enve 302 environmental engineering unit processesbilge.alpaslan/enve 302... · 2012. 6. 1. · aotr...
TRANSCRIPT
![Page 1: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/1.jpg)
1
ENVE 302
Environmental Engineering Unit Processes
Assist. Prof. Bilge Alpaslan Kocamemi
Marmara University
Department of Environmental Engineering
Istanbul, Turkey
CHAPTER: 7
Aeration Systems
Air Requirement Calculations
![Page 2: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/2.jpg)
AERATION SYSTEMS
Because of low solubility of oxygen , low rate of oxygen transfer;
sufficient oxygen to meet the requirement of aerobic waste
treatment does not enter water through normal air-water
interface.
To transfer the large quantites of oxygen ;
additional interfaces must be formed
air or oxygen can be introduced into liquid
the liquid in the form of droplets can be exposed to the atmosphere 1
![Page 3: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/3.jpg)
Factors Affecting Oxygen Transfer
The rate of gas transfer is generally proportional to the difference
between the existing concentration and the equilibrium
concentration of the gas in solution
. ( )c g sdc A
r K C Cdt V
3
KLa
)tLaK(
0s
ts eCC
CC
![Page 4: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/4.jpg)
The overall mass transfer coefficient (KLa) is determined in test or
full-scale facilities.
If pilot-scale facilities are used → Scale up must be considered to
determine KLa
4
![Page 5: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/5.jpg)
5
Determination of KLa in clean water (ASCE, 1992)
Dissolved oxygen (DO) is removed from a known volume of water
by the addition of sodium sulfite
Then the water is reoxygenated to mean the saturation level. During
reoxygenation (reaeration) period, DO concentrations are measured
Time, min DO Concentration, mg/L
….. ….
….. …
Experimental Data:
![Page 6: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/6.jpg)
Using experimental data, Cs-Ct versus t is plotted
Cs-Ct
time
Slope = KLa / 2.303 ═ KLa = (slope) (2.303)
Logarithmic
Scale 6
303.2
K)CClog()CClog(e
CC
CC La0sts
)tLaK(
0s
ts
![Page 7: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/7.jpg)
Determination of KLa in wastewater
Uptake of oxygen by microorganisms must be considered.
Typically, oxygen is maintained at a level of 1 to 3 mg/L and the
microorganisms use the oxygen as rapidly as it is supplied.
Rate of oxygen used by microorgnisms
can be determined in lab by using respirometer
7
If the oxygen level is maintaned at a constant level, dc/dt = 0 and ;
msLa r)CC(Kdt
dc
)CC(
rK)CC(Kr
s
mLasLam
![Page 8: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/8.jpg)
8
The mass transfer coefficient KLu is a function of:
Temperature
Intensity of mixing (type of aeration device & geometry of mixing basin)
Constituents in water
![Page 9: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/9.jpg)
Effect of Temperature on Oxygen Transfer
ϴ = 1.015 – 1.040
1.024 is a typical for both diffused and mechanical aeration devices.
9
)20T()C20(La)T(La KK
![Page 10: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/10.jpg)
Effects of mixing intensity & tank geometry
α varies with;
Type of aeration device
The basin geometry
The degree of mixing
The ww characteristics
10
α = 0.3 – 1.2
For diffused aeration equip. = 0.4 – 0.8
For mechanical equipment = 0.6 – 1.2
Pöpel Equation
)watertap(K
)wastewater(K
La
La
3/2)1000
(16.01MLSS
![Page 11: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/11.jpg)
Effects of wastewater characteristics
β → is used to correct the test system oxygen transfer rate for
differences in oxygen solubility due to constituents in the water
such as salts, particulates, and surface-active substances
β = 0.7 – 0.8
(0.95 is commonly used for ww)
11
)(
)(
watertapCs
wastewaterCs
![Page 12: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/12.jpg)
CALCULATION OF ACTUAL AMOUNT OF OXYGEN
REQUIRED UNDER FIELD CONDITIONS
AOTR = actual oxygen transfer rate under field conditions, kg O2 / hr
SOTR = standard oxygen transfer rate in tap water at 20 C, and zero dissolved oxygen, kg O2 / hr
β = salinity-surface tension correction factor = Cs (ww) /Cs(tapwater)
Cs,T,H = average dissolved oxygen saturation concentration in clean water in aeration tank at temperature T
and altitude H, mg/L
CL = operating oxygen concentration, mg/L
CS,20 = DO saturation concentration in clean water at 20 C and 1 atm, mg/L
T = operating temperature, C
α = oxygen transfer correction factor for waste
F = fouling factor (typically 0.65 – 0.9) is used to account for both internal & external fouling of air
diffusers.
12
)F)()(024.1)(C
CC(SOTRAOTR 20T
20,s
LH,T,S
![Page 13: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/13.jpg)
13
internal
caused by impurities in the compressed air
Diffuser Fouling
external
caused by the formation of biological slimes
and inorganic precipitants
![Page 14: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/14.jpg)
For surface aerators:
CS,T,H = CS,T,H
CS,T,H = oxygen saturation concentration in clean water at temperature T
and altitude H ), mg/L (see Metcalf & Eddy, 2004, Appendix D)
Pd = pressure at the depth of air release, kPa
(Patm,H + Pw,effective depth)
Patm,H = atmospheric pressure at altitude H, kPa (see Metcalf & Eddy, 2004, Appendix D)
OT = % oxygen leaving tank (usually 18 – 20 % )
14
)21
O
P
P(
2
1CC t
H,atm
dH,T,SH,T,S
![Page 15: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/15.jpg)
The term in the brackets when multiplied by one-half represents the
average pressure at mid depth and accounts for the loss of oxygen to
biological uptake.
If biological uptake is not considered,
Pw,mid depth = pressure at mid depth, above point or air release due to
water column. 15
)(,
,,
,,,,Hatm
depthmidwHatm
HTSHTS P
PPCC
)21
O
P
P(
2
1CC t
H,atm
dH,T,SH,T,S
![Page 16: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/16.jpg)
Oxygen Transfer Efficiency (OTE) of Diffusers
16
Specific Oxygen Transfer Efficiency (SOTE) of Diffusers
(% OTE / m water depth )
284 MLSS10.56.2MLSS10.63.89)m/(%SpOTE
depthwatermxSpOTE(%)OTE
![Page 17: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/17.jpg)
Typical clean water transfer efficiencies (SOTE) for various diffused air devices → M&E, 4th
Edition Table 5.27, pg. 437
17
![Page 18: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/18.jpg)
Example: Calculate the required total blower capacity necessary to supply
oxygen requirement of 2892.7 kg/d for the plant having following characteristics.
18
Fine bubble aeration system
DO in aeration basin = 2 g/m3
Site elevation = 500 m (pressure 95.6 KLu))
α = 0.5, β = 0.95, F = 0.9
Liquid depth for aeration basin = 4.9 m
The point of air release for the aerobic diffuser is 0.5 m above the tank bottom
![Page 19: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/19.jpg)
Solubility of Dissolved Oxygen in Water as a Function of Salinity and
Barometric Pressure Ref: Metcalf & Eddy
19
![Page 20: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/20.jpg)
Ref: Metcalf & Eddy
20
![Page 21: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/21.jpg)
Ref: Metcalf & Eddy
21
![Page 22: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/22.jpg)
Table B-1
Molecular weight, specific weight, and density of gases found in
wastewater at standard conditions (0 C and 1 atm)
Ref: Metcalf & Eddy
22
![Page 23: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/23.jpg)
Table B-2
Composition of dry air at 0o C and 1.0 atmosphere
Ref: Metcalf & Eddy
23
![Page 24: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/24.jpg)
Ref: Metcalf & Eddy
24
![Page 25: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/25.jpg)
Ref: Metcalf & Eddy
25
![Page 26: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/26.jpg)
Aeration Systems Used for WW Treatment
Diffused Air Systems
Blower , air mains, header pipes through
which air passes
Diffusers that are submerged in ww
Mechanical Aeration Systems
Aerations w/ vertical axis
→surface aerator
→submerged aerator
Aeration w/ horizontal axis
→surface aerator
→submerged aerator
High Purity Oxygen Systems
Downflow bubble contactor
U tube contacter
26
•Porous diffusers
•Non-porous diffusers
•Other diffusion devices
![Page 27: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/27.jpg)
Domestic disks membranes
Tubes
Plutes
Typical Porous Air Diffusers
27
![Page 28: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/28.jpg)
Typical Porous Air Diffusers (continue)
28
![Page 29: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/29.jpg)
Diffused – Air Aeration Systems
the size of bubbles varies from
coarse to fine
• fine-bubble diffusers
• coarse bubble diffusers
29
air is introduced into liquid being aerated in the form of bubbles which
typically rise through the liquid
common device for ;
transferring oxygen in aerobic biological treatment
systems stripping of volatile organics
COARSE BUBBLE
FINE BUBBLE
Ref: http://www.brightwaterfli.com/diffused_aeration_systems.htm
Ref:http://www.hellotrade.com/diffused-gas-technologies-incorporated/ss-series-plenum-coarse-bubble-diffusers.html
![Page 30: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/30.jpg)
Diffused – Air Aeration Systems (continue)
Porous diffusers (e.g., plate, dome, disc, tubular diffusers)
Nonporous diffusers (e.g., fixed orifice, valved orifice)
Other diffusers (e.g., jet aeration)
30
gas transfer rate size of bubbles
→ smaller bubbles → greater A/ → more efficient than larger sized
bubbles for mass transfer
![Page 31: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/31.jpg)
31
Dome, disc diffusers are mounted on or screwed into air manifolds
Ref: Metcalf & Eddy, 1991, McGraw Hill
DOME DIFFUSER DOME DIFFUSER DISC DIFFUSER
Typical Porous Diffusers
Diffused – Air Aeration Systems (continue)
![Page 32: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/32.jpg)
32
Produce larger bubbles than
porous diffusers
Lower aeration efficiency
Lower cost, less maintanance
Typical Non Porous Diffusers
Ref: Metcalf & Eddy, 1991, McGraw Hill
Valved orifice diffuser
VALVED ORIFICE DIFFUSER
(non porpous diffuser)
Device that contains a check value to
prevent backflow when air is shut off.
Mounts on air distribution piping.
Perforated tube diffuser
Diffused – Air Aeration Systems (continue)
Ref: Metcalf & Eddy, 1991, McGraw Hill
![Page 33: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/33.jpg)
33
Jet aerator
discharges a mixture of pumped liquid and
compressed air through a nozzle.
Jet aerator Aspirating aerators
Typical Other Diffusion Devices
Diffused – Air Aeration Systems (continue)
![Page 34: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/34.jpg)
34
![Page 35: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/35.jpg)
35
![Page 36: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/36.jpg)
36
![Page 37: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/37.jpg)
37
![Page 38: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/38.jpg)
38
![Page 39: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/39.jpg)
DIFFUSER PERFORMANCE The efficiency of oxygen transfer depends on many factors;
Type, size, and shape of diffuser
The air flowrate
The depth of submersion
Tank geometry including the header and diffuser location
ww characteristics
Aeration devices → evaluated in clean water (SOTE, standard oxyen transfer
efficiency)
→ the results are adjusted to process operating conditions 39
![Page 40: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/40.jpg)
Typical Nonporous Air Diffusers (continue)
Non-porous Diffusers; (produce more bubble than porous
diffusers)
• Orifice
• tube
40
![Page 41: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/41.jpg)
Other Diffusion Devices Other Diffusion Devices
• Jet aerator
• Aspirating aerator
• U-tube
41
![Page 42: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/42.jpg)
Other Diffusion Devices (continue)
42
![Page 43: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/43.jpg)
Blowers;
3 types of blower are commonly used for aeration;
Centrifugal
Rotary lobe positive displacement
Inlet guide vane-variable diffuser
43
![Page 44: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/44.jpg)
Centrifugal blowers (capacity > 425 m3/min
discharge pressure ranges 48-62 kN/m2
similar to low-specific-speed centrifugal pumps
the operating point is determined by the intersection of the
head-capacity curve and system curve
44
![Page 45: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/45.jpg)
Rotary lobe positive displacement (capacity < 425 m3/min)
for higher discharge pressure applications > 55 kN/m2
is a machine of constant capacity w/ variable pressure
the units can not be throttled but capacity control can be
obtained by the use of multiple units or a variable speed drive
45
![Page 46: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/46.jpg)
a relatively new blower design
a single stage centrifugal operation that
incorporates activaters to position the inlet
guide vane and variable diffuser to vary
blower flowrate.
well suited to applications with medium to
high fluctuations in inlet temperature,
discharge pressure and flowrate
46
Inlet guide vane-variable diffuser (capacity 85 – 1700 m3/min)
blower capacity 85 – 1700 m3/min at pressures up to 170 kN/m2
turndown rate (Qmin/Qmax) : 40% is possible w/o significant
reduction in operating efficiencies
high initial cost , sophisticated computer control system
![Page 47: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/47.jpg)
In WWTP, blowers must supply a wide range of airflows under varied
environmental conditions. Provisions have to be included in the
blower system design to regulate or turndown the blowers
47
Methods to achieve regulation or turndown;
Flow blow-off or by passing → effective method of controlling
surging of a centrifugal blower
Inlet throttling are applicable only to adjustable
discharge diffuser centrifugal blowers
variable speed driver → more commonly used on positive
displacement blowers
parallel operation or multiple units
![Page 48: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/48.jpg)
MECHANICAL AERATORS
By producing a large air-water interface the transfer of oxygen
from atmosphere is enhanced
Can be VERTICAL SHAFT or HORIZONTAL SHAFT
48Ref: http://www.waterandwastewater.com/www_services/newsletter/april_18_2011.htm Ref: http://en.wikipedia.org/wiki/File:Surface_Aerator.jpg
![Page 49: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/49.jpg)
MECHANICAL AERATOR PERFORMANCE
are rated in terms of kg O2 / kw – hr at standard conditions, 20 C,
DO = 0, test liquid is tap water.
commercial size surface aerators range in efficiency from 1.2 – 2.4
kg O2 / kwhr
49
For design purposes, the standard performance data must be adjusted
to reflect field conditions by using the following equation;
20TLwalt0 024.1)
17.9
)CC(NN
![Page 50: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/50.jpg)
N = kg O2/ kw.hr transferred under field conditions
No = kg O2/kw.hr transferred in water at 20 C, and 0 DO.
β = salinity-surface tension correction factor (usually 1)
Cwalt= oxygen saturation concentration for tap water at given
temperature and altitude (Appendix D) (Figure 5.68)
CL = operating oxygen concentration, mg/L
T = temperature, C
α = oxygen transfer correction factor for waste (Table 5.32, pg.447)
Figure 5.68 (Metcalf & Eddy, 2004
Elevation, 103
Oxygen
Solubility
Correction
Factor (Fa)
50
xFa)levelseaat(Cs)alt(Cs
![Page 51: ENVE 302 Environmental Engineering Unit Processesbilge.alpaslan/ENVE 302... · 2012. 6. 1. · AOTR = actual oxygen transfer rate under field conditions, kg O 2 / hr SOTR = standard](https://reader035.vdocuments.site/reader035/viewer/2022062404/612fb1b51ecc515869439d7f/html5/thumbnails/51.jpg)
51
Oxygen transfer data for various types or mechanical aerators → Table 5.31,
pg. 446 (Metcalf & Eddy, 4th Edition)