ems 12-lead transmission solution
TRANSCRIPT
![Page 1: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/1.jpg)
EMS 12-Lead Transmission Solution
• Rosetta Data Translators
• CAREpoint EMS Workstation
![Page 2: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/2.jpg)
2
Who Is GD? Since 1979
General Devices, a leader in advanced Telemedicine and Communications products for Emergency Medical Services, Emergency Departments and Public Safety, providing solutions for voice, telemetry, patient care information and interoperability via radio, cellular, and landline.
GD is a FDA registered manufacturer.
![Page 3: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/3.jpg)
3
What is Rosetta?
The Rosetta™ Family - The Key to Reliable Communications
The "Rosetta™" family of communications products developed by General Devices help to solve the dilemma of EMS being locked into imperfect communications mediums, be it cellular, UHF/VHF/800 Radio or landline telephone. With Rosetta™ you can utilize the best communications means available for each situation. When the need is critical, count on ROSETTA™ to get the information through!
Definition:
rosetta\ro-,zet-e-\n:
1) A stone that deciphered ancient Egyptian hieroglyphs. 2) A unique device that translates medical information from one communications medium to another (as in translating from digital cellular to UHF radio or analog cellular).
![Page 4: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/4.jpg)
4
Rosetta System Components
Rosetta-Lt Rosetta-Rx CAREpoint Ambulance Hospital (print only) Hospital (full solution)
![Page 5: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/5.jpg)
5
Rosetta-Lt Field (EMS) Side
Creates a “portable” 12-lead
• Transmit from where you want
No need for monthly cellular/data service
• Use your existing radio system
Meets requirements for single lead
• Sends standard ECG strips
Cable connection to most radios
• Keys the radio for you
• Frees up your hands
Receives digital 12 lead files from compatible monitors and “translates” to a format for transmission by radio or certain cell phones…
![Page 6: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/6.jpg)
6
Rosetta-Lt Monitor Compatibility
Compatible with:
MRx
LP12
M & E-Series
Data Types: Single Lead
12-Lead Reports
Vitals (MRx only)
![Page 7: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/7.jpg)
7
Rosetta-Lt CommunicationsCompatibility
Transmit Single & 12 Lead ECG Using: 2-Way Radio
• VHF Cable Connection (recommended)
• UHF or Acoustic Couple
• 800 (analog) Transmits in just over 1 minute!
• Automatic PTT
Cellular • Analog
• Nextel, Cingular (GSM)*
- * Waveform Only
Landline
Rosetta-Lt can transmit virtually over any analog voice channel
![Page 8: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/8.jpg)
8
Rosetta-Lt Communications What Does NOT Work?
Trunked radio systems with digital only voice
Some newer trunk systems are set up for digital only (even though they are likely capable of both analog & digital voice). Rosetta can not transmit on these systems. It does however work on trunk radio with analog voice channels/talk groups.
Digital Cellular Limitations
Rosetta works well over analog cellular but that coverage is on the way out. Rosetta does transmit the waveform portion of the report well over iDEN (Nextel) & GSM cellular (Cingular, etc) Reception of the text info & interpretations is not guaranteed!
Rosetta does NOT work on CDMA cellular systems (Verizon).
Use of the Rosetta-Cell headset jack cable is recommended.
Contact General Devices for verify your systems compatibility.
Rosetta-Lt is very versatile, but there are limitations:
![Page 9: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/9.jpg)
9
Rosetta-Rx Hospital Side (basic print-out only solution)
Data: Single Lead
12-Lead Reports
Communications (Input): 2-Way Radio (receive pair)
Phone line (GSM Cell, Landline)
Printing (Output): HP LaserJet (or compatible)
printer with “parallel port”
Fully Automatic Operation
![Page 10: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/10.jpg)
10
CAREpoint Hospital SideFull Solution!
ECG Display
Printing
• Local printer
• Network printers -Cath. lab, etc.
Forwarding
• Fax
• PDA
Documentation (storage)
• QA Review from office
• D-Scribe Digital Recorder
- Voice and data
![Page 11: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/11.jpg)
11
CAREpoint EMS Workstation
Communications• Voice & Data• Radio Landline & Cellular
Information• InfoManager –Protocols, etc• Single & 12 Lead ECG
Documentation• D-Scribe Digital Recorder• Networked – Remote Access
Telemedicine Ready• e-Bridge platform • Voice * Video * Data * e-PCR * 12L
300+ Currently Installed
![Page 12: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/12.jpg)
12
CAREpoint In Action….
![Page 13: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/13.jpg)
13
Keys to Rosetta’s Success
Ease Of Use
Rugged / Robust
Integrated
Interoperable
Physician / Paramedic Acceptance
![Page 14: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/14.jpg)
14
Tell Me More!
How does it work?
What does it cost?
Who do we contact?
![Page 15: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/15.jpg)
15
How does it work? 12-Lead Data Flow…
Monitor Cable (RS-232)
Radio Cable(Audio / PTT)
VHFUHF
800 TrunkedGSM Phone
![Page 16: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/16.jpg)
16
How does it work? - Alternate Method Fax from monitor company system
12-Lead Data Flow…
CAREpoint EMS WorkstationsDisplay – Print - Forward
IP Cellular
Forward to Hosp.
Fax, e-mail
Monitor’s Receiving Station
Auto-FAX
![Page 17: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/17.jpg)
17
What Does it cost?
Rosetta-Lt
$800+
Cables
Rosetta-Rx
$2000 +
Printer
CAREpoint
20 -30K
(config/options)
![Page 18: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/18.jpg)
18
Sampling of GD’s Hundreds of Customers…
Richland County - SCBaptist Health - ALWellmont Healthcare - TNLoma Linda University Med. Cntr. CA
New York City FD EMS - FDNYSpartanburg Regional EMS - SCUniversity of Chicago - ILCook County Hosp - ILNew York Presbyterian – NYOcean City EMS Anne Arundel County FDTucson FD-EMS - AZMilwaukee County EMS -WI
![Page 19: EMS 12-Lead Transmission Solution](https://reader035.vdocuments.site/reader035/viewer/2022062707/5583cb98d8b42a7c758b5060/html5/thumbnails/19.jpg)
19
Need More Information?
Refer to the Rosetta Product Description document available on the GD web site.
Contact:
General DevicesSales Department