elevation top detail a bottom detail b€¦ · 3/4" = 1'-0" 1"-0" =...

1
VARIES ELEVATION 3/4" = 1'-0" NOTES: - ALL DOORS INCLUDE FACTORY PRE-MACHINING FOR HARDWARE. - ALL DOORS INCLUDE FACTORY SEALING OF EDGES. - ADDITIONAL TOP HINGE OVER THAT SPECIFIED BY NFPA80 IS REQUIRED FOR DOORS GREATER THAN 3'-6" WIDE OR 7'-6" TALL. - MAXIMUM 45 MINUTE FIRE RATING ALLOWED FOR DOORS OVER 3'-6" WIDE, 7'-6" TALL OR PAIRS WITH ASTRAGAL - CVR / CVC TOP LATCH AND STRIKE LOCATIONS DO NOT FOLLOW HARDWARE MANUFACTURER'S TEMPTE AND INSTALLATION INSTRUCTIONS. CONSULT AMBICO FOR STRIKE LOCATION. TOP DETAIL "A" 1"-0" = 1'-0" �£;��, CLAD ACOUIC DOOR - FIRE RAD AMBICO STC 41 TO C 3 SCIAUD DooRS ·F· WIND LEGEND: 1. WOOD úCE VENEER ( PULL SIDE ) . FACE VENEER TO BE: --- 2. WOOD úCE VENEER ( PUSH SIDE ) . FACE VENEER TO BE: --- 3. FIRE RATED ACOUSTIC CORE. 4. HARDWOOD STILES AND RAILS. 5. HEAT ACTIVATED SWEEP SEAL. 6. HEAT ACTIVATED SEAL. 7. 1 / 2" HIGH ACOUSTIC STEPPED THRESHOLD. 8. FINISHED FLOOR COVERING MATERIAL. 9. ACOUSTIC LINING. 2 1 " 4 BOOM DETAIL "B" 1"-0" = 1'-0" Ú: DWN : RISION: 0

Upload: others

Post on 31-May-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ELEVATION TOP DETAIL A BOTTOM DETAIL B€¦ · 3/4" = 1'-0" 1"-0" = 1'-0" bottom detail "b" 1"-0" = 1'-0" top detail "a" notes: - all doors include factory pre-machining for hardware

VARIES

ELEVATION 3/4" = 1'-0"

NOTES: - ALL DOORS INCLUDE FACTORY PRE-MACHINING FOR HARDWARE.- ALL DOORS INCLUDE FACTORY SEALING OF EDGES.- ADDITIONAL TOP HINGE OVER THAT SPECIFIED BY NFPA80 IS

REQUIRED FOR DOORS GREATER THAN 3' -6" WIDE OR 7' -6" TALL.- MAXIMUM 45 MINUTE FIRE RATING ALLOWED FOR DOORS OVER

3' -6" WIDE, 7' -6" TALL OR PAIRS WITH ASTRAGAL- CVR/CVC TOP LATCH AND STRIKE LOCATIONS DO NOT FOLLOW

HARDWARE MANUFACTURER'S TEMPLATE AND INSTALLATIONINSTRUCTIONS. CONSULT AMBICO FOR STRIKE LOCATION.

TOP DETAIL "A" 1"-0" = 1'-0"

�£�� ;��, CLAD ACOUSTIC DOOR - FIRE RAlED AMBICO STC 41 TO STC 51 SPfCIAUZED DooRS ·FRAMES· WINDOWS

LEGEND: 1. WOOD FACE VENEER (PULL SIDE).

FACE VENEER TO BE: ---2. WOOD FACE VENEER (PUSH SIDE).

FACE VENEER TO BE: ---3. FIRE RATED ACOUSTIC CORE.4. HARDWOOD STILES AND RAILS.5. HEAT ACTIVATED SWEEP SEAL.6. HEAT ACTIVATED SEAL.7. 1 /2" HIGH ACOUSTIC STEPPED THRESHOLD.8. FINISHED FLOOR COVERING MATERIAL.9. ACOUSTIC LINING.

21"4

BOTTOM DETAIL "B" 1"-0" = 1'-0"

DATE:

DRAWN BY:

REVISION: 0

AutoCAD SHX Text
4
AutoCAD SHX Text
6
AutoCAD SHX Text
1
AutoCAD SHX Text
9
AutoCAD SHX Text
2
AutoCAD SHX Text
9
AutoCAD SHX Text
3
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
7
AutoCAD SHX Text
8
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
DRAWING TITLE:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
REVISION:
AutoCAD SHX Text
WOOD CLAD ACOUSTIC DOOR - FIRE RATED
AutoCAD SHX Text
STC 41 TO STC 51
AutoCAD SHX Text
OCTOBER 17, 2016
AutoCAD SHX Text
TWB
AutoCAD SHX Text
0
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
3/4" = 1'-0"
AutoCAD SHX Text
1"-0" = 1'-0"
AutoCAD SHX Text
BOTTOM DETAIL "B"
AutoCAD SHX Text
1"-0" = 1'-0"
AutoCAD SHX Text
TOP DETAIL "A"
AutoCAD SHX Text
NOTES: - ALL DOORS INCLUDE FACTORY PRE-MACHINING FOR HARDWARE. - ALL DOORS INCLUDE FACTORY SEALING OF EDGES. - ADDITIONAL TOP HINGE OVER THAT SPECIFIED BY NFPA80 IS REQUIRED FOR DOORS GREATER THAN 3'-6" WIDE OR 7'-6" TALL. - MAXIMUM 45 MINUTE FIRE RATING ALLOWED FOR DOORS OVER 3'-6" WIDE, 7'-6" TALL OR PAIRS WITH ASTRAGAL - CVR/CVC TOP LATCH AND STRIKE LOCATIONS DO NOT FOLLOW HARDWARE MANUFACTURER'S TEMPLATE AND INSTALLATION INSTRUCTIONS. CONSULT AMBICO FOR STRIKE LOCATION.
AutoCAD SHX Text
LEGEND: 1. WOOD FACE VENEER (PULL SIDE). FACE VENEER TO BE: --- 2. WOOD FACE VENEER (PUSH SIDE). FACE VENEER TO BE: --- 3. FIRE RATED ACOUSTIC CORE. 4. HARDWOOD STILES AND RAILS. 5. HEAT ACTIVATED SWEEP SEAL. 6. HEAT ACTIVATED SEAL. 7. 1/2" HIGH ACOUSTIC STEPPED THRESHOLD. 8. FINISHED FLOOR COVERING MATERIAL. 9. ACOUSTIC LINING.