emc trf template - sc04.alicdn.com

44
Shenzhen HUAK Testing Technology Co., Ltd. Report No.: HK1905231131-1ER TEST REPORT EN 55015: 2013/A1:2015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment EN 61547: 2009 Equipment for general lighting purposes - EMC immunity requirements Report Reference No. ..................... : HK1905231131-1ER Compiled by ( position+printed name+signature) .. : File administrators Gary Qian Supervised by ( position+printed name+signature) .. : Technique principal Leo Zhong Approved by ( position+printed name+signature) .. : Manager James Zhou Date of issue ..................................... : May 23,2019 Testing Laboratory Name .............. : Shenzhen HUAK Testing Technology Co., Ltd. Address............................................. : 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park, Heping Community, Fuhai Street, Bao’an District, Shenzhen, China Applicant’s name ............................ : ECEEN Electronic Limited Address............................................. : 3F, B Building, 3rd Xinsheng Technology Park, No.29 Pingxinan Road, Xinsheng Community, Longgang district, Shenzhen, Guangdong China Test specification: Standard ........................................... : EN 55015: 2013/A1:2015 EN 61547: 2009 EN 61000-3-2: 2014 EN 61000-3-3: 2013 Shenzhen CTA Testing Technology Co., Ltd. All rights reserved. This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd.. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context. Test item description .................... : LED Turn Signal Vest Pack Trade Mark ....................................... : / Manufacturer ................................... : SHENZHEN LIGUANGYUAN ELECTRONICS CO.,Ltd Huaqiang road in Shenzhen District of Futian, Sun Asia N1B077, Shenzhen, Guangdong, China Model/Type reference....................... : CL-001, CL-002, RL-3528URC-LGY Listed Models ................................... : / Ratings Voltage ................................ : Transmitter: DC3V from Battery Receiver: DC 3.7V and DC 5V From External circuit Result................................................ : Pass

Upload: others

Post on 25-Jan-2022

2 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EMC TRF Template - sc04.alicdn.com

Shenzhen HUAK Testing Technology Co., Ltd.

Report No.: HK1905231131-1ER

TEST REPORT

EN 55015: 2013/A1:2015 Limits and methods of measurement of radio disturbance characteristics of electrical

lighting and similar equipment EN 61547: 2009

Equipment for general lighting purposes - EMC immunity requirements

Report Reference No. ..................... : HK1905231131-1ER

Compiled by

( position+printed name+signature) .. :

File administrators Gary Qian

Supervised by

( position+printed name+signature) .. :

Technique principal Leo Zhong

Approved by

( position+printed name+signature) .. :

Manager James Zhou

Date of issue ..................................... : May 23,2019

Testing Laboratory Name .............. : Shenzhen HUAK Testing Technology Co., Ltd.

Address............................................. : 1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park,

Heping Community, Fuhai Street, Bao’an District, Shenzhen, China

Applicant’s name ............................ : ECEEN Electronic Limited

Address............................................. : 3F, B Building, 3rd Xinsheng Technology Park, No.29 Pingxinan Road, Xinsheng Community, Longgang district, Shenzhen, Guangdong China

Test specification:

Standard ........................................... : EN 55015: 2013/A1:2015 EN 61547: 2009

EN 61000-3-2: 2014

EN 61000-3-3: 2013

Shenzhen CTA Testing Technology Co., Ltd. All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the Shenzhen CTA Testing Technology Co., Ltd. is acknowledged as copyright owner and source of the material. Shenzhen CTA Testing Technology Co., Ltd.. takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.

Test item description .................... : LED Turn Signal Vest Pack

Trade Mark ....................................... : /

Manufacturer ................................... : SHENZHEN LIGUANGYUAN ELECTRONICS CO.,Ltd Huaqiang road in Shenzhen District of Futian, Sun Asia N1B077, Shenzhen, Guangdong, China

Model/Type reference ....................... : CL-001, CL-002, RL-3528URC-LGY

Listed Models ................................... : /

Ratings Voltage ................................ : Transmitter: DC3V from Battery

Receiver: DC 3.7V and DC 5V From External circuit

Result ................................................ : Pass

Page 2: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 2 of 44

EMC - T E S T R E P O R T

Test Report No. :

HK1905231131-1ER May. 23,2019 ______________________________________________________________________________________________

Date of issue

Equipment under Test : LED Turn Signal Vest Pack

Model / Type : CL-001, CL-002, CL-003, CL-004, CL-005, CL-006, CL-007, CL-008, CL-009, CL-010, CL-011, CL-012, CL-013, CL-014, CL-015, CL-016, CL-017, CL-018, CL-019, CL-020, RL-3528URC-LGY

Listed Model : /

Applicant : ECEEN Electronic Limited

Address : 3F, B Building, 3rd Xinsheng Technology Park, No.29 Pingxinan Road, Xinsheng Community, Longgang district, Shenzhen, Guangdong China

Manufacturer : ECEEN Electronic Limited

Address 3F, B Building, 3rd Xinsheng Technology Park, No.29 Pingxinan Road, Xinsheng Community, Longgang district, Shenzhen, Guangdong China

Test Result

Pass

The test report merely corresponds to the test sample. It is not permitted to copy extracts of these test result without the written permission of the test laboratory.

Page 3: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 3 of 44

Contents

1 . T E S T S T A N D A R D S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

2 . S U M M A R Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

2.1. General Remarks 5 2.2. Equipment Under Test 5 2.3. Short description of the Equipment under Test (EUT) 5 2.4. EUT configuration: 6 2.5. Performance level 7

3 . T E S T E N V I R O N M E N T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

3.1. Address of the test laboratory 8 3.2. Environmental conditions 8 3.3. Test Description 8 3.4. Statement of the measurement uncertainty 8 3.5. Equipments Used during the Test 9

4 . T E S T C O N D I T I O N S A N D R E S U L T S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2

4.1. Conducted disturbance 12 4.2. Radiated Emission 15 4.3. Magnetic Field Emission 18 4.4. Harmonic current 22 4.5. Voltage Fluctuation and Flicker 23 4.6. Electrostatic discharge 24 4.7. Radiated, radio-frequency, electromagnetic field 26 4.8. Electrical fast transients / Burst 28 4.9. Surge 30 4.10. Conducted disturbances induced by radio-frequency fields 32 4.11. Magnetic Field Immunity 34 4.12. Voltage Dips and Interruptions 34

5 . T E S T S E T - U P P H O T O S O F T H E E U T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 6

6 . E X T E R N A L A N D I N T E R N A L P H O T O S O F T H E E U T . . . . . . . . . . . . . . . . . . . . . . . . 3 9

Page 4: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 4 of 44

1 . T E S T S T A N D A R D S The tests were performed according to following standards: EN 55015: 2013/A1:2015 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment

EN 61547: 2009 Equipment for general lighting purposes - EMC immunity requirements

EN 61000-3-2: 2014 Electromagnetic compatibility (EMC) -- Part 3-2: Limits - Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)

EN 61000-3-3: 2013 Electromagnetic compatibility (EMC) -- Part 3-3: Limits - Limitation of voltage changes,

voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≀ 16 A

per phase and not subject to conditional connection

Page 5: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 5 of 44

2 . S U M M A R Y

2.1. General Remarks

Date of receipt of test sample : May.15, 2019

Testing commenced on : May.16, 2019

Testing concluded on : May.23, 2019

2.2. Equipment Under Test

Power supply system utilised Power supply voltage : 230V / 50 Hz o 120V / 60Hz o 12 V DC o 24 V DC o Other (specified in blank below) /

2.3. Short description of the Equipment under Test (EUT)

The EUT LED Turn Signal Vest Pack is consists of three parts, the remote control, Back clip. In the this system the remote control work as transmitter, the Back clip as receiver, the parts communicated with each other over 433MHz wireless technology.

Product Name: LED Turn Signal Vest Pack

Model/Type reference: RL-3528URC-LGY

Serial Model CL-001, CL-002, CL-003, CL-004, CL-005, CL-006, CL-007, CL-008, CL-009, CL-010, CL-011, CL-012, CL-013, CL-014, CL-015, CL-016, CL-017, CL-018, CL-019, CL-020

Power supply: Transmitter: DC3V from Battery Receiver: DC 3.7V and DC 5V From External circuit

Adapter(Auxiliary test Provided by the laborator)

Mode:EP-TA20CBC

Input:AC100-240V-50/60Hz0.5A

Output:DC 5V,2A

Wireless technology

Frequency band: 433,050 MHz to 434,790 MHz

Operating frequency: 433.92MHz

Modulation type: ASK

Spread spectrum method: Duty cycle Polite spectrum access

Receiver category:

Category 1: Category 1 is a high performance level of receiver. In particular to be used where the operation of a SRD may have inherent safety of human life implications.

Category 1.5: Category 1.5 is an improved performance level of receiver category 2.

Category 2: Category 2 is standard performance level of receiver.

Category 3:

Category 3 is a low performance level of receiver. Manufacturers have to be aware that category 3 receivers are not able to work properly in case of coexistence with some services such as a mobile radio service in adjacent bands. The manufacturer shall provide another mean to overcome the weakness of the radio link or accept the failure.

Antenna type: Integrated antenna

Note: For more details, refer to the user’s manual of the EUT.

Page 6: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 6 of 44

EUT operation mode

Operation mode

Mode 1 LED Lighting

2.4. EUT configuration:

The following peripheral devices and interface cables were connected during the measurement:

● - supplied by the manufacturer

○ - Supplied by the lab

Page 7: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 7 of 44

2.5. Performance level

The test results shall be classified in terms of the loss of function or degradation of performance of the equipment under test relative to a performance criteria defined by its manufacturer or the requestor of the test, or agreed between the manufacturer and the purchaser of the product. Examples of functions defined by the manufacturer to be evaluated during testing include, but are not limited to, the following:

— essential operational modes and states;

— tests of all peripheral access(hard disks, floppy disks, printers, keyboard, mouse, etc.);

— quality of software execution

— quality of data display and transmission

— quality of speech transmission

Definition related to the performance level:

■ based on the used product standard

o based on the declaration of the manufacturer, requestor or purchaser

Criterion A:

During the test no change of the luminous intensity shall be observed and the regulating control, if any, shall operate during the test as intended.

Criterion B:

During the test the luminous intensity may change to any value. After the test the luminous intensity shall be restored to its initial value within 1 min.

Regulating controls need not function during the test, but after the test the mode of the control shall be the same as before the test provided that during the test no mode changing commands were given.

Criterion C:

During and after the test any change of the luminous intensity is allowed and the lamp(s) may be extinguished. After the test, within 30 min, all functions shall return to normal if necessary by temporary interruption of the mains supply and/or operating the regulating control.

Page 8: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 8 of 44

3 . T E S T E N V I R O N M E N T

3.1. Address of the test laboratory

1F, B2 Building, Junfeng Zhongcheng Zhizao Innovation Park,Heping Community, Fuhai Street, Bao’an District, Shenzhen, China

3.2. Environmental conditions

During the measurement the environmental conditions were within the listed ranges:

Temperature: 15-35 ° C

Humidity: 30-60 %

Atmospheric pressure: 950-1050mbar

3.3. Test Description

Emission Measurement

Magnetic Field Emission (0.009~30MHz)

EN 55015: 2013/A1:2015 PASS

Conducted Disturbance EN 55015: 2013/A1:2015 PASS

Radiated Emission EN 55015: 2013/A1:2015 PASS

Harmonic Current EN 61000-3-2: 2014 N/A

Voltage Fluctuation and Flicker EN 61000-3-3: 2013 PASS

Immunity Measurement

Electrostatic Discharge EN 61547: 2009

EN 61000-4-2: 2009 PASS

RF Field Strength Susceptibility EN 61547: 2009

EN 61000-4-3: 2006+A1:2008+A2:2010 PASS

Electrical Fast Transient/Burst Test

EN 61547: 2009

EN 61000-4-4: 2012 PASS

Surge Test EN 61547: 2009

EN 61000-4-5: 2014 PASS

Conducted Susceptibility Test EN 61547: 2009

EN 61000-4-6: 2014 PASS

Power Frequency Magnetic Field Susceptibility Test

EN 61547: 2009

EN 61000-4-8: 2010 N/A

Voltage Dips and Interruptions Test

EN 61547: 2009

EN 61000-4-11: 2004 PASS

N/A means “not applicable”. The measurement uncertainty is not included in the test result

3.4. Statement of the measurement uncertainty

The data and results referenced in this document are true and accurate. The reader is cautioned that there may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was

Page 9: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 9 of 44

calculated for all measurements listed in this test report acc. to CISPR 16 - 4 “Specification for radio disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC Measurements” and is documented in the Shenzhen HUAK Testing Technology Co., Ltd.. quality system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in additional deviation. The manufacturer has the sole responsibility of continued compliance of the device. Hereafter the best measurement capability for Shenzhen HUAK Testing Technology Co., Ltd. is reported:

Test

Range

Measurement Uncertainty

Notes

Radiated Emission 30~300MHz 4.24dB (1)

Conducted Disturbance 0.009~30MHz 3.21dB

Magnetic Field Emission 9KHz to 30MHz 3.51dB (1)

(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence level using a coverage factor of k=2.

3.5. Equipments Used during the Test

CONDUCTED EN/ASSION

Item Kind of

Equipment Manufacturer Type No. Last calibration Calibrated until

Calibration period

1 LISN R&S ENV216 Dec. 28, 2018 Dec. 27, 2019 1 year

2 LISN R&S ENV216 Dec. 28, 2018 Dec. 27, 2019 1 year

3 EN/A Test

Receiver R&S ESCI-7 Dec. 28, 2018 Dec. 27, 2019 1 year

4

Wideband

Radio

Communication

tester

R&S CMW500 Dec. 28, 2018 Dec. 27, 2019 1 year

RADIATED TEST SITE

Item Kind of

Equipment Manufacturer Type No. Last calibration Calibrated until

Calibration period

1 Spectrum analyzer

R&S FSU26 Dec. 28, 2018 Dec. 27, 2019 2 year

2

Trilog Broadband

Antenna Schwarzbeck VULB9163 Dec. 28, 2018 Dec. 27, 2019 1 year

3 Double Ridged Horn Antenna

R&S HF907 Dec. 28, 2018 Dec. 27, 2019 1 year

4 Pre-Amplifier R&S SCU-01 Dec. 28, 2018 Dec. 27, 2019 2 year

5 Pre-amplifier A.H. PAM0-0118 Dec. 28, 2018 Dec. 27, 2019 1 year

6 RF Cable R&S R01 Dec. 28, 2018 Dec. 27, 2019 1 year

7 RF Cable R&S R02 Dec. 28, 2018 Dec. 27, 2019 1 year

8 RF Cable R&S R01 Dec. 28, 2018 Dec. 27, 2019 1 year

9 RF Cable R&S R02 Dec. 28, 2018 Dec. 27, 2019 1 year

Page 10: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 10 of 44

HARMONICS AND FILCK

Item Kind of

Equipment Manufacturer Type No. Last calibration Calibrated until

Calibration period

1 Harmonic

flicker tester

California

Instruments 5001ix Dec. 28, 2018 Dec. 27, 2019 1 year

2

Wideband

Radio

Communication

tester

R&S CMW500 Dec. 28, 2018 Dec. 27, 2019 1 year

ESD

Item Kind of

Equipment Manufacturer Type No. Last calibration Calibrated until

Calibration period

1 ESD device Schloder SESD 216 Dec. 28, 2018 Dec. 27, 2019 1 year

2

Wideband

Radio

Communication

tester

R&S CMW500 Dec. 28, 2018 Dec. 27, 2019 1 year

RS

Item Kind of

Equipment Manufacturer Type No. Last calibration Calibrated until

Calibration period

1 Signal

generator Agilent 83630A Dec. 28, 2018 Dec. 27, 2019 1 year

2 Hf antenna Schwarzbeck LB-180400-KF Dec. 28, 2018 Dec. 27, 2019 2 year

3 Power amplifier R&S NTWPA-

1060040E Dec. 28, 2018 Dec. 27, 2019 1 year

4 Broadband

antenna Schwarzbeck VULB 9163 Dec. 28, 2018 Dec. 27, 2019 2 year

5 Power amplifier R&S 5225F Dec. 28, 2018 Dec. 27, 2019 1 year

6

Wideband

Radio

Communication

tester

R&S CMW500 Dec. 28, 2018 Dec. 27, 2019 1 year

SURGE, EFT/BURST, VOLTAGE INTERRUPTION/DIPS

Item Kind of

Equipment Manufacturer Type No. Last calibration Calibrated until

Calibration period

1 Full-featured

immunity tester HTEC HV1P16T Dec. 28, 2018 Dec. 27, 2019 1 year

2 Group pulse

coupling clamp HTEC H3C Dec. 28, 2018 Dec. 27, 2019 1 year

3

Wideband

Radio

Communication

tester

R&S CMW500 Dec. 28, 2018 Dec. 27, 2019 1 year

INJECTION CURRENT

Item Kind of

Equipment Manufacturer Type No. Last calibration Calibrated until

Calibration period

1

Integrated Conduction

Sensitivity Test System

Schloder CDG6000 Dec. 28, 2018 Dec. 27, 2019 1 year

2

Wideband

Radio

Communication

tester

R&S CMW500 Dec. 28, 2018 Dec. 27, 2019 1 year

Page 11: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 11 of 44

Magnetic Field Emission

Item Test Equipment Manufacturer Model No. Last calibration Calibrated until Calibration

period

1 Triple-Loop Antenna

Beijing Da Ze Technology

Co.,Ltd. ZN23401 Dec. 28, 2018 Dec. 27, 2019 1 year

2 EMI Test Receiver R&S ESCI Dec. 28, 2018 Dec. 27, 2019 1 year

The calibration interval was one year.

Page 12: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 12 of 44

4 . T E S T C O N D I T I O N S A N D R E S U L T S

4.1. Conducted disturbance

4.1.1. Limits of disturbance

Frequency Range (MHz) Limits (dBuV)

Quasi-Peak Average

9 K~50 K 110 —

50 K~150 K 90~80 —

150 K~0.5 M 66~56 56~46

0.5 M5.0 M 56 46

5.0 M~30 M 60 50

Note: (1) The tighter limit shall apply at the edge between two frequency bands.

4.1.2. TEST CONFIGURATION

4.1.3. TEST PROCEDURE

EUT is placed on a nonmetal table which is 0.8 meter above the grounded reference plane. Connect the power line of the EUT to the LISN which is connected to receiver by coaxial line, then disturbance of the neutral line and live line can be detected by the receiver.

4.1.4. CLIMATIC CONDITIONS

ambient temperature : 25 ℃

relative humidity: 52%

atmospheric pressure: 960 mbar

4.1.5. TEST RESULTS

EUT LISN

RECEIVER

RGP

Page 13: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 13 of 44

Test mode: Mode 1 Polarization L

Page 14: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 14 of 44

Test mode: Mode 1 Polarization N

Page 15: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 15 of 44

4.2. Radiated Emission

4.2.1. Limits of disturbance

Frequency (MHz) Distance (Meters) Field Strengths Limits (dBV/m)

30 ~ 230 3 40

230 ~ 300 3 47

Note: (1) The tighter limit shall apply at the edge between two frequency bands.

(2) Distance refers to the distance in meters between the test instrument antenna and the closest point of any part of the E.U.T.

4.2.2. TEST CONFIGURATION

4.2.3. TEST PROCEDURE

EUT is tested in Semi-Anechoic Chamber. EUT is placed on a nonmetal table which is 0.8 meter above a grounded turntable. The turntable can rotate 360 degrees to determine the azimuth of the maximum emission level. EUT is set 3 meters away from the center of receiving antenna. The antenna can move up and down from 1 to 4 meter to find out the maximum emission level. Both horizontal and vertical polarizations of the antenna are set on the test.

4.2.4. CLIMATIC CONDITIONS

ambient temperature : 24 ℃

relative humidity: 48%

atmospheric pressure: 955 mbar

4.2.5. TEST RESULTS

We tested all modes, and recorded the worst case at the mode 1

EUT

SEMI-ANECHOIC CHAMBER

RECEIVER

3 METRES

ANTENNA MAST

Page 16: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 16 of 44

Test mode: Mode 1 Polarization Horizontal

Page 17: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 17 of 44

Test mode: Mode 1 Polarization Vertical

Page 18: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 18 of 44

4.3. Magnetic Field Emission

4.3.1. Limits of disturbance

Frequency (MHz) Limit For Loop Diameter of 2m (dBA)

9K~70K 88

70K~150K 88 ~58

150K~3.0M 58~22

3.0M~30M 22

Note: (1) The tighter limit shall apply at the edge between two frequency bands.

(2) Distance refers to the distance in meters between the test instrument antenna and the

closest point of any part of the E.U.T.

4.3.2. TEST CONFIGURATION

4.3.3. TEST PROCEDURE

EUT is placed in the center of triple-loop antenna (Diameter is 2m). Turn on the neon sign, and then the induced current in the loop antenna can be detected by a current probe and measured by the receiver. Three field directions shall be measured in sequence.

4.3.4. CLIMATIC CONDITIONS

ambient temperature : 24 ℃

relative humidity: 45%

atmospheric pressure: 952 mbar

4.3.5. TEST RESULTS

We tested all modes, and recorded the worst case at the mode 2

EUT

RECEIVER

TRIPLE-LOOP ANTENNA

Page 19: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 19 of 44

Test mode: Mode 1 Polarization X

Page 20: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 20 of 44

Test mode: Mode 1 Polarization Y

Page 21: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 21 of 44

Test mode: Mode 1 Polarization Z

Page 22: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 22 of 44

4.4. Harmonic current

4.4.1. LIMITS OF HARMONIC CURRENt

Please refer to EN 61000-3-2.

4.4.2. TEST CONFIGURATION

4.4.3. TEST PROCEDUR

Please refer to EN 61000-3-2 for the measurement methods.

4.4.4. CLIMATIC CONDITIONS

ambient temperature : 25 ℃

relative humidity: 47 %

atmospheric pressure: 958 mbar

4.4.5. TEST RESULTS

EUT is powered by an external adapter, So this test item is not applicable for the EUT.

Harmonics And Flicker

Analyzer

Controller Computer

EUT

0.8m

To AC Source

Page 23: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 23 of 44

4.5. Voltage Fluctuation and Flicker

4.5.1. LIMIT OF VOLTAGE FLUCTUATION AND FLICKER

Please refer to EN 61000-3-3.

4.5.2. TEST CONFIGURATION

4.5.3. TEST PROCEDUR

Please refer to EN 61000-3-3 for the measurement methods.

4.5.4. TCLIMATIC CONDITIONS

ambient temperature : 25 ℃

relative humidity: 47%

atmospheric pressure: 958mbar

4.5.5. TEST RESULTS

MMaaxxiimmuumm FFlliicckkeerr rreessuullttss

EUT is powered by an external adapter, So this test item is not applicable for the EUT.

Harmonics And Flicker

Analyzer

Controller Computer

EUT

0.8m

To AC Source

Page 24: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 24 of 44

4.6. Electrostatic discharge

4.6.1. TEST LEVELS OF ELECTROSTATIC DISCHARGE

Level Test Voltage

Contact Discharge (KV)

Test Voltage

Air Discharge (KV)

1 2 2

2 4 4

3 6 8

4 8 15

X Special Special

Performance criterion: B

4.6.2. TEST CONFIGURATION

4.6.3. TEST PROCEDURE

Contact Discharge: The ESD generator is held perpendicular to the surface to which the discharge is applied and the tip of the discharge electrode touch the surface of EUT. Then turn the discharge switch. The generator is then re-triggered for a new single discharge and repeated at least 10 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed Air Discharge: Air discharge is used where contact discharge can’t be applied. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the EUT. After each discharge, the discharge electrode shall be removed from the EUT. The generator is then re-triggered for a new single discharge and repeated at least 10 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed.

Indirect discharge for horizontal coupling plane: At least 10 single discharges shall be applied to the horizontal coupling plane, at points on each side of the EUT.

Page 25: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 25 of 44

Indirect discharge for vertical coupling plane: At least 10 single discharges shall be applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the coupling plane, with this plane in sufficient different positions that the four faces of the EUT are completely illuminated.

4.6.4. CLIMATIC CONDITIONS

ambient temperature : 25 ℃

relative humidity: 50%

atmospheric pressure: 960 mbar

4.6.5. TEST RESULTS

Description of Discharge Point

Contact Discharge Test points Air Discharge

○ Metallic Screws ● Plastic Button

● Metallic Case ● Plastic Case(gap)

○ Metallic Connect ports ○ Plastic Connect Ports

○ Metallic Junctions ○ Plastic Junctions

○ Others (Antenna Port) ● Others

Result of Final Tests (Mode 1)

Point of Discharge Applied Voltage

(KV)

Total No. of Discharge

(Each Point) Results

Criteria Level

Remark

Air Test Point ±8 20 Pass B

Contact Discharge Test Points

±4 20 Pass B

VCP (4 sides) ±4 20 Pass B

HCP (4 sides) ±4 20 Pass B

Remarks: During the test no deviation was detected to the selected operation mode(s).

Page 26: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 26 of 44

4.7. Radiated, radio-frequency, electromagnetic field

4.7.1. TEST LEVELS OF RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD

Level Field Strength (V/m)

1. 1

2. 3

3. 10

X Special

Performance criterion: A

4.7.2. TEST CONFIGURATION

4.7.3. TEST PROCEDURE

EUT and its auxiliary instrument are placed on a turntable which is 0.8 meter above ground. The center of the transmitting antenna mounted on an antenna mast is set 3 meter away from the EUT. During the test, each of the four sides of EUT will face the transmitting antenna with the turntable cycled. Both horizontal and vertical polarization of the antenna are set on test and measured individually.

4.7.4. CLIMATIC CONDITIONS

ambient temperature : 25 ℃

relative humidity: 50%

atmospheric pressure: 960 mbar

ABSORBING MATERIALS

SIGNAL GENERATOR SEMI-ANECHOIC CHAMBER

3 METRES

EUT

AMPLIFIER

Page 27: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 27 of 44

4.7.5. TEST RESULTS

Result of Final Tests (Mode 1)

Freq. Range (MHz)

Field Modulation Polarity Position Criteria Level

Result (Pass/Fail)

Remark

80-1000 3V/m Yes H / V Front A PASS -

80-1000 3V/m Yes H / V Right A PASS

80-1000 3V/m Yes H / V Back A PASS -

80-1000 3V/m Yes H / V Left A PASS -

Remarks: During the test no deviation was detected to the selected operation mode(s).

Page 28: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 28 of 44

4.8. Electrical fast transients / Burst

4.8.1. TEST LEVELS OF ELECTRICAL FAST TRANSIENT/BURST TEST

Open circuit output test voltage and repetition rate of the impulses

Level

On power port, PE On I/O signal, data and control

ports

V peak(KV) Repetition rate (KHz) Voltage peak Repetition rate

(KHz)

1. 0.5 5 or 100 0.25 5 or 100

2. 1 5 or 100 0.5 5 or 100

3. 2 5 or 100 1 5 or 100

4. 4 5 or 100 2 5 or 100

X Special Special Special Special

Performance criterion: B

4.8.2. T EST CONFIGURATION

4.8.3. TEST PROCEDURE

AC power input lines:

—EUT is connected to coupling/decoupling network which couples the EFT signal to power input lines. During the test, both polarities of the test voltage should be applied and the duration of the test can’t be less than 2mins.

4.8.4. CLIMATIC CONDITIONS

ambient temperature : 23 ℃

relative humidity: 44%

atmospheric pressure: 950 mbar

Page 29: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 29 of 44

4.8.5. TEST RESULTS

Results of Final Tests (Mode 1)

Impulse Frequency: 5 kHz Tr/Th: 5/50ns Burst Duration: 15ms Burst Period: 300ms

Test duration: 120s

Injection Line Voltage

(kV) Repetition rate (kHz)

Injected Method

Criterion Result (Pass

/ Fail)

Line ±1 5 Direct B Pass

Neutral ±1 5 Direct B Pass

PE

Line + Neutral ±1 5 Direct B Pass

L + PE

N + PE

L + N + PE

Remarks: During the test no deviation was detected to the selected operation mode(s).

Page 30: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 30 of 44

4.9. Surge

4.9.1. TEST LEVELS OF ELECTRICAL FAST TRANSIENT/BURST TEST

Performance criterion: C

4.9.2. TEST CONFIGURATION

4.9.3. TEST PROCEDURE

In this test, the 1.2/50us& 8/20us surge generator must be used for AC power ports. The voltage for line to earth coupling mode is twice of that for line to line. At least 5 positive and 5 negative (polarity) surge signal with a maximum 1/min repetition rate are injected to AC power lines from 4 different phase angles during the test.

4.9.4. CLIMATIC CONDITIONS

ambient temperature : 23 ℃

relative humidity: 44%

atmospheric pressure: 950 mbar

Level Test Voltage (KV)

1 0.5

2 1.0

3 2.0

4 4.0

* Special

Surge Immunity Test

Controller Computer

EUT

0.8m

To AC Source

Page 31: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 31 of 44

4.9.5. TEST RESULTS

Results of Final Tests (Mode 1) Voltage Waveform: 1.2/50 us Current Waveform: 8/20 us Number of surges: 5 Surges/Phase angle Repetition rate: 60 s

Coupling Line Voltage

(kV) Phase angle

Polarity Coupling Method

Criterion Result

(Pass/Fail)

Line + Neutral 1 90 Pos Capacitive C Pass

Line + Neutral 1 270 Neg Capacitive C Pass

L + PE

L + PE

N + PE

N + PE

Remarks: During the test no deviation was detected to the selected operation mode(s).

Page 32: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 32 of 44

4.10. Conducted disturbances induced by radio-frequency fields

4.10.1. TEST LEVELS OF CONDUCTED DISTURBANCES INDUCED BY RADIO-FREQUENCY FIELDS

Performance criterion: A

4.10.2. TEST CONFIGURATION

4.10.3. TEST PROCEDURE

AC power input lines:

—EUT is placed on an insulating support of 0.1m high above a ground reference plane. It must be 0.3m away the CDN (coupling and decoupling network) of which the bottom is made of metallic material and placed directly on the ground plane. Cables between CDN and EUT are as short as possible, and their height above the ground reference plane shall be between 30 and 50 mm (where possible). The disturbance signal amplified by amplifier is injected to EUT through CDN.

4.10.4. CLIMATIC CONDITIONS

ambient temperature : 23 ℃

relative humidity: 44%

atmospheric pressure: 950 mbar

Level Field Strength V

1. 1

2. 3

3. 10

X Special

EUT

ATTENUATER

SIGNAL GENERATER

AMPLIFIER

R.G..P

CDN

Page 33: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 33 of 44

4.10.5. TEST RESULTS

Results of Final Tests (Mode 1)

Frequency Range: 0.15MHz~80MHz Frequency Step: 1% Dwell time: 1 Sec.

80% A.M., 1 kHz Sine wave (Field Strength: 3 V/m)

Coupling type: CDN / RF Current Probe/ EM CLAMP

Range (MHz) Field Injected Position Criterion Result (Pass/Fail)

0.15-80 3V AC Main A Pass

Remarks: During the test no deviation was detected to the selected operation mode(s).

Page 34: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 34 of 44

4.11. Magnetic Field Immunity

The test is not applicable to the EUT.

4.12. Voltage Dips and Interruptions

4.12.1. TEST LEVELS OF VOLTAGE DIPS AND INTERRUPTIONS

Test Level (%Ut) Voltage Dip And Short

Interruptions (%Ut) Performance Criterion Duration (In Period)

0 100 B 0.5

70 30 C 10

4.12.2. TEST CONFIGURATION

4.12.3. TEST PROCEDURE

EUT is connected to the simulator according to the setup outline of 4.12.1. When conducting the test level of 0.5 period duration, make sure that it shall start at the phase angle of 0°and 180°

4.12.4. CLIMATIC CONDITIONS

ambient temperature : 23 ℃

relative humidity: 46%

atmospheric pressure: 957 mbar

Dips/Interruption and Variations

Simulator

Controller Computer

EUT

0.8m

To AC Source

Page 35: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 35 of 44

4.12.5. TEST RESULTS

Results of Final Tests (Mode 1)

Interruption at phase angles of 0°, 90°, 180°, 270°in a 10 sec-interval.

Test Level %

UT

Duration

(Periods) Phase angle

No. of drop out

Time between dropout

Performance Criterion

Result

0 0.5 0, 90, 180, 270 3 10s B Pass

70 10 0, 90, 180, 270 3 10s C Pass

Remarks: Test results comply with the requirement of clause4.12.1.

Page 36: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 36 of 44

5 . T e s t S e t - u p P h o t o s o f t h e E U T

Radiated Emission (30MHz-1GHz)

Radiated Emissione (Above 1GHz)

Conducted Emission (AC MAIN)

Page 37: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 37 of 44

Electrostatic Discharge

RF Electromagnetic Field

Surges & Fast Transients &Voltage Dips and Interruptions(AC MAIN)

Page 38: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 38 of 44

RF Common Mode 0,15 MHz to 80 MHz(AC MAIN)

Page 39: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 39 of 44

6 . E x t e r n a l a n d I n t e r n a l P h o t o s o f t h e E U T

Page 40: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 40 of 44

Page 41: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 41 of 44

Page 42: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 42 of 44

Page 43: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 43 of 44

Page 44: EMC TRF Template - sc04.alicdn.com

Report No.: HK1905231131-1ER Page 44 of 44

.......................End of Report..........................