Email Message related to Service Request
Number: 1-170397178
Customer Name: Jet Airways
Owner: David Onstot Message Sent: 12-Mar-2006 10:18:33
((GMT+05:30) Chennai, Kolkata, Mumbai, New Delhi)
Message Number: 1-170397178-2 Communication Status: Done
Communication Type:
From: [email protected] Due: 12-Mar-2006 10:19:38
Field Base:
To: <[email protected]>
Cc:
Airplanes:
Registry Number Variable Number Serial Number Hours Cycles
Inquiry Type:
Subject: Fw: VT-JAS RH. Elev. tab. AOG AOG AOG
Body:
Dear Sir,
Lightening strike observed on Rh. elevator tab on our aircraft
VT-JAS , Line no- 2963, Aircraft Serial no.-29033, VAR No. PW422.
Due to lightening strike ,we are replacing RH. elevator tab [ part no.
65C26384-28A ].
As per the maintenance manual we have to add balance weight Part no.
69-53223-2 ,IPC ref. 27-21-11-02 item no. 419 , which is nil in our
stock. .
We have balance weight part no. 69-53223-1 available in stores.
Please confirm whether we can install balance weight part no. 69-53223-1
in place of balance weight part no. 69-53223-2.
Reply requested on AOG AOG AOG basis.
Thanks & regards,
Vijoy Kumar
Manager- Maintrol
-------------------------------------------------------------------------------------------------- Page 1 of ----13
-------------------------------------------------------------------------------------------------- Page 2 of ----13
Email Message related to Service Request
Number: 1-170397178
Customer Name: Jet Airways
Owner: David Onstot Message Sent: 12-Mar-2006 11:02:52
((GMT+05:30) Chennai, Kolkata, Mumbai, New Delhi)
Message Number: 1-170397178-3 Communication Status: Done
Communication Type:
From: [email protected] Due: 12-Mar-2006 11:03:40
Field Base:
To: <[email protected]>
Airplanes:
Registry Number Variable Number Serial Number Hours Cycles
Inquiry Type:
Subject: revised Fw: VT-JAS RH. Elev. tab. AOG AOG AOG
Body:
Please note the change in IPC ref.
Regards,
Nitin J.
MCC
----- Forwarded by Maintrol/Bomairport/Jetairways on 12/03/2006 11:01 AM
-----
Maintrol/Bomairpo
rt/Jetairways
To
12/03/2006 09:18 BOEING
AM cc
Subject
Fw: VT-JAS RH. Elev. tab. AOG AOG
AOG
-------------------------------------------------------------------------------------------------- Page 3 of ----13
----- Forwarded by Maintrol/Bomairport/Jetairways on 12/03/2006 09:16 -----
Defect Analysis
Cell/Bomairport/J
etairways To
12/03/2006 08:49 cc
Maintrol/Bomairport/Jetairways@Jeta
irways,
Subject
VT-JAS RH. Elev. tab. AOG AOG AOG
Dear Sir,
Lightening strike observed on Rh. elevator tab on our aircraft
VT-JAS , Line no- 2963, Aircraft Serial no.-29033, VAR No. PW422.
Due to lightening strike ,we are replacing RH. elevator tab [ part no.
65C26384-28A ].
As per the maintenance manual we have to add balance weight Part no.
69-53223-2 ,IPC ref. 27-31-11-02 item no. 419 , which is nil in our
stock. .
We have balance weight part no. 69-53223-1 available in stores.
Please confirm whether we can install balance weight part no. 69-53223-1 in
place of balance weight part no. 69-53223-2.
Reply requested on AOG AOG AOG basis.
-------------------------------------------------------------------------------------------------- Page 4 of ----13
Thanks & regards,
Vijoy Kumar
Manager- Maintrol
-------------------------------------------------------------------------------------------------- Page 5 of ----13
Email Message related to Service Request
Number: 1-170397178
Customer Name: Jet Airways
Owner: BOC Queue Message Sent: 12-Mar-2006 12:06:11
((GMT+05:30) Chennai, Kolkata, Mumbai, New Delhi)
Message Number: 1-170397178-1 Communication Status: Done
Communication Type: Customer Acknowledgement
From: BOECOM Notify Due:
Field Base: BFSBOM-Mumbai-India
To:
Cc:
Airplanes:
Registry Number Variable Number Serial Number Hours Cycles
Inquiry Type:
Subject: *** AOG AOG AOG*** P/N 69-53223-2 ELEVATOR TAB BALANCE WEIGHTS
INTERCHANGEABILITY
Body:
FROM: THE BOEING COMPANY
TO: JPL [MESSAGE NUMBER:1-170397178-1] 11-Mar-2006 22:36:10 US PACIFIC TIME
Customer Acknowledgement
Your message has been received. If a response has been requested, it will be provided on or before
3/12/2006.
This message is sent to the following:
Maint. Defect Analysis Cell, at Jet Airways
Mumbai Maintrol, at Jet Airways
SERVICE REQUEST ID: 1-170397178
PRIORITY: AOG
ACCOUNT: Jet Airways (JPL)
DUE DATE: 3/12/2006
PROJECT: BFSBOM-Mumbai-India
-------------------------------------------------------------------------------------------------- Page 6 of ----13
PRODUCT TYPE: Airplane
PRODUCT LINE: 737
PRODUCT: 737-400
ATA: 5160-40
PART NUMBER :
AIRPLANE (VARIABLE/SERIAL): PW422/29033 REGISTRY: VT-JAS
HOURS/CYCLES:/
SUBJECT: *** AOG AOG AOG*** P/N 69-53223-2 ELEVATOR TAB BALANCE WEIGHTS
INTERCHANGEABILITY
REFERENCES:
/A/ P/N 69-53223-2 Balance Weight
/B/ P/N 69-53223-1 Balance Weight
DESCRIPTION:
The following message sent to Sue Fullington.
Jet Airways (JPL) datum airplane is AOG in Mumbai due to lightening strike.
JPL wants to carry out RH Elevator tab balance check. JPL has ref /A/ balance weight installed on the
airplane. However they have ref /B/ balance weight in stock.
Per Spares Engineering and Provisioning on myboeingfleet.com, ref /B/ balance weight is not interchangeable
with ref /A/ balance weight.
JPL is unable to procure ref /A/ balance weight and wants to know if they can fabricate or modify ref /B/
balance weight and install on the airplane.
Desired Action:
1) Please advise JPL if they can install ref /B/ balance weight on the datum airplane with any modification.
JPL would highly appreciate a response within the next 2 hours.
S. Rajeshirke/H. Levanen
Boeing Field Service Mumbai
BFSBOM
When present, attachment names are listed below this line:
-------------------------------------------------------------------------------------------------- Page 7 of ----13
BOEING PROPRIETARY
This message and any attachments to it contain or may contain Boeing proprietary material which is protected
at law and/or per the terms of existing agreements with Boeing. Proprietary material may be used by the
recipient only as permitted under the terms of any such prior agreement with Boeing. This message is
intended only for the named recipients. If you are not an intended recipient, you are hereby notified that any
further review, copying, use or dissemination of this message is strictly prohibited. If you have received this
message in error, delete it from your computer and/or other storage medium and notify the sender
immediately.
-------------------------------------------------------------------------------------------------- Page 8 of ----13
Email Message related to Service Request
Number: 1-170397178
Customer Name: Jet Airways
Owner: David Onstot Message Sent: 12-Mar-2006 13:15:07
((GMT+05:30) Chennai, Kolkata, Mumbai, New Delhi)
Message Number: 1-170397178-4 Communication Status: Done
Communication Type:
From: [email protected] Due: 12-Mar-2006 13:15:44
Field Base:
To: <[email protected]>
Airplanes:
Registry Number Variable Number Serial Number Hours Cycles
Inquiry Type:
Subject: VT-JAS RH. Elev. tab. AOG AOG AOG
Body:
Dear Sir,
Lightening strike observed on Rh. elevator tab on our aircraft
VT-JAS , Line no- 2963, Aircraft Serial no.-29033, VAR No. PW422.
Due to lightening strike ,we are replacing RH. elevator tab [ part no.
65C26384-28A ].
The tab which has now been installed in the airplane weighs 5.40 lbs. thus
requiring Qty 02 balance adjust weights (P/N 69-53223-2) to be installed
(REF: AMM 27-31-31 & SRM 51-60-06).
JPL has in stock, balance adjust weights P/N 69-53223-1 which is not
defined in the IPC and not interchangeable with P/N 69- 53223-2 The SRM
Ref. 51-60-06 allows fabrication of the balance adjust weights as per the
dimensions and material specified therein.
Detailed study of the drawing shows that the difference between both the
part numbers is the provision of a fourth hole in P/N 69-53223-2 in
-------------------------------------------------------------------------------------------------- Page 9 of ----13
comparison with P/N 69-53223-1.
JPL would like to use the balance adjust weight P/N 69 - 53223-1 after
modification of the same by drilling the fourth hole as per the dimensions
from SRM 51-60-06 / Fig. 1 / Page 2.
.
Reply requested on AOG AOG AOG basis.
Thanks & regards,
Vijoy Kumar
Manager- Maintrol
-------------------------------------------------------------------------------------------------- Page 10 of ----13
Email Message related to Service Request
Number: 1-170397178
Customer Name: Jet Airways
Owner: David Onstot Message Sent: 12-Mar-2006 14:01:50
((GMT+05:30) Chennai, Kolkata, Mumbai, New Delhi)
Message Number: 1-170397178-5 Communication Status: Done
Communication Type: Boeing Response
From: BOECOM CAS BOC Due:
Field Base: BFSBOM-Mumbai-India
To: [email protected];[email protected]
Cc:
Airplanes:
Registry Number Variable Number Serial Number Hours Cycles
Inquiry Type:
Subject: VT-JAS RH. Elev. tab. AOG AOG AOG
Body:
FROM: THE BOEING COMPANY
TO: JPL [MESSAGE NUMBER:1-170397178-5] 12-Mar-2006 00:32:24 US PACIFIC TIME
Boeing Response
This message is sent to the following:
Maint. Defect Analysis Cell, at Jet Airways
Mumbai Maintrol, at Jet Airways
SERVICE REQUEST ID: 1-170397178
PRIORITY: AOG
ACCOUNT: Jet Airways (JPL)
DUE DATE: 11-Mar-2006
PROJECT: BFSBOM-Mumbai-India
PRODUCT TYPE: Airplane
PRODUCT LINE: 737
PRODUCT: 737-400
ATA: 5160-40
-------------------------------------------------------------------------------------------------- Page 11 of ----13
PART NUMBER:
AIRPLANE (VARIABLE/SERIAL): PW422/29033 REGISTRY: VT-JAS
HOURS/CYCLES:/
SUBJECT:
VT-JAS RH. Elev. tab. AOG AOG AOG
REFERENCES:
/A/ Boeing Service Request Message Number 1-170397178-1/-2/-3/-4
DESCRIPTION:
JPL would like Boeing to review the interchangeability between 69-53223-1 and 69-53223-2
RESPONSE:
Boeing Engineering has reviewed JPL reference /A/ request and provides the following:
Boeing Engineering has No Technical Objection (NTO) to JPL modifying 69-53223-1 into 69-53223-2 by
adding (1) additional 0.218 - 0.229 diameter hole per Boeing Engineering Drawing with special attention to the
location tolerance called-out on the Boeing Engineering drawing. Additionally JPL must re-identify the 69-
53223-1 as 69-53223-2 when the additional hole is installed.
David Onstot - BCA Operations Center
Sue Fullington
Commercial Aviation Services
The Boeing Company
BOEING PROPRIETARY
This message and any attachments to it contain or may contain Boeing proprietary material which is protected
at law and/or per the terms of existing agreements with Boeing. Proprietary material may be used by the
recipient only as permitted under the terms of any such prior agreement with Boeing. This message is
intended only for the named recipients. If you are not an intended recipient, you are hereby notified that any
further review, copying, use or dissemination of this message is strictly prohibited. If you have received this
-------------------------------------------------------------------------------------------------- Page 12 of ----13
message in error, delete it from your computer and/or other storage medium and notify the sender
immediately.
-------------------------------------------------------------------------------------------------- Page 13 of ----13