emissions & odours 2019 - certech · emissions & odours 2019 measurement of aldehydes such...

23
Online Gas Analyzer Experts Online Gas Analyzer Experts Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68 [email protected] 15 rue d’ Artiguelongue, 33240, St Antoine

Upload: others

Post on 28-Jun-2020

6 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer Experts

Online Gas Analyzer Experts

Emissions & Odours 2019

Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO

analyzer

Anoulak Elfassi

+33 6 60 30 70 68

[email protected]

15 rue d’Artiguelongue, 33240, St Antoine

Page 2: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

2

▪ French manufacturer for online analyzers :

▪ autoGC

▪ Multiplexing system

▪ Calibration system

▪ Gas generators

▪ Parternship to provide all-in-one solution

▪ Amount of certifications per country and on top 3 of providers selected by US EPA on autoGC evaluation for VOCsmeasurement in ambient air

Chromatotec overview

Page 3: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

1975 Medor range launched on the market by RN Electronique with « Gaz De France », (Research Center)

1986 Foundation of the firm CHROMATO-SUD by the current managers in BORDEAUX

1990 Creation of airmotec AG SAS, Switzerland (Instruments dedicated to the analysis of ambient air -technology coming from the Swiss pharmaceutical industry).

1996 airmotec AG, Chromato-Sud and RN Electronique integrated in Chromatotec Group

2001 airmOZONE and VistaCHROM development

Chromatotec Inc in Houston

2002 Launching of air toxic range with new PID detection in ambient air and industrial hygiene

2005 New Office in Beijing

2009 ASTM Standard Test Method for Online Measurement of Sulfur Compounds in Natural Gas (MEDOR range)

Analyzers for Hazardous areas range launched

2010 Chinese certification for VOCs system

2011 European mCERTs certification for VOCs analyser EN 14662-3

2012 Auto GC/MS analyzer for industrial or laboratory application with trap

40 years of expertise in gas analysis

Page 4: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

2013 Establishment of a Chinese subsidiary in Beijing

European mCERTs certifications: EN 14662-3 / EN 15267-1 / EN 15267-2

2014 ISO 9001 certification / GOST certification

US EPA autoGC evaluation test: the only rack mounted autoGC selected by the national US EPA for VOCs monitoring

2015 ATEX certification for Zone 1 and 2

2016 Introduction of PAH analyzer on AQMS market

2017 Introduction of Formaldehyde analyzer on AQMS market

Expansion of the production site in Virsac

New building for IT department : software, hardware and network team

2018 New Office in Houston for customer support improvement in Americas

Extension of the Beijing Office for increased customer support in Asia including India

40 years of expertise in gas analysis

Page 5: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer ExpertsChromatotec presence in the world

2300 m² on 4 offices

2 in Europe, 1 in Asia

and 1 in America

Beijing (China)Chromatotec Trading Co., Ltd. :Sales and cust. ServiceExpansion planned in 2018 for laboratory and customer support

Houston (USA)Chromatotec Inc : Sales and cust. ServiceNew Office fully operationalbeginning of 2019

Saint-Antoine (33), France- Chromatotec Group Holding - airmotec AG SAS: sales, R&D - Chromatotec®: cust. & admin. ServicesVirsac (33), France - Chromato-Sud SARL:

Production site

Page 6: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer ExpertsCertificates

Worldwide recognition with certifications relating to the relevant standards, performed by :

• US EPA use Chromatotec solutions (2009) and have selected the company as one of the top 3 of 88companies working on Ambient market

• EN 14662-3 (2015): Method to establish the performance criteria for the measurement of Benzeneconcentration using an automated sampling pump with in-situ gas chromatography.

Laboratory and on-site tests have been passed successfully by the NPL

Benzene and 12 other VOCs have been tested

• airmotec/Chromatotec® : Unique manufacturer with EN 14662-3En 14662-3: compulsory for ambient air monitoring in Europe

• ATEX certification

2006 20132009 201020091996 2012 2014

Page 7: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

7

▪ On-line and on field monitoring (not only lab)

▪ Speciation of VOCs & Sulfur compounds

▪ Automatic data validation

▪ Standalone solutions (no need of gas cylindersor specific standards during routine use)

▪ Design of solutions (GC-PID, GC-FID, GC-TCD,

GC-FID-MS, GC-FPD or GC-SSWCD, FTUV and more)

▪ Tracking ppb/ppt concentration levels in air orprocess

▪ Tracking up to % concentration level for specificprocess

Our specificity

Page 8: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

• Formaldehyde is present in :

- Chemical, pharmaceutical, funeral industries

- Paper plants

- Indoor air (paintings, coatings)

• Formaldehyde effects :

- Irritating, breathing issues ( <500 ppb)

- Carcinogenic ( >500 ppb)

- Risk of death ( > 20 ppm)

8

Why analyzing formaldehyde ?

https://www.atousante.com/risques-professionnels/cmr-cancerogenes-mutagenes-toxiques-reproduction/formaldehyde/formaldehyde-effets-sante/

Page 9: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

9

Measurement principle : GC FID

Sampling trap Metallic column Flame Ionization Detector(FID)

➢ Separative method

➢ Identification with retention time

➢ Linearity for every concentrations range

Page 10: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

10

airmoHCHO external overview

• Auto GC-FID

• Embedded computer

• Integrated software

• Air, N2, H2 generators canbe integrated

• Cabinet version

• Internal calibration with permeation tubes

Page 11: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

11

airmoHCHO internal overview

Pressure regulator for permeationflow adjustement

Air flow regulator for flame

Pressure regulator for carrier gas flow on the column

H2 flow regulator for flame

Injection valve 6-ports withsampling trap and pre-colulmn

Methanizer

Oven with programabletemperatude and metalliccolumn inside

Permeation oven

FID Detector

Page 12: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

12

Measurement principle : analysis cycle

• Sampling step :

- Pre concentrate VOCs in the trap

- Realized at the end of analysis cycle to reduce cycle time

• Analysis step :

- Injection of trapped VOCs in the column by thermo desorption

- Separation in analytical column

- Mehanization of VOCs

- Detection by FID

Page 13: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

13

Methanization

• Principle

- Transform aldehyde compounds such as formaldehyde to methane

- Using ruthenium for catalyse

• Advantages

- HCHO has a bad response with FID Detector

- CH4 is well detected by FID

Page 14: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

14

Step 1 : Thermo-desorption

TRAP CH4

H2

Pre-column Metallic column

Methanizer FID

VOCs + formaldehyde

Page 15: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

15

Step 2 : First separation

CH4

Pre-column Metallic column

Methanizer FID

Heavy VOCs Formaldehyde + light compounds

H2

Separation of heavy compounds in pre-column

Page 16: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

16

Step 3 : Separation of light compounds

CH4

Pre-column Metallic column

Methanizer FID

Heavy VOCs Formaldehyde

H2

Methanizer is closed to eject light compounds

Event

Page 17: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

17

Step 4 : Methanization of formaldehyde

CH4

Pre-column Metallic column

Methanizer FID

Heavy VOCs

H2

Formaldehyde is injected intomethanizer

Formaldehyde

Page 18: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

18

Step 5 : Detection of formaldehyde

CH4

Pre-column Metallic column

Methanizer FID

Heavy VOCs

H2

Methanized formaldehyde goes to FID for quantification

Methane

Page 19: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

19

Results for permeation tube analysis

• Configuration permation tube :- [HCHO] = 3028 ppb- Gas Temperature : 90°C- Gas flow : 83.3 ml/min- Sampling time : 300s- Acquisition time : 420s

• Results :- [HCHO] = 3035 ppb- Theorical deviation : 0,2%

Page 20: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

20

Ambient air analysis

• Cycle time : 30 min• Concentration : 32.6 ppb• Limit of Detection : 3.8 ppb

Page 21: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

21

Advantage of this solution

➢ Short cycle time (30 min) compared to ISO 16000-3:2011

➢Automatic solution

➢ Few interferents with chromatography

➢ Visualisation of data

Page 22: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

22

Conclusion

➢ Crucial need to monitor formaldehyde

➢Using GC-FID for online measurement

➢ airmoHCHO is a fully autonomous system

➢ Possibility to measure acetaldehyde methanol and ethanol in addition

Page 23: Emissions & Odours 2019 - Certech · Emissions & Odours 2019 Measurement of Aldehydes such as Formaldehyde in ambient air using airmoHCHO analyzer Anoulak Elfassi +33 6 60 30 70 68

Online Gas Analyzer ExpertsOnline Gas Analyzer Experts

Thank you for your attention

[email protected]

Tel +33(0)6 60 30 70 68