etics - paneltor.com®-etics... · special panels: turns, jambs, lintels, etc. autolimpiante y...

16
INSULATION ALL-IN-ONE MANUAL PANELES UHPC CON AISLAMIENTO INCORPORADO. SISTEMA MONOBLOCK UHPC PANELS WITH BUILT-IN INSULATION. MONOBLOCK SYSTEM SATE / ETICS COMPACT INDOOR OUTDOOR P A T E N T A D O P A T E N T E D

Upload: others

Post on 10-Jul-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

SATE / ETICS | COM

PACT 1

INSULATION ALL-IN-ONE

MANUAL

PANELES UHPC CON AISLAMIENTO INCORPORADO. SISTEMA MONOBLOCK

UHPC PANELS WITH BUILT-IN INSULATION. MONOBLOCK SYSTEM

SATE / ETICSCOMPACT INDOOR

OUTDOOR

P

AT E N T A D

O

PATENTED

Page 2: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

SATE / ETICS | COM

PACT 2

Paneles compuestos de una lámina de PANELTOR® hormigón UHPC de 5mm fundida con una plancha de aislamiento de poliuretano extruido de alta densidad de espesor variable, con dimensiones estándar de 2520 x 1220 mm y 1270 x 620mm con un peso de ± 12 kgs./m².

PANELTOR® SATE/COMPACT puede tener diversos acabados en su cara vista, así como diferentes tonalidades mediante la pigmentación de su mortero o aplicación de una veladura con un determinado RAL.

La fijación de los paneles SATE/COMPACT de PANELTOR® se realización mediante anclajes mecánicos a la lámina de PANELTOR®, conforme al siguiente detalle:

Todo esto hace de PANELTOR® SATE/COMPACT un panel único, que aportar una solución prefabricada de aislamiento térmico de los edificios, conforme a la ETAG 17 de la Organización Europea de Aprobaciones Técnicas con base en la Directiva 89/106/EEC relativa a la aproximación de las disposiciones legales, reglamentarias y administrativas de los Estados miembros sobre los productos de construcción.

Panels made up of a 5mm UHPC PANELTOR® concrete sheet cast with a variable thickness extruded polyurethane insulation sheet, with standard dimensions of 99 x 48 in and 50 x 24 in with a weight of ± 26,45 lb/m².

PANELTOR® ETICS/COMPACT can have different finishes on its visible side, as well as different tones by pigmenting its mortar or applying a glaze with a certain RAL.

The PANELTOR® ETICS/COMPACT panels are fixed by means of mechanical anchors to the PANELTOR® sheet, in accordance with the following detail:

All this makes PANELTOR® ETICS/COMPACT a unique panel, which provides a prefabricated solution for thermal insulation of buildings, in accordance with ETAG 17 of the European Organisation for Technical Approvals based on Directive 89/106/EEC on the approximation of the laws, regulations and administrative provisions of the Member States concerning construction products.

Energetic 25-40% reduction

Thermal insulation

Acoustic comfort since +2dBA

No water condensation

Waterproof building

Reducción energética 25-40%

Aislante térmico

Confort acústico hasta +2dBA

Sin condensación de agua

Impermeabilidad del edificio

PROTECCIÓN AISLANTE | EXCELLENT ISOLATION

SATE / ETICSCOMPACT INDOOR

OUTDOOR

Aplicación directaDirect application

Resistencia al fuegoFire resistance

AntifúngicoAntifungal

Reducción 25-40%Reduction 25-40%

Confort acústicoAcoustic comfort

PAT E N T A D

O

PATENTED

Page 3: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

SATE / ETICS | COM

PACT 3

Conducciones ocultasHidden conductions

Grietas ocultasHidden cracks and crevices

Doble paredDouble wall

REHABILITACIÓN | REHABILITATION

Aplicación directa sin residuosDirect application without waste

Aplicación directa sin residuosDirect application without waste

Hormigón de alta resistenciaUltra high performance concrete

VENTAJAS | ADVANTAGES

Paneles ligeros >55mmLight panels >55mm

Paneles con acabado de hormigónPanel with concrete finish

Piezas especiales: curvas, vueltas, jambas, etc.Special panels: turns, jambs, lintels, etc.

Autolimpiante y descontaminanteSelf-cleaning and antipollution

Paneles reparables y reemplazablesReparable and replaceable panels

Paneles geométricos: hexágono, triángulo, etc.Geometrical shapes: hexagons, riangles, etc.

Protección solar conpanel perforado o baguetteSolar shading with perforated panel or baguette

AntifúngicoAntifungal

PANELTOR® ETICS/SATE | TECHNICAL INFORMATION

Bending strenghtResistencia a la flexión 16N / mm2

UNE 196-1:2018

Weight per m2Peso por m2+/- 12kg. Panel 2500x1200

+/- 26,45lb. Panel 98 x 47 in

Compression strenghtResistencia a la compresión 153 Q [kN]UNE 196-1:2018

Expansion coefficientCoeficiente de dilatación 7 y 12 x 10- 6 K-1UNE 196-1:2018

ImpermeabilityImpermeabilidad CATEGORÍA AUNE 12467:2013+A1 2017

Impact strenghtResistencia al impactoUNE 127748-2:2012

Frost resistanceResistencia a la heladaUNE 12467:2013+A1 2017

Thermal resistanceResistencia térmica

CATEGORÍA AUNE-EN 12667:2002

Thermal conductivityConductividad térmicaλ = 0,70 W/m·KUNE-EN 12667:2002DIN 52.612 | ASTM C-518

Fire resistance: polystyrene XPS

Poliestireno XPSPolystyrene XPS

Resistencia al fuego: poliestireno XPS

CLASE B-s1,d0FL

UNE-EN 13823:2010 +A1:2016UNE-EN 1350-1:2007+A1:2010

35 0,94 m2 K / W45 1,20 m2 K / W55 1,50 m2 K / W65 1,80 m2 K / W75 2,00 m2 K / W85 2,25 m2 K / W95 2,55 m2 K / W105 2,85 m2 K / W125 3,35 m2 K / W

Page 4: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

SUPERFICIE DE COLOCACIÓNFIXING SURFACE

El sistema de aislamiento monoblock para exterior PANELTOR® SATE y el sistema de aislamiento monoblock para interior PANELTOR® COMPACT implican la colocación de una serie de paneles y anclajes.

Para la lograr un aislamiento térmico eficaz y duradero de PANELTOR® SATE o COMPACT se debe realizar una instalación correcta tanto de los paneles como del sistema de anclaje, verificando que cada paso de este manual está correctamente realizado.

Es esencial que el soporte sobre el que se aplicará el sistema de paneles esté en perfectas condiciones en cuanto a capacidad de sustentación, limpieza, humedades y regularidad.

Se recomienda llevar a cabo pruebas en todas las superficies para la determinar su capacidad de sustentación antes de la colocación de los sistemas SATE o COMPACT.

Las superficies de hormigón, ladrillo, bloques de hormigón celular, piedra, madera y metal son los soportes recomendados sobre los que se pueden colocar los sistemas de paneles SATE y COMPACT. En cualquier superficie se deberán reparar previamente las faltas de planimetría con productos adecuados.

El soporte debe estar libre materiales sueltos o mal adheridos que puedan provocar cualquier tipo de separación entre el soporte y los paneles.

ELEMENTOS SALIENTES

Tanto en para la colocación de paneles exteriores o interiores, PANELTOR® SATE o COMPACT, los elementos salientes deben estar adecuadamente aislados, para evitar puentes térmicos.

En el caso de la rehabilitación de edificios puede que el panelado interfiera con los elementos existentes, como balcones, marcos de ventanas, cornisas, molduras arquitectónicas, tuberías, soportes, tendido eléctrico, etc. Estos los salientes deben tener un sistema de evacuación de agua de lluvia para evitar filtraciones.

The PANELTOR® SATE outdoor monoblock insulation system and the PANELTOR® COMPACT indoor monoblock insulation system involve the installation of a series of panels and anchors.

In order to achieve efficient and long-lasting thermal insulation of PANELTOR® SATE or COMPACT, both panels and anchorage system must be correctly installed, verifying that each step in this manual is correctly performed.

It is essential that the support on which the panel system will be applied is in perfect condition in terms of support capacity, cleanliness, humidity and regularity.

It is recommended that tests be carried out on all surfaces to determine their load-bearing capacity before installing the SATE or COMPACT systems.

Concrete, brick, aerated concrete block, stone, wood and metal surfaces are the recommended supports on which to place the SATE and COMPACT panel systems. On any surface, any lack of planimetry must be previously repaired with suitable products.

The support must be free of loose or badly adhered materials that could cause any type of separation between the support and the panels.

PROTRUDING ELEMENTS

When installing exterior or interior panels, PANELTOR® SATE or COMPACT, the protruding elements must be adequately insulated to avoid thermal bridges.

In the case of building rehabilitation, paneling may interfere with existing elements, such as balconies, window frames, cornices, architectural mouldings, pipes, supports, electrical wiring, etc. These should have a rainwater drainage system to prevent leakage.

INFO

RM

ACIÓ

N TÉC

NIC

A | TECHN

ICAL INFO

RM

ATION

4

SATE / ETICS | COMPACT

Page 5: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

INFO

RM

ACIÓ

N TÉC

NIC

A | TECHN

ICAL INFO

RM

ATION

5

SATE / ETICS | COMPACT

COLOCACIÓN DE LOS PANELES | PANELS LAYOUT

OK

OK

OK

OK

NO NO

Page 6: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

P

AT E N T A D

O

PATENTED

650

300

C

CD

B

A

2

MONTAJEA. Grapa de inicioB. PANELTOR® SATEC. Grapa de continuaciónD. Sellado

Leyenda1. PANELTOR® SATE2. Grapa de continuación (Inox.304)3. Grapa de inicio-final (Inox 304)4. Varilla roscada M10 Inox.A25. Tuerca M8 Inox.A2 (DIN-934)6. Arandela Growe M10 Inox.A2 (DIN-127-B)7. Tamíz de Nylon8. Resina de poliéster9. Sellado10. Cerramiento de fábrica

INFO

RM

ACIÓ

N TÉC

NIC

A | TECHN

ICAL INFO

RM

ATION

6

SATE / ETICS | COMPACT

PANELTOR® SATE / ETICSPanel: 1270x620 mm | 49x23 in

1

9

3

2

4-5-6 7-8

10

Page 7: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

INFO

RM

ACIÓ

N TÉC

NIC

A | TECHN

ICAL INFO

RM

ATION

7

SATE / ETICS | COMPACT

COLOCACIÓN DE LAS GRAPAS DE INICIO

PLACING OF STARTER STAPLESA

2520x1220 | PANELS

706706

1220

200 5200

5

706

5

1270x620 | PANELS

620

5300 670 300

Grapa continuación Continuation staple

Grapa inicio-final Start-finish staple

Tomar como referencia las ranuras de los panelesTake as a reference the slots of the panels

Page 8: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

INFO

RM

ACIÓ

N TÉC

NIC

A | TECHN

ICAL INFO

RM

ATION

8

SATE / ETICS | COMPACT

FIJACIÓN DE LOS PANELES

PANELINGB

Colocar las ranuras de los paneles sobre las grapasPlace the panel slots on the staples

Dependiendo de la antiguedad del edificio y si el muro soporte está en mal estado, es recomendable añadir cemento cola para mejorar el agarre de los paneles. En el resto de los casos se puede añadir de manera opcional.

Depending on the age of the building and if the supporting wall is in poor condition, it is advisable to add glue cement to improve the grip of the panels. In the rest of the cases it can be added optionally.

Page 9: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

INFO

RM

ACIÓ

N TÉC

NIC

A | TECHN

ICAL INFO

RM

ATION

9

SATE / ETICS | COMPACT

706706

1220

200 5200

5

706

620

5

5300 670 300

2520x1220 | PANELS

1270x620 | PANELS

COLOCACIÓN DE LAS GRAPAS DE CONTINUACIÓN

PLACING OF CONTINUATION STAPLESC

Grapa continuación Continuation staple

Grapa inicio-final Start-finish staple

Tomar como referencia las ranuras de los panelesTake as a reference the slots of the panels

Page 10: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

INFO

RM

ACIÓ

N TÉC

NIC

A | TECHN

ICAL INFO

RM

ATION

10

SATE / ETICS | COMPACT

REPETICIÓN PASOS B Y C. HASTA FINALIZAR L PANELADO

REPEAT STEPS B AND C. TO PANELING FINISHB-C

Grapa continuación Continuation staple

Grapa inicio-final Start-finish staple

706706

1220

200 5200

5

706

620

5

5300 670 300

2520x1220 | PANELS

1270x620 | PANELS

Tomar como referencia las ranuras de los panelesTake as a reference the slots of the panels

Page 11: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

INFO

RM

ACIÓ

N TÉC

NIC

A | TECHN

ICAL INFO

RM

ATION

11

SATE / ETICS | COMPACT

SELLADO DEL PANELADO

PANEL SEALINGD

Page 12: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

P

AT E N T A D

O

PATENTED

MONTAJEA. Grapa de inicioB. PANELTOR® SATEC. Grapa de continuaciónD. Sellado

Leyenda1. PANELTOR® SATE2. Grapa de continuación (Inox.304)3. Grapa de inicio-final (Inox 304)4. Varilla roscada M10 Inox.A25. Tuerca M8 Inox.A2 (DIN-934)6. Arandela Growe M10 Inox.A2 (DIN-127-B)7. Tamíz de Nylon8. Resina de poliéster9. Sellado10. Cerramiento de fábrica11. Cemento cola (opcional)

INFO

RM

ACIÓ

N TÉC

NIC

A | TECHN

ICAL INFO

RM

ATION

12

PROCESO DE INSTALACIÓN | INSTALLATION PROCESS

3

2

4

111

10

56

9

3

27 8

A

D

B

C

PROFUNDIDAD DEL ANCLAJE

85mm

62062

025

15 40

50

4015

5

5m

m5m

m62

0mm

620m

m

1

3

2

SATE / ETICS | COMPACT

Page 13: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

INFO

RM

ACIÓ

N TÉC

NIC

A | TECHN

ICAL INFO

RM

ATION

13

PROCESO DE INSTALACIÓN | INSTALLATION PROCESS

2520x1220 | PANELS

1270x620 | PANELS

Grapa continuación

Grapa inicio-final

SATE / ETICS | COMPACT62

05

620

5300

706706

1220

1220

200 5200

5

670

1270

300

706

2520

Page 14: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

INFO

RM

ACIÓ

N TÉC

NIC

A | TECHN

ICAL INFO

RM

ATION

14

MANUAL DE MANIPULACIÓNHANDLING MANUAL

MANUTENTION MANUELLE

1/5 1/53/5

CARGA Y DESCARGALOADING AND UNLOADINGCHARGEMENT ET DÉCHARGEMENT

ALMACENAMIENTOSTORAGESTOCKAGE

1

21/5 1/53/5

opacoopaque opaque

MANUAL DE MANIPULACIÓNHANDLING MANUALMANUEL DE MANUTENTION

SATE / ETICS | COMPACT

Page 15: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

INFO

RM

ACIÓ

N TÉC

NIC

A | TECHN

ICAL INFO

RM

ATION

15

MANIPULACIÓNHANDLINGMANUTENTION

PANELTOR FIBER, S.L. c/ Las Lomas, 26. 16200 Motilla del Palancar, Cuenca. Spain T. 969 331 782 | E. [email protected] | www.paneltor.com

VERTICAL

3

LIMPIEZACLEANINGNETTOYAGE4REPARACIÓNREPAIRRÉPARATION5

NO CHEMICALS NO HIGH-PRESSUREMICROFIBRE2 - 5 YEARS

DiamondHARD CERAMIC125mm

PANELTOR

100m

m

POREXPANPOREXPAN

PINZASGRAPPLESPINCES

CRISTALGLASSVITRE

VENTOSAVACUUM LIFERVENTOUSE

ES En el caso de que un panel sufra una rotura o un desperfecto en alguna de sus partes, éste puede ser reparado sin ningún tipo de problema. Llamar al teléfono(+34) 969 331 782

FR Dans le cas ou un panneau souffrirait un dommage, celui cí peut-être réparé sans aucun problème. Merci d’appeler au(+34) 969 331 782

EN In case of groove of the panel or damage of any part, the problem can be repaired. For further information, please telephone: (+34) 969 331 782

MANIPULACIÓNHANDLINGMANUTENTION

PANELTOR FIBER, S.L. c/ Las Lomas, 26. 16200 Motilla del Palancar, Cuenca. Spain T. 969 331 782 | E. [email protected] | www.paneltor.com

VERTICAL

3

LIMPIEZACLEANINGNETTOYAGE4REPARACIÓNREPAIRRÉPARATION5

NO CHEMICALS NO HIGH-PRESSUREMICROFIBRE2 - 5 YEARS

DiamondHARD CERAMIC125mm

PANELTOR

100m

m

POREXPANPOREXPAN

PINZASGRAPPLESPINCES

CRISTALGLASSVITRE

VENTOSAVACUUM LIFERVENTOUSE

ES En el caso de que un panel sufra una rotura o un desperfecto en alguna de sus partes, éste puede ser reparado sin ningún tipo de problema. Llamar al teléfono(+34) 969 331 782

FR Dans le cas ou un panneau souffrirait un dommage, celui cí peut-être réparé sans aucun problème. Merci d’appeler au(+34) 969 331 782

EN In case of groove of the panel or damage of any part, the problem can be repaired. For further information, please telephone: (+34) 969 331 782

SATE / ETICS | COMPACT

Page 16: ETICS - paneltor.com®-ETICS... · Special panels: turns, jambs, lintels, etc. Autolimpiante y descontaminante Self-cleaning and antipollution Paneles reparables y reemplazables Reparable

SATE / ETICS | COM

PACT 16

17/0708

PANELTOR FIBER, S.L. c/ Las Lomas, 26. 16200 Motilla del Palancar, Cuenca. Spain

(+34) 96 933 17 82

[email protected]

Horario: de Lunes a Viernes 08.00 – 17.30h

ATENCIÓN AL CLIENTE

Web www.paneltor.com

Linkedin paneltor-facades-uhpc

Instagram paneltor_uhpc

Facebook paneltoruhpc

EDIT

ION

FEB

RU

ARY’

2020

MEDIOS SOCIALES