en0158.a with light bulbs

16
Missed 3 5 8 10 12 13 14 20 26 41 80% UTILITIES I EXAMINATION Module/SubCourse: EN0158 Edition: A Situation: For questions 1 and 2 use the diagram below: Figure 1. 1. What is the total resistance of this circuit? (Refer to Figure 1 ) 24 Ohms 48 Ohms 12 Ohms 20 Ohms 2. What is the current flowing though the circuit? (Refer to Figure 1 )

Upload: lightprevails

Post on 10-Apr-2015

1.006 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EN0158.a With Light Bulbs

Missed 3 5 8 10 12 13 14 20 26 41 80%

UTILITIES I EXAMINATIONModule/SubCourse: EN0158 Edition: A

Situation: For questions 1 and 2 use the diagram below:

Figure 1.1. What is the total resistance of this circuit? (Refer to Figure 1)

24 Ohms

48 Ohms

12 Ohms

20 Ohms

2. What is the current flowing though the circuit? (Refer to Figure 1)

1.0 Amps

0 Amps

2.0 Amps

Page 2: EN0158.a With Light Bulbs

0.5 Amps

Situation: You are an engineer utilities officer on the staff of the communications zone engineer. You have been assigned the job of preparing the specifications for the water distribution system for the installations shown in the figure below. The following information applies to these installations:

1. The hospital is to be a 1000-bed unit with flush toilets.

2. The staging area will accommodate 8,000 men and will have flush toilets and bathing facilities. The water pressure at the staging area must be a minimum of 25 PSI.

3. Facilities at the wharf will be capable of supplying ships with a total of 75,000 gallons of water every 10 hours.

4. The jungle training area is to accommodate one division of 18,000 men and 2,500 vehicles. Water will be provided for cooking and drinking purposes and for vehicle operations only.

5. A satisfactory water source has been developed 2.5 miles inland. The water will be treated at this source. The minimum pressure required at all delivery points except the staging area will be 12 PSI. The main line from the source to the cross will be 8-inch pipe.

6. Elevations above sea level for the various installations are as indicated in the figure below.This situation pertains to questions 3 through 7.

Figure 2.3. You will have to provide water to the staging area at the rate of (Refer to Figure

2)

284 GPM

834 GPM NO

174 GPM

139 GPM

4. How much water must you supply to the jungle-training center? (Refer to Figure 2)

30 GPM

Page 3: EN0158.a With Light Bulbs

77 GPM

63 GPM

45 GPM

5. You will be required to supply water to the wharf site at a rate of ? (Refer to Figure 2)

125 GPM

750 GPM NO

363 GPM

233 GPM

6. Assume that the available head of water at the cross is 36.2 feet and that the staging area will require 150 GPM. What size pipe should you use for branch #1? (Refer to Figure 2)

6 inch

8 inch

2 inch

4 inch

7. Assume that the available head of water at the cross is 28.4 feet, and that the hospital area will require 85 GPM. What size pipe should you sue for branch #3? (Refer to Figure 2)

1 inch

2 inch

1 ¼ inch

4 inch

8. The three types of pressure include all except:

Atmospheric

Gage

Absolute NO

Cylinder YES!!!!

Page 4: EN0158.a With Light Bulbs

9. R-22 refrigerant is stored in what color cylinder?

Light green with orange band

Orange with yellow band

Orange

Light Green

10. What is the area in square feet that should be provided for a sludge drying bed without drains for a sewage contributing population of 2,500?

10,000 sqft <-PROBABLY?

7,500 sqft

15,000 sqft

11,500 sqft NO

11. _____________ products in sewage make treatment difficult, and ___________ vapors create an explosion hazard in manholes and pipes.

Petroleum

Biological

Caustic

Organic

12. What is the BOD required for 5,000 people in a theater of operation installation?

270 lbs/day

200 lbs/day

1,000 lbs/day

1350 lbs/day NO

13. How many BTUs must be removed from 50lbs of water at 75 degrees Fahrenheit to form solid ice at 32 degrees Fahrenheit?

7200 BTU

9350 BTU

2150 BTU NO

Page 5: EN0158.a With Light Bulbs

8750 BTU

14. Which utilities team is divided into two shifts to provide continuous operations?

GJ

HE

HJ

GE NO

15. Waterborne sewage is _______ percent or more water.

90.4

77.9

58.6

99.8

16. The ___________ or running trap may be used for multiple installations such as sinks or urinals.

Drum Trap

P-Trap

U-Trap

S-Trap

17. __________ is the term used to indicate negative gage pressure.

Head Loss

Suction Head

Suction Lift

Static Head

18. What wire size is required for a 240V single phase load 400ft away from the power source which draws 90A at full load?

2/0 AWG

2 AWG

4/0 AWG

Page 6: EN0158.a With Light Bulbs

6 AWG

19. Which of the below is not considered a basic type of water supply and distribution systems?

Collection

Direct Pumping

Gravity

Combination

20. Early rehabilitation of facilities for immediate military need are most efficiently accomplished by_____________.

Military contractors

Military engineers

Local civilians

All of the above NO

21. ___________ is essentially a controlled rotting or putrification which changes settled solids from a complex organic material to a stable and inoffensive earthlike material.

Settling

Cestpooling

Sludge drying

Digestion

22. A waste pipe carries the discharge from any fixture, except __________, to the soil or waste stacks or directly to the house drain.

Water closets

Lavatories

Showers

Sinks

23. Which of the following is not a common temperature scale?

Fahrenheit

Page 7: EN0158.a With Light Bulbs

Absolute

Celsius

Centigrade

24. A transformer operational fault is indicated by which of the following:

Abnormal heat

Smoke

Abnormal noise

All of the above

Figure 25-1.

Page 8: EN0158.a With Light Bulbs

25. Refer to the diagram above. What is the voltage measured across light bulb #2?

4.8 Volts

6 Volts

10 Volts

12 Volts

26. An 8-inch horizontal drainage pipe with a ? inch fall per foot can support what number of fixture units?

2240

1600 NO

940

1920

27. A ________ is frequently inserted in a main line at points where branches may be required in the future expansion of the area.

Tee

Cross

Y-Branch

Tee, reducing

28. A plumbing system, in its simplest form, consists of one _________ pipe leading to a fixture and one _________ pipe taking the wastewater away from the fixture.

Supply, drain

Supply, branch

Main, branch

Main, drain

29. Secondary treatment of effluent is not accomplished by which of the following methods?

Page 9: EN0158.a With Light Bulbs

Digestion

Irrigation

Use of Oxygen Ponds

Sand Filtering

30. Transmission and distribution lines normally receive ____________ damage in comparison with power stations.

Major

Considerable

Catastrophic

Little

31. That body, gas, or liquid which reduces heat is a _____________.

Condenser

Evaporator

Refrigerant

Insulator

32. Cementing of joints is common practice in ___________ drainage and waste systems.

Surface

Exposed

Underground

Storm

33. Three phase motors will ____________ when two of the three phase inputs are reversed.

Overheat

Rotate in the same direction

Rotate in the opposite direction

Explode

Page 10: EN0158.a With Light Bulbs

34. Some of the more important basic principals for wartime rehabilitation include all of the following except:

Cannibalization

Expedient Repair

Damage Inventory

Substitution

35. What is the approximate capacity of galvanized iron pipe 1-inch in diameter over a 100ft length with a 30 PSI pressure source?

35 GPM

16 GPM

34 GPM

30 GPM

36. Which team provides for maintenance of utilities at installations with personnel numbering 8000 individuals?

HF

HG

GI

GG

37. Which formula properly depicts Ohm?s Law?

E = IR

I = E/R

R = E/I

All of the above

38. _____________ are relatively unimportant as compared to other utilities, and may not be damaged.

Sewer Mains

Water Storage Tanks

Oil Platforms

Page 11: EN0158.a With Light Bulbs

Incinerators

39. Hot water piping is laid out like cold water piping except that _________ are undesirable and paralleling cold waterlines should be avoided if possible.

Dead ends

Fixtures

Returns

Loops

40. ____________ is the most important item of sewer maintenance.

Manhole cover replacement

Repairing breaks

Sealing leaks

Clearing stoppages

41. The mission of engineer cellular teams include:

To provide command and administrative personnel for some brigade engineer units

To provide engineer technical, combat, service, and combat support where units of less than company size are required

To decrease the capability of fixed strength units where increments of more than company size are required NO

All of the above NO

42. __________ heat is heat added to a substance causing a rise in temperature but no change in state.

Fusion

Latent

Vaporization

Sensible

43. Damage to _____________ from sabotage or bombing is relatively unimportant.

Pumping Stations

Page 12: EN0158.a With Light Bulbs

Sewers

Cesspools/Septic Tanks

Treatment Units

44. Which of the following current sources is used to power heavy motors and equipment?

Direct Current

Three Phase Current

Single Phase Current

Alternating Current

45. Engineer installation support in the combat zone is provided for the COSCOM by teams from what TOE series?

29-600

5-500

29-500

5-520

46. The highest priority of power allocation is:

Civilian requirements

Industries beneficial to the military effort

Essential military needs, such as hospitals, ports, and shops

Essential public needs, such as water pumping, hospitals, sewage pumping stations

47. Which of the following is NOT a disinfecting agent for water treatment?

Chlorine

Nitrogen

Iodine

Oxygen

48. In designing a swage disposal system you estimate that your will require discharge of 3,000 GPM at a minimum allowable velocity of 4 ft/sec with a

Page 13: EN0158.a With Light Bulbs

ground slope of 0.45%. What pipe size will be required?

10 inch

15 inch

12 inch

18 inch

49. Utility engineer service teams can be one of the following classes except:

Area Surveying

Fire Fighting

Engineer Combat Support

Dredging

50. The ______________ is where the pressure of the refrigerant liquid is reduced so that it can begin its process of absorbing heat.

Condenser

Expansion Valve

Compressor

Evaporator