electronic fluorescent ballast matrix...electronic fluorescent ballast matrix ... ballasts shall be...
TRANSCRIPT
ELECTRONIC FLUORESCENT BALLAST MATRIX
Lamptype^^Qty
••••••1
F17T8, 2F25T8, orF32T8
3
4
1
F40T8
2
3
1
F96T8
2
1
F96T8HO
1
F40TI2&F40T12ES
3
F96T12& 1F96T12ES 2F96T120HO&F96T120HOES
VoltageHH
120277347120277347120277347120277347
120
277
120
277
120277120120277277347120120277277347120277120277120277120277120277
120
120277
"R" educed "H" armonic (THD < 20%)
Low ProfileInstant Start
B132I120RH-AB132I277RH-A
B232I120RH-AB2321277RH-A
B332I120RH-AB3321277RH-A
B432I120RH-AB432I277RH-A
B132I120RH-AB232I120RH-AB132I277RH-AB232I277RH-AB332I120RH-A
B332I277RH-A
Standard CanInstant Start
B132I120RHB1321277RH
B232I120RHB2321277RH
B332I120RHB3321277RH
B432I120RHB432I277RH
B132I120RHB232I120RHB132I277RHB232I277RHB232I120RHB332I120RHB2321277RHB332I277RH
B159I120RH
B159I277RH
B259I120RH
B259I277RH
B286I120RHB286I277RHB286I120RHB286I277RH
B2601120RHB260I120RH
Programmed RapidStart -AccuStart™
••••H^BB132P120RHB132P277RH
B232P120RHB232P277RH
B332P120RHB332P277RH
B432P120RHB432P277RH
"H" igh "P" erformance (THD < 10%)
Universal VoltageLow ProfileInstant Start
B132IUNVHP-BB132IUNVHP-B
B232IUNVHP-BB232IUNVHP-B
B332IUNVHP-AB332IUNVHP-A
B432IUNVHP-AB432IUNVHP-A
B132IUNVHP-BB232IUNVHP-BB132IUNVHP-BB232IUNVHP-BB332IUNVHP-A
B332IUNVHP-A
Standard CanInstant Start
B132I120HPB132I277HPB132I347HPB232I120HPB232I277HPB232I347HPB332I120HPB3321277HPB332I347HPB432I120HPB432I277HPB432I347HP
B240I120HP
B240I277HP
B340I120HPB340I277HPB259I120HP
B259IUNVHP-AB259I277HP
B259IUNVHP-AB2591347HPB259I120HP
B259IUNVHP-AB259I277HP
B259IUNVHP-AB259I347HP
B260I120HPB260I277HP
Rapid StartBH1HB
B232R120HPB232R277HP
B332R120HPB332R277HP
B432R120HPB432R277HP
B140R120HPB140R277HPB240R120HPB240R277HPB340R120HPB340R277HP
B295SR120HPB295SR277HP
Programmed RapidStart -AccuStart™••••••H
B132PUNVHP-AB132PUNVHP-A
B232PUNVHP-AB232PUNVHP-A
aMagneTek
UMIVERS/U- Triad*Trusted Braid Nlnns-Brand New fechralosy
PAGE 2-13
FOR MORE INFORMATION CALL
1-800-BALLAST(225-5278)
Specifications
TYPICAL SPECIFICATIONSFOR INSTANT START BALLASTS FOR:
•RH (Reduced Harmonics)• L (Low Wattage)• RHH (Reduced Harmonics High Light)
1. Ballasts (1 -4 lamp) shall operate as a Parallel Circuit, allowing remaining lamp(s) to maintain full light outputif one or more lamps fail.
2. Ballasts shall operate from 60 Hz input source of 120, 277 Volts, and sustained variations of±10% (Voltage & Frequency) with no damage to the ballasts.
3. Ballasts shall be a high frequency electronic type, and operate lamps at a frequency above 20 kHz.4. Lamp Current Crest Factor (ratio of peak to RMS current) shall be 1.7 or less in accordance with lamp
manufacturer recommendation and ANSI C82.11-1993.5. Ballasts shall tolerate operation in ambient temperatures up to 105°F (40°C) without damage.6. Ballasts shall comply with FCC Part 18 Non-Consumer Equipment for EMI (power line conducted) and
RFI (Radiated).7. Ballasts shall provide transient immunity as recommended by ANSI C62.41 -1991, Location A2.8. Ballasts shall operate lamps with no visible flicker (<3% flicker index).9. Ballasts shall tolerate sustained open circuit and short circuit output conditions without damage.10. Ballasts shall be Underwriters Laboratory (UL 935) listed, Class P, Type 1 Outdoor, and CSA certified
where applicable.11. Ballast shall have a Ballast Factor greater than .85 per ANSI C82.11 -1993.
- Ballast Factor for Low Power (L) models shall be greater than .77.12. Input current Total Harmonic Distortion shall not exceed 20% for the primary lamp applications13. Ballasts shall have a Power Factor greater than .95 for primary lamp applications.14. The ballasts do not contain any PCB's.15. The manufacturer shall provide written warranty against defects in material or workmanship, including
replacement, for five years from date of manufacture.16. Manufacturer shall have been manufacturing electronic ballasts for at least fifteen years.17. Ballast shall be manufactured in an ISO 9002 Certified Facility18. Ballasts shall provide instant starting sequence consistent with ANSI standard C82.11 -1993.19. MagneTek model* (or approved equal).
ii MagneTek
UNIVERSAL TriadTrusted 8rand NaniEs...Bianil New Technology
PAGE 2-8
FOR MORE INFORMATION CALL
1-800-BALLAST(225-5278)
TRIAD® ELECTRONIC BALLASTSFOR(1)
F17T8 LAMP
• Low ProfileDesigns Featured
• Instant & ProgrammedRapid Starting Options
• 1 Lamp Applications
F17T8
Lamp | j | CertificI Starting Line Catalog /rr\ I is
(My. Method Volts Number (l) (§
ation 1 Lineft 1 tmn Current1 NOM (Amps)
InputPower(Watts)
PowerFactor(PR
BallastFactor(BF)
BallastEfficacy
Factor (BEF)THO%
Min.F/CStartTemp
WiringDiag. Dim.
• FI7T8 - One Lamp Application ^^^^^^^^^1120 B132I120RH127 B132I127RH
0.150.16
277 B132I277RH • • 0.07347 B132I347RH • 0.05
1 IS 120 B132I120RH-A277 B132I277RH-A120 B132I120HP277 B132I277HP •347 B132I347HP120
0.170.070.160.070.05n n
1 " B132IUNVHP-B • • "I277120 B132P120RH277 B132P277RH
PRS120
B132PUNVHP-A •277
O.US
0.17
0.07
0.150.07
181818181920181818
19
2020
17
>.95>.90>.95>.95>.90>.90>.98>.98>.95>.99>.97>.90>.90>.99>.96
0.930.970.930.920.930.930.920.920.92
0.93
0.950.95
0.91
5.175.395.175.114.894.655.115.115.11
4.89
4.754.75
5.35
<20<32<20<20<32<32<20<15<15< 10< 15<25<25<10< 15
0/-180/-180/-180/-180/-180/-180/-180/-180/-18
0/-18
0/-I80/-18
0/-18
l
l1
l22
2
STSTSTST-A-ASTSTST
-B
STST
-A
IS = Instant StartPRS = Programmed Rapid StartRS = Rapid Start
STARTING METHOD LEGENDPAR-IS = Parallel Instant StartPAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid StartSER-RS = Series Rapid Start
Overall Dimensions Mounting DimensionsDraw#
ST-A-B
L9.50"9.50"9.50"
w2.40"1.70"1.50"
H1.55"1.18"1 .00"
M8.89"8.89"8.89"
X1 .69"
1 .69"
0.88"
WIRING DIAGRAMS
DIAGRAM 1
RedRed
DIAGRAM 2
MMagneTek
UNIVERSAL Triad*Trailed Brand Names Jiraml New Technology
Page 2-15
FOR MORE INFORMATION CALL
1-800-BALLAST(225-5278)
TRIAD® ELECTRONIC BALLASTSFOR (DF25T8 LAMP
• Standard & Low ProfileDesigns Featured
•Instants ProgrammedRapid Starting Options
• 1 Lamp Applications
F25T8
Lamp : | CertiI Starting Line Catalog r/ff\Tl
Qty. Method Volts Number I W I V
ication | LineSR 1 n™. Current& 1 NOM 1 (Amps)
InputPower(Watts)
PowerFactor(PF)
BallastFactor(BF)
BallastEfficacy
Factor (BEF)THD
%
Win. F/CStartTemp
WiringDiag. Dim.
• F25T8 - One Lamp Applications ^^^^^^^^^^H120 B132I120RH127 B132I127RH277 B132I277RH347 B132I347RH120 B132I120RH-A
1 IS 277 B132I277RH-A120 B132I120HP277 B132I277HP347 B132I347HP120,± B132IUNVHP-B277120 B132P120RH277 B132P277RH
1 PRS120... B132PUNVHP-A '277
0.220.220.100.070.220.100.220.090.070.22•0.100.230.100.20•0.09
25272525262725252525252828
24
>.95>.90>.95>.95>.97>.97>.98>.98>.95>.99> .97>.95>.95>.99>.98
0.920.980.920.900.920.920.910.910.90
0.92
0.900.90
0.91
3.683.633.683.603.543.413.643.643.60
3.68
3.213.21
3.79
<20<20<20<20<25<25<10<10<10
<10
<20<20
<10
0/-180/-180/-180/-180/-180/-180/-180/-180/-18
0/-18
0/-180/-18
0/-18
ll1llllll
l22
2
STSTSTST-A-ASTSTST
-B
STST
-A
1
1I
IS = Instant StartPRS = Programmed Rapid StartRS = Rapid Start
STARTING METHOD LEGENDPAR-IS = Parallel Instant StartPAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid StartSER-RS = Series Rapid Start
Overall Dimensions Mounting DimensionsDraw*
ST-A-B
L9.50"9.50"9.50"
w2.40"1.70"1.50"
H1.55"1.18"1 .00"
M8.89"8.89"8.89"
X1.69"1.69"0.88"
WIRING DIAGRAMS
H\
-A.-B DIAGRAM 1
^ SlackAWiite
Line White BALLASTBlueRedRed
f \
LAMP j
MMagneTek
UNIVERSAL Triad"tested Bund femes ..Brand New Tedinohgy
Page 2-19
DIAGRAM 2
FOR MORE INFORMATION CALL
1-8OO-BALLAST(225-5278)
^^^^M • Low Profile'WM l.fl £*z^_uIHHH H /< &^^^^^B ((
^^^^^^^^H V u
Designs F
• Instant, RProgramnStarting 0
eatured
apid &led Rapidptions
TRIAD® ELECTRONIC BALLASTSFOR (DF32T8 LAMP
BBSBBBB BI H • •) [_3fpn Applications
Lamp ! 1 Certi1 Starting Line Catalog ^r\ \ &
Qty. Method Volts | Number \\$) 1 <S
ication 1 LineB 1 NDM Current
B | NOM | (Amps)
InputPower(Watts)
PowerFactor(PF)
BallastFactor(BF)
BallastEfficacy
Factor (BEF)THD%
Min.F/CStartTemp
WiringDiag. Dim.
1 3 2 1 8 - One Lamp Applications ^^^^^^^^^^^^^1120 B132I120RH127 B132I127RH277 B132I277RH347 B132I347RH120 B1321120RH-A
1 IS 277 B132I277RH-A120 B132I120HP277 B132I277HP347 B132I347HP
™ B132IUNVHP-B •2.1 i
120 BI32P120RH
DDC 277 B132P277RH120
B132PUNVHP-A •
0.26
0.26
0.11
0.09
0.26
0.11
0.26
0.11
0.09
0.27
0.13
0.27
0.12
0.26
0.11
303130313032303031
31
32323130
>.98
>.90
>.98
>.98
>.98
>.97
>.99
>.99
>.98
>.99
>.98
>.95
>.95
>.99
>.98
0.88
0.97
0.88
0.88
0.88
0.88
0.88
0.88
0.88
0.91
0.88
0.88
0.91
2.93
3.132.93
2.84
2.93
2.75
2.93
2.93
2.84
2.94
2.75
2.75
2.94
3.03
<20<20<2()
<20<20<20<10<10<10
<10
<20<20
<10
0/-180/-180/-18
0/-180/-180/-180/-18
0/-180/-18
0/-18
0/-18
0/-18
0/-18
i
2
2
2
STSTSTST-A-ASTSTST
-B
STST
-A
IS = Instant StartPRS = Programmed Rapid StartRS = Rapid Start
STARTING METHOD LEGENDPAR-IS = Parallel Instant StartPAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid StartSER-RS = Series Rapid Start
Overall Dimensions Mounting DimensionsDraw*
ST-A-B
L9.50"9.50"9.50"
w2.40"1 .70"
1 .50"
H1. 55"1.18"1.00"
M8.89"8.89"8.89"
X1.69"1.69"0.88"
WIRING DIAGRAMS
u\
DIAGRAM 1
Blue_RedRed
LAMP
DIAGRAM 2
MMagneTek
UNIVERSAL Triad"Trusted Bland Names...Brand New Technology
Page 2-24
FOR MORE INFORMATION CALL
1-800-BALLAST(225-5278)
TRIAD® ELECTRONIC BALLASTSFOR (DF40T8 LAMPS
• Low ProfileDesigns Featured
• Instant Start
• 1 Lamp Applications
F40T8
[ Lamp iI Starting Line
Qty. Method Volts
; CertifCatalog I /JT\ I /
, Number | QjJ M
cation | Line
§ | Current| NOM 1 (Amps)
InputPower(Watts)
PowerFactor
| (PF)
BallastFactor(BF)
Ballast :
Efficacy THDFactor (BEF)| % |
Min .F/CSartTemp
WiringDiag. Dim.
• F40T8 - One Lamp Applications ^^^^^^^^^H120127277
B132I120RHB132I127RHB 1321277RH
120 B132I120RH-A277 B132I277RH-Al?f)I± B132IUNVHP-B •277120 B232I120L277 B232I277L120 B232I120L-A277 B232I277L-A120 B232I120RH
1 IS 127 B2321127RH277 B232I277RH120 B232I120RH-A127 B232I127RH-A277 B2321277RH-A347 B232I347HPL120 B232I120HP277 B232I277HP120 B240I120HP277 B240I277HP1?0if; B232IUNVHP-B •
0.300.300.130.300.130.32
* 0.140.33
« 0.140.340.150.360.370.170.380.380.170.110.370.170.370.160.37
t •
0.18
3639363537
38
3737404042424245454538454545454544
>.95>.98>.95>.96>.95>.99>.98>.95>.95>.95>.95>.95>.95>.95>.95>.95>.95>.98>.95>.95>.95>.95>.99>.98
0.870.900.870.830.83
0.86
0.880.880.910.911.001.001.001.031.031.030.861.031.031.001.000.960.97
2.422.312.422.372.24
2.26
2.382.382.282.282.382.382.382.292.292.292.262.292.292.222.222.132.20
<20<20<20<15<15<15<10<20<20<25<25<20<25<20<25<25<25<10<15<15<10<10<10<10
0/-1850/100/-1850/1050/10
0/-18
0/-180/-180/-180/-180/-180/-180/-180/-180/-180/-180/-180/-180/-1850/1050/10
0/-18
l333333333333333
3
STSTST-A-A
-B
STST-A-ASTSTST-A-A-ASTSTSTSTST
-B
STARTING METHOD LEGENDIS = Instant Start PAR-IS = Parallel Instant StartPRS = Programmed Rapid StartRS = Rapid Start
1 Overall DimensionsDraw # L
ST 9.50"-A 9.50"-B 9.50"
"V—-^y%\r-=r^
=:=^~
^^l
W2.40"1 .70"1.50"
-~\==="1
-- -"""""" ^
PAR-PRS = Parallel Programmed Rapid StartPAR-RS = Parallel Rapid StartSER-RS = Series Rapid Start
•I'lMHllllJllLlfflffifa W1K1NU IJ1AUKAMSH M
1.55" 8.89"1.18" 8.89"1 .00" 8.89"
"Y--- ' —«S^^v~^
X1 .69"1 .69"0.88"
^L.^M-^H3
. — - L —
Black/White1^ While BALLAST
i
Blue
Red
— |LAMP |=— H
ST "" "A. "B DIAGRAM 1
BALLAST
Blue
Blue
Red
!=[
iiMagneTek
[UBIIVEHSAI.-J Triad"Trusted Brand Names.Jrand NewTechndogy
For One Lamp Operation, Insulate one blue lead to 600V
DIAGRAM 3
Page 2-31
FOR MORE INFORMATION CALL
1-800-BALLAST(225-5278)
F25T12• Low ProfileDesigns Featured
• Instant Starting Options•1-2 Lamp Applications
TRIAD® ELECTRONIC BALLASTSFOR (1) AND (2)
F25T12 (ANSI LAMP ONLY) LAMPS
Lamp ;Starting Line
City. Method Volts
CertifCatalog ^ \ *Number (&) Vs
cation Line•R 1 ..„.. Current£ NOM (Amps)
InputPower(Watts)
PowerFactor(PF)
BallastFactor
(BF)
BallastEfficacy
Factor (BEF)THO%
Win. F/CStartTemp
WiringDiag. Dim.
F25T12 - One Lamp Applications ^^^^^^^^^^^^^^^H120277347
, „ »347120
277
B132I120RH
B132I277RH
B132I347RH
B132I120RH-A
B1321277RH-A
B132I347HP
B132IUNVHP-B
0.220.100.07
0.220.100.070.24
0.10
26262526
27
25
26
>.95>.95>.95>.97>.97>.98>.99>.98
0.79
0.79
0.79
0.79
0.79
0.79
0.92
3.043.04
3.16
3.04
2.93
3.16
3.64
3.64
<20<20<20>25
>20
<10
< 10
0/-18
0/-18
0/-18
0/-18
0/-I8
0/-18
0/-18 1
STSTST-A-AST
-B
F25T12- Two Lamp Applications ^^^^^^^^^^^^^^^H120277120277120277347
2 PAR-IS 120
127277347347120
277
B232I120L
B232I277L
B232I120L-A
B232I277L-A
B232I120RH
B232I277RH
B232I347RH
B2321120RH-A
B232I127RH-A
B2321277RH-A
B232I347HPL
B232I347HP
B232IUNVHP-B •
0.390.16
0.350.16
0.41
0.19
0.14
0.42
0.42
0.18
0.12
0.14
0.41• •
0.17
41414343505047494949414749
48
>.95>.95>.95>.95>.95>.95>.95>.95>.95>.95>.99>.99>.99>.99
0.68
0.68
0.78
0.78
0.79
0.79
0.79
0.93
0.93
0.93
0.68
0.79
0.91
1.661.66
.81
.81
.58
.58
.68
.90
.90
.90
.66
.68
.86
.90
<20<20<20<20<20<20<20<20<20<20<10< I O< 1 0
<15
0/-18
0/-18
0/-I8
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-18
0/-180/-18
0/-18
333333333333
3
STST-A-ASTSTST-A-A-ASTST
-B
IS = Instant StartPRS = Programmed Rapid StartRS = Rapid Start
STARTING METHOD LEGENDPAR-IS = Parallel Instant StartPAR-PRS = Parallel Programmed Rapid Start
PAR-RS = Parallel Rapid StartSER-RS = Series Rapid Start
Overall Dimensions Mounting DimensionsDraw*
ST-A-B
L9.50"9.50"9.50"
w2.40"1.70"1.50"
H1 .55"1.18"1 .00"
M8.89"8.89"8.89"
X1 .69"1 .69"0.88"
WIRING DIAGRAMS
MN
DIAGRAM 1
Line BALLAST
l=tLAMP
LAMP
MMagneTekDIAGRAM 3
UNIVERSAL Triad'Trusted Brand NaiK Jmd New Technology
Page 2-38
FOR MORE INFORMATION CALL1-80O-BALLAST
(225-5278)
Product Overview
Low Profile Reduced Harmonic (RH-A)Our new low profile RH ballasts are over 45% smaller and 30% lighter. They feature a space-savingpackage (1.18" height) and cross section for greater flexibility in fixture design. The 1 -4 lamp modelfeatures parallel lamp operation, with standard mounting footprint and wiring for ease of replacement.They offer high efficiency performance with THD <20%.
Reduced Harmonic (RH)Our Reduced Harmonic ballasts offer high efficiency with THD <20%. They're ideal for standard lightoutput applications (.88 Ballast Factor). They're available for a variety of T8 lamp applications.
Universal Voltage Low Profile High Performance (HP-A & HP-B)Our new low profile High Performance ballasts with THD <10% offer the convenience of universal inputvoltage (108 - 305 volts) as a standard feature. Universal input is "installer-friendly" — ensuring thatyou have the right voltage ballast every time. Our low profile models also feature a remarkably smallpackage and cross-section for greater flexibility in fixture design. Since the mounting and wiring foot-prints are the same as a standard ballast, our low profile HP models will easily retrofit into any T12 orT8 fixture.
High Performance (HP)MagneTek's High Performance ballasts are designed for applications with stringent power qualityrequirements. They offer ultra-quiet operation (sound-rated A+), high power factor (>.98) and lowharmonic distortion (<10% THD).
AccuStart ™AccuStart™ ballasts are ideal for frequently switched applications or as a rapid start alternative. Theyincorporate patented programmed rapid start technology to properly heat the lamp filaments, whichyields an increase in lamp life up to 50%.
Family of RH ballasts. AccuStart™ ballasts for frequently switched applications.
MMagneTek
UNIVERSAL Triad'Tmmiiaaitlana.JafiHaiWmk^
PAGE 2-2
FOR MORE INFORMATION CALL
1-800-BALLAST(225-5278)
Nomenclature
UNIVERSAL PRECISE™
ABBREVIATIONS
CWA Constant Wattage Autotransformer
CWI Constant Wattage Isolated
ISO Reg
R-HPF Reactor High Power Factor
R-NPF Reactor—Normal Power Factor
HX-HPF Lag Type — High ReactanceAutotranstormer—High Power Factor
HX-NPF Lag Type — High ReactanceAutotranstormer—Normal Power Factor
UL Bench Top Rise Temperature Code
To facilitate UL inspection, the UL Bench Top RiseTemperature Code is shown on the MagneTek Core& Coil Ballast label as 1029X. 1029 is the ULStandard for HID Ballasts, and the X is thetemperature code. If a fixture is UL listed for1029D, then automatically all ballasts with an A, B,C or D temperature classification are acceptable foruse within that same fixture.
UL Bench Top Rise Letter CodeTemperature Range forClass H (180° C) Ballasts
A<75°C B 75°C < 80°CD85°C<90°C E90°C<95°C
C 80°C < 85°CF95°C<100°C
leiu
1
1
M
If!•*Z-o• — ' CD
2 3^ M, ,.-.-,1
NUITID
2 to 42 0 0 0
^ Q) ^
fii(aCD
3
M L T
MCj !H < TPO i o r.Cd ro S s a°^^«1l^^q CD -3
^J 33
4 5
er of Digits
1
A
Circuit Type
(R/A
/I/O/L/M
)
1
C
Style
(C/F/W
/E/I/P
)
6 7 8
1
5
Frame S
ize(E
/3/4/5/X)
1
M
Socket Type & OtherOddities (M/D/X/L)
3
0 0 0
^_ll-^0 oto °c§ °-<em
9
1C
Container Type
(C/T/I/K)
Field
1
2
3
4
5
6
7
8
9
Description
(M) Metal Halide, (P) Pulse Start, (S) High Pressure Sodium, (H) Mercury
35 to 2000 Watts (Varies from two to four digits)
(MLT) Quad, (MLS) Multi-5, (TRI) TriVoit, (48T) 480/120, (120) 120, (277) 277, (230) 230V/50Hz
(R) Reactor, (A) CWA, (I) CWI, (0) IsoReg, (L) High Reactance/Lag, (M) MagLag
(C), C&C, (F) F Can/E&P, (W) Weatherproof, (E) Encased/Potted C&C (I) Indoor Encased, (P) Postline
(E) E&l, (3) 3x4, (4) 4-3/4, (5) 5-3/4, (X) Non Core and Coil
(M) Mogul or Medium, (D) Double Ended, (X) Multiple Lamps, (L) Low Loss
Pack Code (000 to 999, per pack code listing)
(C) Carton, (T) Tray, (I) Individual, (K) Kit
ii MagneTek
UNIVERSAL Tri^scfTurned Bland Nmes...Biand IkwTgcMogy
PAGE 5-10
FOR MORE INFORMATION CALL
1-800-BALLAST(225-5278)