emc - test report€¦ · 31/03/2020  · so the item isn’t applicable to the products (en...

49
Report Number: 68.760.17.236.01 Page 1 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA EMC - TEST REPORT Report Number : 68.760.17.236.01 Date of Issue: 24 March 2017 Model : MSA-CxxxxIS12.0-18Q-zz (xxxx = 0100-1500 stands for rated output current range 0.1-1.5A. zz = AT, AU, BE, CA, CH, CN, CZ, DE, DK, FI, FR, GB, GR, HU, IT, JP, KR, NL, NO, PL, SE, SI, SK, US, IN, AG, BR, SA, MX stands for plug type. AT stands for Austria plug, AU stands for Australia plug, BE stands for Belgium plug, CA stands for Canada plug, CH stands for Switzerland plug, CN stands for China plug, CZ stands for Czech Republic plug, DE stands for European plug, DK stands for Denmark plug, FI stands for Finland plug, FR stands for France plug, GB stands for United Kingdom plug, GR stands for Greece plug, HU stands for Hungary plug, IT stands for Italy plug, JP stands for Japan plug, KR stands for Korea plug, NL stands for The Netherlands plug, NO stands for Norway plug, PL stands for Poland plug, SE stands for Sweden plug, SI stands for Slovenia plug, SK stands for Slovakia plug, US stands for United States of America plug, IN stands for Indian plug, AG stands for Argentina plug, BR stands for Brazil plug, SA stands for South Africa plug, MX stands for Mexico plug.) Product Type : AC/DC ADAPTOR Applicant : Moso Power Supply Technology Co., Ltd. Address : Sangtai Industrial Park, Guanwai Xiaobaimang Songbai Road, Nanshan District, 518108 Shenzhen, Guangdong, PEOPLE'S REPUBLIC OF CHINA Production Facility1 Moso Power Supply Technology Co., Ltd. Sangtai Industrial Park, Guanwai Xiaobaimang Songbai Road, Nanshan District, 518108 Shenzhen, Guangdong, PEOPLE'S REPUBLIC OF CHINA Production Facility2 Huizhou MOSO Energy Technology Co., Ltd. Hongda International Industrial City, Luoyang Town, Boluo County, 516100 Huizhou City, Guangdong, PEOPLE'S REPUBLIC OF CHINA

Upload: others

Post on 16-Oct-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 1 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

EMC - TEST REPORT

Report Number : 68.760.17.236.01 Date of Issue: 24 March 2017

Model : MSA-CxxxxIS12.0-18Q-zz (xxxx = 0100-1500 stands for rated

output current range 0.1-1.5A. zz = AT, AU, BE, CA, CH, CN, CZ, DE, DK, FI, FR, GB, GR, HU, IT, JP, KR, NL, NO, PL, SE, SI, SK, US, IN, AG, BR, SA, MX stands for plug type. AT stands for Austria plug, AU stands for Australia plug, BE stands for Belgium plug, CA stands for Canada plug, CH stands for Switzerland plug, CN stands for China plug, CZ stands for Czech Republic plug, DE stands for European plug, DK stands for Denmark plug, FI stands for Finland plug, FR stands for France plug, GB stands for United Kingdom plug, GR stands for Greece plug, HU stands for Hungary plug, IT stands for Italy plug, JP stands for Japan plug, KR stands for Korea plug, NL stands for The Netherlands plug, NO stands for Norway plug, PL stands for Poland plug, SE stands for Sweden plug, SI stands for Slovenia plug, SK stands for Slovakia plug, US stands for United States of America plug, IN stands for Indian plug, AG stands for Argentina plug, BR stands for Brazil plug, SA stands for South Africa plug, MX stands for Mexico plug.)

Product Type : AC/DC ADAPTOR

Applicant : Moso Power Supply Technology Co., Ltd.

Address : Sangtai Industrial Park, Guanwai Xiaobaimang Songbai Road,

Nanshan District, 518108 Shenzhen, Guangdong,

PEOPLE'S REPUBLIC OF CHINA

Production Facility1

Moso Power Supply Technology Co., Ltd.

Sangtai Industrial Park, Guanwai Xiaobaimang Songbai Road,

Nanshan District, 518108 Shenzhen, Guangdong,

PEOPLE'S REPUBLIC OF CHINA

Production Facility2

Huizhou MOSO Energy Technology Co., Ltd.

Hongda International Industrial City, Luoyang Town, Boluo County,

516100 Huizhou City, Guangdong,

PEOPLE'S REPUBLIC OF CHINA

Page 2: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 2 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Test Result : Positive Negative Total pages including Appendices

:

49

TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch is a subcontractor to TÜV SÜD Product Service GmbH according to the principles outlined in ISO 17025. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch reports apply only to the specific samples tested under stated test conditions. Construction of the actual test samples has been documented. It is the manufacturer's responsibility to assure that additional production units of this model are manufactured with identical electrical and mechanical components. The manufacturer/importer is responsible to the Competent Authorities in Europe for any modifications made to the production units which result in non-compliance to the relevant regulations. TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch shall have no liability for any deductions, inferences or generalizations drawn by the client or others from TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch issued reports.

This report is the confidential property of the client. As a mutual protection to our clients, the public and ourselves, extracts from the test report shall not be reproduced except in full without our written approval.

Page 3: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 3 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

1 Table of Contents 1 Table of Contents……………………………………………………………………..…….. 3 2 Details about the Test Laboratory………………………………………………………… 4 3 Description of the Equipment Under Test………...……………………………………… 5 4 Summary of Test Standards…………………...…………………………………………... 6 5 Summary of Test Results….…………………...………………………………………….. 7 6 General Remarks……………………………………………………………………………. 10 7 Emission Test Results……………………………………………………………………… 11

7.1 Radiated Emission Test…………………………………………………………….. 11 7.2 Conducted Emission Test…………………………………………………….…….. 16 7.3 Harmonics Test………………………………………………………………….…… 21 7.4 Flicker Test………………………………………………………………………........ 25

8 Performance Criteria..……………………………………………………………………… 27

9 Immunity Test Results……………………………………………………………………… 28 9.1 Electrostatic Discharge Test………………………………………………………... 28 9.2 Radiated Immunity Test………………………………………………………….….. 31 9.3 Electrical Fast Transients Test……………………………………………………... 33 9.4 Surges Test…………………………………………………………………………… 35 9.5 Conducted Immunity Test……………………………………………………….….. 37 9.6 Voltage Dips, Voltage Variations and Short Interruptions Test………………… 39

10 Appendix A…………………………………………………………………………………… 41 Photographs of Test Set-up 11 Appendix B…………………………………………………………………………………… 46 Photographs of EUT

Page 4: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 4 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

2 Details about the Test Laboratory Details about the Test Laboratory Company name: TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA Telephone: 86 755 8828 6998 Fax: 86 755 8828 5299

Page 5: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 5 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

3 Description of the Equipment Under Test Description of the Equipment Under Test Product: AC/DC ADAPTOR Model no.: MSA-C1500IS12.0-18Q-DE Serial number: NIL Options and accessories: Slide rheostat Ratings: Input: 100-240VAC or 200-240VAC, 50/60Hz, 0.6 max. output: 12.0VDC, 1.5A Description of the EUT: Class II Remark: MSA-CxxxxIS12.0-18Q-zz Input: 100-240VAC or 200-240VAC, 50/60Hz, 0.6A max. output: 12.0VDC, 0.1-1.5A

Page 6: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 6 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

4 Summary of Test Standards

Test Standards

EN 55032:2015 Electromagnetic compatibility of multimedia equipment — Emission requirements

EN 55020:2007 +A11:2011

Sound and television broadcast receivers and associated equipment — Immunity characteristics — Limits and methods of measurement

EN 55024:2010 +A1:2015

Information technology equipment — Immunity characteristics — Limits and methods of measurement

EN 61000-3-2:2014 Electromagnetic compatibility (EMC) — Part 3-2: Limits — Limits for harmonic current emissions (equipment input current up to and including 16 A per phase)

EN 61000-3-3:2013 Electromagnetic compatibility (EMC) — Part 3-3: Limits — Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection

Page 7: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 7 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

5 Summary of Test Results

Emission Tests

EN 55032:2015

Test Condition Pages Test Result

Class B Pass Fail N/A

Radiated Emission (3m semi-anechoic chamber) 30MHz to 1000MHz

11

Radiated Emission * 1GHz to 6GHz

---

Conducted Emission at AC mains ports 150kHz to 30MHz

16

Conducted Differential Voltage Emissions Test at the antenna terminals 30MHz to 1000MHz **

---

EN 61000-3-2:2014

Harmonic Class A

21

EN 61000-3-3:2013

Flicker 25

Remark: “*” Due to the highest frequency of the internal sources of the EUT is less than 108MHz, the measurement only is made up to 1GHz. Remark: “**” only applicable to TV broadcast receiver tuner ports, RF modulator output ports and FM broadcast receiver tuner ports.

Page 8: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 8 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Summary of Test Results

Immunity Tests

EN 55024:2010+A1:2015

Test Condition Pages Test Result

Pass Fail N/A

Electrostatic Discharge (IEC 61000-4-2) ±4kV, ±8KV

28

Radiated Immunity (IEC 61000-4-3) 80MHz to 1000MHz 3V/m (rms)

31

Electrical Fast Transient (IEC 61000-4-4) ±1.0 KV

33

Surge (IEC 61000-4-5) ±1.0 KV

35

Conducted Immunity (IEC 61000-4-6) 150KHz to 80MHz 3Vrms

37

Voltage Dips and Interruption (IEC 61000-4-11) 0%, 70%, 0% of UT

39

Power Frequency Magnetic Field (IEC 61000-4-8) * 50Hz, 60Hz 1A/m

---

EN55020:2007+A11:2011

Test Condition Pages Test Result

Pass Fail N/A

Electrostatic Discharge (IEC 61000-4-2) ±4kV ±8KV

28

Electrical Fast Transient (IEC 61000-4-4) ±1 KV

33

Immunity Against Input Interference S1

---

Immunity Against RFI Voltages S2a

---

Immunity Against RFI Current S2b

---

Ambient Electromagnetic Fields Immunity S3 AM modulated carrier, 0.15MHz to 150MHz1 kHz, at 80 % depth

---

Screening Effectiveness S4

---

RF e.m. field Keyed Carrier S5 (IEC 61000-4-3) 900 MHz, 3 V/m, duty cycle 1/8, 217 Hz repetition frequency

---

RF e.m. Field AM Modulated Carrier (IEC 61000-4-3) 790MHz–862MHz: 3V/m AM:1KHz, 80% depth except the tuned channel ±0.5MHz 1V/m: 1KHz, 80% depth

---

Remark: *: The test only applies to apparatus containing device susceptible to magnetic fields, so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10).

Page 9: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 9 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Summary of Test Results

System Measurement Uncertainty

Test Items Extended Uncertainty

Uncertainty for Radiated Emission in 3m chamber 30MHz-1000MHz

Horizontal: 4.99dB; Vertical: 4.97dB;

Uncertainty for Conducted Emission 150kHz-30MHz (for test using AMN ENV216 or ENV4200)

3.46dB

Uncertainty for Harmonic test 3.26%

Uncertainty for Flicker test 4.76%

Uncertainty for RS test 21%, K=2

Uncertainty for CS test 29%, K=2

Uncertainty for ESD test The immunity measurement system uncertainty is within standard requirement and is based on a standard uncertainty multiplied by a coverage factor k=2, providing a level of confidence of approximately 95%.

Uncertainty for EFT test

Uncertainty for Surges test

Uncertainty for Voltage Dips, Voltage Variations and Short Interruptions Test

Page 10: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49
Page 11: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 11 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

7 Emission Test Results 7.1 Radiated Emission Test 30MHz – 1000MHz

Model No. : MSA-C1500IS12.0-18Q-DE Test requirement : EN 55032 Operating mode : Full Load Tested on : Horizontal Comment : AC 230V/50Hz Date of test : 09 March 2017 Temperature (°C): 23.9 Relative Humidity (%): 58.7 Atmospheric Pressure(mbar) : 1015

Critical_Freqs Frequency

(MHz) MaxPeak (dB¦ÌV/m)

Limit (dB¦ÌV/m)

Margin (dB)

Height (cm)

Pol Azimuth (deg)

50.794375 19.27 40.00 20.73 100.0 H 245.0

68.800000 20.71 40.00 19.29 200.0 H 311.0

97.596875 20.58 40.00 19.42 200.0 H 266.0

140.216250 20.97 40.00 19.03 200.0 H 302.0

181.744375 21.66 40.00 18.34 200.0 H 266.0

985.268125 33.12 47.00 13.88 200.0 H 1.0

Final_Result Frequency

(MHz) QuasiPeak (dB¦ÌV/m)

Limit (dB¦ÌV/m)

Margin (dB)

Height (cm)

Pol Azimuth (deg)

--- --- --- --- --- ---

Leve

l in

dB

μV

/

Page 12: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 12 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Radiated Emission Test 30MHz – 1000MHz

Model No. : MSA-C1500IS12.0-18Q-DE Test requirement : EN 55032 Operating mode : Full Load Tested on : Vertical Comment : AC 230V/50Hz Date of test : 09 March 2017 Temperature (°C): 23.9 Relative Humidity (%): 58.7 Atmospheric Pressure(mbar) : 1015

Critical_Freqs Frequency

(MHz) MaxPeak (dB¦ÌV/m)

Limit (dB¦ÌV/m)

Margin (dB)

Height (cm)

Pol Azimuth (deg)

32.910000 30.56 40.00 9.44 100.0 V 9.0

41.700625 29.97 40.00 10.03 100.0 V 0.0

69.466875 29.44 40.00 10.56 100.0 V 187.0

108.388125 28.04 40.00 11.96 100.0 V 0.0

130.698125 26.76 40.00 13.24 100.0 V 290.0

183.623750 26.92 40.00 13.08 100.0 V 205.0

Final_Result Frequency

(MHz) QuasiPeak (dB¦ÌV/m)

Limit (dB¦ÌV/m)

Margin (dB)

Height (cm)

Pol Azimuth (deg)

32.910000 28.56 40.00 11.44 100.0 V 9.0

Leve

l in

dB

μV

/

Page 13: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 13 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Radiated Emission Test 30MHz – 1000MHz

Model No. : MSA-C1500IS12.0-18Q-DE Test requirement : EN 55032 Operating mode : Full Load Tested on : Horizontal Comment : AC 110V/60Hz Date of test : 09 March 2017 Temperature (°C): 23.9 Relative Humidity (%): 58.7 Atmospheric Pressure(mbar) : 1015

Critical_Freqs Frequency

(MHz) MaxPeak (dB¦ÌV/m)

Limit (dB¦ÌV/m)

Margin (dB)

Height (cm)

Pol Azimuth (deg)

51.279375 18.37 40.00 21.63 100.0 H 150.0

64.495625 21.98 40.00 18.02 100.0 H 305.0

109.600625 18.85 40.00 21.15 100.0 H 177.0

128.151875 22.35 40.00 17.65 100.0 H 314.0

216.846250 25.40 40.00 14.60 100.0 H 269.0

948.832500 33.43 47.00 13.57 100.0 H 168.0

Final_Result Frequency

(MHz) QuasiPeak (dB¦ÌV/m)

Limit (dB¦ÌV/m)

Margin (dB)

Height (cm)

Pol Azimuth (deg)

--- --- --- --- --- ---

Leve

l in

dB

μV

/

Page 14: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 14 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Radiated Emission Test 30MHz – 1000MHz

Model No. : MSA-C1500IS12.0-18Q-DE Test requirement : EN 55032 Operating mode : Full Load Tested on : Vertical Comment : AC 110V/60Hz Date of test : 09 March 2017 Temperature (°C): 23.9 Relative Humidity (%): 58.7 Atmospheric Pressure(mbar) : 1015

Critical_Freqs Frequency

(MHz) MaxPeak (dB¦ÌV/m)

Limit (dB¦ÌV/m)

Margin (dB)

Height (cm)

Pol Azimuth (deg)

33.758750 30.16 40.00 9.84 100.0 V 311.0

46.550625 27.13 40.00 12.87 100.0 V 91.0

64.495625 28.37 40.00 11.63 100.0 V 192.0

97.172500 28.80 40.00 11.20 100.0 V 1.0

122.150000 24.84 40.00 15.16 100.0 V 137.0

881.902500 35.81 47.00 11.19 100.0 V 0.0

Final_Result Frequency

(MHz) QuasiPeak (dB¦ÌV/m)

Limit (dB¦ÌV/m)

Margin (dB)

Height (cm)

Pol Azimuth (deg)

33.758750 28.16 40.00 11.84 100.0 V 311.0

Leve

l in

dB

μV

/

Page 15: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 15 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Test Equipment List Radiated Emission Test

DESCRIPTION MANUFACTURER MODEL NO. SERIAL NO. CAL. DUE DATE

EMI Test Receiver Rohde & Schwarz ESR 26 101269 2017-7-15

Trilog Super Broadband Test Antenna

Schwarzbeck VULB 9163 707 2017-8-3

Horn Antenna Rohde & Schwarz HF907 102294 2017-7-15

Pre-amplifier Rohde & Schwarz SCU 18 102230 2017-7-15

Signal Generator Rohde & Schwarz SMY01 839369/005 2017-7-15

Attenuator Agilent 8491A MY39264334 2017-8-10

3m Semi-anechoic chamber TDK 9X6X6 ---- 2019-5-29

Test software Rohde & Schwarz EMC32 Version 9.15.00 N/A

Page 16: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 16 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

7.2 Conducted Emission Test 150kHz – 30MHz

Model No. : MSA-C1500IS12.0-18Q-DE Test requirement : EN 55032 Operating mode : Full Load Tested on : Power Line, Live Comment : AC 230V/50Hz Date of test : 10 March 2017 Temperature (°C): 23.6 Relative Humidity (%): 55.6 Atmospheric Pressure(mbar) : 1018

Critical_Freqs Frequency

(MHz) MaxPeak (dBµV)

Average (dBµV)

Limit (dBµV)

Margin (dB)

Line Corr. (dB)

0.186000 53.75 --- 64.21 10.46 L1 9.7

0.242000 45.55 --- 62.03 16.48 L1 9.7

0.382000 --- 42.34 48.24 5.89 L1 9.7

1.350000 41.41 --- 56.00 14.59 L1 9.7

1.894000 44.99 --- 56.00 11.01 L1 9.7

3.870000 44.11 --- 56.00 11.89 L1 9.8

Final_Result Frequency

(MHz) QuasiPeak

(dBµV) Average (dBµV)

Limit (dBµV)

Margin (dB)

Line Corr. (dB)

--- --- --- --- --- ---

Le

ve

l in

dB礦

Page 17: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 17 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Conducted Emission Test 150kHz – 30MHz

Model No. : MSA-C1500IS12.0-18Q-DE Test requirement : EN 55032 Operating mode : Full Load Tested on : Power Line, Neutral Comment : AC 230V/50Hz Date of test : 10 March 2017 Temperature (°C): 23.6 Relative Humidity (%): 55.6 Atmospheric Pressure(mbar) : 1018

Critical_Freqs Frequency

(MHz) MaxPeak (dBµV)

Average (dBµV)

Limit (dBµV)

Margin (dB)

Line Corr. (dB)

0.194000 57.63 --- 63.86 6.23 N 9.6

0.258000 50.43 --- 61.50 11.07 N 9.7

0.390000 44.59 --- 58.06 13.47 N 9.7

0.710000 39.92 --- 56.00 16.08 N 9.7

1.162000 40.44 --- 56.00 15.56 N 9.7

3.570000 39.98 --- 56.00 16.02 N 9.8

Final_Result Frequency

(MHz) QuasiPeak

(dBµV) Average (dBµV)

Limit (dBµV)

Margin (dB)

Line Corr. (dB)

0.189500 --- 41.16 54.06 12.90 N 9.6

0.189500 54.72 --- 64.06 9.34 N 9.6

Le

ve

l in

dB礦

Page 18: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 18 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Conducted Emission Test 150kHz – 30MHz

Model No. : MSA-C1500IS12.0-18Q-DE Test requirement : EN 55032 Operating mode : Full Load Tested on : Power Line, Live Comment : AC 110V/60Hz Date of test : 10 March 2017 Temperature (°C): 23.6 Relative Humidity (%): 55.6 Atmospheric Pressure(mbar) : 1018

Critical_Freqs Frequency

(MHz) MaxPeak (dBµV)

Average (dBµV)

Limit (dBµV)

Margin (dB)

Line Corr. (dB)

0.186000 50.75 --- 64.21 13.46 L1 9.7

0.197500 54.30 --- 63.69 9.40 L1 9.7

0.270000 46.46 --- 61.12 14.66 L1 9.7

2.494000 43.17 --- 56.00 12.83 L1 9.7

11.862000 41.57 --- 60.00 18.43 L1 10.1

15.974000 35.98 --- 60.00 24.02 L1 10.1

Final_Result Frequency

(MHz) QuasiPeak

(dBµV) Average (dBµV)

Limit (dBµV)

Margin (dB)

Line Corr. (dB)

0.197500 --- 38.24 53.72 15.48 L1 9.7

0.197500 49.82 --- 63.72 13.90 L1 9.7

Le

ve

l in

dB礦

Page 19: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 19 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Conducted Emission Test 150kHz – 30MHz

Model No. : MSA-C1500IS12.0-18Q-DE Test requirement : EN 55032 Operating mode : Full Load Tested on : Power Line, Neutral Comment : AC 110V/60Hz Date of test : 10 March 2017 Temperature (°C): 23.6 Relative Humidity (%): 55.6 Atmospheric Pressure(mbar) : 1018

Critical_Freqs Frequency

(MHz) MaxPeak (dBµV)

Average (dBµV)

Limit (dBµV)

Margin (dB)

Line Corr. (dB)

0.198000 50.21 --- 63.69 13.48 N 9.6

0.398000 43.32 --- 57.90 14.57 N 9.7

1.662000 42.89 --- 56.00 13.11 N 9.7

2.030000 44.23 --- 56.00 11.77 N 9.7

6.878000 37.88 --- 60.00 22.12 N 9.9

11.894000 41.80 --- 60.00 18.20 N 10.1

Final_Result Frequency

(MHz) QuasiPeak

(dBµV) Average (dBµV)

Limit (dBµV)

Margin (dB)

Line Corr. (dB)

--- --- --- --- --- ---

Le

ve

l in

dB礦

Page 20: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 20 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Test Equipment List Conducted Emission Test

DESCRIPTION MANUFACTURER MODEL NO. SERIAL NO. CAL. DUE DATE

EMI Test Receiver Rohde & Schwarz ESR 3 101782 2017-7-15

LISN Rohde & Schwarz ENV4200 100249 2017-7-15

LISN Rohde & Schwarz ENV432 101318 2017-12-18

LISN Rohde & Schwarz ENV216 100326 2017-7-15

ISN Rohde & Schwarz ENY81 100177 2017-7-15

ISN Rohde & Schwarz ENY81-CA6 101664 2017-7-15

High Voltage Probe Rohde & Schwarz TK9420(VT94

20) 9420-584 2017-7-15

RF Current Probe Rohde & Schwarz EZ-17 100816 2017-7-15 Attenuator Shanghai Huaxiang TS2-26-3 080928189 2017-7-17

Test software Rohde & Schwarz EMC32 Version9.15.00 N/A

Page 21: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 21 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

7.3 Harmonic Test Temperature (°C): 24.2 Relative Humidity (%): 55.3 Atmospheric Pressure(mbar) : 1017

Harmonics – Class-A per Ed. 4.0 (2014)(Run time)

EUT: MSA-C1500IS12.0-18Q-DE Tested by: Tree Test category: Class-A per Ed. 4.0 (2014) (European limits) Test Margin: 100 Test date: 2017/3/9 Start time: 14:57:56 End time: 15:00:48 Test duration (min): 2.5 Data file name: CTSMXL_H-000395.cts_data Comment: Full Load Customer: Moso Power Supply Technology Co., Ltd. Test Result: Pass Source qualification: Normal Current & voltage waveforms

Harmonics and Class A limit line European Limits

Test result: Pass Worst harmonic was #25 with 14.0% of the limit.

- 0 . 8

- 0 . 4

0 . 0

0 . 4

0 . 8

- 3 0 0

- 2 0 0

- 1 0 0

0

1 0 0

2 0 0

3 0 0

Cu

rr

en

t

(A

mp

s)

Vo

lt

ag

e

(V

ol

ts

)

0 . 0

0 . 5

1 . 0

1 . 5

2 . 0

2 . 5

3 . 0

3 . 5

Cu

rr

en

t

RM

S(

Am

ps

)

H a r m o n i c #4 8 1 2 1 6 2 0 2 4 2 8 3 2 3 6 4 0

Page 22: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 22 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Harmonic Test

Current Test Result Summary (Run time)

EUT: MSA-C1500IS12.0-18Q-DE Tested by: Tree Test category: Class-A per Ed. 4.0 (2014) (European limits) Test Margin: 100 Test date: 2017/3/9 Start time: 14:57:56 End time: 15:00:48 Test duration (min): 2.5 Data file name: CTSMXL_H-000395.cts_data Comment: Full Load Customer: Moso Power Supply Technology Co., Ltd. Test Result: Pass Source qualification: Normal THC(A): 0.167 I-THD(%): 181.2 POHC(A): 0.047 POHC Limit(A): 0.251 Highest parameter values during test:

V_RMS (Volts): 229.943 Frequency(Hz): 50.00 I_Peak (Amps): 0.936 I_RMS (Amps): 0.195 I_Fund (Amps): 0.093 Crest Factor: 4.835 Power (Watts): 19.8 Power Factor: 0.445

Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status 2 0.002 1.080 N/A 0.002 1.620 N/A Pass 3 0.083 2.300 3.6 0.086 3.450 2.5 Pass 4 0.001 0.430 N/A 0.001 0.645 N/A Pass 5 0.077 1.140 6.7 0.077 1.710 4.5 Pass 6 0.000 0.300 N/A 0.001 0.450 N/A Pass 7 0.067 0.770 8.8 0.068 1.155 5.9 Pass 8 0.000 0.230 N/A 0.001 0.345 N/A Pass 9 0.057 0.400 14.2 0.058 0.600 9.6 Pass 10 0.000 0.184 N/A 0.001 0.276 N/A Pass 11 0.046 0.330 13.9 0.046 0.495 9.4 Pass 12 0.001 0.153 N/A 0.002 0.230 N/A Pass 13 0.036 0.210 17.0 0.036 0.315 11.5 Pass 14 0.000 0.131 N/A 0.001 0.197 N/A Pass 15 0.028 0.150 18.4 0.028 0.225 12.4 Pass 16 0.000 0.115 N/A 0.001 0.173 N/A Pass 17 0.023 0.132 17.1 0.023 0.198 11.6 Pass 18 0.000 0.102 N/A 0.001 0.153 N/A Pass 19 0.021 0.118 17.3 0.021 0.178 11.9 Pass 20 0.000 0.092 N/A 0.001 0.138 N/A Pass 21 0.020 0.107 18.7 0.021 0.161 12.8 Pass 22 0.000 0.084 N/A 0.001 0.125 N/A Pass 23 0.020 0.098 20.0 0.020 0.147 13.7 Pass 24 0.000 0.077 N/A 0.001 0.115 N/A Pass 25 0.018 0.090 20.4 0.019 0.135 14.0 Pass 26 0.000 0.071 N/A 0.001 0.107 N/A Pass 27 0.017 0.083 19.9 0.017 0.125 13.6 Pass 28 0.000 0.066 N/A 0.000 0.099 N/A Pass 29 0.014 0.078 18.6 0.015 0.116 12.8 Pass 30 0.000 0.061 N/A 0.000 0.092 N/A Pass 31 0.013 0.073 17.3 0.013 0.109 12.0 Pass 32 0.000 0.058 N/A 0.001 0.086 N/A Pass 33 0.011 0.068 16.6 0.012 0.102 11.6 Pass 34 0.000 0.054 N/A 0.001 0.081 N/A Pass 35 0.011 0.064 16.6 0.011 0.096 11.6 Pass 36 0.000 0.051 N/A 0.001 0.077 N/A Pass 37 0.010 0.061 16.9 0.011 0.091 11.8 Pass 38 0.000 0.048 N/A 0.001 0.073 N/A Pass 39 0.010 0.058 16.9 0.010 0.087 11.8 Pass 40 0.000 0.046 N/A 0.001 0.069 N/A Pass

Page 23: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 23 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Harmonic Test

Voltage Source Verification Data (Run time)

EUT: MSA-C1500IS12.0-18Q-DE Tested by: Tree Test category: Class-A per Ed. 4.0 (2014) (European limits) Test Margin: 100 Test date: 2017/3/9 Start time: 14:57:56 End time: 15:00:48 Test duration (min): 2.5 Data file name: CTSMXL_H-000395.cts_data Comment: Full Load Customer: Moso Power Supply Technology Co., Ltd. Test Result: Pass Source qualification: Normal Measured source distortion is within the requirements of the standards Measurements are compliant with IEC/EN61000-3-2 Ed. 4 & IEC/EN61000-4-7 Ed. 2.1 Highest parameter values during test:

Voltage (Vrms): 229.943 Frequency(Hz): 50.00 I_Peak (Amps): 0.936 I_RMS (Amps): 0.195 I_Fund (Amps): 0.093 Crest Factor: 4.835 Power (Watts): 19.8 Power Factor: 0.445

Harm# Harmonics V-rms Limit V-rms % of Limit Status 2 0.116 0.460 25.18 OK 3 0.160 2.069 7.75 OK 4 0.044 0.460 9.64 OK 5 0.064 0.920 6.93 OK 6 0.015 0.460 3.18 OK 7 0.032 0.690 4.64 OK 8 0.019 0.460 4.22 OK 9 0.055 0.460 11.92 OK 10 0.013 0.460 2.89 OK 11 0.036 0.230 15.85 OK 12 0.013 0.230 5.86 OK 13 0.047 0.230 20.41 OK 14 0.012 0.230 5.41 OK 15 0.040 0.230 17.55 OK 16 0.008 0.230 3.62 OK 17 0.030 0.230 13.20 OK 18 0.011 0.230 4.65 OK 19 0.027 0.230 11.60 OK 20 0.019 0.230 8.20 OK 21 0.035 0.230 15.35 OK 22 0.010 0.230 4.41 OK 23 0.032 0.230 13.92 OK 24 0.011 0.230 4.66 OK 25 0.029 0.230 12.82 OK 26 0.008 0.230 3.50 OK 27 0.031 0.230 13.29 OK 28 0.007 0.230 3.26 OK 29 0.025 0.230 10.76 OK 30 0.007 0.230 3.12 OK 31 0.026 0.230 11.17 OK 32 0.008 0.230 3.68 OK 33 0.028 0.230 12.03 OK 34 0.006 0.230 2.61 OK 35 0.020 0.230 8.91 OK 36 0.007 0.230 3.06 OK 37 0.021 0.230 8.99 OK 38 0.008 0.230 3.28 OK 39 0.024 0.230 10.37 OK 40 0.016 0.230 6.86 OK

Page 24: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 24 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Test Equipment List Harmonic Test

DESCRIPTION MANUFACTURER MODEL NO. SERIAL NO. CAL. DUE DATE

Three Phase Harmonic flicker test system

CI MX45-3PI-400-413-

CTSHL-LF-SNK 1424A00547 2017-7-15

Test software Ametek CTSMXL Version 2.9.0 N/A

Test software Ametek CTSMXH Version 2.10.0 N/A

Page 25: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 25 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

7.4 Flicker Test Temperature (°C): 24.2 Relative Humidity (%): 55.3 Atmospheric Pressure(mbar) : 1017

Flicker Test Summary per EN/IEC61000-3-3 Ed. 3.0 (2013) (Run time)

EUT: MSA-C1500IS12.0-18Q-DE Tested by: Tree Test category: All parameters (European limits) Test Margin: 100 Test date: 2017/3/9 Start time: 15:04:49 End time: 15:15:21 Test duration (min): 10 Data file name: CTSMXL_F-000396.cts_data Comment: Full Load Customer: Moso Power Supply Technology Co., Ltd. Test Result: Pass Status: Test Completed Psti and limit line European Limits

Plt and limit line

Parameter values recorded during the test: Vrms at the end of test (Volt): 229.88 Highest dt (%): 0.00 Test limit (%): N/A N/A T-max (mS): 0.0 Test limit (mS): 500.0 Pass Highest dc (%): 0.00 Test limit (%): 3.30 Pass Highest dmax (%): 0.05 Test limit (%): 4.00 Pass Highest Pst (10 min. period): 0.164 Test limit: 1.000 Pass Highest Plt (2 hr. period): 0.072 Test limit: 0.650 Pass

0 . 2 5

0 . 5 0

0 . 7 5

1 . 0 0

Ps

t

15

:1

5:

20

0 . 2 5

0 . 5 0

Pl

t

15

:1

5:

20

Page 26: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 26 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Test Equipment List Flicker Test

DESCRIPTION MANUFACTURER MODEL NO. SERIAL NO. CAL. DUE DATE

Three Phase Harmonic flicker test system

CI MX45-3PI-400-413-

CTSHL-LF-SNK 1424A00547 2017-7-15

Test software Ametek CTSMXL Version 2.9.0 N/A

Test software Ametek CTSMXH Version 2.10.0 N/A

Page 27: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 27 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

8 Performance Criteria EN 55024

A During and after the test the EUT shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed below a minimum performance level specified by the manufacturer when the EUT is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user may reasonably expect from the EUT if used as intended.

B After the test, the EUT shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed, after the application of the phenomena below a performance level specified by the manufacturer, when the EUT is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is allowed. However, no change of operating state or stored data is allowed to persist after the test. If the minimum performance level (or the permissible performance loss) is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user may reasonably expect from the EUT if used as intended.

C During and after testing, a temporary loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of the controls or cycling of the power to the EUT by the user in accordance with the manufacturer’s instructions. Functions, and/or information stored in non-volatile memory, or protected by a battery backup, shall not be lost.

EN 55020

A The equipment shall continue to operate as intended during the test. No change of actual operating state (for example change of channel) is allowed as a result ofthe application of the test. Multifunction equipment shall for each function meet the relevant requirements. Evaluation is carried out for audio and video functions. Evaluation of audio quality Unless otherwise specified in this standard, the criterion of compliance with the requirement is a wanted to unwanted audio signal ratio of ≥40 dB at a wanted audio signal level of 50 mW, or at another audio signal level specified by the manufacturer. If the S/N ratio is less than 43 dB, the performance criterion for audio assessment is the actual S/N ratio minus 3 dB. In this case, at the beginning of the audio quality evaluation the actual S/N ratio is measured and noted in the test report as reference value. For AM sound receivers the criterion is ≥26 dB at 50 mW. For AM and FM car radios and for broadcast receiver cards for computers the criterion is ≥26 dB at 500 mW Evaluation of picture quality In the evaluation of picture interference the wanted test signal produces a standard picture (in the case of video tape equipment on the screen of the test-tv-set) and the unwanted signal produces a degradation of the picture. The degradation may be in a number of forms, such as a superposed pattern, disturbance of synchronization, geometrical distortion, loss of picture contrast, of colour, etc. The criterion of compliance with the requirement is just perceptible degradation by observation of the picture. The screen shall be observed under normal viewing conditions (brightness 15 lx to 20 lx), at a viewing distance of six times the height of the screen. In the case of video tape equipment the test criteria relate to the picture, assessed on a test-tv-set, which is connected to the video output terminal of the equipment.

B The equipment shall continue to operate as intended after the test. No loss of function is allowed after the test when the apparatus is used as intended, but failures which are recovered automatically but which cause temporary delay in processing, are permissible. No change of actual operating state for example change of channel or stored data and settings is allowed as a result of the application of the test. During the test, degradation of performance is allowed.

Page 28: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 28 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

9 Immunity Test Results 9.1 Electrostatic Discharge Test Applicant : Moso Power Supply Technology Co., Ltd.

Project no. : 68.760.17.236.01

Model : MSA-C1500IS12.0-18Q-DE

Description : AC/DC ADAPTOR

Operating Mode : Full Load Table Top Floor Stand

Ambient Temperature (°C) : 24.7 Relative Humidity (%): 58.3 Atmospheric Pressure(mbar): 1015

Test regulation : EN 60601-1-2 EN 50082-2 EN 55020 EN 55024 IEC 1000-4-2 IEC 801-2 EN 61547 IEC 61000-4-2 Indirect discharge : Draw points in the appendix

Contact Number and Polarity Point kV at each voltage level

1: VCP-Front Side ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..10 pos ..10 neg

2: VCP-Right Side ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..10 pos ..10 neg

3: VCP-Rear Side ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..10 pos ..10 neg

4: VCP-Left Side ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..10 pos ..10 neg

5: HCP-Front Side ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..10 pos ..10 neg

6: HCP-Right Side ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..10 pos ..10 neg

7: HCP-Rear Side ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..10 pos ..10 neg

8: HCP-Left Side ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..10 pos ..10 neg

9:______________ ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..10 pos ..10 neg

Remarks: VCP = Vertical Coupling Plane; HCP = Horizontal Coupling Plane.

Result: Complies Does not comply Photo done

Criterion Required : B Criterion Met : A

Date : 13 March 2017 Test Engineer : Adam Yang

Page 29: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 29 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Electrostatic Discharge Test Applicant : Moso Power Supply Technology Co., Ltd.

Project no. : 68.760.17.236.01

Model : MSA-C1500IS12.0-18Q-DE

Description : AC/DC ADAPTOR

Operating Mode : Full Load Table Top Floor Stand

Ambient Temperature (°C) : 24.7 Relative Humidity (%): 58.3 Atmospheric Pressure(mbar): 1015

Test regulation : EN 60601-1-2 EN 50082-2 EN 55020 EN 55024 IEC 1000-4-2 IEC 801-2 EN 61547 IEC 61000-4-2 Indirect discharge : Draw points in the appendix

Contact Air Number and Polarity Point kV kV at each voltage level

1. Each conductive ..2 ..4 ..2 ..4 ..25 pos ..25 neg

Location touchable by hand

..6 ..8 ..8 .. ..10 pos ..10 neg

2. Each nonconductive ..2 ..4 ..2 ..4 ..25 pos ..25 neg

Location touchable by hand

..6 ..8 ..8 .. ..10 pos ..10 neg

3. ..2 ..4 ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..8 .. ..10 pos ..10 neg

4. ..2 ..4 ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..8 .. ..10 pos ..10 neg

5. ..2 ..4 ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..8 .. ..10 pos ..10 neg

6. ..2 ..4 ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..8 .. ..10 pos ..10 neg

7. ..2 ..4 ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..8 .. ..10 pos ..10 neg

8. ..2 ..4 ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..8 .. ..10 pos ..10 neg

9. ..2 ..4 ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..8 .. ..10 pos ..10 neg

10. ..2 ..4 ..2 ..4 ..25 pos ..25 neg

..6 ..8 ..8 .. ..10 pos ..10 neg

Remarks:

Result: Complies Does not comply Photo done

Criterion Required : B Criterion Met : A

Date : 13 March 2017 Test Engineer : Adam Yang

Page 30: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 30 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Test Equipment List Electrostatic Discharge Test

DESCRIPTION MANUFACTURER MODEL NO. SERIAL NO. CAL. DUE DATE

Electrostatic Discharge Simulator

Noiseken ESS-2002 ESS0615075 2017-7-31

Page 31: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 31 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

9.2 Radiated Immunity Test Applicant : Moso Power Supply Technology Co., Ltd.

Project no. : 68.760.17.236.01

Model : MSA-C1500IS12.0-18Q-DE

Description : AC/DC ADAPTOR

Operating Mode : Full Load Table Top Floor Stand

Ambient Temperature (°C) : 23.7 Relative Humidity (%): 54.6 Atmospheric Pressure(mbar) : 1019

Test regulation : EN 61000-6-1 EN 50082-2 EN 55020

EN 55024 IEC 1000-4-3 IEC 801-2

EN 61547 IEC 61000-4-3

Remarks:

Result: Complies Does not comply Photo done

Criterion Required : A Criterion Met : A

Date : 08 March 2017 Test Engineer : Tree Zhan

Page 32: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 32 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Test Equipment List Radiated Immunity Test

DESCRIPTION MANUFACTURER MODEL NO. SERIAL NO. CAL. DUE DATE

Signal Generator Rohde & Schwarz SMB100A 177600 2017-7-15

Power Amplifier Rohde & Schwarz BBA100 101238 2017-7-15

Power Amplifier Rohde & Schwarz BBA150 101671 2017-7-15

Log-Periodic Antenna Rohde & Schwarz HL046E 100160 N/A

Power Meter Rohde & Schwarz NRP2 103497 2017-7-15

Average Power Sensor Rohde & Schwarz NRP-Z91 102538 2017-7-15

Average Power Sensor Rohde & Schwarz NRP-Z91 102539 2017-7-15

Starprobe Laser-Powered Probe

AMPLIFIER RESEARCH

FL7006/KIT 0433720 2017-7-20

Fully Anechoic Chamber

TDK 8X4X4 -- 2019-5-29

Test software Rohde & Schwarz EMC32 Version 9.15.00 N/A

Page 33: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 33 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

9.3 Electrical Fast Transient Test Applicant : Moso Power Supply Technology Co., Ltd.

Project no. : 68.760.17.236.01

Model : MSA-C1500IS12.0-18Q-DE

Description : AC/DC ADAPTOR

Operating Mode : Full Load Table Top Floor Stand

Ambient Temperature (°C) : 24.6 Relative Humidity (%): 58.1 Atmospheric Pressure(mbar) : 1015

Test regulation : EN 60601-1-2 EN 50082-2 EN 55020

EN 55024 IEC 1000-4-4 IEC 801-2

EN 61547 IEC 61000-4-4

Coupling: Network Clamp

Repetition Rate: 5 kHz ___ kHz Coupling Time: 1 minute 2 minutes

Point Test Voltage (kV) Criteria

L1 (pos) to Ref Gnd ..0.5 ..1 ..2 ..4 ..__ ..A ..B ..C

L1 (neg) to Ref Gnd ..0.5 ..1 ..2 ..4 ..__ ..A ..B ..C

N (pos) to Ref Gnd ..0.5 ..1 ..2 ..4 ..__ ..A ..B ..C

N (neg) to Ref Gnd ..0.5 ..1 ..2 ..4 ..__ ..A ..B ..C

PE (pos) to Ref Gnd ..0.5 ..1 ..2 ..4 ..__ ..A ..B ..C

PE (neg) to Ref Gnd ..0.5 ..1 ..2 ..4 ..__ ..A ..B ..C

L1+N (pos) to Ref Gnd ..0.5 ..1 ..2 ..4 ..__ ..A ..B ..C

L1+N (neg) to Ref Gnd ..0.5 ..1 ..2 ..4 ..__ ..A ..B ..C

L1+N+PE (pos) to Ref Gnd ..0.5 ..1 ..2 ..4 ..__ ..A ..B ..C

L1+N+PE (neg) to Ref Gnd ..0.5 ..1 ..2 ..4 ..__ ..A ..B ..C

Remarks: Temporary degradation was found during test, but can recover automatically after test.

Result: Complies Does not comply Photo done

Criterion Required : B Criterion Met : B

Date : 13 March 2017 Test Engineer : Adam Yang

Page 34: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 34 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Test Equipment List Electrical Fast Transients Test

DESCRIPTION MANUFACTURER MODEL NO. SERIAL NO. CAL. DUE DATE

Immunity simulator EMTEST UCS 500N7 P1313116005 2017-7-15

7kV Coupling network 3-phase EMTEST CNI 503B5 P1425134991 2017-7-15

Capacitive Coupling Clamp EMTEST HFK P1426135389 2017-7-15

Test software EMTEST iec.control Version 5.3.1 N/A

Page 35: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 35 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

9.4 Surges Test Applicant : Moso Power Supply Technology Co., Ltd.

Project no. : 68.760.17.236.01

Model : MSA-C1500IS12.0-18Q-DE

Description : AC/DC ADAPTOR

Operating Mode : Full Load Table Top Floor Stand

Ambient Temperature (°C) : 21.8 Relative Humidity (%): 57.1 Atmospheric Pressure(mbar) : 1015

Test regulation : EN 60601-1-2 EN 50082-2 EN 55020

EN 55024 IEC 1000-4-5 IEC 801-2

EN 61547 IEC 61000-4-5

TEST LEVEL PHASE # OF SURGE EUT COMPLIES?

kV ANGLE SURGES L/PE N/PE L/N YES NO Remarks

(+) (-)

1 0° 5 Y 1 0° 5 Y 1 90° 5 Y 1 90° 5 Y 1 180° 5 Y 1 180° 5 Y 1 270° 5 Y 1 270° 5 Y

Remarks:

Result: Complies Does not comply Photo done

Criterion Required : B Criterion Met : A

Date : 13 March 2017 Test Engineer : Adam Yang

Page 36: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 36 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Test Equipment List Surges Test

DESCRIPTION MANUFACTURER MODEL NO. SERIAL NO. CAL. DUE DATE

Immunity simulator EMTEST UCS 500N7 P1313116005 2017-7-15

7kV Coupling network 3-phase

EMTEST CNI 503B5 P1425134991 2017-7-15

Telecom Surge Module EMTEST Tsurge 7 P1420134206 2017-7-15

4kV coupling/decoupling network

EMTEST CNV 504 N1 P1420134192 2017-7-24

4kV CDN for 8 telecom lines

EMTEST CNV 508 S1 P1431137565 2017-7-15

Test software EMTEST iec.control Version 5.3.1 N/A

Page 37: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 37 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

9.5 Conducted Immunity Test Applicant : Moso Power Supply Technology Co., Ltd.

Project no. : 68.760.17.236.01

Model : MSA-C1500IS12.0-18Q-DE

Description : AC/DC ADAPTOR

Operating Mode : Full Load Table Top Floor Stand

Ambient Temperature (°C) : 24.2 Relative Humidity (%): 58.7 Atmospheric Pressure(mbar) : 1015

Test regulation : EN 60601-1-2 EN 50082-2 EN 55020

EN 55024 IEC 1000-4-6 IEC 801-2

EN 61547 IEC 61000-4-6

Remarks:

Result: Complies Does not comply Photo done

Criterion Required : A Criterion Met : A

Date : 13 March 2017 Test Engineer : Adam Yang

Page 38: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 38 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Test Equipment List Conducted Immunity Test

DESCRIPTION MANUFACTURER MODEL NO. SERIAL NO. CAL. DUE DATE

Continuous Wave Simulator

EMTEST CWS 500N1 P1420134224 2017-7-15

Attenuator EMTEST ATT6/80 P1402129090 2017-7-15

CDN EMTEST CDN-M2/M3 P1420134163 2017-7-15

CDN EMTEST CDN-M4 P1346125919 2017-7-15

Electromagnetic Injection Clamp

EMTEST EM101 P1411132453 2017-7-15

Test software EMTEST icd.control Version 5.2.9 N/A

Page 39: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 39 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

9.6 Voltage Dips, Voltage Variations and Short Interruptions Test Applicant : Moso Power Supply Technology Co., Ltd.

Project no. : 68.760.17.236.01

Model : MSA-C1500IS12.0-18Q-DE

Description : AC/DC ADAPTOR Serial No. : NIL

Operating Mode : Full load Table Top Floor Stand

Ambient Temperature (°C) : 24.2 Relative Humidity (%): 57.6 Atmospheric Pressure(mbar) : 1015

Test regulation : EN 61000-6-1 EN 50082-2 EN 55014-2

EN 55024 IEC 1000-4-11 IEC 801-2

EN 61547 IEC 61000-4-11 UT : 100V/240V AC

Test Level Dips & Interruptions Duration Criterion Criterion %U %U (in period) / s meet T

70 30 25 / 500 ms C A

0 100 0.5 / 10 ms B A

0 100 250 / 5 s C B

Remarks: The EuT shut down when 100%(5s) voltage interruption was applied during test, but it

can be restored to normal operation automatically after test.

Result: Complies Does not comply Photo done

Date : 13 March 2017 Test Engineer : Adam Yang

Page 40: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 40 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Test Equipment List Voltage Dips and Interruptions Test

DESCRIPTION MANUFACTURER MODEL NO. SERIAL NO. CAL. DUE DATE

Immunity simulator EMTEST UCS 500N7 P1313116005 2017-7-15

Motorized Variac EMTEST MV2616 P1401128623 2017-7-15

Switch-Box for phase by phase

EMTEST PFLS 32N1 P1251107106 N/A

Test software EMTEST iec.control Version 5.3.1 N/A

Page 41: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 41 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

10 Appendix A

Radiated Emission Test

Conducted Emission Test

Page 42: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 42 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Appendix A

Harmonics Test

Flicker Test

Page 43: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 43 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Appendix A

Electrostatic Discharge Test

Radiated Immunity Test

Page 44: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 44 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Appendix A

Electrical Fast Transients Test

Surges Test

Page 45: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 45 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Appendix A

Conducted Immunity Test

Voltage Dips and Short Interruptions Test

Page 46: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 46 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

11 Appendix B Details of: Overview 1

Details of: Overview 2

Page 47: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 47 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Appendix B Details of: Internal view

Details of: PCB view 1 (with secondary heat sink)

Page 48: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 48 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Appendix B Details of: PCB view 2 (with secondary heat sink)

Details of: PCB view 3 (without secondary heat sink)

Page 49: EMC - TEST REPORT€¦ · 31/03/2020  · so the item isn’t applicable to the products (EN 55024:2010+A1:2015 clause 10). Report Number: 68.760.17.236.01 Page 9 of 49

Report Number: 68.760.17.236.01 Page 49 of 49 TÜV SÜD Certification and Testing (China) Co., Ltd. Shenzhen Branch

Building 12&13, Zhiheng Wisdomland Business Park, Nantou Checkpoint Road 2, Nanshan District, 518052 Shenzhen, CHINA

Appendix B Details of: PCB view 4 (without secondary heat sink)

Details of: Plug pin and input lead wire connection view