endress+hauser flow product portfolio

32
05/06/2014 Products Solutions Services Endress+Hauser Product Portfolio Linh Tran Slide 1

Upload: protung

Post on 28-Dec-2015

126 views

Category:

Documents


7 download

TRANSCRIPT

Page 1: Endress+Hauser Flow Product Portfolio

05/06/2014

Products Solutions Services

Endress+Hauser Product Portfolio

Linh Tran Slide 1

Page 2: Endress+Hauser Flow Product Portfolio

05/06/2014

Flow Measurement - Overview

The Proline Concept

Calibration

Promag

Promass

Prosonic Flow

Prowirl

T-mass

DP-Flow

Linh Tran

5/17/2014

Slide 2

Page 3: Endress+Hauser Flow Product Portfolio

05/06/2014

PORTFOLIO FOR LIQUIDS

Promass • All Liquids • SS, alloy, titanium,

zirc. • 0,1% • DN1…250 • -200…+350°C • 400bar Advantage • All liquids • No inlet run • High precision • Multivariable Drawbacks • Pressure drop • High price

Prosonic • All liquids • SS • 0.5%(0.3%) • DN25…300 • -40…+150°C • 40bar Advantage • All liquids • no pressure drop • 2 wires Drawbacks • 5 x DN

Prowirl • All liquids • SS, alloy 0.7% • DN15…300 • -200…+400°C • 160bar (250bar) • 15 x DN Advantage • All liquids • 2 wires Drawbacks • 15 x DN • Pressure drop

Promag • Conductive liquid • PTFE, PFA • 0.2..0.5% • DN15…300 (600) • -20…+150°C • 40 bar • 5 x DN / 3 X DN Advantage • No pressure drop Drawbacks • Inlet run • only conductive liquid

PRICE

Performance

The Proline Concept

Calibration

Promag

Promass

Prosonic Flow

Prowirl

T-mass

DP-Flow

Linh Tran

5/17/2014

Slide 3

Page 4: Endress+Hauser Flow Product Portfolio

05/06/2014

PORTFOLIO FOR GAS

Promass • All gas • SS, Alloy, Titan,

Zirkon. • 0,1% • DN1…250 • -200…+350°C • 400bar Advantage • Direct mass • No inlet run • High precision • Multivariable Drawbacks • Pressure drop • High price • for Gas up to 2 bar

T-mass • 20 gaz in standard • 1,5% • DN15…1500 • -40…+130°C • 40bar • 5x DN U/D (DN15..100) Advantage • Direct mass

measurement • Pressure drop (<2mbar) • Leakage detection (min. Flow) • Only 5 x DN U/D (with flow conditioner) • Low cost solution Drawbacks • limited to < 25m/s

Deltatop/set • All gas • 1…3% • DN15…12000 • -200…+1000°C • 40 bar • 15 x DN Advantage • All Gas • Several material Drawbacks • > 15 x DN • Pressure drop

Price

Performance

Prowirl 73+Hart • All gas • SS, Alloy • 1 % • DN15…300 • -200…+400°C • 160bar • 15 x DN Advantage • All Gas • 2 wires • Cheap Solution Drawbacks • 15 x DN U/D • Pressure drop • Low flow configurable

The Proline Concept

Calibration

Promag

Promass

Prosonic Flow

Prowirl

T-mass

DP-Flow

Linh Tran

5/17/2014

Slide 4

Page 5: Endress+Hauser Flow Product Portfolio

05/06/2014

PORTFOLIO FOR STEAM

Deltatop/set • All type of steam • 1…3% • DN15…12000 • -200…+1000°C • 40 bar • 15 x DN U/D Advantage • Versatile Sol • material Drawbacks • > 15 x DN • Pressure drop

Price

Performance

Prowirl 73+HART • Saturated and

superheated • SS, Alloy • 1 %, DN15…300 • -200…+400°C • 160bar (250bar) • 15 x DN Advantage • Sat or superheated • 2 wires • cheap Drawbacks • 15 x DN • pressure drop • low flow adjustable

Prowirl 72+RMC • Sat or superheated • SS, Alloy • 1 % • DN15…300 • -200…+400°C • 160bar (250bar) • 15 x DN Advantage • Sat or superheated • 2 wires Drawbacks • 15 x DN • Pressure drop • Low flow adjustable

Prowirl 73 • Saturated steam • SS, Alloy • 1 %, DN15…300 • -200…+400°C • 160bar (250bar) • 15 x DN Advantage • 2 wires • Cheap Drawbacks • 15 x DN U/D • pressure drop • Low flow

adjustable.

The Proline Concept

Calibration

Promag

Promass

Prosonic Flow

Prowirl

T-mass

DP-Flow

Linh Tran

5/17/2014

Slide 5

Page 6: Endress+Hauser Flow Product Portfolio

05/06/2014

Products Solutions Services

Proline Promass

Linh Tran Slide 6

Page 7: Endress+Hauser Flow Product Portfolio

05/06/2014

Why Measure Mass?

• Temperature / Pressure

• Volume 1 ≠ Volume 2

• Mass 1 = Mass 2

Masse 1

Volumen 1 Masse 2

Volumen 2

Principle

Segmentation

Transmitters

Sensors

Advantages

Installation

Accessories

Applications

Linh Tran

5/17/2014

Slide 7

Page 8: Endress+Hauser Flow Product Portfolio

05/06/2014

Overview of direct measuring variables

• Dϕ=Phase shift • m=Mass flow

• fR=Resonance

frequency • r=Density

• W= Resistance

(PT1000) • T=Temperature

∆ϕ ~ m

fR ~ ρ

Ω ~ T

Linh Tran

Principle

Segmentation

Transmitters

Sensors

Advantages

Installation

Accessories

Applications

5/17/2014

Slide 8

Page 9: Endress+Hauser Flow Product Portfolio

05/06/2014

Promass Sensors

Promass A Promass E

Promass F

Promass M Promass I Promass H

Promass F HT

Promass P

Promass S

Linh Tran

Principle

Segmentation

Transmitters

Sensors

Advantages

Installation

Accessories

Applications

5/17/2014

Slide 9

Page 10: Endress+Hauser Flow Product Portfolio

05/06/2014

5/17/2014

Linh Tran Slide 10

Page 11: Endress+Hauser Flow Product Portfolio

05/06/2014

5/17/2014

Linh Tran Slide 11

Page 12: Endress+Hauser Flow Product Portfolio

05/06/2014

5/17/2014

Linh Tran Slide 12

Page 13: Endress+Hauser Flow Product Portfolio

05/06/2014

Products Solutions Services

Promag Magmeters

Linh Tran Slide 13

Page 14: Endress+Hauser Flow Product Portfolio

05/06/2014

Measuring Principle Electromagnetic Flowmeter

Linh Tran

Uflow = induced voltage

v = flow velocity

Q = volume flow

Q = v * A

Uflow ~ v

History

Principle

Segmentation

Transmitters

Sensors

Selection

Installation

Accessories

Applications

5/17/2014

Slide 14

Page 15: Endress+Hauser Flow Product Portfolio

05/06/2014

5/17/2014

Linh Tran Slide 15

Page 16: Endress+Hauser Flow Product Portfolio

05/06/2014

Products Solutions Services

DP- flow

Linh Tran Slide 16

Page 17: Endress+Hauser Flow Product Portfolio

05/06/2014

5/17/2014

Linh Tran

Principle & range

Orifice plates

Pitot tubes

Nozzles

Venturi tubes

Accessories & Installation

Deltabar Evolution

Applications

Slide 17

Page 18: Endress+Hauser Flow Product Portfolio

05/06/2014

5/17/2014

Linh Tran Slide 18

Page 19: Endress+Hauser Flow Product Portfolio

05/06/2014

5/17/2014

Linh Tran

Principle & range

Orifice plates

Pitot tubes

Nozzles

Venturi tubes

Accessories & Installation

Deltabar Evolution

Applications

Slide 19

Page 20: Endress+Hauser Flow Product Portfolio

05/06/2014

root venturi D dp-flow

V venturi

6 generation

primary type generation

1 venturi tube

version mounting

S solutions

5/17/2014

Linh Tran

Principle & range

Orifice plates

Pitot tubes

Nozzles

Venturi tubes

Accessories & Installation

Deltabar Evolution

Applications

Slide 20

Page 21: Endress+Hauser Flow Product Portfolio

05/06/2014

Products Solutions Services

Prowirl – Vortex Flowmeter

Linh Tran Slide 21

Page 22: Endress+Hauser Flow Product Portfolio

05/06/2014

All you need for vortex measurement

f = Vortex frequency

V = Volume flow

f ~ V

Linh Tran

Bluff Body DSC Sensor

Transmitter

5/17/2014

Slide 22

Page 23: Endress+Hauser Flow Product Portfolio

05/06/2014

Prowirl 72/73 - At a Glance

• 4...20 mA / HART® pulse output PROFIBUS PA / FF

• Ex i / Ex d, CE, NAMUR

• -200...400°C

• up to PN 250 / ANSI class 1500

• Wafer version DN 15...150

• Flanges DN 15...300

• Remote version up to 30m

• Wetted parts made from NACE MR 0175 listed materials

• Dual sense available for redundant measuring

• Accuracy 0.75% for liquids 1.00% for gases

Linh Tran

Principle

Segmentation

Transmitters

Sensors

Installation

Applications

Digital Com

Plant Safety

5/17/2014

Slide 23

Page 24: Endress+Hauser Flow Product Portfolio

05/06/2014

5/17/2014

Linh Tran Slide 24

Page 25: Endress+Hauser Flow Product Portfolio

05/06/2014

Products Solutions Services

Prosonic Flow

Linh Tran Slide 25

Page 26: Endress+Hauser Flow Product Portfolio

05/06/2014

The Principle of PROline Prosonic Flow

∆t ~ Q

∆t = time differential Q = volume flow

The time of the ultrasonic signal flow against the flow is slower than the signal with the flow. This results in a signal run time difference, which is proportional to the flow rate.

The Transit Time Principle

Linh Tran

Principle

Clamp-on Transmitters

Clamp-on Sensors

Clamp-on Installation

Inline Meters

Inline Meters Installation

Applications

5/17/2014

Slide 26

Page 27: Endress+Hauser Flow Product Portfolio

05/06/2014

Basic sensor types

Clamp-on + Easy Installation

+ Contact free

- Spacing crucial

Wetted and Inline + Independent of sonic

conductivity of pipe material

+ not affected by changing temperatures

- In contact with liquid = corrosion might be an issue

Linh Tran

Principle

Clamp-on Transmitters

Clamp-on Sensors

Clamp-on Installation

Inline Meters

Inline Meters Installation

Applications

5/17/2014

Slide 27

Page 28: Endress+Hauser Flow Product Portfolio

05/06/2014

PROline Prosonic Flow W • Size range: DN50...4000 • Non-hazardous area • Protection type IP 67 (IP68

optional) • Temperature range -

20...+130°C (Insertion up to +80°C)

All you need for water

applications

Clamp-on sensors

Insertion Sensor for welding in

Linh Tran

The Water Sensors

Principle

Clamp-on Transmitters

Clamp-on Sensors

Clamp-on Installation

Inline Meters

Inline Meters Installation

Applications

5/17/2014

Slide 28

Page 29: Endress+Hauser Flow Product Portfolio

05/06/2014

Prosonic Flow 92F – Ideal for non-conductive liquids

• World-First Loop powered transmitter (2-wire) with HART, PROFIBUS PA or FOUNDATION Fieldbus.

• Size range from DN25/1” to DN300/12” • Pressure range PN16...PN40/Class

150…300. • Temperature range -40….200°C/ -

40….300°F. • The material of all wetted parts is Stainless

Steel 1.4404/316L/316. Body A351-CF3M • Accuracy 0.5% optional 0.3% for 4 beam

systems • Requirement to straight run before the

meter < 5 x DN after bends in one or two planes.

• Hazardous area protection for gas and dust available through intrinsically safety (Ex i) or explosion proof (Ex d).

Linh Tran

Principle

Clamp-on Transmitters

Clamp-on Sensors

Clamp-on Installation

Inline Meters

Inline Meters Installation

Applications

Digital Com

Plan Safety

5/17/2014

Slide 29

Page 30: Endress+Hauser Flow Product Portfolio

05/06/2014

Products Solutions Services

T-mass

Linh Tran Slide 30

Page 31: Endress+Hauser Flow Product Portfolio

05/06/2014

Mass flow measurement based on thermal dispersion

• A heated temperature sensor is kept at a constant differential temperature from the gas reference sensor.

• The cooling effect generated by mass flow causes an increase in sensor power to maintain the temperature differential.

• The power supplied to the heated sensor is proportional to the mass flow.

Mass flow is measured directly • Mass Flow = Density x

Velocity

The measuring principle

Slide 31

Principle

Transmitters

Sensors

Selection

Calibration

Installation

Accessories

Applications

5/17/2014

Linh Tran Slide 31

Page 32: Endress+Hauser Flow Product Portfolio

05/06/2014

Products Solutions Services

Thank you for your attention

Linh Tran Slide 32