Kapuk Raya no. 8 Rt. 11/ Rw. 05 Jakarta Barat 11720Tel. +6221-5452228/ 5449729 | Fax. +6221-6191327www.siantartara.co.id | email : [email protected]
MODEL VERSION COP POWER (KVA) ENGINE GUARANTED NOISE AUTONOMY (H) AT 75% WEIGHT400V 230V BRAND/TYPE LEVEL dB (A) OF LOAD KG
S5000 single phase 4,1 Honda/GX270 71 1,6 76
S5000 three phase 5,4 3,1 Honda/GX270 71 1,6 88
S8000 single phase 6,0 Honda/GX390 72 2,2 96
S8000 three phase 7,0 4,1 Honda/GX390 72 2,1 99
S12000 single phase 10,0 Honda/GX630 70 3,9 162
S12000 three phase 11,8 6,9 Honda/GX630 70 3,9 165
S-SERIESTHE COMPLETE PACKAGEAll the features of a top class generator: a powerful and economical engine, a strong and modern design and a long-run easy filling fuel tank.
MODEL VERSION COP POWER (KVA) ENGINE GUARANTED NOISE AUTONOMY (H) AT 75% WEIGHT400V 230V BRAND/TYPE LEVEL dB (A) OF LOAD KG
P11000 single phase 10,0 Yanmar/3TNV70 70 3,0 325
P11000 three phase 10.0 6,0 Yanmar/3TNV70 70 3,0 325
P12000 single phase 10,0 Honda/GX630 64 4,1 188
P12000 three phase 11,0 4,0 Hatz/2G40 72 2,3 275
P12000 three phase 11,8 4,0 Honda/GX630 64 4,1 185
P-SERIESTHE SILENT POWER (II)
Low noise level, AMF or RSS features and powerful, reliable Dieselengines. These generators are ideal for domestic backup power supply
or professional use in residential areas.
MODEL VERSION 400V POWER (KVA) ENGINE GUARANTED NOISE AUTONOMY (H) AT 75% WEIGHTLTP PRP BRAND/TYPE LEVEL dB (A) OF LOAD KG
GBW10Y MCP 9,3 8,5 Yanmar/3TNV76 64 19,2 460
GBW15Y MCP 14,3 13,0 Yanmar/3TNV88 64 13,5 430
GBW22Y MCP 19,4 17,6 Yanmar/4TNV88 64 10,3 560
GBW10P MCP 9,7 8,7 Perkins/403D11G 66 19,8 460
GBW15P MCP 14,1 12,7 Perkins/403D15G 66 14,1 550
GBW22P MCP 21,8 19,8 Perkins/404D22G 66 9,7 565
GBW-SERIESFRIENDLY GENERATIONThis range has optimized features specially focused to meet the needs of
low investment applications. Generators have reduced dimensions and weight making them easy to transport and store. This range could be also
used as rental equipment.
MODEL VERSION 400V POWER (KVA) ENGINE GUARANTED NOISE AUTONOMY (H) AT 75% WEIGHTLTP PRP BRAND/TYPE LEVEL dB (A) OF LOAD KG
GSW30Y MCP 32,5 30,5 Yanmar/4TNV98 66 8,3 765
GSW45Y MCP 45,9 41,8 Yanmar/4TNV98T 66 5,8 815
GSW30P MCP 32,5 30,5 Perkins/1103A33G 64 7,9 929
GSW45P MCP 48,0 45,7 Perkins/1103A33G1 66 6,5 977
GSW SERIESPROFESSIONAL ENERGY
This range of generators is suitable for any applications; low noise, security, greatly extended running time and versatility make GSW series the perfect choice for the business.
MODEL VERSION 400V POWER (KVA) ENGINE GUARANTED NOISE AUTONOMY (H) AT 75% WEIGHTLTP PRP BRAND/TYPE LEVEL dB (A) OF LOAD KG
GSW815P MCP 695 632 Perkins4006-23 TAG2A 6,1 6200-8460
GSW875P MCP 760 679 Perkins4006-23 TAG3A 5,7 6210-8460
GSW1130P MCP 958 872 Perkins4008TAG2A 4,5 8170-10110
GSW1400P MCP 1166 1055 Perkins4012-46TWG2A 3,6 1029-12150
GSW1510P MCP 1263 1149 Perkins4012-46TWG3A 3,3 1290-13260
GSW1650P MCP 1417 1289 Perkins4012-46TAG2A 3,2 11320-13560
GSW1780P MCP 1579 1436 Perkins4012-46TAG3A 2,5 14140-TBD
GSW2025P MCP 1694 1568 Perkins4016-61TRG1 2,6 14588-TBD
GSW2266P MCP 1885 1674 Perkins4016-61TRG2 2,3 14902-TBD
GSW2520P MCP 2083 1875 Perkins4016-61TRG3 2,1 14910-TBD
GSW HIGH POWER SERIESMORE POWER IN TIMEThese generators are designed to fulfil the increase of energy demand with high quality product for every kind of application, but at the same time to enjoy the economic/delivery benefits of a standart production.
MODEL VERSION 400V POWER (KVA) ENGINE GUARANTED NOISE AUTONOMY (H) AT 75% WEIGHTLTP PRP BRAND/TYPE LEVEL dB (A) OF LOAD KG
GSW870M MCP 733 663 MTU12V2000G65 6,0 6200-8460
GSW1000M MCP 733 633 MTU12V2000G25 5,2 6950-9810
GSW1120M MCP 935 846 MTU16V2000G65 4,8 7150-10020
GSW1260M MCP 1052 952 MTU18V2000G65 3,7 7840-10820
GSW1500M MCP 1285 1165 MTU12V4000G23R 3,5 11590-TBD
GSW1770M MCP 1522 1380 MTU12V2000G23 3,1 12150-TBD
GSW2040M MCP 1693 1535 MTU12V4000G63 2,8 12430-TBD
GSW2270M MCP 1928 1748 MTU16V4000G23 2,4 15620-TBD
GSW2600M MCP 2112 1915 MTU16V4000G63 2,2 15900-TBD
GSW HIGHER POWER SERIESMORE POWER IN TIMEThese generators are designed to fulfil the increase of energy demand with high quality products for every kind of application, but the same time to enjoy the economic/delivery benefits of a standart production.
MODEL VERSION 400V POWER (KVA) ENGINE GUARANTED NOISE AUTONOMY (H) AT 75% WEIGHTLTP PRP BRAND/TYPE LEVEL dB (A) OF LOAD KG
GSW65P MCP 67,0 60,7 Perkins1103A-33TG2 15,0 909
GSW80P MCP 83,0 78,0 Perkins1104A-44TG2 13,6 964
GSW110P MCP 114,7 103,9 Perkins1104C-44TAG2 10,6 1170
GSW150P MCP 143,0 137,0 Perkins106 TAG 8,1 1417
GSW155P MCP 143,0 137,0 Perkins1106C-E66TAG2 8,1 1623
GSW165P MCP 164,0 150,6 Perkins106 TAG2 6,1 1451
GSW170P MCP 164,0 150,8 Perkins1106C-E66TAG3 7,5 1757
GSW210P MCP 203,8 184,0 Perkins1106C-E66TAG4 9,9 2030
GSW-SERIESENERGY FOR PUBLICAND INDUSTRIAL USESThe GSW series is available with a range of accessories providing a versa-tile solution to a variety of applications.This family of generators offers the best performance under the most difficult and variable operating conditions.Ideal for major industrial areas that need an extra power source.
MODEL VERSION 400V POWER (KVA) ENGINE GUARANTED NOISE AUTONOMY (H) AT 75% WEIGHTLTP PRP BRAND/TYPE LEVEL dB (A) OF LOAD KG
GSW310M MCP 309,5 280,2 MTU/6R1600G70F 10,9 2100
GSW330M MCP 330,0 309,4 MTU/6R1600G80F 10,0 2100
GSW405M MCP 407,2 368,2 MTU/81V1600G70F 7,8 2120
GSW440M MCP 437,0 407,2 MTU/81V1600G80F 7,7 2120
GSW515M MCP 508,2 460,1 MTU/10V1600G70F 5,8 2320
GSW570M MCP 562,9 509,9 MTU/10V1600G80F 6,1 2320
GSW665M MCP 658,9 597,6 MTU/12V1600G70F 4,8 2320
GSW730M MCP 727,3 658,9 MTU/12V1600G80F 4,5 2320
GSW-SERIESPOWER IN ISOLATIONA continuous power supply, provide with high power output and extended running time, makes the range of generators the most suitable for powering sites not connected to a mains power supply.This range is also ideal for running lighting system during power failures.