www.zfatech.com UNITED STATES Add: 12212 Ashling Dr Stafford, TX, 77477 Tel: +1713 893 4784 CHINA Add:Nanopolis Suzhou: NW02, Room 110, 99 JinjiLake Avenue,Jiangsu Province, P.R. China. Zip: 215123 Tel: +86 512-6999 5236 Fax: +86 512-6999 5237 E-mail: [email protected] Injection Procedures for BERO™ Biosurfactant Basic data requires for injection design 1) Drilling and completion dates, total depth, return top of cement, cement plug depth, casing size and setting depth, wall thickness, distance between casing (tubing) head and bushing, location of casing collar nearby packer sticking point, maximum well deviation and depth, commissioning (injection starting) date and cementing quality 2) Perforated horizon, perforated interval, actual perforated horizon, actual perforated interval, thickness, number of layers and perforation parameters (gun type, density, porosity, penetrability and mud content) 3) Production status: current daily volume of produced liquid, oil production, water cut, pump diameter, working parameter, pump efficiency, oil pay, working fluid level, sand (wax) content, wellhead oil pressure, casing pressure, total salinity, formation temperature and production status of adjacent well of the same formation 4) Properties of crude oil: density, viscosity, freezing point, gum, asphalt and wax content 5) Current status of down-hole string 6) Analysis of problems of well under construction in geological solution 7) Basic geological drawings: comparison diagram of small layers of reservoir, deposition facies diagram of small layers, reservoir fence diagram, reservoir structural diagram, well pattern diagram, etc. Preparation for construction 1) Pretreatment of sand producing formation Before the application of BERO™ biosurfactant, sand control treatment should be conducted on production wells of sand producing formation. 2) Treatment of high water cut formation As we all know, oil recovery = sweep efficiency × oil displacement efficiency. In order to tap the potential of medium and low-penetrability formation, it is necessary to improve sweeping efficiency of injected water and adjust the produced fluid profile of production well. Before the application of BERO™ biosurfactant, high-permeability layers of formation should undergo water shut-off and profile control. Under the good cleaning effect of BERO™ biosurfactant, treated formation certainly will obtain high production with small input.

Upload: matt-wu

Post on 23-Jan-2017

104 views

Category:

Technology


2 download

TRANSCRIPT

www.zfatech.com

UNITED STATES

Add: 12212 Ashling Dr Stafford, TX, 77477 Tel: +1713 893 4784

CHINA Add:Nanopolis Suzhou: NW02, Room 110, 99 JinjiLake Avenue,Jiangsu Province, P.R. China. Zip: 215123 Tel: +86 512-6999 5236 Fax: +86 512-6999 5237 E-mail: [email protected]

Injection Procedures for BERO™ Biosurfactant

Basic data requires for injection design

1) Drilling and completion dates, total depth, return top of cement, cement

plug depth, casing size and setting depth, wall thickness, distance

between casing (tubing) head and bushing, location of casing collar nearby

packer sticking point, maximum well deviation and depth, commissioning

(injection starting) date and cementing quality

2) Perforated horizon, perforated interval, actual perforated horizon, actual

perforated interval, thickness, number of layers and perforation

parameters (gun type, density, porosity, penetrability and mud content)

3) Production status: current daily volume of produced liquid, oil production,

water cut, pump diameter, working parameter, pump efficiency, oil pay,

working fluid level, sand (wax) content, wellhead oil pressure, casing

pressure, total salinity, formation temperature and production status of

adjacent well of the same formation

4) Properties of crude oil: density, viscosity, freezing point, gum, asphalt and

wax content

5) Current status of down-hole string

6) Analysis of problems of well under construction in geological solution

7) Basic geological drawings: comparison diagram of small layers of reservoir,

deposition facies diagram of small layers, reservoir fence diagram,

reservoir structural diagram, well pattern diagram, etc.

Preparation for construction

1) Pretreatment of sand producing formation

Before the application of BERO™ biosurfactant, sand control treatment should

be conducted on production wells of sand producing formation.

2) Treatment of high water cut formation

As we all know, oil recovery = sweep efficiency × oil displacement efficiency. In

order to tap the potential of medium and low-penetrability formation, it is

necessary to improve sweeping efficiency of injected water and adjust the

produced fluid profile of production well. Before the application of BERO™

biosurfactant, high-permeability layers of formation should undergo water

shut-off and profile control. Under the good cleaning effect of BERO™

biosurfactant, treated formation certainly will obtain high production with small

input.

www.zfatech.com

UNITED STATES

Add: 12212 Ashling Dr Stafford, TX, 77477 Tel: +1713 893 4784

CHINA Add:Nanopolis Suzhou: NW02, Room 110, 99 JinjiLake Avenue,Jiangsu Province, P.R. China. Zip: 215123 Tel: +86 512-6999 5236 Fax: +86 512-6999 5237 E-mail: [email protected]

Onsite BERO™ treatment processes

1) Prepare liquid: V=лr2·h·Φ

Where:V—Dosage of BERO™ biosurfactant, expressed in m3

л—3.14

r—Treatment radius of production well, expressed in m

h—Effectively thickness of reservoir, expressed in m

Φ—Effective porosity of reservoir, expressed in %

2) Pull out production string, set tubing to the downhole and flush well with

large displacement.

3) Set construction string (sealing test must be conducted on packer (if any)).

4) Squeeze BERO™ biosurfactant.

5) Squeeze displacement fluid and push BERO™ biosurfactant into the target

zone.

6) Soaking period for 3-5 days.

www.zfatech.com

UNITED STATES

Add: 12212 Ashling Dr Stafford, TX, 77477 Tel: +1713 893 4784

CHINA Add:Nanopolis Suzhou: NW02, Room 110, 99 JinjiLake Avenue,Jiangsu Province, P.R. China. Zip: 215123 Tel: +86 512-6999 5236 Fax: +86 512-6999 5237 E-mail: [email protected]

7) Pull out construction string.

8) Set production string according to planning requirement and resume

production.

Description: Only backflow is needed without moving the pipe string if such

operation as pump inspection is not necessary in production wells. Then the

following steps will be fine: Step 1, Step 4, Step 5, Step 6 and Step 8.