eof office area of work cap center area of work
TRANSCRIPT
WIT
HO
UT
FIR
ST
OB
TA
ININ
G T
HE
EX
PR
ES
S W
RIT
TE
N P
ER
MIS
SIO
N A
ND
CO
NS
EN
T O
F G
AR
RIS
ON
AR
CH
ITE
CT
S.
WR
ITT
EN
DIM
EN
SIO
NS
SH
OP
DE
TA
ILS
MU
ST
BE
SU
BM
ITT
ED
TO
TH
IS O
FF
ICE
FO
R A
PP
RO
VA
L B
EF
OR
E P
RO
CE
ED
ING
WIT
H F
AB
RIC
AT
ION
.C
GA
RR
ISO
N A
RC
HIT
EC
TS
EX
PR
ES
SLY
RE
SE
RV
ES
IT
S C
OM
MO
N L
AW
CO
PY
RIG
HT
AN
D O
TH
ER
PR
OP
ER
TY
RIG
HT
S I
N T
HE
SE
PLA
NS
.O
N T
HE
SE
DR
AW
ING
S S
HA
LL H
AV
E P
RE
CE
DE
NC
E O
VE
R S
CA
LED
DIM
EN
SIO
NS
; C
ON
TR
AC
TO
RS
SH
ALL
VE
RIF
Y,
AN
D B
E R
ES
PO
NS
IBL
E F
OR
AL
L D
IME
NS
ION
S A
ND
CO
ND
ITIO
NS
ON
TH
E J
OB
, A
ND
TH
IS O
FF
ICE
MU
ST
BE
NO
TIF
IED
OF
AN
Y V
AR
IAT
ION
S F
RO
M T
HE
DIM
EN
SIO
NS
AN
D C
ON
DIT
ION
S S
HO
WN
BY
TH
ES
E D
RA
WIN
GS
.T
HE
SE
PL
AN
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D,
CH
AN
GE
D O
R C
OP
IED
IN
AN
Y F
OR
M O
R M
AN
NE
R W
HA
TS
OE
VE
R,
NO
R A
RE
TH
EY
TO
BE
AS
SIG
NE
D T
O A
NY
TH
IRD
PA
RT
Y,
MULHERN CONSULTING ENGINEERSAND ASSOCIATES, INC.321 SOUTH YORK ROAD HATBORO, PA 19040P: 215-293-9900 F: 215-293-9214
A Professional Corporation of Architects and Planners
713 CREEK ROAD, BELLMAWR, NJ 08053 (856) 396-6200 F(856) 396-6205
INTERNATIONAL BUILDING CODE/2018/ NJ EDITIONINTERNATIONAL MECHANICAL CODE/2018INTERNATIONAL FUEL GAS CODE/2018NATIONAL STANDARD PLUMBING CODE/2018ASHRAE 90.1-2016 ENERGY STANDARDNATIONAL ELECTRICAL CODE(NFPA 70)/2017INTERNATIONAL FIRE CODE/2018ELEVATOR SUBCODE (NJAC 5:23-12):
AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)BARRIER FREE SUBCODE:ICC/ANSI A117.1-2009N.J. REHAB CODE NJAC 5:23-6, NJUCC. SUBCHAPTER 6, 2018NJ UCC BULLETIN 00-3: PUBLIC SCHOOLS-FACILITY PLANNING STANDARDS &UCC ENHANCEMENTS
ELEV.
RWC
RWC
RWC
RWCRWC
RWC
RWCRWC
ELECT.RM
STORAGE
STORAGE
F.E.
CLOSET
OFFICE
CLOSET
LOUNGE OFFICE
STOR. STOR.
OFFICESUITE
OFFICESUITE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE OFFICE
EOF SUITE
OFFICE210E
95 SF
OFFICEOFFICE
OFFICE
OFFICE
M E Z Z A N I N E A R E A B E L O W
CAP CENTER
UPPERLANDING
INTERMEDIATELANDING
TESTING
STAIR
STAIR
UNIVERSITYCENTER
OFFICEOFFICE
OFFICE
UNIVERSITYCENTER
OFFICEOFFICE
CONF.
OFFICE202B
87 SF
OFFICE202A
87 SF
OFFICE202C
169 SFOFFICE202D
103 SF
202
290 SFSTUDENT LIFE
203
358 SF
OFFICE203C
122 SFOFFICE203B
174 SF
STOR.203A
68 SF
CONF.203D
312 SF
CORRIDOR '200'
CAP CENTER
STUDENT AFFAIRS
209EOFFICE72 SF
OIRASUITE
OFFICE OFFICE OFFICE
DN12R
DN12R
DN11R
DN7R
DN7R
DN12R
DN12R
DN11R
207207A
207B
207C
207D 207E
208C207F
208
208A
208B
208D
209B
209A
209C 209D
210
210B210A
210D
210C212
211C
213B
213A
206
206B 206A
206C
ST-A2
ST-B2
200
200A200B
200C
200D
200E
201
201A201B
201C
201D
C-200
212D
209
212A 212B 212C
1362 SF1886 SF
1000 SF
630 SF
557 SF
824 SF
963 SF
1000 SF
1000 SF 100 SF 100 SF 100 SF
204H
204G
204F
204D
204A
204B
204C
204
204E
OFFICE
ASST DIR.
DIR.OFFICE
STORAGE
OFFICE
OFFICE
CONFERENCE
EOF OFFICE SUITE
COPY/WORK RM.
106 S.F.
130 S.F.
168 S.F.
101 S.F.
160 S.F.
184 S.F.
112 S.F.
108 S.F.
809 S.F.
204H
204G
204F
204E204D
204C
204B
204A
212A 212B 212C
CAP CENTERAREAOF WORK
COLLEGE CENTER SECOND FLOOR PLAN
EOF OFFICEAREA OF WORK
1A3-CC
TYP.
1A3-CC
TYP.
1A3-CC
TYP.
1A3-CC
TYP.1
A3-CC
TYP.
1A3-CC
TYP.
1A3-CC
1A3-CC
TYP.
TYP.
1A3-CC
TYP.
1
3
3
1
2
EXISTING CEILING TO REMAIN: EXISTING SUSPENDED ACOUSTICAL CEILING SYSTEM TO REMAIN. .SEE ELEC. DWGS. FOR REVISED SWITCHING, ETC. RELOCATE EXISTING AND/OR ADD HVAC AIRDEVICES AS SHOWN. SEE MECH. DWGS. FOR ANY HVAC RELATED SCOPE OF WORK. FIRE ALARMDEVICE LOCATIONS AND QUANTITIES SHALL BE MODIFIED AS REQUIRED BY NEW ROOM LAYOUT (SEEELEC. DWGS.) EXISTING FIRE SPRINKLER LAYOUT AND QUANTITIES SHALL BE MODIFIED AS REQUIREDBY NEW ROOM LAYOUT NEW SPRINKLER HEADS & HEAT DECTORS SHALL BE PROVIDED PER THISPLAN. REPLACE CEILING TILES TO MATCH ADJACENT EXISTING AS REQUIRED TO COVER SIGNS OFRENOVATION.
1
REFER TO MECHANICAL & ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR MORE INFORMATION. THEMAJORITY OF CEILING MOUNTED LIGHT FIXTURES AND AIR DEVICES ARE SHOWN HERE FOR BASICINTENT. THE CONTRACTOR IS RESPONSIBLE FOR PREPARING COMPREHENSIVE COORDINATION DRAWINGS,VERIFYING AVAILABLE AREA AND ABOVE CEILING CLEARANCE. DRAWINGS SHALL INCORPORATE THEWORK OF ALL APPLICABLE TRADES AND ALL CEILING MOUNTED EQUIPMENT, INCLUDING ALL EXISTINGPOTENTIAL CONFLICTS (EXISTING PIPE, DUCT, ETC.).
CEILING/RENOVATION NOTES:
1 EXISTING DOOR TO REMAIN
2 EXISTING DOOR & FRAMESYSTEM TO BE REMOVED
3 INFILL AREA TO MATCHADJACENT SURFACE
GENERAL NOTES:
KEY NOTES: #
KEY NOTE#
1 ALL DIMENSIONS OR SCALES SHOWN AS PLUS OR MINUS (±)ARE FOR INFORMATIONAL PURPOSES AND SHALL NOT BETAKEN AS EXACT. CONTRACTOR SHALL FIELD VERIFY ALLDIMENSIONS AND OPENINGS.
2 THE OWNER AND ARCHITECT ASSUME NO RESPONSIBILITY FORTHE EXISTING ACTUAL CONDITIONS THAT THE CONTRACTORMAY ENCOUNTER DURING THE COURSE OF THE WORK.
3 EXISTING FLOOR/FLOOR FINISH, WALLS, CEILING & LIGHTING TOREMAIN. PROTECT DURING RENOVATIONS / CONSTRUCTION.
4 PATCH HOLES IN EXISTING WALLS WITH MATERIALS TO MATCHADJACENT SURFACES.
5 PAINT ALL EXISTING AND NEW WALLS IN THE OFFICE SUITE.
6 ALL ELECTRICAL WORK BY LICENSED ELECTRICAL CONTRACTORAND TO COMPLY WITH THE LATEST NEC ELECTRICAL CODE.
7 ELECTRICAL CONTRACTOR TO DISCONNECT, CAP AND REMOVEOR RELOCATE LIGHT FIXTURES, TV CAMERAS, SWITCHES, WALLOUTLETS, POWER POLES, EMERGENCY POWER SHUT OFFS,ELECTRICAL PANELS, ETC. AND ALL RELATED APPURTENANCESIN A CODE APPROVED MANNER. RELOCATE & RECONNECTELECTRICAL ITEMS PER OWNER'S DIRECTION. THE RELOCATIONTO INCLUDE ANY RE-WIRING, POWER AND/OR SWITCHES.
8 EXISTING CEILING SYSTEM TO REMAIN. WHERE WORK IS TO BEDONE ABOVE EXISTING LAY-IN CEILING SYSTEM, IT IS THESOLE RESPONSIBILITY OF THAT DESIGNATED CONTRACTOR TOREMOVE AND/OR CUT NECESSARY CEILING TILES AND GRIDREQUIRED FOR INSTALLATION, THEN PATCH GRID ANDREINSTALL CEILING TILES AFTER INSTALLATION. RESTOREROOM TO PREVIOUS CONDITION PRIOR TO RENOVATION.
9 DURING CONSTRUCTION, CLEAN AND PROTECT WORK INPROGRESS. PROMPTLY REMOVE ANY DEBRIS FROM THE SITE.NO TRASH ACCUMULATION IS PERMITTED. TRANSPORT ANDLEGALLY DISPOSE OF MATERIAL OFF SITE.
10 COORDINATE WITH OWNER ALL DEMOLITION WORK PRIOR TOCONSTRUCTION TO DETERMINE WHICH ITEMS TO SALVAGEAND TO GIVE TO OWNER.
LEGEND
EXISTING WALLS/PARTITIONS TO REMAIN
NEW WALLS/PARTITIONS
ROOM NAME# ROOM NUMBER
DETAIL
NEW DOOR TYPE:
#
SECTION#
#
EXISTING WALLS/PARTITIONS TO BE REMOVED
(REFER TO SHEET A3-CC)
OFFICE
ASST DIR.
DIR.OFFICE
STORAGE
OFFICE
OFFICE
CONFERENCE
EOF OFFICE SUITE
COPY/WORK RM.
STUDENT LIFE
OFFICE203B
174 SF
STOR.203A
68 SF
CORRIDOR '200'
206A
C-200
1
1A3-CC
TYP.
1A3-CC
TYP.
1A3-CC
TYP.
1A3-CC
TYP.1
A3-CC
TYP.
1A3-CC
TYP.
204H
204G
204F
204D
204A
204B
204C
204
204E
106 S.F.
130 S.F.
168 S.F.
101 S.F.
160 S.F.
184 S.F.
112 S.F.
108 S.F.
809 S.F.
204H
204G
204F
204E204D
204C
204B
204A
5'-
4"
3'-
4" 4"
7'-
2"
3'-
4" 4
"4
"3'-
4"1
'-6
"
8'-
55
8"
12'-0"
478"
12'-0"
478"
18'-1114"
478"
12'-0"
14
'-0
"
47
8"
10
'-1
0"
47
8"
15
'-4
1 2"
47
8"
9'-
0"
47
8"
9'-
6"
5'-
10
"3
'-4
"
4"
4"
3'-
4"
5'-
4"
4"3
'-4
"2
'-1
0"
47
8"
2 '-10" 3'-4"2'-10"3'-4"
9'-
0"
STUDENT LOUNGE204
973 SFSTUDENT LOUNGE
205
973 SF
STUDENT LIFE
OFFICE203B
174 SF
STOR.203A
68 SF
CORRIDOR '200'
206A
C-200
ELEV.
RWC
RWC
RWC
RWCRWC
RWC
RWCRWCRWC
ELECT.RM
STORAGE
STORAGE
F.E.
CLOSET
OFFICE
CLOSET
LOUNGE OFFICE
STOR. STOR.
OFFICESUITE
OFFICESUITE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE OFFICE
EOF SUITE
OFFICE210E
95 SF
OFFICEOFFICE
OFFICE
OFFICE
M E Z Z A N I N E A R E A B E L O W
CAP CENTERUPPER
LANDING
INTERMEDIATELANDING
TESTING
STAIR
STAIR
UNIVERSITYCENTER
OFFICEOFFICE
OFFICE
UNIVERSITYCENTER
OFFICEOFFICE
CONF.
OFFICE202B
87 SF
OFFICE202A
87 SF
OFFICE202C
169 SFOFFICE202D
103 SF
202
290 SFSTUDENT LIFE
203
358 SF
OFFICE203C
122 SFOFFICE203B
174 SF
STOR.203A
68 SF
CONF.203D
312 SF
STUDENT LOUNGE204
973 SFSTUDENT LOUNGE
205
973 SF
CORRIDOR '200'
CAP CENTER
STUDENT AFFAIRS
209EOFFICE72 SF
OIRASUITE
DN12R
DN12R
DN11R
DN7R
DN7R
DN12R
DN12R
DN11R
207207A
207B
207C
207D 207E
208C207F
208
208A
208B
208D
209B
209A
209C 209D
210
210B210A
210D
210C
212
211C
213B
213A
206
206B 206A
206C
ST-A2
ST-B2
200
200A200B
200C
200D
200E
201
201A201B
201C
201D
C-200
212
209
1362 SF1886 SF
1000 SF
2000 SF
557 SF
824 SF
963 SF
2000 SF
1000 SF
SCALE: N.T.S.-
-
SCALE: 1/4"=1'-0"A1-CC
2
SCALE: 1/4"=1'-0"A1-CC
1
EOF OFFICEAREAOF WORK
SECOND FLOOR COLLEGE CENTER KEY PLAN
SECOND FLOOR COLLEGE CENTER PROPOSED PLAN SECOND FLOOR COLLEGE CENTER EXISTING PLAN
SEE GENERAL NOTES
EOF OFFICE RM.204 EOF OFFICE RM.204
NOTED
Project No.
Date:
Scale:
REVISIONSa.b.c.
A P
rofe
ssio
na
l C
orp
ora
tio
n o
f A
rch
ite
cts
an
d P
lan
ne
rs
71
3 C
RE
EK
RO
AD
, B
EL
LM
AW
R,
NE
W J
ER
SE
Y 0
80
31
(8
56
) 3
96
-62
00
DR
AW
ING
S S
HA
LL
HA
VE
PR
EC
ED
EN
CE
OV
ER
SC
AL
ED
DIM
EN
SIO
NS
; C
ON
TR
AC
TO
RS
SH
AL
L V
ER
IFY
, A
ND
BE
RE
SP
ON
SIB
LE
FO
R A
LL
DIM
EN
SIO
NS
AN
D C
ON
DIT
ION
S O
N T
HE
JO
B,
AN
D T
HIS
OF
FIC
E M
US
T B
E N
OT
IFIE
D O
F A
NY
VA
RIA
TIO
NS
FR
OM
TH
E D
IME
NS
ION
S A
ND
CO
ND
ITIO
NS
SH
OW
N B
Y T
HE
SE
DR
AW
ING
Sc
GA
RR
ISO
N A
RC
HIT
EC
TS
EX
PR
ES
SL
Y R
ES
ER
VE
S I
TS
CO
MM
ON
LA
W C
OP
YR
IGH
T A
ND
OT
HE
R P
RO
PE
RT
Y R
IGH
TS
IN
TH
ES
E P
LA
NS
. T
HE
SE
PL
AN
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D,
CH
AN
GE
D,
OR
CO
PIE
D I
N A
NY
FO
RM
OR
MA
NN
ER
WH
AT
SO
EV
ER
, N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y T
HIR
D P
AR
TY
, W
ITH
OU
TF
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
GA
RR
ISO
N A
RC
HIT
EC
TS
. W
RIT
TE
N D
IME
NS
ION
S O
N T
HE
SE
. S
HO
P D
ET
AIL
S M
US
T B
E S
UB
MIT
TE
D T
O T
HIS
OF
FIC
E F
OR
AP
PR
OV
AL
BE
FO
RE
PR
OC
EE
DIN
G W
ITH
FA
BR
ICA
TIO
N.
21-88
ELEV.
STORAGE
CAP CENTER212
211C
950 SF
2
EXISTING CEILING TO REMAIN: EXISTING SUSPENDED ACOUSTICAL CEILING SYSTEM TO REMAIN. .SEE ELEC. DWGS. FOR REVISED SWITCHING, ETC. RELOCATE EXISTING AND/OR ADD HVAC AIRDEVICES AS SHOWN. SEE MECH. DWGS. FOR ANY HVAC RELATED SCOPE OF WORK. FIRE ALARMDEVICE LOCATIONS AND QUANTITIES SHALL BE MODIFIED AS REQUIRED BY NEW ROOM LAYOUT (SEEELEC. DWGS.) EXISTING FIRE SPRINKLER LAYOUT AND QUANTITIES SHALL BE MODIFIED AS REQUIREDBY NEW ROOM LAYOUT NEW SPRINKLER HEADS & HEAT DECTORS SHALL BE PROVIDED PER THISPLAN. REPLACE CEILING TILES TO MATCH ADJACENT EXISTING AS REQUIRED TO COVER SIGNS OFRENOVATION.
1
REFER TO MECHANICAL & ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR MORE INFORMATION. THEMAJORITY OF CEILING MOUNTED LIGHT FIXTURES AND AIR DEVICES ARE SHOWN HERE FOR BASICINTENT. THE CONTRACTOR IS RESPONSIBLE FOR PREPARING COMPREHENSIVE COORDINATION DRAWINGS,VERIFYING AVAILABLE AREA AND ABOVE CEILING CLEARANCE. DRAWINGS SHALL INCORPORATE THEWORK OF ALL APPLICABLE TRADES AND ALL CEILING MOUNTED EQUIPMENT, INCLUDING ALL EXISTINGPOTENTIAL CONFLICTS (EXISTING PIPE, DUCT, ETC.).
CEILING/RENOVATION NOTES:
1 EXISTING DOOR TO REMAIN
2 EXISTING DOOR & FRAMESYSTEM TO BE REMOVED
3 INFILL AREA TO MATCHADJACENT SURFACE
GENERAL NOTES:
KEY NOTES: #
KEY NOTE#
1 ALL DIMENSIONS OR SCALES SHOWN AS PLUS OR MINUS (±)ARE FOR INFORMATIONAL PURPOSES AND SHALL NOT BETAKEN AS EXACT. CONTRACTOR SHALL FIELD VERIFY ALLDIMENSIONS AND OPENINGS.
2 THE OWNER AND ARCHITECT ASSUME NO RESPONSIBILITY FORTHE EXISTING ACTUAL CONDITIONS THAT THE CONTRACTORMAY ENCOUNTER DURING THE COURSE OF THE WORK.
3 EXISTING FLOOR/FLOOR FINISH, WALLS, CEILING & LIGHTING TOREMAIN. PROTECT DURING RENOVATIONS / CONSTRUCTION.
4 PATCH HOLES IN EXISTING WALLS WITH MATERIALS TO MATCHADJACENT SURFACES.
5 PAINT ALL EXISTING AND NEW WALLS IN THE OFFICE SUITE.
6 ALL ELECTRICAL WORK BY LICENSED ELECTRICAL CONTRACTORAND TO COMPLY WITH THE LATEST NEC ELECTRICAL CODE.
7 ELECTRICAL CONTRACTOR TO DISCONNECT, CAP AND REMOVEOR RELOCATE LIGHT FIXTURES, TV CAMERAS, SWITCHES, WALLOUTLETS, POWER POLES, EMERGENCY POWER SHUT OFFS,ELECTRICAL PANELS, ETC. AND ALL RELATED APPURTENANCESIN A CODE APPROVED MANNER. RELOCATE & RECONNECTELECTRICAL ITEMS PER OWNER'S DIRECTION. THE RELOCATIONTO INCLUDE ANY RE-WIRING, POWER AND/OR SWITCHES.
8 EXISTING CEILING SYSTEM TO REMAIN. WHERE WORK IS TO BEDONE ABOVE EXISTING LAY-IN CEILING SYSTEM, IT IS THESOLE RESPONSIBILITY OF THAT DESIGNATED CONTRACTOR TOREMOVE AND/OR CUT NECESSARY CEILING TILES AND GRIDREQUIRED FOR INSTALLATION, THEN PATCH GRID ANDREINSTALL CEILING TILES AFTER INSTALLATION. RESTOREROOM TO PREVIOUS CONDITION PRIOR TO RENOVATION.
9 DURING CONSTRUCTION, CLEAN AND PROTECT WORK INPROGRESS. PROMPTLY REMOVE ANY DEBRIS FROM THE SITE.NO TRASH ACCUMULATION IS PERMITTED. TRANSPORT ANDLEGALLY DISPOSE OF MATERIAL OFF SITE.
10 COORDINATE WITH OWNER ALL DEMOLITION WORK PRIOR TOCONSTRUCTION TO DETERMINE WHICH ITEMS TO SALVAGEAND TO GIVE TO OWNER.
LEGEND
EXISTING WALLS/PARTITIONS TO REMAIN
NEW WALLS/PARTITIONS
ROOM NAME# ROOM NUMBER
DETAIL
NEW DOOR TYPE:
#
SECTION#
#
EXISTING WALLS/PARTITIONS TO BE REMOVED
(REFER TO SHEET A3-CC)
ELEV.
STORAGE
CAP CENTER
OFFICE OFFICE OFFICE
212
211C
212A 212B 212C
630 SF
100 SF 100 SF 100 SF
3
3
1
2
3'-4"
8'-
4"
8 '-10"
478"
8'-10"
478"
8'-10"
11
'-6
"
47
8"
212A 212B 212C
1A3-CC
1A3-CC
TYP.
TYP.
1A3-CC
TYP.
ELEV.
RWC
RWC
RWC
RWCRWC
RWC
RWCRWCRWC
ELECT.RM
STORAGE
STORAGE
F.E.
CLOSET
OFFICE
CLOSET
LOUNGE OFFICE
STOR. STOR.
OFFICESUITE
OFFICESUITE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE OFFICE
EOF SUITE
OFFICE210E
95 SF
OFFICEOFFICE
OFFICE
OFFICE
M E Z Z A N I N E A R E A B E L O W
CAP CENTERUPPER
LANDING
INTERMEDIATELANDING
TESTING
STAIR
STAIR
UNIVERSITYCENTER
OFFICEOFFICE
OFFICE
UNIVERSITYCENTER
OFFICEOFFICE
CONF.
OFFICE202B
87 SF
OFFICE202A
87 SF
OFFICE202C
169 SFOFFICE202D
103 SF
202
290 SFSTUDENT LIFE
203
358 SF
OFFICE203C
122 SFOFFICE203B
174 SF
STOR.203A
68 SF
CONF.203D
312 SF
STUDENT LOUNGE204
973 SFSTUDENT LOUNGE
205
973 SF
CORRIDOR '200'
CAP CENTER
STUDENT AFFAIRS
209EOFFICE72 SF
OIRASUITE
DN12R
DN12R
DN11R
DN7R
DN7R
DN12R
DN12R
DN11R
207207A
207B
207C
207D 207E
208C207F
208
208A
208B
208D
209B
209A
209C 209D
210
210B210A
210D
210C
212
211C
213B
213A
206
206B 206A
206C
ST-A2
ST-B2
200
200A200B
200C
200D
200E
201
201A201B
201C
201D
C-200
212
209
1362 SF1886 SF
1000 SF
2000 SF
557 SF
824 SF
963 SF
2000 SF
1000 SF
CAP CENTERAREAOF WORK
SECOND FLOOR COLLEGE CENTER KEY PLAN
SECOND FLOOR COLLEGE CENTER PROPOSED PLANCAP CENTER RM.212
SECOND FLOOR COLLEGE CENTER EXISTING PLANCAP CENTER RM.212
SCALE: N.T.S.-
-
SCALE: 1/4"=1'-0"A2-CC
1
SCALE: 1/4"=1'-0"A2-CC
1
NOTED
8-31-2020
11-13-2020
Project No.
Date:
Scale:
REVISIONSa.b.c.
A P
rofe
ssio
na
l C
orp
ora
tio
n o
f A
rch
ite
cts
an
d P
lan
ne
rs
71
3 C
RE
EK
RO
AD
, B
EL
LM
AW
R,
NE
W J
ER
SE
Y 0
80
31
(8
56
) 3
96
-62
00
DR
AW
ING
S S
HA
LL
HA
VE
PR
EC
ED
EN
CE
OV
ER
SC
AL
ED
DIM
EN
SIO
NS
; C
ON
TR
AC
TO
RS
SH
AL
L V
ER
IFY
, A
ND
BE
RE
SP
ON
SIB
LE
FO
R A
LL
DIM
EN
SIO
NS
AN
D C
ON
DIT
ION
S O
N T
HE
JO
B,
AN
D T
HIS
OF
FIC
E M
US
T B
E N
OT
IFIE
D O
F A
NY
VA
RIA
TIO
NS
FR
OM
TH
E D
IME
NS
ION
S A
ND
CO
ND
ITIO
NS
SH
OW
N B
Y T
HE
SE
DR
AW
ING
Sc
GA
RR
ISO
N A
RC
HIT
EC
TS
EX
PR
ES
SL
Y R
ES
ER
VE
S I
TS
CO
MM
ON
LA
W C
OP
YR
IGH
T A
ND
OT
HE
R P
RO
PE
RT
Y R
IGH
TS
IN
TH
ES
E P
LA
NS
. T
HE
SE
PL
AN
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D,
CH
AN
GE
D,
OR
CO
PIE
D I
N A
NY
FO
RM
OR
MA
NN
ER
WH
AT
SO
EV
ER
, N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y T
HIR
D P
AR
TY
, W
ITH
OU
TF
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
GA
RR
ISO
N A
RC
HIT
EC
TS
. W
RIT
TE
N D
IME
NS
ION
S O
N T
HE
SE
. S
HO
P D
ET
AIL
S M
US
T B
E S
UB
MIT
TE
D T
O T
HIS
OF
FIC
E F
OR
AP
PR
OV
AL
BE
FO
RE
PR
OC
EE
DIN
G W
ITH
FA
BR
ICA
TIO
N.
21-88
SCALE: 3"=1'-0" SCALE: 3"=1'-0"
2"
4 7
/8"
6"
4 7/8"
2"
6"
TYPICAL INTERIOR PARTITIONWALL
BOX STUD HEADER3-5/8": 3'-0" WIDE OR LESS6": 3'-0" TO 6'-0" WIDE10": 6'-0" TO 8'-0" WIDE
CAULK PERIMETER, TYP.
16 GAUGE, WELDED CORNERCONSTRUCTED, PAINTED HOLLOWMETAL FRAME
1 3/4" INTERIOR DOOR(SEE SCHEDULE)
1 3/4" INTERIOR DOOR(SEE SCHEDULE)
16 GAUGE, WELDEDCORNER CONSTRUCTED,PAINTED HOLLOW METALFRAME
TYPICAL INTERIORPARTITION WALL
DOUBLE METAL STUDS(TYPICAL AT OPENINGS)
CAULK PERIMETER, TYP.
SOLID COREWOOD DOOR
(42
" M
AX
.)*
14" TEMPEREDGLAZING
PRE-FINISHEDMETAL TRIM
*CODE REQUIRES43" MAX. A.F.F.TO D.L.O.
16 GAUGEHOLLOW METALWELDED FRAME
7'-
0"
1 ' -9"5"10"
12
"2
'-6
"3
'-6
"
3 ' -0"
7'-
0"
7'-
2"
3 ' -0"
3'-4"2"
2"
2"
(DO
OR
OP
EN
ING
)
(DOOR OPENING)
SCALE 3/8"=1'-0"SCALE 3/8"=1'-0"DOOR TYPES:FRAME TYPES:
HARDWARE SCHEDULE NOTE:MATCH EXISTING DOORS AND ALLEGION - SCHLAGE HARDWARE
HARDWARE SCHEDULE NOTE:MATCH EXISTING DOORS AND ALLEGION - SCHLAGE HARDWARE
PROVIDE CONSTRUCTION CORES.THE OWNER WILL PROVIDE THE PROPRIETARY CORES AND KEYS
NO. LOCATIONDOOR FRAME FIRE
RATING(MIN.)
HARDWARE SETIDENTIFICATION SIGNAGE
REMARKSWIDTH HEIGHT TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILL TYPE TEXT
204A OFFICE (204A) 3'-0" 7'-0" D2 SC. WD.CHERRYMATCHEXIST'G
F2 HM PTD. - 1 2 - A NAME & NUMBER TBD
204B OFFICE (204B) 3'-0" 7'-0" D2 SC. WD.CHERRYMATCHEXIST'G
F2 HM PTD. - 1 2 - A NAME & NUMBER TBD
204C OFFICE (204C) 3'-0" 7'-0" D2 SC. WD.CHERRYMATCHEXIST'G
F2 HM PTD. - 1 2 - A NAME & NUMBER TBD
204D OFFICE (204D) 3'-0" 7'-0" D2 SC. WD.CHERRYMATCHEXIST'G
F2 HM PTD. - 1 2 - A NAME & NUMBER TBD
204E OFFICE (204E) 3'-0" 7'-0" D2 SC. WD.CHERRYMATCHEXIST'G
F2 HM PTD. - 1 2 - A NAME & NUMBER TBD
204F OFFICE (204F) 3'-0" 7'-0" D2 SC. WD.CHERRYMATCHEXIST'G
F2 HM PTD. - 1 2 - A NAME & NUMBER TBD
204G OFFICE (204G) 3'-0" 7'-0" D2 SC. WD.CHERRYMATCHEXIST'G
F2 HM PTD. - 1 2 - A NAME & NUMBER TBD
204H OFFICE (204H) 3'-0" 7'-0" D2 SC. WD.CHERRYMATCHEXIST'G
F2 HM PTD. - 1 2 - A NAME & NUMBER TBD
NO. LOCATIONDOOR FRAME FIRE
RATING(MIN.)
HARDWARE SETIDENTIFICATION SIGNAGE
REMARKSWIDTH HEIGHT TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILL TYPE TEXT
212A OFFICE (212A) 3'-0" 7'-0" D2 SC. WD.CHERRYMATCHEXIST'G
F2 HM PTD. - 1 2 - A NAME & NUMBER TBD
212B OFFICE (212B) 3'-0" 7'-0" D2 SC. WD.CHERRYMATCHEXIST'G
F2 HM PTD. - 1 2 - A NAME & NUMBER TBD
212C OFFICE (212C) 3'-0" 7'-0" D2 SC. WD.CHERRYMATCHEXIST'G
F2 HM PTD. - 1 2 - A NAME & NUMBER TBD
3 5/8" METAL STUD @16" O.C. MAX.
58" 3 5
8" 58"
478"
-5/8" GYPSUM BOARD (TYP.)
A3-CC1
SEE DETAIL 2 FORTOP CONNECTION
SEE DETAIL 3 FORBOTTOM CONNECTION
NOTE: NO FIRE RATING REQUIRED.
A3-CC3
-5/8" GYPSUM BOARD (TYP.)
A3-CC2
-5/8" GYPSUM WALL BOARD
1"
4 7/8" METAL STUD WALL
DETAILSTUD WALL AT FLOOR
DETAILDETAILSTUD WALL AT CEILING TILE
NO SCALE NO SCALE NO SCALE
3 5/8" HIGH DENSITYACOUSTICAL INSULATION
METAL STUD @ 16"O.C. MAX.
STEEL RUNNER
4" VINYL WALL BASE
ACOUSTICAL CAULK CONCRETE SLAB
HIGH DENSITYACOUSTICAL INSULATION
6" UNFACED ACOUSTICALCEILING BATTS IN EACHOFFICE AREA
ACOUSTICAL CEILING SYS.EXISTING
"J" BEAD TRIM(BOTH SIDES)
DEEP FORM STEEL RUNNER(FASTEN TO CEILING SYS.)
METAL STUD @ 16" O.C. MAX
HIGH DENSITYACOUSTICAL INSULATION
FIN. FLOOREXIST. FL. TO REMAIN
NOTED
8-31-2020
11-13-2020
Project No.
Date:
Scale:
REVISIONSa.b.c.
A P
rofe
ssio
na
l C
orp
ora
tio
n o
f A
rch
ite
cts
an
d P
lan
ne
rs
71
3 C
RE
EK
RO
AD
, B
EL
LM
AW
R,
NE
W J
ER
SE
Y 0
80
31
(8
56
) 3
96
-62
00
DR
AW
ING
S S
HA
LL
HA
VE
PR
EC
ED
EN
CE
OV
ER
SC
AL
ED
DIM
EN
SIO
NS
; C
ON
TR
AC
TO
RS
SH
AL
L V
ER
IFY
, A
ND
BE
RE
SP
ON
SIB
LE
FO
R A
LL
DIM
EN
SIO
NS
AN
D C
ON
DIT
ION
S O
N T
HE
JO
B,
AN
D T
HIS
OF
FIC
E M
US
T B
E N
OT
IFIE
D O
F A
NY
VA
RIA
TIO
NS
FR
OM
TH
E D
IME
NS
ION
S A
ND
CO
ND
ITIO
NS
SH
OW
N B
Y T
HE
SE
DR
AW
ING
Sc
GA
RR
ISO
N A
RC
HIT
EC
TS
EX
PR
ES
SL
Y R
ES
ER
VE
S I
TS
CO
MM
ON
LA
W C
OP
YR
IGH
T A
ND
OT
HE
R P
RO
PE
RT
Y R
IGH
TS
IN
TH
ES
E P
LA
NS
. T
HE
SE
PL
AN
S A
RE
NO
T T
O B
E R
EP
RO
DU
CE
D,
CH
AN
GE
D,
OR
CO
PIE
D I
N A
NY
FO
RM
OR
MA
NN
ER
WH
AT
SO
EV
ER
, N
OR
AR
E T
HE
Y T
O B
E A
SS
IGN
ED
TO
AN
Y T
HIR
D P
AR
TY
, W
ITH
OU
TF
IRS
T O
BT
AIN
ING
TH
E E
XP
RE
SS
WR
ITT
EN
PE
RM
ISS
ION
AN
D C
ON
SE
NT
OF
GA
RR
ISO
N A
RC
HIT
EC
TS
. W
RIT
TE
N D
IME
NS
ION
S O
N T
HE
SE
. S
HO
P D
ET
AIL
S M
US
T B
E S
UB
MIT
TE
D T
O T
HIS
OF
FIC
E F
OR
AP
PR
OV
AL
BE
FO
RE
PR
OC
EE
DIN
G W
ITH
FA
BR
ICA
TIO
N.
21-88
204HOFFICE
204GASST DIR.
204FDIR.OFFICE
204DSTORAGE
204AOFFICE
204BOFFICE
204CCONFERENCE
204EOF OFFICE SUITE
204ECOPY/WORK RM.
1E1.1
EOF SUITE LIGHTING PLAN
EX
EX
EX
EX
REL
A
EX EX
EXEX
EX
A
A
A
S DL
S DL
S DL
SDL SDL
SD
LS
DL
SD
L
LROC
LROC
LROC
OCLR
OCLR
REL
REL
REL
REL
REL
REL
REL
REL
OCLR
OCLR
OCLR
REL
REL
REL
REL
SEX SEX SEX SEX
A
(1) NEW TYPE "A" FIXTURE IN PLACEOF RELOCATED FIXTURE
REL
A
(1) NEW TYPE "A" FIXTURE IN PLACEOF RELOCATED FIXTURE
A
A
REPLACE EXISTINGFIXTURE WITH NEWTYPE "A" FIXTURE
OCLR
OC OC
OC
SDL
REMOVE AND BLANK OFFEXISTING SWITCHES
CONNECT TO EXISTINGLIGHTING CIRCUITWITHIN ROOM
1. EXTEND THE EXISTING LIGHTING CIRCUITS IN THIS AREA FORRELOCATIONS AND NEW FIXTURE ADDITIONS
EX/EMEX/EM
204HOFFICE
204GASST DIR.
204FDIR.OFFICE
204DSTORAGE
204AOFFICE
204BOFFICE
204CCONFERENCE
204EOF OFFICE SUITE
204ECOPY/WORK RM.
EX
EX
NEXN
EX
EX
EX
(2)
(2)
(2)
(2)
2E1.1
EOF SUITE POWER PLAN
EX EXEX
EX EX
EX
EX
(2)NN
EX+
EX
EX
EXEX
(2)+(2)+
(2)++
(2)
N
NN
N
N
N
N
N
N
N N N NNN
N
N
N
N
N
N
N
N
N
N
NN
N
NN
N
N
N
N
N
N
REMOVE EXISTINGSURFACE RACEWAY
REMOVE EXISTINGSURFACE RACEWAY
REPLACE WITH NEWQUAD RECEPTACLE
REPLACE WITH NEWRECEPTACLE
REPLACE WITH NEWRECEPTACLE
REPLACE WITH NEWRECEPTACLE
RP1A1
EX
REMOVE
RP1A7
S
S RELN N
RP1A4
RP1A
S REL
S
RP1A5
EX
REMOVE
EX
RP1A6
S
S REL SREL
S
FEX
F
N
(2)N
RP1A3
EX
BLANK OFFRP1A
2
N
RP1A9
(2)N
(2)+N
+
FOR TV
(2)N
(2)N
(4)
AT FACE OFCEILING TILE
EX
+
BLANK OFF COAXIALCABLE JACK
(2)N
+EXEX
BLANK OFFCOAXIALCABLE JACK
1. EXISTING DATA OUTLETS IN THIS EFO SUITE DO NOT REQUIRETESTING, TRACING, OR LABELING
MOUNT BELOWTV OUTLETS
F
COM
PUTE
RCO
MPU
TER
COM
PUTE
R
ELEV.
RWC
RWC
RWC
RWCRWC
RWC
RWCRWC
DN12R
DN11R
DN7R
ELECT.RM
STORAGE
STORAGE
DN7R
DN12R
DN12R
DN11R
DN12R
F.E.
207207ACLOSET
207BOFFICE
207CCLOSET
207DLOUNGE
207EOFFICE
STOR.208C
STOR.207F
OFFICESUITE
208OFFICESUITE
208AOFFICE
208BOFFICE
208DOFFICE
209BOFFICE
209AOFFICE
209COFFICE
209DOFFICE
EOF SUITE210
OFFICE210E
95 SF
210BOFFICE
210AOFFICE
210DOFFICE
210COFFICE
M E Z Z A N I N E A R E A B E L O W
211C
UPPERLANDING
213B
INTERMEDIATELANDING
213A
TESTING206
206B 206A
206C
STAIRST-A2
STAIRST-B2
UNIVERSITYCENTER
200
200AOFFICE
200BOFFICE
200COFFICE
200D
200E
UNIVERSITYCENTER
201
201AOFFICE
201BOFFICE
201CCONF.
201D
OFFICE202B
87 SF
OFFICE202A
87 SF
OFFICE202C
169 SFOFFICE
202D
103 SF
202
290 SFSTUDENT LIFE
203
358 SF
OFFICE203C
122 SFOFFICE203B
174 SF
STOR.203A
68 SF
CONF.203D
312 SF
CORRIDOR '200'C-200
CAP CENTER212D
STUDENT AFFAIRS
209EOFFICE72 SF
209OIRA
SUITE
COM
PUTE
RCO
MPU
TER
COM
PUTE
R
E211C
3E1.1
CAP CENTER LIGHTING PLAN
OFFICE212A
OFFICE212B
OFFICE212C
EXTSEX
SEX
A A A
EXEXEX
EX EX EX
EXEX
SS
RECONNECT TOCIRCUITS ANDSWITCH LEGS INTHIS AREA,RE-CIRCUIT UPTO (6) LIGHTSTOACCOMMODATESWITCHING
A A A
OCLR
SDL SDL SDL
OCLR
OCLR
LROCOC
OC OC
EXISTING EXIT SIGN
REWIRE EXISTINGTO ACCOMMODATENEW SWITCHINGAND OCCUPANCYSENSORS
EXISTING EXIT SIGNREMOVE (1) EXISTING 2 X 4 LIGHT INEACH OF THREE OFFICES, PROVIDENEW LIGHTS AS SHOWN
CAP CENTER212
1. EXTEND THE EXISTING LIGHTING CIRCUITS IN THIS AREA FORRELOCATIONS AND NEW FIXTURE ADDITIONS
NEW SWITCHES
COM
PUTE
RCO
MPU
TER
COM
PUTE
R
E211C
OFFICE212A
OFFICE212B
OFFICE212C
4E1.1
CAP CENTER POWER PLAN
F
EX
EX
EX
EXEXEX
EX
EX
EX
EXEX
EX
EX
(2) (2) (2)
EX
(2)
212TV
EX+50"
N
N N N
N
N
NN
N
N
N N
N
N
EX
N
N N N
FREL
EXISTING TVLOCATION
EXISTINGPANEL "LPS-1"
EX
S S
SREL
SREL
N
LPS-117
LPS-116
LPS-114
EXEX +36" +36"
EX
EX
LPS-115
(2)N
CAP CENTER212
EX
(4)
AT FACE OFCEILING TILE
1. TEST, TRACE, AND RE-LABEL EXISTING DATA OUTLETS IN THIS CAPCENTER AREA. BASE PRICING ON TWO CAT6 CABLES PER EXISTINGDATA OUTLETS
KITCHEN/STORAGE
M E Z Z A N I N E R E A D I N G A R E A
UP11R
UP12R
DN5R
DN5R
DN5R
DN5R
UP12R
UP12R
RAMP DN
RAMP DN
DN4R
DN4R
DN4R
DN4R
JAN.E.W.C.
FILES
RAMP DN.182 S.F.
T.
R.P.
R.P.
DISP
LAY
CASE
OFFICEB162
OFFICEB161
OFFICEB164
OFFICEB165
OFFICEB160
OFFICEB159
OFFICEB157
OFFICEB155
OFFICEB154
OFFICEB158
OFFICEB166
SECRETARYB163
ROLL-DOWNGATE
ROLL-DOWNGATE
CLUB HUBROOM
B122
CORRIDOR 'C1'C-C1
CORRIDOR 'B1'C-B1
OFFICEC111
OFFICEC110
OFFICEC108
OFFICEC107
OFFICEC105
OFFICEC104
OFFICEC112
OFFICEC114
OFFICEC116
OFFICEC117
OFFICEC118
OFFICEC119
OFFICEC120
OFFICEC121
OFFICEC122
OFFICEC109
OFFICEC115
OFFICEC124
FACULTY OFFICESWAITING AREA
C123
ROLLDOWNGATE
OFFICEC103
WORKC102
ELEC.M166
COPYM167
OFFICEM168
OFFICEM172
OFFICEM169
OFFICEM171
FILE/WAITM173
COPYM170
C101
107106 108 109
STAIRST-A1
STAIRST-B1
OFFICEB153
OFFICEB151
OFFICEB150
OFFICEB148
OFFICEB149
B152ADJUNCTOFFICE
FACULTY OFFICEWAITING
B167
OFFICEB141
OFFICEB138
OFFICEB137
OFFICEB142
PRESIDENT OFFICEB145
OFFICEB134
CONF. RM.B118C
OFFICEB136 DINING ROOM
A103
FACULTY DININGA102
VESTIBULEA101
DINING EXTENSIONA120
STUDENT COMMONSB101
ELEC.B174
MECH.B170
SERVERB173
SECURITYB172
ELEV
ELEV.MACH. RM.
B171
MENA125
WOMENA124
SERVER/DATA CENTER
B120
NETWORKCENTER
B119
STOR.B122A
WOMEN
CORRIDOR'A1'
C-A1
CORRIDOR'C2'
C-C2
MEN
100101102103104
VAULTB140
STOR.B169
SECRETARYB135
OFFICEB131
SECRETARY
IRAOFFICES
B118
OFFICEB118B
OFFICEB118A
B118D
OFFICEB132
B171
OFFICEB144
OFFICEB146
COPYB143
OFFICEB147
STOR.B133
FILESB146A
B139
SECRETARYC106
SECRETARYC113
B117
B116
CONF. RM.A116
SNACK BAR/GAME ROOM
A118
A103A
KITCHENPREP
A114
REFRIG.A114A
FREEZERA114B
OFFICEA114C
KITCHENSERVICE
A109
A109A
A109B
A109CA109DA109E
SERVINGA115
DISHA104
VENDING AREA OF WORKSEE DRAWING '1/E1.1' FOR THE"EOF SUITE LIGHTING PLAN"SEE DRAWING '2/E1.1' FOR THE"EOF SUITE POWER PLAN"
AREA OF WORKSEE DRAWING '3/E1.1' FOR THE"CAP CENTER LIGHTING PLAN"SEE DRAWING '4/E1.1' FOR THE"CAP CENTER POWER PLAN"
EXISTING PANEL "RP-1"
6E1.1
SECOND FLOOR COLLEGE CENTER KEY PLAN5E1.1
FIRST FLOOR COLLEGE CENTER KEY PLAN
EXISTING IT RACK
NEW IT RACKBY OWNER
EXISTING IT ROOM
MAIN COMPUTER ROOM 1IT SEE
NOTE #19
1E2.1
PARTIAL SINGLE LINE DIAGRAMSCALE: N.T.S.
RP1ANEW
PANEL
RP1NEW 3 #4, 1 #8, 1.5"C,COPPER MC CABLE
EXISTING FEEDERTO REMAIN
EXISTINGPANEL
2E2.1
IT RISER DIAGRAMSCALE: N.T.S.
1ST FLOOR MAIN COMPUTER ROOM, SEE"FIRST FLOOR COLLEGE CENTER KEY PLAN"
2ND FLOOR IT ROOM, SEE "SECOND FLOORCOLLEGE CENTER KEY PLAN"
EXISTING FIBER TRAY
TERMINATE NEW FIBER INEXISTING FIBER TRAY
FIRESTOP ALLPENETRATIONS
NEW 12 STRAND SINGLE MODEFIBER, PLENUM RATED
NEW FIBER TRAY
NEW 48U, 2-POST RACK
NEW 48 PORT, CAT6APATCH PANEL
(2)NEW CAT6ACABLES
CONTRACTOR TOTERMINATE ALL NEWCAT6A CABLE RUNSAT NEW PATCHPANEL. PROVIDETESTING ANDCERTIFICATION
QUANTITY OF CABLES AS PERNUMBER IN PARENTHESIS
NEW DATA OUTLET CONSISTINGOF JACK, OUTLET BOX, COVERPLATE, FINAL CONNECTIONSAND TESTING
1. PERFORM ALL TESTING AND SUBMIT FINAL CERTIFIED TESTINGREPORT TO OWNER
2. RUN ALL NEW CABLING FROM LOCATION SHOWN TO THE 2NDFLOOR 'IT ROOM'
BY OWNER
BY CONTRACTOR
PROVIDE NEW 60/3 BREAKERIN EXISTING PANEL "RP1"
F
SREL
OC
S S3 S4
SDE
SDL
SOC
LR
N
EX
U
N
N
EX
(2)
ELECTRICAL NOTES1) PERFORM ALL WORK IN STRICT ACCORDANCE WITH THE LATEST ADOPTED EDITIONS OF THE NATIONAL ELECTRICAL CODE (NEC), OSHA REQUIREMENTS, ALL FEDERAL, STATE, AND LOCAL
CODES AND ALL OWNER REQUIREMENTS.
2) INCLUDE ALL TEMPORARY POWER AND LIGHTING, PERMIT, LICENSE, AND INSPECTION COSTS IN BID.
3) VERIFY EXACT LOCATIONS AND MOUNTING OF ALL LUMINAIRES, SWITCHES, RECEPTACLES, OUTLETS, FIRE ALARM, AND OTHER EQUIPMENT WITH ARCHITECTURAL DRAWINGS AND IN THEFIELD PRIOR TO ROUGH IN.
4) VERIFY ELECTRICAL RATINGS, CONNECTION REQUIREMENTS, AND EXACT LOCATIONS OF ALL MECHANICAL, KITCHEN, AND OTHER UTILIZATION EQUIPMENT (WHERE APPLICABLE) IN FIELDPRIOR TO PURCHASING ASSOCIATED ELECTRICAL EQUIPMENT. PROVIDE A COMPLETE AND WORKING INSTALLATION.
5) THE TERM "PROVIDE" MEANS, "FURNISHED AND INSTALLED BY THE ELECTRICAL CONTRACTOR", AND THE TERMS "CONTRACTOR" AND "E.C." MEAN "ELECTRICAL CONTRACTOR", UNLESSINDICATED OTHERWISE. ALL WORK INDICATED ON THE ELECTRICAL DRAWINGS AND ELECTRICAL SPECIFICATIONS IS BY THE E.C. (UNLESS INDICATED OTHERWISE) AND IS NEW (UNLESSINDICATED OTHERWISE). WHERE THE PROJECT IS PERFORMED BY MULTIPLE PRIME CONTRACTORS UNDER "MULTIPLE PRIME BIDS" THIS DESIGNATES THE WORK BY THE ELECTRICAL PRIMECONTRACTOR. WHERE THE PROJECT IS PERFORMED BY A SINGLE OVERALL CONTRACTOR UNDER "LUMP SUM BIDS" THIS APPROXIMATELY DESIGNATES THE WORK BY THE ELECTRICALTRADE SUBCONTRACTOR (EXACT DIVISION OF TRADE SUBCONTRACTOR WORK IS THE SOLE RESPONSIBILITY OF THE SINGLE OVERALL CONTRACTOR; TRADE SUBCONTRACTOR WORKDIVISION SHOWN ON THE DRAWINGS/SPECIFICATIONS IS FOR REFERENCE AND CONVENIENCE ONLY).
6) COORDINATE ALL REQUIRED SHUTDOWNS WITH THE OWNER (AND UTILITY COMPANY WHERE APPLICABLE) A MINIMUM OF FOURTEEN (14) DAYS IN ADVANCE. INCLUDE OVERTIME COSTS INBID TO PERFORM ALL SHUTDOWNS (INCLUDING SHUTDOWNS FOR AREAS WHICH MAY BE UNOCCUPIED DURING CONSTRUCTION) AFTER NORMAL WORKING HOURS AS COORDINATED WITHTHE OWNER. NO EXTRA CLAIMS OR COMPENSATION WILL BE GRANTED FOR OVERTIME COSTS ASSOCIATED WITH PERFORMING SHUTDOWNS.
7) PROVIDE MOUNTING HEIGHTS OF EQUIPMENT AS REQUIRED BY ALL APPLICABLE LOCAL, STATE, AND FEDERAL CODES AND STANDARDS, INCLUDING ALL APPLICABLE DISABLED(HANDICAPPED) ACCESS CODES AND THE AMERICANS WITH DISABILITIES ACT (ADA). CONTACT ANY AND ALL AUTHORITIES HAVING JURISDICTION TO VERIFY REQUIRED MOUNTING HEIGHTS.
8) VERIFY ALL UTILITY (ELECTRIC, TELEPHONE, DATA, CABLE TELEVISION, ETC. WHERE APPLICABLE) REQUIREMENTS IN WRITING WITH EACH UTILITY COMPANY AND OBTAIN APPROVALS FROMALL UTILITIES (INCLUDING SUBMITTING ANY REQUIRED SERVICE APPLICATIONS AND SHOP DRAWINGS ON SERVICE-RELATED EQUIPMENT TO UTILITIES) PRIOR TO ROUGH-IN OR PURCHASINGANY SERVICE RELATED EQUIPMENT. THE ELECTRICAL CONTRACTOR IS SOLELY RESPONSIBLE TO FULLY COORDINATE AND VERIFY SERVICE REQUIREMENTS WITH UTILITY COMPANIES(INCLUDE ALL COSTS IN BID). NO EXTRA CLAIMS OR COMPENSATION WILL BE GRANTED UNDER ANY CIRCUMSTANCE ASSOCIATED WITH FAILURE TO FULLY COORDINATE WITH OR OBTAINFULL APPROVALS FROM UTILITY COMPANIES.
9) PERFORM ALL WORK IN PHASES AND SEQUENCES AS DIRECTED BY THE SPECIFICATIONS. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS. FULLY COORDINATEPHASES/SEQUENCES IN DETAIL WITH ALL CONTRACTORS/TRADES, THE ARCHITECT, AND THE OWNER PRIOR TO PERFORMING WORK AND INCLUDE ALL COSTS IN BID.
10) WHERE EXISTING WIRING TO BE REMOVED (AS INDICATED ABOVE) OR OTHERWISE AFFECTED BY CONSTRUCTION (BY ANY CONTRACTOR OR TRADE, INCLUDING GENERAL CONSTRUCTION,MECHANICAL, PLUMBING, FIRE PROTECTION, ELECTRICAL, ETC.) FEEDS LOADS WHICH REMAIN OR FEEDS LOADS IN ADJACENT OR OTHER AREAS NOT WITHIN THE SCOPE OF WORK, THEWIRING SHALL REMAIN. RELOCATE, EXTEND, AND/OR RE-FEED THE EXISTING WIRING AS REQUIRED TO MAINTAIN SERVICE, UNLESS INDICATED OTHERWISE. BASE PRICING ON THEASSUMPTION THAT RELOCATING, EXTENDING, AND RE-FEEDING IS NECESSARY IN ALL AREAS OF DEMOLITION AND ALL AREAS OF PROPOSED NEW WORK (BY ANY TRADE), UNLESSACTUALLY VERIFIED OTHERWISE BY THE ELECTRICAL CONTRACTOR. INCLUDE ALL COSTS IN BID.
11) WHERE RE-FEEDING EXISTING ELECTRICAL CIRCUITS AND LOADS, VERIFY ALL REQUIREMENTS IN THE FIELD AND INCLUDE ALL COSTS IN BID. VERIFY EXACT CONDUCTOR SIZES ANDAMPACITY, EXISTING CIRCUIT BREAKER AND/OR FUSE AMPS, LOAD NAMEPLATE RATINGS, CONDUIT SIZES, ETC.. FOR EQUIPMENT TO BE RE-FED, PROVIDE ALL NEW WIRING DIRECTLY TOTHE EQUIPMENT. DO NOT REUSE EXISTING WIRING TO RE-FEED EQUIPMENT, UNLESS SPECIFICALLY INDICATED ON THE DRAWINGS.
12) INFORMATION REGARDING EXISTING CONDITIONS AND EQUIPMENT AND ALL INFORMATION REGARDING REMOVALS (INCLUDING INFORMATION REGARDING THE SCOPE OF REMOVALS ONARCHITECTURAL DRAWINGS) INDICATES GENERAL CONDITIONS AND ARE A GUIDE TO PRICING ONLY. PRIOR TO SUBMITTING BID, VISIT THE PROJECT SITE AND VERIFY ALL EXISTINGCONDITIONS AND EQUIPMENT, ALL REMOVALS AND REQUIREMENTS, AND ALL TIE-INS TO EXISTING EQUIPMENT AND WIRING IN DETAIL. INCLUDE ALL COSTS IN BID. NO EXTRA CLAIMS ORCOMPENSATION WILL BE GRANTED FOR NOT FIRST VERIFYING ALL CONDITIONS.
13) FOR ALL NEW CIRCUIT BREAKERS IN EXISTING BRANCH AND DISTRIBUTION PANELS, PROVIDE CIRCUIT BREAKERS MATCHING AND COMPATIBLE WITH EXISTING CIRCUIT BREAKERS.PROVIDE WITH SHORT CIRCUIT INTERRUPTING RATINGS EQUAL TO OR EXCEEDING THE HIGHEST RATED EXISTING BRANCH CIRCUIT BREAKER IN THE PANEL. CIRCUIT BREAKER TYPESINDICATED ON THE DRAWINGS (WHERE APPLICABLE) ARE GUIDES TO PRICING ONLY. VERIFY EXACT TYPE AND ALL REQUIREMENTS IN FIELD PRIOR TO RELEASING EQUIPMENT.
14) FOR ALL WIRING AND WORK INDICATED, INCLUDING ALL SYSTEMS (POWER, LIGHTING, FIRE ALARM, CONTROL, SIGNAL, SOUND, TELECOMMUNICATIONS, DATA, AND ALL OTHER SYSTEMS,WHERE APPLICABLE), PROVIDE ALL NEW CONDUITS, RACEWAYS, OUTLETS, AND CONDUCTORS, INCLUDE ALL COSTS IN BID. WHERE EXISTING CONDUITS AND RACEWAYS ARE DETERMINEDBY THE ENGINEER TO BE IN ADEQUATE CONDITION, AND WHERE SPECIFICALLY APPROVED BY THE OWNER, ARCHITECT, AND ENGINEER, EXISTING CONDUITS AND RACEWAYS MAY BEREUSED. PROVIDE A SEPARATE GROUNDING CONDUCTOR, IN ADDITION TO ALL OTHER GROUNDING CONDUCTORS SPECIFIED, AND BOND TO ALL RACEWAYS, CONDUITS, BOXES, ANDOUTLETS WHERE RACEWAYS ARE REUSED. DO NOT DEPEND ON EXISTING CONDUITS/RACEWAYS FOR GROUNDING PATHS. REUSE EXISTING CONDUCTORS ONLY WHERE SPECIFICALLYINDICATED ON THE DRAWINGS.
15) PROVIDE ENGRAVED LAMINATED PLASTIC NAMEPLATES FOR ALL ELECTRICAL EQUIPMENT (INCLUDING, BUT NOT LIMITED TO, SAFETY SWITCHES, ENCLOSED CIRCUIT BREAKERS, BRANCHPANELS, DISTRIBUTION PANELS/SWITCHBOARDS, TRANSFORMERS, FUSED EQUIPMENT, POWER OUTLETS, THERMAL OVERLOAD SWITCHES, CONTACTORS, TIME CLOCKS, PHOTOCELLS,METER SOCKETS, MODULAR METER CENTERS, FIRE ALARM DEVICES, LIGHTING CONTROLLERS, DIMMING CABINETS, CAPACITORS, SNOW MELTING EQUIPMENT, GENERATORS, MOTORCONTROL CENTERS, MOTOR CONTROLS, HIGH VOLTAGE EQUIPMENT, SWITCHES AND RECEPTACLES SERVING EQUIPMENT, ETC., WHERE APPLICABLE), REFER TO SPECIFICATIONS FORINFORMATION. PROVIDE ENGRAVED PLASTIC NAMEPLATES FOR ALL CONVENIENCE RECEPTACLES.
16) COMPLETELY SEAL AND FIRE STOP ALL PENETRATIONS OF ALL FIRE AND/OR SMOKE RATED WALLS, FLOORS, CEILINGS, AND ANY OTHER CONSTRUCTION (INCLUDING ALL WALLS REQUIREDTO BE RATED BY CODE) TO A RATING MATCHING OR EXCEEDING THE FIRE RATING OF THE CONSTRUCTION. COMPLETELY SEAL AND WEATHERPROOF ALL PENETRATIONS OF EXTERIOR, ATOR BELOW GRADE, AND WET LOCATION WALLS AND FLOORS AND ROOF PENETRATIONS. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR INFORMATION ON FIRE RATINGSOF BUILDING CONSTRUCTION AND INCLUDE ALL COSTS IN BID. COMPLY WITH AND INSTALL FIRE STOPPING IN ACCORDANCE WITH ALL APPLICABLE FIRE RATING CODES AND STANDARDS(INCLUDING THE NEC, NFPA, IBC, AND THE UL "FIRE RESISTANCE DIRECTORY").
17) PROVIDE 120 V POWER TO ALL SECURITY AND DOOR HARDWARE. COORDINATE ALL REQUIREMENTS WITH ARCHITECTURAL DOCUMENTS, THE OWNER, AND SECURITY SUPPLIER. OBTAINPOWER FROM A SUITABLE NEARBY BRANCH CIRCUIT.
18) PROVIDE NEC AND OSHA APPROVED TEMPORARY LIGHTING AT ALL TEMPORARY PROTECTED EGRESS COVERS (I.E. AT CERTAIN EXITS DURING CONSTRUCTION). PROVIDE TEMPORARYCODE APPROVED ILLUMINATED EXIT SIGNS AS REQUIRED TO IDENTIFY THE ENTIRE TEMPORARY EGRESS PATH. PROVIDE TEMPORARY EMERGENCY LIGHTING (UTILIZING BATTERY UNITAND/OR REMOTE HEADS) AS REQUIRED TO SATISFY CODE REQUIREMENTS. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR INFORMATION AND LOCATIONS.
19) PROVIDE 3#8, 1"C FROM NEW PANEL RP1A TO NEW IT RACK. PROVIDE 30 AMP , 120/208V, SINGLE PHASE RECEPTACLE NEXT TO RACK. OWNER MAY REQUIRE NEW CIRCUIT RUN FROM THESECOND FLOOR IT RACK TO THE MAIN IT ROOM ON THE FIRST FLOOR. INCLUDE COSTS IN BID FOR EITHER DESTINATION. AT THE MAIN IT ROOM ON THE FIRST FLOOR, PROVIDE A 30 AMP 2POLE BREAKER AND INSERT INTO AN EXISTING BRANCH PANEL.
ELECTRICAL SYMBOL LIST20 A, 277/120 V SWITCH, SINGLE POLE (S), THREE-WAY (S-3), AND FOUR-WAY (S-4), RESPECTIVELY, SPECIFICATION GRADE, FLUSH MOUNTED, FINISH AND COVER PLATE AS PER ARCHITECT
120 V INCANDESCENT ELECTRONIC LOW VOLTAGE OR CFL/LED DIMMER SWITCH (S-DE), SINGLE POLE (RATED 600W INCANDESCENT, 300W ELECTRONIC LOW VOLTAGE, AND 250W COMPACTFLUORESCENT OR LED), SLIDE TYPE (WITHOUT ON/OFF TOGGLE OR ROCKER SWITCH), FULLY RATED, SPECIFICATION GRADE, FLUSH MOUNTED, LOW PROFILE, FINISH AND COVER PLATE AS PERARCHITECT, FOR DIMMING MAXIMUM OF 250 W COMPACT FLUORESCENT OR LIGHT EMITTING DIODE (LED) MODULES, OF A TYPE COMPATIBLE WITH THREE-WAY OPERATION VIA REMOTESTANDARD THREE-WAY SWITCHES, UTILIZE LUTRON #DVELV-303P-** OR #DVCL-253P-** (OR EQUIVALENT BY HUBBELL OR LEVITON); REFER TO SPECIFICATIONS WHERE GANGED WITH SINGLEPOLE, THREE-WAY, OR FOUR-WAY SWITCHES; WHERE USED WITH CFL/LED LIGHTING SEE LUMINAIRE SCHEDULE AND FULLY COORDINATE IN DETAIL WITH LUMINAIRE AND DIMMERMANUFACTURER (INCLUDE COSTS IN BID TO USE DIFFERENT TYPES OF DIMMER SWITCHES AS APPLICABLE FOR EACH DIFFERENT LUMINAIRE TYPE CONTROLLED)
0-10 V, 30 Ma, 8 A, 120/277 V, LIGHT EMITTING DIODE (LED) DRIVER OR FLUORESCENT ELECTRONIC BALLAST DIMMER SWITCH (S-DL), SINGLE POLE, SLIDE TYPE (WITHOUT ON/OFF TOGGLE ORROCKER SWITCH), FULLY RATED, SPECIFICATION GRADE, FLUSH MOUNTED, LOW PROFILE, FINISH AND COVER PLATE AS PER ARCHITECT, OF A TYPE COMPATIBLE WITH THREE-WAY OPERATIONVIA REMOTE STANDARD THREE-WAY SWITCHES; LUTRON #DVSTV-** (OR EQUIVALENT), UTILIZE EXACT RESPECTIVE DIMMER SWITCH TYPE COORDINATED WITH DIMMABLE LED DRIVERS ORDIMMABLE FLUORESCENT BALLASTS IN CONTROLLED LUMINAIRE (FULLY COORDINATE IN DETAIL WITH LUMINAIRE AND DIMMER MANUFACTURER AND INCLUDE COSTS IN BID TO USE DIFFERENTTYPES OF DIMMER SWITCHES AS APPLICABLE FOR EACH DIFFERENT LUMINAIRE TYPE CONTROLLED); WHERE CIRCUIT LOAD EXCEEDS 8 A UTILIZE #PP-DV POWER PACK(S) AS APPLICABLE TOFACILITATE LOAD
OCCUPANCY/VACANCY SENSOR LIGHTING CONTROL WITH INTEGRAL PUSH BUTTON (S-OC), FLUSH MOUNTED ON WALL (ON FLUSH MOUNTED OUTLET BOX), SELF-CONTAINED "STAND-ALONE"TYPE (SINGLE SENSOR FOR LOCAL LIGHTING CONTROL OF A SINGLE CIRCUIT ONLY), MULTI-TECHNOLOGY PASSIVE INFRARED (PIR) AND ULTRASONIC TYPE WITH INTEGRAL SWITCHING RELAY,RATED MINIMUM 800 W, 1,200 VA FOR 120 V OPERATION AND RATED MINIMUM 2,700 VA FOR 277 V OPERATION, SINGLE POLE, NOMINAL 93 m2 (1,000 SQ FT) COVERAGE, MEETING NEMA WD7STANDARD, INTEGRAL SELECTABLE AMBIENT LIGHT LEVEL SENSOR, SELECTABLE AUTOMATIC (OCCUPANCY SENSOR WITH "OVERRIDE-TO-OFF" PUSH BUTTON) OR MANUAL (VACANCY SENSORWITH "MANUAL-ON" PUSH BUTTON) MODES, SPECIFICATION GRADE, WHITE FINISH, EATON/COOPER #ONW-D-1001-MV-* (OR EQUIVALENT)
OCCUPANCY SENSOR LIGHTING CONTROL [OC], FLUSH MOUNTED IN CEILING, FOR COMMON CONTROL OF LIGHTING (MULTIPLE SENSORS FOR LIGHTING CONTROL IN CONJUNCTION WITH REMOTELIGHTING CONTROL RELAY MODULE(S)), MULTI-TECHNOLOGY PASSIVE INFRARED (PIR) AND ULTRASONIC TYPE, 360 DEGREE NOMINAL 186 m2 (2,000 SQ FT) COVERAGE, MEETING NEMA WD7STANDARD, INTEGRAL SELECTABLE AMBIENT LIGHT LEVEL SENSOR, SPECIFICATION GRADE, WHITE FINISH; PROVIDE LOW VOLTAGE CONTROL WIRING BETWEEN SENSOR AND CONTROL RELAY
LIGHTING CONTROL RELAY MODULE [LR], INTERCONNECT (UTILIZING LOW VOLTAGE CONTROL WIRING) WITH OCCUPANCY SENSORS AS SHOWN ON THE DRAWINGS, RATED 1,800 VA FOR 120 VOPERATION AND RATED 4,800 VA FOR 277 V OPERATION, SINGLE POLE, SPECIFICATION GRADE; PROVIDE A MINIMUM OF ONE (1) RELAY PER CIRCUIT CONTROLLED (WHERE MULTIPLE RELAYS ARESHOWN OR OTHERWISE APPLICABLE, PROVIDE EXACT QUANTITY NEEDED [INCLUDING ADDITIONAL RELAYS OR MODULES AS APPLICABLE] TO SUPPORT THE SWITCHING CONTROL SHOWN ONDRAWINGS IN CONJUNCTION WITH THE QUANTITY OF CONTROLLING SENSORS INVOLVED), INTERCONNECT AUXILIARY CONTACTS FOR SIMULTANEOUS CONTROL); WHERE WALL SWITCHES(SINGLE POLE, THREE-WAY, OR FOUR-WAY) ARE INDICATED ALONG WITH OCCUPANCY SENSOR ON THE DRAWINGS, ARRANGE AND INTERCONNCT SWITCHES (AS RECOMMENDED BY OCCUPANCYSENSOR MANUFACTURER) TO OPERATE AS MANUAL "OVERRIDE-TO-OFF" UNLESS SPECIFICALLY INDICATED OTHERWISE
LUMINAIRE, TYPE AS INDICATED ON THE LUMINAIRE SCHEDULE
EXIT SIGN. NEW. UNLESS INDICATED OTHERWISE
NEW 20 A, 120 V DUPLEX RECEPTACLE (NEMA 5-20R), (RECEP-N) SPECIFICATION GRADE, TAMPER RESISTANT, FLUSH MOUNTED, FINISH AND STAINLESS STEEL COVER PLATE AS PER OWNER, (+)INDICATES ABOVE COUNTER MOUNTING HEIGHT, (*) INDICATES MOUNTED HIGH ON WALL AT DISPLAY/SCREEN OR ABOVE BOARD
EXISTING RECEPTACLE TO REMAIN (RECEP-EX)
20 A, 120 V DUPLEX GROUND FAULT CIRCUIT INTERRUPTER (GFCI) TYPE/PROTECTED RECEPTACLE (NEMA 5-20R), SPECIFICATION GRADE, TAMPER RESISTANT, FLUSH MOUNTED, FINISH ANDCOVER PLATE AS PER ARCHITECT, (+) INDICATES ABOVE COUNTER MOUNTING HEIGHT, (WP) INDICATES WEATHER-RESISTANT TYPE RECEPTACLE MOUNTED IN A WEATHERPROOF OUTLET BOXWITH SINGLE SPRING-LATCHED WEATHERPROOF-WHILE-IN-USE COVER; FEED-THROUGH PROTECTION OF STANDARD TYPE RECEPTACLES FROM OTHER GFCI RECEPTACLES IS NOT ACCEPTABLE;PROTECTION OF STANDARD TYPE RECEPTACLES IN READILY ACCESSIBLE LOCATIONS FROM GFCI CIRCUIT BREAKERS IS NOT ACCEPTABLE (SEE BELOW FOR INACCESSIBLE RECEPTACLES); FORINACCESSIBLE RECEPTACLES (LOCATIONS WHICH ARE NOT READILY ACCESSIBLE AS PER THE NEC, FOR EXAMPLE WHERE LOCATED BEHIND EQUIPMENT, APPLIANCES, OR OBSTACLES) THE USEOF GFCI TYPE RECEPTACLES IS PROHIBITED AND PROTECTION OF STANDARD TYPE RECEPTACLES FROM GFCI CIRCUIT BREAKER MUST BE USED (IDENTIFY RECEPTACLES AS PROTECTED AS PERTHE NEC)
20 A, 120 V COMBINATION DUPLEX RECEPTACLE (NEMA 5-20R) AND DUPLEX UNIVERSAL SERIAL BUS (USB) CHARGER (U), WITH TWO (2) INTEGRAL 3.6 A, 5 VDC USB 2.0 PORTS (WITHOUT DATACAPABILITY) POWERED FROM INTERNAL DIGITAL DC POWER SUPPLY DESIGNED TO OPTIMIZE PERIPHERAL DEVICE CHARGING, SPECIFICATION GRADE, TAMPER RESISTANT, FLUSH MOUNTED,FINISH AND COVER PLATE AS PER OWNER, (+) INDICATES ABOVE COUNTER MOUNTING HEIGHT, (*) INDICATES MOUNTED HIGH ON WALL AT DISPLAY/SCREEN
NEW QUADRUPLEX ("DOUBLE DUPLEX", "QUAD") RECEPTACLE (QUAD-N), WITH RECEPTACLE TYPE AS INDICATED
EQUIPMENT CONNECTION [X], REFER TO THE EQUIPMENT SCHEDULE AND THE EQUIPMENT NOTES FOR INFORMATION
EQUIPMENT DESIGNATION (HEXAGON), FOR REFERENCE TO THE EQUIPMENT SCHEDULE
ELECTRICAL PANEL, REFER TO THE SINGLE LINE DIAGRAM AND RESPECTIVE PANEL SCHEDULE
INDICATES HOME RUN OF WIRING TO PANEL AND CIRCUIT INDICATED
NEW TELEPHONE/DATA OUTLET, (TRIANGLE-N). FLUSH MOUNTED, NUMBER INSIDE PARENTHESIS (EXAMPLE (2)) INDICATES THE NUMBER OF CATEGORY 6A CABLES AND NUMBER OF JACKS PEROUTLET. ALL TELEPHONE/DATA WIRING, CONDUIT, JACKS, COVER PLATES, TESTING AND FINAL CERTIFICATIONS ARE BY THE CONTRACTOR. RUN DATA LINES FROM LOCATION SHOWN TO ITROOM. REFERENCE LEGENDS & IT RISERS. PROVIDE OWNER APPROVED 1-GANG OUTLET BOX IN WALL AND ONE (1) 1" CONDUIT RUN FROM OUTLET STUBBED AND CAPPED INTO NEARBYACCESSIBLE CEILING SPACE, (+) INDICATES ABOVE COUNTER MOUNTING HEIGHT OR WALL MOUNTED TELEPHONE MOUNTING HEIGHT (COORDINATE WITH ARCHITECT/OWNER DURINGCONSTRUCTION), (*) INDICATES MOUNTED HIGH ON WALL AT TELEVISION OR ABOVE BOARD; WITH COVER PLATES AND JACKS BY CONTRACTOR AS PER SPECIFICATIONS.
EXISTING DATA OUTLET.
FIRE ALARM AUDIO/VISUAL HORN/STROBE. "EX" INDICATES EXISTING TO REMAIN. "REL" INDICATES RELOCATE AND EXTEND WIRING UNDER SUPERVISION OF TYCO, OWNER'S FIRE ALARMVENDOR.
FIRE ALARM VISUAL ONLY STROBE. PROVIDE OUTLET BOX IN WALL AND CONDUIT STUB UP TO CEILING. HORN SHALL BE FURNISHED AND INSTALLED BY TYCO, OWNER'S FIRE ALARM VENDORUNDER A SEPARATE CONTRACT.
FIRE ALARM SMOKE DETECTOR (S-REL). "REL" INDICATES RELOCATE AND EXTEND WIRING UNDER SUPERVISON OF TYCO, OWNER'S FIRE ALARM VENDOR.