Energieffektive ventilatorer hos Øland

GPEC-3 GPEC-4 GPPM-1GPEB-1-Intergral

Kammerventilatorer

GLEB-6GLEC-1GTHB-1

Enkeltsugende ventilatorer Boks F400

Tagventilatorer KanalventilatorerSTEF VSA-EKO VKA-EKO BOKS-AKU-EKO

7020 1911 · [email protected]

Prisen for energi fortsætter med at stige og kravene om energibesparelser øges for alle områder.Internationale miljøaftaler vil snart ændres fra vejledende til lovkrav.Energi-effektive produkter vil få deres egne klassifikationer som en del af direktivet for energi brugende produkter (Energy-using products Eup). Det er derfor en fornuftig ide at lave smarte energi effektive løsninger i dag.

Valg af korrekt ventilator er økonomisk og energibesparende.

Bygninger forbruger ca. 40% af alt energi inden for EU. Den samlede andel af ventilation udgør ca. en tredjedel af alt energi forbrug i bygninger og ventilatoren står for den klart største

Den samlede effektivitet er den bedste indikator af energieffektiviteten for en ventilator. En nyttig måling er SFP (Specific Fan Power). Dette er ventilatorens samlede elektriske forbrug divideret med ventilatorens luftmængde (SFP=PE/qv=kw/m³/s) SFP målingen er et godt sammenlignings- grundlag for ventilatorer af forskellige producenter, forudsat at det totale elforbrug er udregnet ens. Når man dimensionerer det ”Specifikke Fan Power” bør følgende overvejes: - Ventilators virkningsgrad i driftspunkt - Motor effektivitet også ved delbelastning - Hastighedsregulators virkningsgrad og dennes påvirkning af motor.

energiforbrugende del. Derfor er en korrekt dimensioneret økonomisk ventilator den vigtigste del for en optimal energibesparelse.

Fabrikationen er certificeret i henhold til ISO 9001 og ISO 14001 standarderne

Brug den smarte energibesparende løsning i dag!

SFP=PE/qv=kW/m3/s

Effektivitet er den vigtigeste faktor.Det omtrentlige energiforbrugfor bygninger i EU

Køling30 %

Ventilation30 %

Opvarming30 %

Lys og andretekniskeinstallationer

10 %

A factory-ready tested unit, which fulfils the future ErP requirements already today.

Designers and product developers are set increasingly tough requirements

3 brand has become a mark of

footprint.

ready, integrated product with an awesome performance and functional -ity. Factory precision measurements are provided for every impeller size and the factory guarantees their accuracy. Existing measurement data helps the manufacturer considerably, as all the data required by the authorities already exists and the manufacturer does not need to

Two ways to make a more efficient air conditioning machine

integrated impeller unit, it can be seen also as better SFP.

(still having the same total SFP as with std-motor and std heat recovery system).

The technically advanced Centriflow Quattro fullfils Erp 2015 require -ments with ease.

The lifetime carbon footprint of the top efficient impeller is as small as possible.

Energy saved by Centriflow Quattro can be used at heat recovery wheels to increase the total heat benefit ratio of AHU.

The individually programmed frequency converter forms the central core of reliability and energy efficiency.

Elec

tric

ity s

aved

by Q

uatt

ro

Heatrecovery Hea

t rec

laim

ed

by

hea

trec

over

y

7020 1911 · [email protected] 3

7020 1911 · [email protected]

The schedule of ErP regulations

The first phase (tier 1) comes into force on the 1st January 2013.

The regulation sets out minimum efficiency grades for fans within its scope being placed on the market for the first time. The efficiency grade is based on the electrical input power and therefore encompasses both the fan efficiency and the motor efficiency.

Any fan placed onto the market for the first time (usually by the manufacturer) will have to comply with these efficiency grades. It will be illegal to introduce a fan onto the market after 2012 that does not comply.

A second phase (tier 2) of tighter efficiency grades will come into force on the 1st January 2015.

The second stage with higher efficiency values becomes e�ective on January 01, 2015, and this will consider the entire fan, not just the fan motor.

Fan regulations

The regulation sets out minimum efficiency grades for fans within this scope being placed on the market for the first time. The efficiency grade is based on the electrical power from mains and therefore encom -passes both the fan efficiency and motor efficiency. Any fan placed on the market for the first time will have to comply with these efficiency grades.

For classification of fans efficiency, grade N has been generated (in international ISO standard the symbol is FMEG).

Depending on the model of the fan, the efficiency grade N in accordance with ErP Directive must be complied.

The efficiency grade can be measured for complete fan system or calculated by using algorithms defined within regulations.

How the efficiency is calculated?

The EU has specified the corresponding formulas with which the respective mini -

mum efficiency for axial fans, forward and backward curved centrifugal fans, tangential blowers and diagonal fans can be calculated

FW fans meets ErP regulation already now

How does the ErP Directive a�ect fans?

Several models used to date do not meet the require -ments and have therefore been revised or taken o� the market. It has been illegal to introduce a fan onto the market after 2012 that does not comply.

ηe = Pu(s) / Pe

Efficiency grades to be achieved

Efficiency grade “N” to ErP-Diective

Year static static total static total

2013 58 58 61 37 42

2015 62 61 64 44 49

Centrifugal fans with forward curved blades

without housing

with housing

with housing

Centrifugal fans with backward curved blades

European Energy Related Products Directive (ErP)

Following the Kyoto protocol the EU has set a target to reduce energy consumption by 20%, and increase the share of renewable energies by 20% by 2020. With ErP Directive the EU has defined the way to do this.

Because of ErP directive for fans, fan manufacturers will be required to design their products for the European market to comply with defined efficiency standards to make an important contribution to reducing energy consumption.

For this reason applicable regulations and standards have been developed for di�erent product categories within EU. For fans with input power between 125W and 500 kW the Commission’s Regulation 327/2011/EC is applied.

The user can recognize fans that satisfy the requirements of the directive by the CE sign.

7020 1911 · [email protected] 5

Centrifl ow breaks the world record once again!

World record fan, Centrifl ow Plus PM maximizes the advantages of permanent magnet motor technology.

The new Centrifl ow Plus PM provides highest effi ciency in a small and compact design.

The new PM motor range with optimal and effi cient airfl ow through our impeller.

Centrifl ow Plus PM: highest effi ciency through a wide range of power and airfl ow.

Centrifl ow Plus PM provides highest total effi ciency including fan, motor and drive.

When launched the Centrifl ow Plus plug fan broke the world record in effi ciency, its successor the Centrifl ow Plus EC, broke the record again. Now our new Centrifl ow Plus PM puts the previous records into history and lifts the record once again to a new higher level!

Taking advantage of new permanent magnet motor technology with improved motor effi ciency, also having optimized the airfl ow through our impeller, we have improved the total fan motor effi ciency by up to 6%.

Improved aerodynamics with a higher overall effi ciency and thus a lower power consumption, all in a smaller more compact size.

Motors are available in the power range from 0.75 up to 22 kW o�ering airfl ows up to 10 m3/s and pressures up to 1500 Pa.

The overall footprint of the Centrifl ow Plus PM fan is smaller due to the compact PM motor dimensions.0 500 1000 1500 2000 2500 35003000

70,065,060,055,050,045,040,035,030,0

Speed

PMECIE2/EFF1

Total efficiency example

PM

Fan-motor range0.5 1 1.5 2 2.5 3 3.5 4 5 6 7 8 9 10 11 12 13

025028031035040045050 7.5

056063071

3

3.6

4

4.8

7.5

11

11

080

1.5

2.2

1.8

1.8

3.6

5.5

3.6

4

5.5

5.5

11

090100

0.8

1.1

1.1

1.8

1.8

2.2

2.2

2.2

3

5.5

11

11

0.8

Size Motor powers / kW m3/s

Current maximum available motor size 11 kW

7020 1911 · [email protected]

7020 1911 · [email protected] 7

ØLAND Kammerventilator

Ventilationstørrelse og kapicitet

Programmet CENTRIFLOW Plus kammerventilatorer består af 14 direkte trukne størrelser,Der dækker en luftmængde på op til 16 m3/s og et maksimaltryk på op til 2300 Pa.

022025

028031

035040

045050

056063

071080

090100

16 m 3/s0,1 0,2 0,5 1 2 4 8

Centriflow Plus EC produkt linje består af seks ventilator størrelser, der dækker en luftmængde op til 7920m/h med et maksimaltryk op til 1500 Pa.

Sammenligning af Centriflow Plus EC og Centriflow Plus med en traditionel AC motor og frekvensomformer. Ventilatorstørrelse 250 og 0,55 kW´s motor.

Kapacitet Centriflow Plus EC

022

025

028

031

035

040

0, 1 0 ,2 0, 5 1 2 m3/s

0,35

0,40

0,45

0,50

0,55

0,60

0, 1 0 ,5 1, 0 1 ,5 2, 00,30

CF plus med standard AC motor og frekvensomformer.

CF Plus EC

Totalvirkningsgrad

Ove

rall

effi

cien

cy

7020 1911 · [email protected]

Kammerventilator monteres i eksisterende ventilatorrum:

• Mellemvæg behøves (1)

• Udløbsåbning og kanal gøres større (2)

• Kammerventilatoren fastgøres på eventuelt eksisterende tværgående bundramme (3)

OBS. Sikkerhed!

• Ventilatorrummet sættes under overtryk - servicelågens lukn-ing og tæthed kontrolleres.

• Kammerventilatorens hjul er ubeskyttet - monteres evt. de-monterbare beskyttelsesnet bag servicelågen.

21

3

2

022 025 028 031 035 040 045 050 056 063 071 080 090 100H 399 411 488 520 606 646 768 813 927 990 1062 1243 1448 1538C 90 100 112 126 142 160 180 200 224 252 284 320 360 400R 113 125 140 158 178 200 225 250 280 315 355 400 450 500

• Check altid mål og observer afstand til aggregatdelen (R) og minimum anbefalet fri højde (H)

• For erstatnings ventilatoren. Målene R, H og C fåes i tabellen. Vi anbefaler at checke anlægget generelt og evt. lave en skitse.

Mål H: min. anbefales fri højde for ventilator =højde fra bundramme till overkant hjul + mål C + vibrationsdæmper

H

L min115

GPEB-1GPEC-3GPPM

220 250 280 315 355 400 450 500 560 630 710 800 900 1000

H 399 411 488 520 606 646 768 813 927 990 1062 1243 1448 1538

C 90 100 112 126 142 160 180 200 224 252 284 320 360 400

R 113 125 140 158 178 200 225 250 280 315 355 400 450 500

L 630 690 780 835 940 990 1050 1230 1310 1390 1490 1650 1800 1960

L 450 470 500 590 630 680 850 850

L 650 660 700 800 850 910 1030 1110 1190 1380 1460 1700 1750

7020 1911 · [email protected] 9

ROOFMASTER Plus ECTak�äkt STEC med hög verkningsgrad

7020 1911 · [email protected]

högverkningsgradsvariant, Roofmaster Plus EC vars total -verkningsgrad är på en helt ny nivå! Jämfört med den tradi -

förbättras med över 30 %.

Totalverkningsgraden baserar sig på det välkända CENTRI--

netmotor. Moderna permanentmagnetmotorer har en hög verkningsgrad och den bibehålls även då motorn körs med lägre varvtal. De övriga välkända egenskaper hos Roofmaster STEF har vi behållit. Ljudnivån är låg och Roofmaster Plus EC är lika montage -

Det genila fläkthjulet och energie�ektiv EC-motor en oslagbar kombination

7020 1911 · [email protected] 11

Mångsidiga regleringsalternativ

Behovet av ventilation varierar kraftigt över dygnet och årstiden. Med behovstyrd ventilation sparar man i driftskostnader. Roofmaster Plus EC har en inbyggd varvtalsregulator och varvtalet kan styras steglöst med en 0 till 10V styrsignal eller manuellt med en po -tentiometer. Det är också möjligt att köra med en eller två fasta varvtal. En tryckreglulator kan kopplas till Roofmaster Plus EC för att få konstanttryckstyrning. Tryckregulatorn kan förses med utetemperaturgivare

exakt det varvtal som krävs för tillfället. Det ger en låg ljudnivå, sparar el och uppvärmningskostnader.

Roofmaster Plus EC takfläkt STEC finns i fyra stor -lekar och täcker luftflöden upp till 1.7 m 3 /s och tryckökning upp till 750 Pa.