especificaciones enfriador de agua 7.6 galones elkay mod. efa8l

2
GENERAL Self-contained, electric refrigerated, floor model water cooler. Capacity of 50°F drinking water, based upon 80°F inlet water and 90°F ambient. Non-pressurized tank system is standard. Non-pressurized water tank is located after bubbler valve, so that tank is subject to line pressure only when valve button is pressed. NO LEAD DESIGN THIS WATER COOLER COMPLIES WITH THE LEAD-FREE DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986 AND LEAD CONTAMINATION CONTROL ACT OF 1988. Elkay Water Coolers are manufactured with a waterway sys- tem utilizing copper components and completely lead-free materials. These waterways have no lead because all lead materials, such as leaded brass, have been removed. All joints are brazed using silver solder only. No lead solder is permitted. A strainer with an easily cleanable screen is pro- vided to allow trapping and convenient removal of water born particulate of 140 microns and larger prior to their entry into the water cooler. COOLING SYSTEM Motor Compressor: Hermetically sealed, reciprocating type, 115V, 60 Hertz single phase. Sealed-in lifetime oil supply. Equipped with electric cord and three prong molded rubber plug. Condenser: Fan cooled, copper tube with aluminum fins. (EFA4 has steel tube with steel fins.) Fan motor is permanently lubricated. Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of copper tubing. Fully insulated with EPS foam which meets Underwriters Laboratories Inc. require- ments for self extinguishing material. Refrigerant Control: Refrigerant type HFC-134a is controlled by accurately calibrated capillary tube for positively trouble- free performance. Temperature Control: Enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements. CAPACITIES CHART *Based on 80°F inlet water temperature. •Pre-cooler capacities based on 60% spill through pre-cooler. Glass filler available at extra cost. Require factory preparation to receive glass filler. †† EFA16 and EFA20 meet only the lead-free definition of NSF/ANSI 61. Rated watts shown are based on operational (run) time, in compliance with A.R.I. Standard 1010 conditions. Specific applications will determine the actual watts consumed per hour. Watts consumed will be based on number of people served per hour (usage), ambient temperatures, and inlet water temperature. Foot pedal available. Factory installed only. *GPH of 50°F Drinking Water Full Glass† Ship. Model Base Room Temperature °F Rated Load Filler •Pre- Wt. Number Rate 70°F 80°F 90°F Watts Amps Option Cooler Lbs. EFA4 4.0 4.8 4.4 4.0 230 2.5 Yes No 78 EFA8 7.6 9.2 8.4 7.6 370 4.0 Yes No 81 EFA14 13.5 16.3 14.9 13.5 665 7.2 Yes No 84 †† EFA16 9.6 18.8 17.1 15.5 510 5.5 Yes Yes 87 †† EFA20 12.0 23.6 21.5 19.5 665 7.2 Yes Yes 87 Model EFA4 Elkay 2222 Camden Court Oak Brook, IL 60523 Printed in U.S.A. ©2010 Elkay (Rev. 2/10) 9-2H elkay.com CONSTRUCTION Fountain Top: One piece stainless steel top, polished to a uniform Elkay bright luster finish. Exclusive Cascade basin, tested most splash-resistant, features multi-level deck design with a built-in vandal-resistant strainer. Exclusive Flexi-Guard ® Safety Bubbler**: Innovative design utilizes a pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact, then returns to original position. Strong. Abrasion-resistant. Anti-sweat. Meets UL requirements and all sanitary codes. Removable Panel: Removable front panel offers easy acces- sibility to interior. Color Selection: Gray Beige vinyl furnished as standard unless alternate panel color is selected. Alternate panel colors in vinyl are: Granite, Sandalwood, and Natural Almond. All furnished at no extra cost. Stainless steel available at extra cost. Cabinet: Cabinet design allows for flush to wall mounting or free standing. 5 YEAR LIMITED WARRANTY on the refrigeration system of the unit. Electrical components and water system are war- ranted for 12 months from date of installation. Sample Certificate available on request. Elkay Pressure-Type Water Coolers are designed to operate on 20 psi to 105 psi supply line pressure. If inlet pressure is above 105 psi, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting this product to supply line pressures lower than 20 psi or higher than 105 psi is not covered by the warranty. STANDARDS In keeping with our policy of continuing product improvement, Elkay reserves the right to change product specifications without notice. This specification describes an Elkay product with design, quality and functional benefits to the user. When making a comparison of other producers’ offerings, be certain these features are not overlooked. **Patent #4,481,971 No Lead Floor Model Water Cooler Air Cooled Models EFA4, EFA8, EFA14, EFA16 and EFA20 ® SPECIFICATIONS This cooler is certified by WQA to lead-free compliance including NSF/ANSI 61-ANNEX G, AB 1953. Elkay Electric Air Cooled Water Coolers are listed by Underwriters Laboratories Inc. and comply with both Canadian and U.S. requirements. These units comply with A.R.I. Standard 1010.

Upload: h2o-tek-sa-de-cv

Post on 07-Mar-2016

222 views

Category:

Documents


6 download

DESCRIPTION

ESPECIFICACIONES ENFRIADOR DE AGUA 7.6 GALONES ELKAY MOD. EFA8L

TRANSCRIPT

Page 1: ESPECIFICACIONES ENFRIADOR DE AGUA 7.6 GALONES ELKAY MOD. EFA8L

GENERALSelf-contained, electric refrigerated, floor model water cooler.Capacity of 50°F drinking water, based upon 80°F inlet waterand 90°F ambient.Non-pressurized tank system is standard. Non-pressurizedwater tank is located after bubbler valve, so that tank issubject to line pressure only when valve button is pressed. NO LEAD DESIGNTHIS WATER COOLER COMPLIES WITH THE LEAD-FREE DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986AND LEAD CONTAMINATION CONTROL ACT OF 1988.Elkay Water Coolers are manufactured with a waterway sys-tem utilizing copper components and completely lead-freematerials. These waterways have no lead because all leadmaterials, such as leaded brass, have been removed. Alljoints are brazed using silver solder only. No lead solder ispermitted. A strainer with an easily cleanable screen is pro-vided to allow trapping and convenient removal of water bornparticulate of 140 microns and larger prior to their entry intothe water cooler.

COOLING SYSTEMMotor Compressor: Hermetically sealed, reciprocating type,115V, 60 Hertz single phase. Sealed-in lifetime oil supply.Equipped with electric cord and three prong molded rubber plug.Condenser: Fan cooled, copper tube with aluminum fins.(EFA4 has steel tube with steel fins.) Fan motor is permanentlylubricated.Cooling Unit: Combination tube-tank type. Tube portion iscontinuous coil of copper tubing. Fully insulated with EPSfoam which meets Underwriters Laboratories Inc. require-ments for self extinguishing material.Refrigerant Control: Refrigerant type HFC-134a is controlledby accurately calibrated capillary tube for positively trouble-free performance.Temperature Control: Enclosed adjustable thermostat isfactory preset. Requires no adjustment other than foraltitude requirements.

CAPACITIES CHART

*Based on 80°F inlet water temperature.•Pre-cooler capacities based on 60% spill through pre-cooler.†Glass filler available at extra cost. Require factory preparation to receive glass

filler.††EFA16 and EFA20 meet only the lead-free definition of NSF/ANSI 61.Rated watts shown are based on operational (run) time, in compliance with A.R.I.Standard 1010 conditions. Specific applications will determine the actual wattsconsumed per hour. Watts consumed will be based on number of peopleserved per hour (usage), ambient temperatures, and inlet water temperature. Foot pedal available. Factory installed only.

*GPH of 50°F Drinking WaterFull Glass† Ship.

Model Base Room Temperature °F Rated Load Filler •Pre- Wt.Number Rate 70°F 80°F 90°F Watts Amps Option Cooler Lbs.

EFA4 4.0 4.8 4.4 4.0 230 2.5 Yes No 78

EFA8 7.6 9.2 8.4 7.6 370 4.0 Yes No 81

EFA14 13.5 16.3 14.9 13.5 665 7.2 Yes No 84

†† EFA16 9.6 18.8 17.1 15.5 510 5.5 Yes Yes 87

†† EFA20 12.0 23.6 21.5 19.5 665 7.2 Yes Yes 87

Model EFA4

Elkay 2222 Camden CourtOak Brook, IL 60523

Printed in U.S.A.©2010 Elkay

(Rev. 2/10) 9-2Helkay.com

CONSTRUCTIONFountain Top: One piece stainless steel top, polished to auniform Elkay bright luster finish. Exclusive Cascade basin,tested most splash-resistant, features multi-level deck designwith a built-in vandal-resistant strainer.Exclusive Flexi-Guard® Safety Bubbler**: Innovative designutilizes a pliable polyester elastomer to prevent accidentalmouth injuries. Flexes on impact, then returns to originalposition. Strong. Abrasion-resistant. Anti-sweat. Meets ULrequirements and all sanitary codes.Removable Panel: Removable front panel offers easy acces-sibility to interior.Color Selection: Gray Beige vinyl furnished as standardunless alternate panel color is selected. Alternate panel colors in vinyl are: Granite, Sandalwood, and Natural Almond.All furnished at no extra cost. Stainless steel available at extracost.Cabinet: Cabinet design allows for flush to wall mounting orfree standing.5 YEAR LIMITED WARRANTY on the refrigeration system ofthe unit. Electrical components and water system are war-ranted for 12 months from date of installation. SampleCertificate available on request.Elkay Pressure-Type Water Coolers are designed to operateon 20 psi to 105 psi supply line pressure. If inlet pressure isabove 105 psi, a pressure regulator must be installed in thesupply line. Any damage caused by reason of connecting thisproduct to supply line pressures lower than 20 psi or higherthan 105 psi is not covered by the warranty.STANDARDS

In keeping with our policy of continuing product improvement, Elkay reserves the right to changeproduct specifications without notice.

This specification describes an Elkay product with design, quality and functional benefits to theuser. When making a comparison of other producers’ offerings, be certain these features are notoverlooked.

**Patent #4,481,971

No Lead Floor Model Water CoolerAir Cooled

Models EFA4, EFA8, EFA14, EFA16 and EFA20®

SPECIFICATIONS

This cooler is certified by WQA to lead-free compliance includingNSF/ANSI 61-ANNEX G, AB 1953.

Elkay Electric Air Cooled Water Coolers are listedby Underwriters Laboratories Inc. and comply withboth Canadian and U.S. requirements.

These units comply with A.R.I. Standard 1010.

Page 2: ESPECIFICACIONES ENFRIADOR DE AGUA 7.6 GALONES ELKAY MOD. EFA8L

Elkay 2222 Camden CourtOak Brook, IL 60523

Printed in U.S.A.©2010 Elkay

9-2H (Rev. 2/10)

NOTE: WATERFLOWDIRECTION

SERVICE STOP(NOT FURNISHED)

3/8" O.D. TUBE CONNECTCOLD WATER SUPPLYBY OTHERS

1/4" O.D. TUBEWATER INLETTO COOLER

BUILDING WATERINLET

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH INTUBE TO ATTACH

TUBE IS SECUREDIN POSITION

PUSH IN COLLETTO RELEASE TUBE

PUSHING TUBE IN BEFOREPULLING IT OUT HELPS TO

RELEASE TUBE

A B C

TANK DRAIN

4-5/8"(117mm)

1-1/4" (32mm)O.D. TAILPIECE(TRAP NOT FURNISHED)

14-1/2"(368mm)

18"(457mm)

5"(127mm) 4-1/4"

(108mm)

2-1/2" (64mm)

OPTIONALELECTRICAL OUTLET(BY OTHERS)

NOTE: INSURE PROPER VENTILATION BY MAINTAINING4" (102mm) MINIMUM CLEARANCE FROM CABINETLOUVERS TO WALL ON EACH SIDE OF COOLER.

4 FOOT (1.2mm) LONGPOWER CORD

14-1/2"(368mm)

CL

FLOOR LINE

WATER OUTLET1-1/4" (32mm) I.P.S.

41-1/2"(1054mm)

40"(1016mm)

17"(432mm)

ELECTRICAL OUTLETLOCATION (BY OTHERS)

1-1/4" (32mm) O.D. TAILPIECE3/8" IPS COLD WATERSUPPLY (STUB OUTFROM WALL 1" [25mm])WATER INLET SHUTOFFVALVE BY OTHERS(3/8" O.D. TUBE OUTLET)

PLUMBING ROUGH-IN CAN BE LOCATED ANYWHERE WITHIN THIS AREA.

IMPORTANT!INSTALLER PLEASE NOTE:

This water cooler has been designed and built to provide water to the user which hasnot been altered by materials in the cooler waterways.The grounding of electrical equipment such as telephone, computers, etc., to waterlines is a common procedure. This grounding may be in the building but may alsooccur away from the building. This grounding can cause electrical feedback into awater cooler creating an electrolysis which creates a metallic taste or causes anincrease in the metal content of the water. This condition is avoidable by installing thecooler using the proper materials as shown below.

NOTICEThis water cooler must be connected to the water supply using a dielectric coupling.The cooler is furnished with a non-metallic strainer which meets this requirement.The drain trap which is provided by the installer should also be plastic to completelyisolate the cooler from the building plumbing system.

No Lead Floor Model Water CoolerAir CooledModels EFA4, EFA8, EFA14, EFA16 and EFA20

®

ROUGH-IN DIMENSIONS