES-196-1-TP ws 120 0.73 78 < 0.90 < 30 0.80 UL, cUL 25 D4 IS
1 ES-196-2-TP 277 0.30 76 < 0.90 < 35 0.80 UL, cUL 25 D4 IS
2 ES-275-1-TP ws * 120 0.90 98 < 0.90 < 40 0.68 UL, cUL 8 D2,D4 IS
2 ES-296N-1-TP 120 1.20 133 < 0.95 < 25 0.88 UL, cUL 8 D2 IS
2 ES-296-2-TP 277 0.51 133 < 0.95 < 25 0.90 UL, CSA 15 D2 IS
2 ES-296-3-TP 347 0.40 130 < 0.95 < 40 0.90 PENDING 15 D2 IS
60WF96T12
Energy Saver
1 ES-196-1-TP ws 120 0.73 78 < 0.90 < 40 0.71 UL, cUL 25 D4 IS
1 ES-196-2-TP 277 0.30 76 < 0.90 < 40 0.73 UL, cUL 25 D4 IS
2 ES-275-1-TP ws * 120 1.1 127 < 0.90 < 30 0.72 UL, cUL 8 D2,D4 IS
2 ES-296N-1-TP 120 1.20 133 < 0.95 < 25 0.88 UL, cUL 8 D2 IS
2 ES-296-2-TP 277 0.53 131 < 0.90 < 40 0.74 UL, cUL 15 D2 IS
2 ES-296-3-TP 347 0.40 132 < 0.90 < 40 0.90 PENDING 15 D2 IS
75W F96T12
1 ES-196-1-TP ws 120 0.83 93 < 0.90 < 30 0.75 UL, cUL 25 D4 IS
2 ES-275-1-TP ws * 120 1.36 158 < 0.95 < 30 0.75 UL, cUL 8 D2,D4 IS
1 ES-196-2-TP 277 0.36 93 < 0.90 < 40 0.76 UL, cUL 25 D4 IS
2 ES-296N-1-TP 120 1.40 160 < 0.95 < 25 1.0 UL, cUL 8 D2 IS
2 ES-296-2-TP 277 0.53 131 < 0.90 < 40 0.74 UL, CSA 15 D2 IS
2 ES-296-3-TP 347 0.46 154 < 0.95 < 40 0.90 PENDING 15 D2 IS
85W F72T12/HO
1 ES-196HO-1-TP ws 120 1.1 123 < 0.90 < 35 1.0 UL, cUL 6 D8 RS
1 ES-196HO-2-TP 277 0.46 118 < 0.90 < 35 0.97 UL, cUL 6 D8 RS
2 ES-296HO-1-TP ws 120 1.85 207 < 0.90 < 20 0.94 UL, cUL 5 D8 RS
2 ES-296HO-2-TP 277 0.76 202 < 0.95 < 25 0.94 UL, cUL 5 D8 RS
2 ES-296HO-3-TP 347 0.54 186 < 0.95 < 40 0.86 UL, cUL 5 D8 RS
96WF96T12/HO ESEnergy Saver
1 ES-196HO-1-TP 120 1.4 155 < 0.90 < 40 1.0 UL, cUL 6 D8 RS
1 ES-196HO-2-TP 277 0.50 123 < 0.90 < 40 0.91 UL, cUL 6 D8 RS
2 ES-296HO-1-TP ws 120 1.95 220 < 0.92 < 20 0.93 UL, cUL 5 D8 RS
2 ES-296HO-2-TP 277 0.78 210 < 0.95 < 15 0.90 UL, cUL 5 D8 RS
2 ES-296HO-3-TP 347 0.57 195 < 0.95 < 20 0.82 UL, cUL 5 D8 RS
110W F96T12/HO
1 ES-196HO-1-TP 120 1.2 130 < 0.90 < 40 0.95 UL, cUL 6 D8 RS
1 ES-196HO-2-TP 277 0.58 147 < 0.90 < 40 0.98 UL, cUL 6 D8 RS
2 ES-296HO-1-TP 120 2.2 260 < 0.95 < 10 0.95 UL, cUL 5 D8 RS
2 ES-296HO-2-TP 277 0.94 254 < 0.95 < 10 0.95 UL, cUL 5 D8 RS
2 ES-296HO-3-TP 347 0.65 230 < 0.95 < 20 0.86 UL, cUL 5 D8 RS
MagneticBallast
FOR MORE INFORMATION CALL
1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A52Compact Fluoescent Lamps
MAGNETIC BALLASTS FOR
COMPACT FLUORESCENT LAMPS
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
% Replace –OC by –WC for With Cord model
+ Add –RJ for Recessed Downlight J-Box Mounting. See CASE H
ws This item is well stocked
Magnetic
Balla
sts
Lamp
Watts
Lamp
Type
No. of
Lamps
Cat.
Number
Input
Volts
Input
Current
Input
Watts
Power
Factor
THD
%
Ballast
FactorApprovals
Wiring
Dia.
Dimen
-sions
Staring
Method
5W CFT5W/G23
1 CF-49-OC-TP % 120 0.13 8 > 0.50 < 15 0.77 UL, cUL 2 A1 PH
1 CF-49-CC-TP ws % 120 0.13 8 > 0.50 < 15 0.77 UL, cUL 2 B1 PH
1 CF-49M-1-OC * 120 0.20 9.5 0.40 < 15 1.12 UL, cUL 2 A2 PH
1 CF-79-CC-TPws 120 0.15 9.1 0.50 15 0.80 UL, cUL 61 -- PH
7W CFT7W/G23
1 CF-49-OC-TP % 120 0.13 8 > 0.50 < 15 0.77 UL, cUL 2 A1 PH
1 CF-49-CC-TP ws % 120 0.13 8 > 0.50 < 15 0.77 UL, cUL 2 B1 PH
1 CF-49M-1-OC * 120 0.18 10.5 0.49 < 15 1.0 UL, cUL 2 A2 PH
1 CF-49M-1-CC * 120 0.18 10.5 0.49 < 15 1.0 UL, cUL 2 B2 PH
1 CF-79-CC-TPws 120 0.15 9.1 0.50 15 0.80 UL, cUL 61 -- PH
1 CF-579-CC-TP 120 0.15 9 > 0.50 < 15 0.87 UL, cUL 2 A1 PH
9W CFT9W/G23
1 CF-49-OC-TP % 120 0.15 8 > 0.50 < 15 0.77 UL, cUL 2 A1 PH
1 CF-49-CC-TP ws % 120 0.15 8 > 0.50 < 15 0.77 UL, cUL 2 B1 PH
1 CF-49M-1-OC * 120 0.15 1 > 0.50 < 15 0.90 UL, cUL 2 A2 PH
1 CF-49M-1-CC * 120 0.15 1 > 0.50 < 15 0.90 UL, cUL 2 B2 PH
1 CF-79-CC-TPws 120 0.15 9.1 0.50 15 0.80 UL, cUL 61 -- PH
1 CF-579-CC-TP 120 0.15 9 > 0.50 < 15 0.75 UL, cUL 2 B1 PH
13WCFT13W/GX23,
CFQ13W/GX23
1 CF-1322-OC-TP % 120 0.30 16 > 0.45 < 15 0.93 UL, CSA 2 A2 PH
1 CF-1322-CC-TP ws 120 0.30 16 > 0.45 < 15 0.93 UL, CSA 2 B2 PH
1 CF-1322M-OC-TP % 120 0.26 16 > 0.50 < 15 0.93 UL, CSA 2 A2 PH
1 CF-1322M-CC-TP ws 120 0.26 16 > 0.50 < 15 0.93 UL, CSA 2 B2 PH
1 CF-1322-WC-TP 120 0.26 16 > 0.50 < 15 0.90 UL, cUL 17 G2 PH
1 CF-1322-PG-TP 120 0.26 16 > 0.50 < 15 0.90 UL, cUL 17 E1 PH
1 CF-1320S-OC-TP % 120 0.26 16 > 0.50 < 20 0.90 UL, cUL 2 A4 PH
1 CF-1320S-CC-TP 120 0.26 16 > 0.50 < 20 0.90 UL, cUL 2 B4 PH
1 CF-13-HP-TP 120 0.13 15 > 0.90 < 10 0.88 UL, cUL 3 C3 PH
1 CF-13S-HP-TP + 120 0.13 15 > 0.90 < 10 0.88 UL, cUL 3 C7 PH
1 CF-13-2-OC-TP 277 0.27 20 0.25 < 10 1.0 UL, cUL 3 A3 PH
1 CF-13-2-CC-TP 277 0.27 20 0.25 < 10 1.0 UL, cUL 3 D3 PH
1 CF-13-2-HP-TP + 277 0.08 20 0.90 < 10 1.0 UL, cUL 3 D3 PH
2 CF-213S-HP-TP 120 0.25 30 > 0.95 < 30 0.90 UL, cUL 18 D3 PH
2 CF-213-2-TP 277 0.22 31 > 0.50 < 30 0.90 UL, cUL 24 D3 PH
2 CF-213-2-HP-TP 277 0.12 31 > 0.95 < 25 0.90 UL, cUL 23 D3 PH
A_Ballastspgs44-55_HID Ballasts.qxd 12-04-16 9:50 AM Page 9
MagneticBallast
Magnetic B
alla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
MAGNETIC BALLASTS FORCOMPACT FLUORESCENT LAMPS
Compact Fluoescent LampsA53
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
ApprovalsWiringDia.
Dimen-sions
StaringMethod
18W CFQ18W/G24d
1 CF-118-1-TP 120 0.35 21 > 0.50 < 30 0.87 UL, cUL 3 C6 PH
1 CF-118-1-HP-TP 120 0.18 21 > 0.95 < 30 0.87 UL, cUL 3 D1 PH
1 CF-118-2-OC-TP 277 0.24 24 > 0.35 < 30 0.90 UL, cUL 2 A3 PH
2 CF-218-1-HP-TP ws+ 120 0.42 45 > 0.90 < 15 0.87 UL, cUL 23 C1 PH
26W CFQ26W/G24d
1 CF-126-1-TP 120 0.59 32 > 0.45 < 15 0.85 UL, cUL 3 D1 PH
1 CF-126-1-HP-TP ws 120 0.28 32 > 0.95 < 30 0.89 UL, cUL 3 D1 PH
1 CF-126-2-OC-TP 277 0.28 31 > 0.40 < 15 0.91 UL, cUL 2 A3 PH
2 CF-226-1-HP-TP + 120 0.50 57 > 0.95 < 30 0.80 UL, cUL 23 C1 PH
27W CFQ27W/GX32d
1 CF-128-OC-TP 120 0.53 29 > 0.45 < 25 0.90 UL, cUL 2 A3 PH
1 CF-128-EN-TP 120 0.53 29 > 0.45 < 25 0.90 UL, cUL 2 D3 PH
1 CF-128-HP-TP 120 0.25 29 > 0.95 < 30 0.90 UL, cUL 3 D3 PH
% Replace –OC by –WC for With Cord model+ Add –RJ for Recessed Downlight J-Box Mounting. See CASE H
ws This item is well stocked
MagneticBallast
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
MAGNETIC BALLASTS FORCOMPACT FLUORESCENT LAMPS
Circline Lamps A54
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
ws This item is well stocked
Magnetic
Balla
sts
LampWatts
Lamp
Type
No. ofLamps
Cat.Number
InputVolts
InputCurrent
InputWatts
PowerFactor
THD%
BallastFactor
ApprovalsWiringDia.
Dimen-sions
StaringMethod
20W FC6T9
1 CF-1322-OC-TP 120 0.30 16 > 0.45 < 15 0.73 UL, cUL 7 A2 PH
1 CF-1322-CC-TP 120 0.30 16 > 0.45 < 15 0.73 UL, cUL 7 B2 PH
1 CF-22-WS-TP ws 120 0.35 21 > 0.50 < 20 0.79 UL, cUL 10 C7 PH
22W FC8T9
1 CF-22-WS-TP ws 120 0.29 19 > 0.50 < 15 0.79 UL, cUL 10 C7 PH
1 N-122-1-TP-WS 120 0.49 24 > 0.40 < 10 0.72 UL, cUL 10 D1 RS
1 CF-1540-1-TP-IES ws 120 0.35 21 > 0.50 < 30 0.82 UL, cUL 19 C7 IES
1 CF-1322-CC-TP 120 0.30 18 > 0.50 < 15 0.70 UL, cUL 7 B2 PH
1 CF-1322-CC-PF 120 0.30 18 > 0.50 < 15 0.70 UL, cUL 7 B2 PH
32W FC12T91 CF-1540-1-TP-IES ws 120 0.40 29 > 0.60 < 40 0.73 UL, cUL 19 C7 IES
1 N-140-1-TP-WS ws 120 0.58 32 > 0.40 < 15 0.64 UL, cUL 10 D1 RS
40W FC16T91 CF-1540-1-TP-IES ws 120 0.37 33 > 0.75 < 45 0.70 UL, cUL 19 D7 IES
1 N-140-1-TP-WS ws 120 0.52 33 > 0.50 < 15 0.58 UL, cUL 10 D1 RS
22&32WFC8T9 &FC12T9
2 N-2232-1-TP-WS 120 0.61 45 > 0.50 < 15 0.62 UL, cUL 11 C1 RS
2 ES-3240-1-TP-WS ws 120 0.44 51 > 0.95 < 20 0.72 UL, cUL 11 C1 RS
32&40WFC12T9 &FC16T9
2 N-3240-1-TP-WS 120 0.55 63 > 0.95 < 25 0.69 UL, cUL 11 C1 RS
2 ES-3240-1-TP-WS ws 120 0.56 66 > 0.95 < 25 0.72 UL, cUL 11 C1 RS
MagneticBallasts
Magnetic B
alla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
MAGNETIC BALLASTS
A55Sign Ballasts
ws This item is well stocked
No. ofLamps
Lamp FootageCat.
NumberInput
Volts/Hz
Max. LineCurrent(Amps)
Max. InputPower(Watts
OpenCircuitVolts)
Approvals Wiring Dia. Dimensions
Min Max
1,2 4 12 SB-0412-12-1-TP 120/60 1.48 175W 460V UL, cUL 5, 39 D8
2,3,4 6 20 SB-0620-24-1-TP 120/60 2.56 304W 600V UL, cUL 40, 41, 42 D8
2,3,4 12 24 SB-1224-24-1-TP 120/60 2.70 312W 765V UL, cUL 40, 41, 42 D9
2,3,4 20 40 SB-2040-24-1-TP 120/60 4.00 472W 720V UL, cUL 40, 41, 42 D10
4,5,6 12 40 SB-1240-46-1-TP 120/60 3.90 462W 720V UL, cUL 43, 44, 45 D10
4,5,6 24 48 SB-2448-46-1-TP 120/60 4.50 530W 720V UL, cUL 43, 44, 45 D10
Please see case styles on pages A66-A69 and wiring diagrams on pages A69-A73 & SUFFIX GUIDE on page A80
Etlin-Daniels reserves the right to discontinue, modify designs and change specifications without incurring obligation.
While every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct,
no warranty is given in respect thereof and the company shall not be liable for any error herein.
Copyright © 2011 Etlin-Daniels
EM
ER
GE
NC
Y B
ALLA
ST
S
A56
1850 Wilson Avenue, Toronto,Ontario, Canada, M9M 1A1
Ph: 416-741-7336 Fax: 416-741-9104www.etlin.com
SECTION A
BALLASTS
EMERGENCY BALLASTS
Elecrtronic Ballasts A1-A43Ballast Disconnects A42-A43Magnetic Ballasts A44-A55Emergency Ballasts for Linear Flourescent A56500 Lumens - Linear Flourescent Ballasts A57650 Lumens - Compact Flourescent Ballasts A58-61700 Lumens - Linear Flourescent Ballasts A62-A631300 Lumens A64Appendix - Wiring Diagrams & Case Styles A65-A73Appendix: Electronic Ballasts: Standard Lead Lengths & Standard Packaging A74-A79Suffix Guide A80
EmergencyBallast
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
EMERGENCY BALLASTS FORLINEAR FLUORESCENT LAMPS
A57EB-500 Linear Fluorescent Emergency Ballast—500 Lumens
Em
erg
ency B
alla
sts
The Etlin-Daniels EB-500 is a UL listed fluorescent lamp emergencyballast that allows the same fixture to be used for both normal andemergency modes. When the AC power fails the EB500 immediatelyswitches to the emergency mode and operates one of the existing lampsfor 90 minutes. When the power is restored, the unit automatically goesinto recharge mode and features a time delay to prevent false tripping atlamp end of life. The unit contains an internal long life maintenance freeNickel Cadmium battery, charger, and electronic inverter circuit in acompact metal case.
Dual input voltage: 120/277V, 60HzOperating temp: 0C to 55CIllumination time: 90 minutesInitial illumination: 1 lamp up to 500 lumensFor indoor applications.AC input power rating: 2.1 WattsCharging indicator light: LED.
Lamps operated: most 2' to 4' single Bipin T8-T12, Ubendor circline, Rapid or Instant start.Warranty: 3 years (see note below)Test Switch: included Open Circuit isolationWeight: 1.8 lbsApprovals: UL
Features and Benefits:
Average Lumen Rating of Lamps: Case Style & Dimension:
Lamp type and wattag 1 lamp
F17T8 450
F32T8 475
F20T12 425
F40T12 450
40W Biax 450
F40T12 Circline 450
The EB-500 does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If aswitched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast mustbe fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannotexceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB-500 is warranted for a period of 3 years from the date of purchase. This warranty covers only properly installedemergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair or replacewithout charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and our inspectiondetermines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser's exclusivewarranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minuterequirements.
EmergencyBallast
Em
erg
ency B
alla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
EMERGENCY BALLASTS FORCOMPACT FLUORESCENT LAMPS
A58EB-650C2-A Compact Fluorescent Emergency Ballast—650 Lumens
The Etlin-Daniels EB650C2-A is a UL listed fluorescent lamp emergencyballast that allows the same fixture to be used for both normal andemergency modes. When the AC power fails the EB-650C2-A immediatelyswitches to the emergency mode and operates one of the existinglamps for 90 minutes. When the power is restored the unit automaticallygoes into recharge mode and features a time delay to prevent false trippingat lamp end of life. The unit contains an internal long life maintenancefree Nickel Cadmium battery, charger, and electronic invertercircuit in a compact metal case. The EB-650C2-A can be used with most18 & 26 Watt quad tube 2-PIN LAMPS with an initial output of up to650 lumens. The EB-650C2-A provides dual 3/8" flexible conduits, onefor the fixture or ballast compartment and the other to the switch boxwhich includes the test switch, charge light, and unit battery connector.
Dual input voltage: 120/277V, 60HzOperating temp: 0C to 55CIllumination time: 90 minutesInitial illumination: 1 lamp up to 650 lumensFor indoor appications.AC input power rating: 2.5 WattsCharging indicator light: LED.
Lamps operated: most 18W and 26W quad tube CF2-PIN lamps with integral starter or circline, Rapid orInstant start.Warranty: 3 years (see note below)Test Switch: included Open Circuit isolationWeight: 3.2 lbsApprovals: UL
Features and Benefits:
Average Lumen Rating of Lamps: Case Style & Dimension:
Lamp type and wattag 1 lamp
18W PL CF 2-PIN 550
26W PL CF 2-PIN 650
The EB-650C2-A does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If aswitched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast mustbe fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannotexceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB650C2-A is warranted for a period of 3 years from the date of purchase. This warranty covers only properlyinstalled emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair orreplace without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and ourinspection determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser'sexclusive warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minuterequirements.
EmergencyBallast
Em
erg
ency B
alla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A59
EMERGENCY BALLASTS FORCOMPACT FLUORESCENT LAMPS
EB-650C2-B Compact Fluorescent Emergency Ballast—650 Lumens
The Etlin-Daniels EB650C2-B is a UL listed fluorescent lamp emergencyballast that allows the same fixture to be used for both normal andemergency modes. When the AC power fails the EB-650C2-B immediatelyswitches to the emergency mode and operates one of the existinglamps for 90 minutes. When the power is restored the unit automaticallygoes into recharge mode and features a time delay to prevent false trippingat lamp end of life. The unit contains an internal long life maintenancefree Nickel Cadmium battery, charger, and electronic invertercircuit in a compact metal case. The EB-650C2-B can be used with most18 & 26 Watt quad tube 2-PIN LAMPS with an initial output of up to650 lumens. The EB-650C2-B has leads and is designed to be hard wiredinto the fixture enclosure or wireway.
Dual input voltage: 120/277V, 60HzOperating temp: 0C to 55CIllumination time: 90 minutesInitial illumination: 1 lamp up to 650 lumensFor indoor appications.AC input power rating: 2.5 WattsCharging indicator light: LED.
Lamps operated: most 18W and 26W quad tube CF2-PIN lamps with integral starter Warranty: 3 years (see note below)Test Switch: included Open Circuit isolationWeight: 2.2 lbsApprovals: UL
Features and Benefits:
Average Lumen Rating of Lamps: Case Style & Dimension:
Lamp type and wattag 1 lamp
18W PL CF 2-PIN 550
26W PL CF 2-PIN 650
The EB-650C2-B-A does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If aswitched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast mustbe fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannotexceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB650C2-B is warranted for a period of 3 years from the date of purchase. This warranty covers only properlyinstalled emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair orreplace without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and ourinspection determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser'sexclusive warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minuterequirements.
EmergencyBallast
Em
erg
ency B
alla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A60
EMERGENCY BALLASTS FORCOMPACT FLUORESCENT LAMPS
EB-650C4-A Compact Fluorescent Emergency Ballast—650 Lumens
The Etlin-Daniels EB-650C4-A is a UL listed fluorescent lamp emergencyballast that allows the same fixture to be used for both normal andemergency modes. When the AC power fails the EB650C4-A immediatelyswitches to the emergency mode and operates one of the existinglamps for 90 minutes. When the power is restored the unit automaticallygoes into recharge mode and features a time delay to prevent false trippingat lamp end of life. The unit contains an internal long life maintenancefree Nickel Cadmium battery, charger, and electronic invertercircuit in a compact metal case. The EB-650C4-A can be used with most10 & 42 Watt triple, quad, twin tube 18 to 36W long tube CF 4-PINLAMPS with an initial output of up to 650 lumens. The EB-650C4-Aprovides dual 3/8" flexible conduits, one for the fixture or ballast compartmentand the other to the switch box which includes the test switch,charge light, and unit battery connector.
Dual input voltage: 120/277V, 60HzOperating temp: 0C to 55CIllumination time: 90 minutesInitial illumination: 1 lamp up to 650 lumens2 lamps up to 325 lumens.AC input power rating: 2.5 WattsCharging indicator light: LED.
Lamps operated: 1 lamp 10W-42W or 2 lamp 10W-26W CF 4-PINlamps, twin, quad or triple 2D and 18-36W Long Compact. Warranty: 3 years (see note below)Test Switch: included Open Circuit isolationWeight: 3.2 lbsApprovals: UL
Features and Benefits:
Average Lumen Rating of Lamps: Case Style & Dimension:
The EB-650C4-A does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If aswitched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast mustbe fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannotexceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB650C4-A is warranted for a period of 3 years from the date of purchase. This warranty covers only properlyinstalled emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair orreplace without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and ourinspection determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser'sexclusive warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minuterequirements.
Lamp type and wattag 1 lamp 2 lamp
13W PL CF 4-PIN 350 400
18W PL CF 4-PIN 350 550
26W PL CF 4-PIN 425 650
32W PL CF 4-PIN 600
42W PL CF 4-PIN 750
18W Long CF-PIN 500
18W Long CF-PIN 650
EmergencyBallast
Em
erg
ency B
alla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A61EB-650C4-B Compact Fluorescent Emergency Ballast—650 Lumens
EMERGENCY BALLASTS FORCOMPACT FLUORESCENT LAMPS
The Etlin-Daniels EB650C4-B is a UL listed fluorescent lamp emergencyballast that allows the same fixture to be used for both normaland emergency modes. When the AC power fails the EB650C4-Bimmediately switches to the emergency mode and operates one of theexisting lamps for 90 minutes. When the power is restored the unitautomatically goes into recharge mode and features a time delay toprevent false tripping at lamp end of life. The unit contains an internallong life maintenance free Nickel Cadmium battery, charger, and electronicinverter circuit in a compact metal case. The EB-650C4-B canbe used with most 13 & 42 Watt triple, quad, twin tube 18 to 36Wlong tube CF 4-PIN LAMPS with an initial output of up to 650 lumens.The EB650C4-B provides dual 3/8" flexible conduits, one forthe fixture or ballast compartment and the other to the switch boxwhich includes the test switch, charge light, and unit battery connector.
Dual input voltage: 120/277V, 60HzOperating temp: 0C to 55CIllumination time: 90 minutesInitial illumination: 1 lamp up to 650 lumens2 lamps up to 325 lumens.AC input power rating: 2.5 WattsCharging indicator light: LED.
Lamps operated: 1 lamp 13W-42W or 2 lamp 13W-26W CF 4-PIN lamps, twin, quad or triple 2D and 18-36W Long Compact. Warranty: 3 years (see note below)Test Switch: included Open Circuit isolationWeight: 2.5 lbsApprovals: UL
Features and Benefits:
Average Lumen Rating of Lamps: Case Style & Dimension:
The EB-650C4-B does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If aswitched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast mustbe fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannotexceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB-650C4-B is warranted for a period of 3 years from the date of purchase. This warranty covers only properlyinstalled emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair orreplace without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and ourinspection determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser'sexclusive warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minuterequirements.
Lamp type and wattag 1 lamp 2 lamp
13W PL CF 4-PIN 350 400
18W PL CF 4-PIN 350 550
26W PL CF 4-PIN 425 650
32W PL CF 4-PIN 600
42W PL CF 4-PIN 750
18W Long CF-PIN 500
18W Long CF-PIN 650
EmergencyBallast
Em
erg
ency B
alla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A62EB-700 Linear Fluorescent Emergency Ballast—700 Lumens
EMERGENCY BALLASTS FORLINEAR FLUORESCENT LAMPS
The Etlin-Daniels EB-700 is a UL listed fluorescent lamp emergencyballast that allows the same fixture to be used for both normal andemergency modes. When the AC power fails the EB-700 immediatelyswitches to the emergency mode and operates one of the existing lampsfor 90 minutes. When the power is restored the unit automatically goesinto recharge mode and features a time delay to prevent false tripping atlamp end of life. The unit contains an internal long life maintenance freeNickel Cadmium battery, charger, and electronic inverter circuit in acompact metal case.
Dual input voltage: 120/277V, 60HzOperating temp: 0C to 55CIllumination time: 90 minutesInitial illumination: 1 lamp up to 700 lumensFor indoor appications.AC input power rating: 2.3 WattsCharging indicator light: LED.
Lamps operated: most 2’ to 4’ single T8-T12, U-bendor circline, rapid or instant start.Warranty: 3 years (see note below)Test Switch: included Open Circuit isolationWeight: 2.3 lbsApprovals: UL
Features and Benefits:
Average Lumen Rating of Lamps: Case Style & Dimension:
Lamp type and wattag 1 lamp
F17T8 450
F32T8 700
F20T12 390
F40T12 660
F20T12 Circline 625
F40T12 Circline 650
The EB-700 does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If aswitched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast mustbe fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannotexceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB-700 is warranted for a period of 3 years from the date of purchase. This warranty covers only properly installedemergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair or replacewithout charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and our inspectiondetermines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser's exclusivewarranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minuterequirements.
EmergencyBallast
Em
erg
ency B
alla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A63EB-700-2 Linear Fluorescent Emergency Ballast—700 Lumens
EMERGENCY BALLASTS FORLINEAR FLUORESCENT LAMPS
The Etlin-Daniels EB-700-2 is a UL listed fluorescent lamp emergencyballast that allows the same fixture to be used for both normal andemergency modes. When the AC power fails the EB-700-2 immediatelyswitches to the emergency mode and operates one of the existing lampsfor 90 minutes. When the power is restored the unit automatically goesinto recharge mode and features a time delay to prevent false tripping atlamp end of life. The unit contains an internal long life maintenance freeNickel Cadmium battery, charger, and electronic inverter circuit in acompact metal case.
Dual input voltage: 120/277V, 60HzOperating temp: 0C to 55CIllumination time: 90 minutesInitial illumination: 1 lamp up to 700 lumens2 lamps 350 lumens each lampFor indoor appications.AC input power rating: 2.3 WattsCharging indicator light: LED.
Lamps operated: most 2’ to 8’ single or 2’ x 2’ to 4’bipin, T8-T12, HO, VHO U bend or circline, rapid orinstant startWarranty: 3 years (see note below)Test Switch: included Open Circuit isolationWeight: 2.1 lbsApprovals: UL
Features and Benefits:
Average Lumen Rating of Lamps: Case Style & Dimension:
The EB-700-2 does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If aswitched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast mustbe fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannotexceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB-700-2 is warranted for a period of 3 years from the date of purchase. This warranty covers only properlyinstalled emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair orreplace without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and ourinspection determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser'sexclusive warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minuterequirements.
Lamp type and wattag 1 lamp 2 lamp
F17T8 450 650
F32T8 700 675
8’ T8 FO96 or 59W 675
F20T12 390 650
F40T12 660 650
8’ T12 F96T12 60W 650
40W Biax 600
55W Biax 650
F40T12 Circline 650
EmergencyBallast
Em
erg
ency B
alla
sts
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
A64EB-1300 Linear Fluorescent Emergency Ballast—1300 Lumens
EMERGENCY BALLASTS FORLINEAR FLUORESCENT LAMPS
The Etlin-Daniels EB-1300 is a UL listed fluorescent lamp emergencyballast that allows the same fixture to be used for both normal andemergency modes. When the AC power fails the EB-1300 immediatelyswitches to the emergency mode and operates one of the existing lampsfor 90 minutes. When the power is restored the unit automatically goesinto recharge mode and features a time delay to prevent false tripping atlamp end of life. The unit contains an internal long life maintenance freeNickel Cadmium battery, charger, and electronic inverter circuit in acompact metal case.
Dual input voltage: 120/277V, 60HzOperating temp: 0C to 55CIllumination time: 90 minutesInitial illumination: 1 lamp up to 1300 lumens2 lamps 650 lumens each lampFor indoor appications.AC input power rating: 2.9 WattsCharging indicator light: LED.
Lamps operated: most 2’ to 8’ single or 2’ x 2’ to 4’bipin, T8-T12, HO, VHO U bend or circline, rapid orinstant start.Warranty: 3 years (see note below)Test Switch: included Open Circuit isolationWeight: 3.1 lbsApprovals: UL
Features and Benefits:
Average Lumen Rating of Lamps: Case Style & Dimension:
The EB-1300 does not affect the normal fixture operation and may be used with either a switched or unswitched fixture. If aswitched fixture is used then the unswitched hot lead must be connected to the emergency ballast. The emergency ballast mustbe fed by the same branch circuit as the AC ballast. When battery packs are remotely mounted, the remote distance cannotexceed 1/2 the distance to the lamp as the AC ballast manufacturer recommends. The maximum allowable remote distance is 50feet from the lamp, or whichever is less. Not recommended for use where the ambient temperature may fall below 0C.
Warranty - The EB-1300 is warranted for a period of 3 years from the date of purchase. This warranty covers only properlyinstalled emergency ballasts used under normal circumstances. For the warranty period Etlin-Daniels will, at its option, repair orreplace without charge a defective emergency ballast, provided it is returned to the factory, transportation prepaid and ourinspection determines it to be defective under the terms of the warranty. Repair or replacement shall constitute the purchaser'sexclusive warranty, which does not extend to transportation, installation, labor or any other charges.
Meets or exceeds the National Electrical Code (NEC) and Life Safety Code Emergency Lighting Requirements, UL 90 minuterequirements.
Lamp type and wattag 1 lamp 2 lamp
F17T8 1125 1100
F32T8 1350 1350
8’ T8 FO96 or 59W 1300
F20T12 680
F40T12 1150
8’ T12 F96T12 60W 1125
40W Biax 1050
55W Biax 1100
F40T12 Circline 1125
Etlin-Daniels reserves the right to discontinue, modify designs and change specifications without incurring obligation.
While every effort is made to ensure that descriptions, specifications and other information in this catalogue are correct,
no warranty is given in respect thereof and the company shall not be liable for any error herein.
Copyright © 2011 Etlin-Daniels
1850 Wilson Avenue, Toronto,Ontario, Canada, M9M 1A1
Ph: 416-741-7336 Fax: 416-741-9104www.etlin.com
SECTION A
BALLASTS
APPENDIX &
SUFFIX GUIDE
Elecrtronic Ballasts A1-A41Ballast Disconnect A42-A43Magnetic Ballasts A44-A55Emergency Ballasts A56-A64Appendix: Wiring Diagrams & Case Styles A65-A73
Appendix: Electonic Ballasts: Standard Lead Lengths & Standard Packaging A74-A79
Appendix: Wiring Diagrams & Case StylesSuffix Guide A80
AP
PE
ND
IX &
SU
FF
IX G
UID
E
A65
AppendixA
ppendix
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
WIRING DIAGRAMS
A66
Case FCase D Case E
Case C
Case A
Case B
Case KCase G Case J
CASE STYLE
DIMENSION IN INCHES
LENGTH WIDTH(W)
HEIGHT(H)(M) (L)
A 1 2.00 2.36 1.10 1.42
A 2 2.50 3.11 1.85 1.34
A 3 2.80 3.27 1.54 1.97
A 4 2.00 2.36 1.18 1.42
B 1 2.50 2.75 1.50 1.20
B 2 2.75 3.15 1.73 1.30
B 3 2.00 2.36 1.41 1.40
B 4 2.75 3.15 1.50 1.30
C 1 6.00 6.61 2.36 1.57
C 2 9.00 9.49 2.40 1.61
C 3 3.75 4.02 1.93 1.50
C 4 9.00 9.49 2.28 1.57
C 6 6.00 6.46 1.89 0.96
C 7 2.75 3.10 1.89 1.43
D 1 8.00 6.46 1.089 1.42
D 2 11.00 11.65 3.15 1.85
D 3 4.33 4.76 2.17 1.57
D 4 9.00 9.45 3.15 1.85
D 5 2.80 3.15 1.48 1.14
D 6 3.15 3.45 1.80 1.20
D 7 9.00 9.49 1.65 1.15
D 8 11 11.70 3.15 2.50
D 9 13.75 14.31 3.19 2.60
D 10 18.63 19.19 3.19 2.63
E 1 -- 1.89 2.26 2.99
E 2 -- 1.61 1.97 2.36
E 3 -- 1.54 2.00 2.87
E 4 -- 1.77 1.89 2.56
F 1 -- 2.48 1.48 1.06
F 2 -- 2.28 1.30 0.79
F 3 -- 2.68 1.30 0.79
F 4 -- 2.09 1.30 0.79
J 1 6.00 6.46 1.89 0.98
G 1 6.00 6.46 1.89 1.42
G 2 -- 2.48 1.89 1.34
K 5.37 5.50 1.89 1.75
Case Styles and Dimensions
AppendixA
ppendix
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
CASE STYLES
A67
Case ZCase X Case Y
Case WCase U Case V
Case TCase P Case S
Case NCase L Case M
Case Styles and Dimensions
CASESTYLE
DIMENSION IN INCHES
LENGTH WIDTH(W)
HEIGHT(H)(M) (L)
L1 6.00 6.46 1.89 1.00
L2 6.00 6.46 1.89 1.15
L3 8.90 9.45 1.80 1.37
L4 8.90 9.45 1.15 1.26
L5 8.90 9.50 1.70 1.15
L6 8.90 9.50 1.38 1.18
L7 6.00 6.46 1.37 1.00
L8 3.60 4.00 1.87 1.18
M1 6.00 6.46 1.37 1.00
N1 8.75 9.00 0.95 0.95
N2 7.25 7.50 0.95 0.95
N3 9.00 9.60 1.16 0.88
P1 8.75 9.00 0.95 0.95
P2 7.25 7.50 0.95 0.95
CASESTYLE
DIMENSION IN INCHES
LENGTH WIDTH(W)
HEIGHT(H)(M) (L)
S1 3.12 3.45 1.81 1.21
S2 3.12 3.45 2.91 1.21
T1 4.63 5.0 2.40 1.00
T2 4.63 5.0 3.00 1.38
U1 14.00 14.40 1.23 1.03
U2 6.00 6.46 1.28 0.95
U3 8.75 9.00 0.95 0.95
U4 16.34 16.7 1.18 1.00
V1 5.60 5.90 0.91 0.76
W1 4.63 5.0 2.40 1.00
W2 4.63 5.0 3.00 1.38
X1 2.80 3.07 1.16 1.00
Y1 0.90 -- 1.54 0.97
Z1 2.0 2.48 1.38 0.83
AppendixA
ppendix
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
CASE STYLES
A68Case Styles and Dimensions
FIG. 7FIG. 5 FIG. 6
FIG. 3FIG. 1 FIG. 2
FIG. 8
FIG. 4
Dimension in inches Leads or Term BlkFigure
OUR No. L W H M Wired from
AA1 11.8 2.15 1.61 11 SIDE WIRE FIG. 11 (NEXT PAGE)
AA2 11.5 1.34 1.06 11.14 TOP TERM BLK FIG. 1
AA3 9.5 2.32 1.46 8.9 SIDE WIRE FIG. 2
AA4 12.8 1.34 1.14 12.5 TOP TERM BLK FIG. 1
AA5 17.71 1.7 1.14 17.24 TOP TERM BLK FIG. 1
AA6 12.8 1.34 1.14 12.5 TOP TERM BLK FIG. 1
AA15 5.36 2.48 1.18 4.84 SIDE TERM BLK FIG. 4
AA16 5.36 2.48 1.18 4.84 BOTTOM STUD FIG. 5
AA16 5.2 2.48 1.18 4.84 BOTTOM STUD FIG. 5
AA17 4.9 2.5 1.14 4.48 BOTTOM FEED NO STUD FIG. 3
AA23 6.5 1.9 1.14 5.9 BOTTOM STUD FIG. 5
AA24 5 2.48 1.18 4.4 BOTTOM STUD FIG. 5
AA18 4.9 2.5 1.14 4.48 BOTTOM STUD FIG. 5
AA19 6.55 2.9 1.18 5.9 SIDE TERM BLKA FIG. 4
AA20 6.55 2.9 1.18 5.9 BOTTOM STUD FIG. 5
AA21 5 3 1.34 4.6 BOTTOM STUD FIG. 3
AA22 17.71 1.7 1.14 17.24 SIDE WIRE FIG. 6
AA25 7.8 3.1 1.4 7.3 BOTTOM STUD FIG. 8
AA26 7.8 3.1 1.4 7.3 SIDE TERM BLK FIG. 4
AA27 9.5 2.3 1.57 8.9 SIDE WIRE FIG. 7
AA28 17.71 1.7 1.14 17.24 SIDE WIRE FIG. 1
AA29 9.5 2.32 1.46 8.9 SIDE WIRE FIG. 9 (NEXT PAGE)
AB1 4.11 1.38 1.10 3.62 FIG. 10 (NEXT PAGE)
AC1 4.17 -- 1.87 1.06 FIG. 11 (NEXT PAGE)
AppendixA
ppendix
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
CASE STYLES AND WIRING DIAGRAMS
A69
Wiring Diagrams Fig. 1-9
FIG. 3FIG. 1 FIG. 2
FIG. 6FIG. 4 FIG. 5
FIG. 9FIG. 7 FIG. 8
Case Styles and Dimensions
FIG. 11FIG. 9 FIG. 10
AppendixA
ppendix
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
WIRING DIAGRAMS
A70
FIG. 12FIG. 10 FIG. 11
FIG. 15FIG. 13 FIG. 14
FIG. 18FIG. 16 FIG. 17
FIG. 21FIG. 19 FIG. 20
Wiring Diagrams Fig. 10-24
FIG. 24FIG. 22 FIG. 23
FIG. 27FIG. 25 FIG. 26
FIG. 30FIG. 28 FIG. 29
FIG. 33FIG. 31 FIG. 32
FIG. 36FIG. 34 FIG. 35
Appendix
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
WIRING DIAGRAMS
A71Wiring Diagrams Fig. 25-36
Appendix
AppendixA
ppendix
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
WIRING DIAGRAMS
A72Wiring Diagrams Fig. 37-48
FIG. 39FIG. 37 FIG. 38
FIG. 42FIG. 40 FIG. 41
FIG. 45FIG. 43 FIG. 44
FIG. 48FIG. 46 FIG. 47
AppendixA
ppendix
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
WIRING DIAGRAMS
A73Wiring Diagrams Fig. 49-58
FIG. 51FIG. 49 FIG. 50
FIG. 54FIG. 52 FIG. 53
FIG. 57FIG. 55 FIG. 56
FIG. 60
FIG. 58 FIG. 59 FIG. 61
A_Ballastspgs65-80_HID Ballasts.qxd 12-04-16 10:03 AM Page 9
AppendixA
ppendix
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLASTS - STANDARD LEAD LENGTH
A74Energy Saving (ES) Series
Normal Power Factor (N) Series
Compact Fluorescent (CF) Series
CAT. NO. OPTION RED YELLOW BLUE WHITE BLACK
ES-140-*-TP Standard 34” x 34” --- 26” X 26” 22” 22”
ES-240-*-TPES-232-*-TPLW-240-1-TPLE-240-1-TP
Standard 26” X 26” 37” X 37” 26” X 26” 22” 22”
ES-296-1-TPES-275-1-TP
Standard 48” --- 48” 72” 72”
ES-196-*-TP Standard --- --- 48” 72” 72”
ES-296-2-TP Standard 48” 72” X 72” 48” 72” 72”
ES-196HO-*-TP Standard 48” X 48” --- 72” X 72” 22” 22”
ES-296HO-*-TP Standard 48” X 48” 72” X 72” 48” X 48” 22” 22”
CAT. NO. OPTION RED YELLOW BLUE WHITE BLACK
N-140-1-TPStandardStyle 1
32” x32”30” x30”
------
19”30”
30”30
14”14”
N-120-1-TPStandardStyle 1
16” x 16”15” x 15”
------
20”18”
19”24”
12”12”
N-240-1-TPN-234-1-TP
Standard 12” X 12” 36” X 36” 12” X 12” 18” 18”
N-220-1-TP Standard 15” X 15” 23” X 23” 15” x 15” 12” 12”
N-113A-1-TP Standard --- --- 16” 16” 16”
N-113-1-TP-IES Standard 16” X 16” 16” --- --- 16”
N-213-1-TP-IES Standard 16” X 16” 16” X 16” 16” X 16” --- 16”
All ballast for circlinewith socket
StandardSocket Assembles are 9” from the side
of the ballast case12” 12”
CAT. NO. OPTION BLACK
CF-1322 SeriesCF-1320S SeriesCF-1322M SeriesCF-49 and CF-570 Series
StandardStyle 1Style 2Style 3
9” x 18”7” x 15”6” x 12”12” x 12”
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Energy Ballast (EB) Series
CAT. NO. OPTION BLUE YELLOW RED WHITE BLACK
T5 Straight Lamp
EB-113-1-TPEB-113-1-TP-MCEB-113-1-TP-SLEB-113-1-TP-SL-MCEB-113-1-TP-SLLEB-113-1-TP-SLL-MCEB-208-1-TPEB-208-1-TP-MCEB-208-1-TP-SLEB-208-1-TP-SL-MC
18” x 18” --- 18” x 18” 18” 18”
EB-213-1-TPEB-213-1-TP-MCEB-213-1-TP-SLEB-213-1-TP-SL-MC
24” --- 24” 18” 18”
T8 Straight Lamp
EB-132-1-TP-PICEB-132-UV-TP-PIC
32” --- 48” 20” 20”
EB-2C72-1-TPEB-132-UV-TP-SLEB-232-UV-TP-SL
32” x 32” --- 48” x 48” 20” 20”
EB-232-1-TP-PICEB-232-UV-TP-PICEB-232SL-1-TPEB-232SL-2-TPEB-232SL-3-TPEB-232RIS-1-TP
32” x 32” --- 48” 20” 20”
EB-332-1-TP-PICEB-332-UV-TP-PICEB-332-1-TPEB-332-2-TP
32” x 32” x 32” --- 48” 20” 20”
EB-432-1-TP-PICEB-432-UV-TP-PICEB-432-1-TPEB-432-2-TPEB-432RIS-1-TP
32” x 32” 48” x 48” 32” x 32” 20” 20”
Compact LampEB-113-1-TP-PNEB-1C22-1-TPEB-1C22-1-TP-LCEB-126-1-TPEB-218-1-TPEB-226-1-TP
9” --- 9” 12” 12”
Circline LampEB-1C22-1-TP-WSEB-1C22-1-TP-WS-LCEB-1C3032-1-TP-WSEB-1C3032-1-TP-WS-LC
EB-2C72-1-TP-WS
9” --- 9” 12” 12”
2D Lamp
EB-1382D-1-TP 18” --- 18” 12” 12”
APPENDIXA
ppendix
A75
ELECTRONIC BALLASTS - STANDARD LEAD LENGTH
Models with 9 inch Long Can
Models with 11 inch Long Can
ES-296-1-TP, ES-296N-1-TP, ES-296-2-TP, ES-275-1-TP
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
BULK PACK 5184 18 288 --- 107 X 90 X 41 1037 --- ---
6 PCS PACK 5148 22 234 39 107 X 90 X 41 845 6 36 X 31 X 10
IND. BOXED 5184 18 288 48 107 X 90 X 63 1037 6 36 X 31 X 10
ES-196HO-*-TP ES-296HO-*-TP
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
BULK PACK 3780 21 180 --- 107 X 90 X 41 858 --- ---
4 PCS PACK 3872 22 176 44 107 X 90 X 41 863 4 30 x 20 x 15
IND. BOXED 3872 22 176 44 107 X 90 X 63 840 4 31.5 x 21.5 x 16.5
ES-140 Series, ES-140N Series, ES-240 Series, ES-240N Series, ES-232 Series
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
BULK PACK 11500 23 500 --- 107 X 90 X 41 765 --- ---
10 PCS PACK 11500 22 540 54 107 X 90 X 51 825 10 37 X 26 X 9
IND. BOXED 11500 24 450 48 107 X 90 X 63 735 10 42 X 26 X 10
Appendix
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLASTS - STANDARDPACKAGING
A76
APPENDIX
APPENDIXA
ppendix
A77
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
Electronic Ballast (EB) Series
CAT. NO.
CARTON PALLET 20" CONTAINER
DIMENSIONS /mm
NO. OFUNIT
DIMENSIONS /mm
NO. OFCTN
NO. OFUNIT
WEIGHTNO. OFPALLET
NO. OFUNIT
EB-113-1-TP 370X245X205 40 1200X1000X950 48 1920 623 16 30720
EB-113-1-TP-MC 370X245X205 40 1200X1000X950 48 1920 657 16 30720
EB-113-1-TP-SL 370X245X205 50 1200X1000X950 48 2400 672 16 38400
EB-113-1-TP-SL-MC 370X245X205 50 1200X1000X950 48 2400 705 16 38400
EB-113-1-TP-SLL 370X245X205 50 1200X1000X950 48 2400 672 16 38400
EB-113-1-TP-SLL-MC 370X245X205 50 1200X1000X950 48 2400 705 16 38400
EB-113-1-TP-PN 470X265X210 100 1200X1000X970 32 3200 617 16 51200
EB-208-1-TP 370X245X205 40 1200X1000X950 48 1920 705 16 30720
EB-208-1-TP-MC 370X245X205 40 1200X1000X950 48 1920 730 16 30720
EB-208-1-TP-SL 370X245X205 50 1200X1000X950 48 2400 748 16 38400
EB-208-1-TP-SL-MC 370X245X205 50 1200X1000X950 48 2400 768 16 38400
EB-213-1-TP 370X245X205 40 1200X1000X950 48 1920 720 16 30720
EB-213-1-TP-MC 370X245X205 40 1200X1000X950 48 1920 748 16 30720
EB-213-1-TP-SL 370X245X205 50 1200X1000X950 48 2400 792 16 38400
EB-213-1-TP-SL-MC 370X245X205 50 1200X1000X950 48 2400 825 16 38400
EB-IC22-1-TP 470X265X210 100 1200X1000X970 32 3200 553 16 51200
EB-IC22-1-TP-WS 470X265X210 100 1200X1000X970 32 3200 570 16 51200
EB-IC22-1-TP-LC 330X270X210 48 1200X1000X960 48 2304 705 16 36864
EB-IC22-1-TP-WS-LC 330X270X210 48 1200X1000X960 48 2304 705 16 36864
EB-IC3032-1-TP-WS 470X265X210 100 1200X1000X970 32 3200 570 16 51200
EB-IC3032-1-TP-WS-LC 330X270X210 36 1200X1000X960 48 1728 576 16 27648
EB-2C72-1-TP 330X270X210 36 1200X1000X960 48 1728 680 16 27648
EB-2C72-1-TP-WS 330X270X210 36 1200X1000X960 48 1728 705 16 27648
EB-126-1-TP 470X265X210 100 1200X1000X970 32 3200 553 16 51200
EB-218-1-TP 330X270X210 36 1200X1000X960 48 1728 680 16 27648
EB-226-1-TP 330X270X210 36 1200X1000X960 48 1728 680 16 27648
EB-1382D-1-TP 470X265X210 100 1200X1000X970 32 3200 617 16 51200
EB-132-UV-TP-SL370X245X205 35 1200X1000X950 48 1680 920 16 26880
EB-232-UV-TP-SL
EB-132-1-TP-PIC
370X245X205 30 1200X1000X950 48 1440 1160 15 21600
EB-232-1-TP-PIC
EB-332-1-TP-PIC
EB-432-1-TP-PIC
EB-132-UV-TP-PIC
EB-232-UV-TP-PIC
EB-332-UV-TP-PIC
EB-432-UV-TP-PIC
EB-232R-1-TP
270X275X330 30 1120X960X760 20 600 520 28 16800
EB-232R-2-TP
EB-232R-3-TP
EB-232SL-1-TP
EB-232SL-2-TP
EB-232SL-3-TP
EB-332-1-TP
390X260X120 10 1100X950X600 49 490 590 30 14700EB-332-2-TP
EB-432-1-TP
EB-432-2-TP
ELECTRONIC BALLASTS - STANDARDPACKAGING
APPENDIXA
ppendix
A78
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLASTS - STANDARDPACKAGING
Models with 6 inch Long Can & CF Series
N-120-1-TP, N-140-1-TP, NPF T8 Series, CF-118-1, CF-126-1 Series
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
BULK PACK 19090 29 830 --- 107 X 90 X 36 782 --- ---
30 PCS PACK 19090 22 900 30 107 X 90 X 36 847 30 35 X 18 X 18
IND. BOXED 17856 24 744 93 107 X 90 X 51 703 8 19 X 14 X 18
N-113-1-TP-IES, N-213-1-TP-IES, N-113A Series, N-117-1-TP, CF-118-1-TP
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
30 PCS PACK 32400 24 1350 45 107 X 90 X 36 660 30 35 x 17 x 13
N-220-1-TP, CF-218-1-HP-TP, CF-226-1-HP-TP
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
BULK PACK 15600 24 650 --- 107 X 90 X 40 743 --- ---
30 PCS PACK 15600 20 780 39 107 X 90 X 51 888 20 35 x 18 x 16
N-240-1-TP, N234-1-TP
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
BULK PACK 19040 17 1120 --- 90 x 70 x 31 1010 --- ---
CF-579 Series
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
72 PCS PACK 80640 14 5760 80 100 X 78 X 88 1080 72 38 X 24 X 9
CF-1322 Series
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
50 PCS PACK 56000 14 4000 80 100 X 78 X 88 1255 50 38 X 24 X 9
CF-1320S-CC Series
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
60 PCS PACK 67200 14 4800 60 100 X 78 X 88 1047 60 38 X 24 X 8.5
CF-1320S-OC Series
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
60 PCS PACK 84000 14 6000 60 100 X 78 X 88 1125 60 38 X 17.5 X 8.5
CF-13-HP-TP
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
50 PCS PACK 42000 14 3000 60 100 X 78 X 88 1215 50 50 X 24 X 9
APPENDIXA
ppandix
A79
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)
ELECTRONIC BALLASTS - STANDARDPACKAGING
Circline Ballasts
CF-22-WS-TP
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
48 PCS PACK 46080 24 1920 40 750 48 ---
N-122-1-TP-WS, N-140-1-TP-WS
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
BULK PACK 18260 22 830 --- 107 X 90 X 36 810 --- ---
20 PCS PACK 17600 22 800 40 107 X 90 X 40 762 20 48 X 20 X 8
IND. BOXED 17856 24 744 93 107 X 90 X 51 729 8 19 X 14 X 18
N-2232-1-TP-WS
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
BULK PACK 14950 23 650 --- 107 X 90 X 41 762 --- ---
10 PCS PACK 14700 21 700 70 107 X 90 X 41 815 10 30 X 21 X 8
IND. BOXED 16560 23 720 120 107 X 90 X 63 843 6 19 X 14 X 18
N-3240-1-TP-WS, ES-3240-1-TP-WS
STYLE20’ Container Pallet Information CARTON
QTY / pcs PALLET QTY / pcs CARTON SIZE / cm WEIGHT /kgs QTY / pcs SIZE / cm
BULK PACK 14300 22 650 --- 107 X 90 X 41 810 --- ---
Suffix GuideS
uffix
Guid
e
SUFFIX GUIDE
A80
INPUT LINE VOLTAGE277V INPUT LINE VOLTAGE347V INPUT LINE VOLTAGE480V INPUT LINE VOLTAGEAluminum Primary Winding, Aluminum Secondary WindingADAPTERALUMINUM CASECopper Primary Winding, Aluminum Secondary WindingCLAMP COREDOUBLE TAP INPUT VOLTAGE (120V, 277V)DIMMABLEDUAL WAY CONNECTORBF = 0.77COMPLY WITH FCC CLASS B REQUIREMENTENCASEDFINGER CANBF = 1.88HIGH POWER FACTOR120V OUTPUT VOLTAGEINTERNAL ELECTRONIC STARTERINTERNATIONAL VOLTAGE (90V-240V)BF = 0.88LARGE CANLOCAL DIMMABLEWITH LEAD WIRELOW HEATWITH MOUNTING CUPOPEN CORE5 TAP INPUT VOLTAGE (120V, 208V, 240V, 277V, 480V)WITH SINGLE BLOW THERMAL FUSEPLUG-INPLASTIC ENCASEDACTIVE POWER FACTOR CORRECTIONPRE-HEAT STARTPROGRAMMED STARTPROGRAMMED START & DUAL WAY CONNECTORRECESSED JUNCTION BOX WITHOUT BOTTOM STUDRECESSED JUNCTION BOX WITH BOTTOM STUDQUAD TAP INPUT VOLTAGE (120V, 208V, 240V, 277V)QUAD TAP INPUT VOLTAGE (120V, 208V, 240V, 347V)SHORT CIRCUIT PROTECTIONSHORT CAN WITH BOTTOM STUDSSHORT CAN WITHOUT BOTTOM STUDSSLIM CANLONG SLIM CANSELF-STARTCLASS P BALLASTUNIVERSAL LINE INPUT VOLTAGE (120V-277V)WITH CORDWITH CIRCLINE SOCKET
-1-2-3-4-AA-AD-AL-CA-CC-D-DIM-DW-EBF-EMI-EN-FC-HBF-HP-HV-IES-IV-LBF-LC-LDIM-LS-LH-MC-OC-P-PF-PG-PN-PIC-PH-PS-PSD-RJ-RJS-Q-Q3-SCP-SCS-SC-SL-SLL-SS-TP-UV-WC-WS
Suffix Guide
FOR MORE INFORMATION CALL1-800-661-9610 (Canada) 1-888-762-5384 (USA)