electroserv e482 leaflet
TRANSCRIPT
![Page 1: Electroserv E482 leaflet](https://reader031.vdocuments.site/reader031/viewer/2022020723/5888ca681a28ab200f8b6eb9/html5/thumbnails/1.jpg)
www.electroserv.co.uk
1www.electroserv.co.uk
Engineering. Designing. Procuring. Managing. Engineering Delivered.
Available from only
£150
E482 Controller
![Page 2: Electroserv E482 leaflet](https://reader031.vdocuments.site/reader031/viewer/2022020723/5888ca681a28ab200f8b6eb9/html5/thumbnails/2.jpg)
www.electroserv.co.ukwww.electroserv.co.uk
Contact us to find out more: +44 (0)1625 618526 [email protected] Electr0serv @Electr0serv Electr0serv 32
Easy to commission, easy to use… The perfect fit for OEM applications
In 2015 we launched our latest controller, the E482. With a selection of outputs, on board communications and a wipe down front the E482 is suitable for a range of applications.
WELCOME TO THE E482
Designed around the needs of the 21st Century working environment to create a reliable and easy to apply unit, the E482 controller works with you to help you achieve your day-to-day objectives for yield and cost.
Easily achieved benefits;
• Reliable and easy to use
• Improve quality – precise stable control means that your process stays within your quality limits
Easy to commission;
• RapidsetupwithQuickCodeconfiguration
• CustomisationoflistsandsettingswithPCbased Wizard
• Standard panel cut outs in DIN sizes
• Comprehensive support by phone or email
• Recoverypointsimplifiessupportbyensuringthat any operator can quickly revert the controllertoknownsettings
• Input Type - Thermocouple, resistance thermometerandmVinput.Currentandvoltagemeasurements available via external shunt
• Outputs-Relay,SSRlogicdrive,triacand4-20mADC outputs
• Digital Inputs-Contactclosurelogicinputstoswitchawiderangeofinstrumentfunctions
• Current Transformer - For current measurementenergyestimationcalculations,andheaterhealthdiagnostics
• Communications - Industry standard RS485 Modbus RTU communications
• Supply Voltage-Widerangingac/dcpowersupply options
Rear TerminalsAvailable now in-stock
Panel size (DIN) 1/8
IP Rating IP65
Display Type Main:4digits
Lower:Secondary4digits,amber
Third:4digits,amber
Supply Voltage 24Vac/dc
85-264Vac
Input Type TC,RTD,mV,mA,CT
PV Accuracy <0.25%
Control Types On/Off.PID
Special Features EnergyMonitoring,RecoveryPoint
Timer Functions Ramp/Soak,Delay,SoftStarter
Analogue IP/OP In: 2 Out: 1
Digital IP/OP In: 2 Out: 4
Digital Comms Modbus RTU – RS485
Alarm Types Hi, Lo, Dev, Sensor break, Event, Heater fail
Industry Certifications CE, cUL, RohS
PC Configuration Wizard/iTools
FEATURES E482
481 to E482 wiring
E482 Comprehensive terminal range
![Page 3: Electroserv E482 leaflet](https://reader031.vdocuments.site/reader031/viewer/2022020723/5888ca681a28ab200f8b6eb9/html5/thumbnails/3.jpg)
www.electroserv.co.uk
International: +44(0)1625618526Email: [email protected] Buy online: www.electroserv.co.uk Designed by Plinkfizz
KILNS,OVENSANDFURNACES BATCHOPERATION
PLASTICPROCESSINGCONTROL(EXTRUDERSANDCHILLERS)
The E482 controller is well adapted to ovens, small furnaces and kilns. Formachinessuchasasmallkilnforfiringceramicsoranoventreatingcomplexsmallparts,thetimerfunctioncangraduallyincreasethetemperaturetothedesiredsetpoint–preventingthermalshockordamage/distortiontotheworkpiecesbeingheated.
The timer automatically maintains the temperature for the desired dwell period,beforeturningpowerofftoallowtheitemstocool.Anover-temperature alarm may be used to control an interlock on the door as a basic safeguard.AllofthismaybecontrolledeitherusingtheE482controller fascia, or from an external switch wired to an input on the controller.
Electroserv+havevastexperienceinPlasticProcessingcontrol and has helped improve the productivity of customers’single-screw,twin-screw,co-extrusion,orblownfilmsystemsbytakingbettercontrolofthetemperature.UsinglowcostOn/OfftemperaturecontrollersorpoorPIDcontrollers can result in variation of temperature in the feed throat, barrel and head which can ultimately lead to poor levels of productivity.
TheprecisePIDcontroloftheE482controllerisusedtoensureuniformheatingofthematerialtoavoidmaterialdegradation,unduestrain on the extruder components, and improve process reliability.
Chillersareusedintheplasticsindustrytoprotectvaluableprocessingequipment –suchasextrusion,injectionmoldingequipmentandotherapplications.Anotherreason fortheiruseistoincreaseproductionthroughconstantandpropercoolingtemperaturesinthe equipment.
Achillerwillreducethenumberofrejectedpartswhileincreasingthenumberofpartsproducedperhour.Achillerisacompressorbasedcoolingsystemthatissimilartoanairconditioner except it cools and controls the temperature of a liquid instead of air.
The E482 controller can be used to consolidate functions and replace several interconnected devicestochillers,includinganexternaltimer.Theleveloffunctionality,programmabilityandalarminggivestheuserawaytocreatealocalcustomalarmstrategythatcanbestachievetheoperatingsafetyofthemachine,minimisedowntimeandimprovequality.
Photograph courtesy of Wisconsin Oven
Photograph courtesy of Welex
Photos displayed are purely to demonstrate applications that these controllers are suited to.Control systems on these specific units may differ from this product being offered. Photograph courtesy of Mokon
The simple timer in the E482 controller may beusedtocontrolbatchoperations,e.g.foodovens, sterilisers, fryers. Ideal for any application requiringasingledwellattheendofeitheracontrolled ramp or natural approach to setpoint withouttheneedforanadditionaltimingdevice.Thiscanalsobeusedtoautomaticallybringtheprocess up to temperature ready for production tostartinthemorning.
Whetherit’sforexcellenceincontroleasysetuporeasystraightforwardfunctionality,theE482controllerscanbeusedacrossabroadrangeofapplicationsto solve problems.
Real-world applications