electromechanical operator for sliding gates

28
ACER DL E D I S N I L I O AC8R DL AC12R DL ELECTROMECHANICAL OPERATOR FOR SLIDING GATES INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

Upload: others

Post on 02-Oct-2021

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

ACER DL

EDISNI

LIOAC8R DLAC12R DL

ELECTROMECHANICAL OPERATOR FOR SLIDING GATESINSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE

Page 2: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

2

STANDARD INSTALLATION

AC001

RECAinoizurtsiidelaunaM

RECAinoizurtsiidelaunaM

RECA

Fig.1: Components and devices of a typical automation.

Fig.2: Description of the contents of the ACER pack.

Page 3: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

Fig. (1)

AC017

3

2

1

Fig.1.2

Fig.1.1 Fig.1.3

ECU - 24 V d.c.

zH 05 caV 032 V.c.d V 42

.c.a V 032 V

003 082 052 WA 1,1 1,2 1,4 µF 14 14 16 N 500 700 900

Type °C 140 NO

10 nim/m4

61 61 81

08 53 % min 10 20

° 44

DF

170 (plate) x 342 x 288 (h) mm / 10 kg

150 1506 6

6/12 11

10

44

300 600

ECU - 230 Vca 50AC3R M DL AC6R M DL

RG1R 24 DLRG1R 24 DL

NO500300

48

NO

AC12R DLRG1R DLRG1R DLRG1R DLRG1R DL

AC4R DL AC6R DL AC8R DL

3501,616

1200

8

1200

IP

Built-in ECUPower supplyMotor power supplyMotor powerPower input from mains 230V / Max. motor absorption at pick-up 24 VCapacitorThrustLubricationThermal protection deviceLimit switchEncoder SpeedExternal toothed wheel moduleNumber of teeth external toothed wheelWork cycleNominal work timeBattery recharge time (optional)*Opening cycles with charged battery*Operating temperatureProtection classMotor insulation classAssemblyDimensions / weightDont use in acid, saline or potentially explosive environment

Version:

ACER: Irreversible electromechanical operator for sliding gates with optical/magnetic encoder and built-in ECU

2 electromechanical or magnetic limit switches in M versionoptical magnetic

BATTERY NOT PROVIDEDBATTERY NOT PROVIDED

C from -20 a +70 from -20 a +70

horizontal with dedicated anchorage plate

LIFE home integration reserves the right to make changes to technical characteristics at any time and without prior notice, without changing its intendeduse and function.

TECHNICAL FEATURES

* for 2 Ah batteries (optional and installed).

Attention:• The fitter must permanently fix the label describing the manual release operation close to the manual release key.• The activation of the manual release could cause an uncontrolled movement of the gate in the event of mechanical damage or unbalanced conditions.• Before performing the manoeuvre switch off the electricity supply to the automation.• To avoid breaking the key, do not apply excessive force.a) Slide the lock protection cover (1). See fig. (1.1).b) Insert the key (2) in the lock and turn to the right through 90°.See fig. (1.2).c) Gently pull the key outwards until the hatch is protruding, then pull outwards until it stops. See fig. (1.3).d) The operator is now free and can be moved by hand. A microswitch assembled on the blockage device prevents the motor from operating whenthe power comes back on.e) To reconnect the transmission, turn the opposite way and move the gate manually until it hitches up.

1.1 Operator release

1.0 INSTALLATION

Grease GreaseGrease GreaseOil Bath Oil Bath

Max gate weight (lev el gate) kg 400 600 800

Page 4: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

4

Fig. (2)

335

81

170

582

003

22 170

192

5961z

9981z

18

AC003a

7861z

1981z

45

Fig. (3)

XD

XS

Fig. (4)

1

4

350

250

200

3

AC005

21

AC010

4

350

250

200

AC010

35

Fig.4.1 Fig.4.2

1.2 Installing operator components: positioning and installation of the anchorage plate

The area in which the operator is installed must provide adequate space for performing maintenance and manual release operations.a) Adhere to the dimensions in �g.2.

Left Hand

Right Hand

ATTENTION: If the operator is subject to heavy work conditions or if the weight of the leaf is over 300 kg, the anchorage plate (1) must be sunk into the concrete.

b) Observe the orientation in �g. (3) for positioning the operator anchorage plate (R – L).c) Refer to �g. (2.2) for the respective heights for 16 or 18-tooth pinions.d) Lay the electric cable pipes (4), allowing them to protrude and plugging them to prevent them from �lling with debris.Fasten the anchorage plate (1) to the concrete base with 4 expanding screw anchors (2), see �g.(4.2); or sink in the fresh concrete folding the two “L”s (3), see �g.(4.1).

Page 5: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

5

Fig. (5)

AC037

AC3R M DL

AC012

7

7

AC012

6

5

7

1

2

1

8

8

8

9

8

AC013 10

7

4

Fig.5.1

Fig.5.2 Fig.5.3

Fig. (6)

B

A

AC6R M DL AC4-6-8-12R DL

a) Remove the lid (2) of the operator by loosening the screws (1); rest the operator on the anchorage plate and manually turn the 4 M10 screws (7) withthe relative washers through 3/4 of a revolution. See �g. (5.1).b) Vertically adjust the operator using the 4 dowels (8) levelling it with the spanner (9); adjust the operator so that it is parallel to the gate. See �g. (5.2).c) De�nitively fasten the operator by blocking the 4 M10 screws (7) and the relative washers with a �xed or tube wrench (10). Assemble the coverson the clamping feet (4). See �g.(5.3).

1.4 Installing operator components: rack assembly

Assemble the “gate open” (A) and “gate closed” (B) limit switch brackets at the ends of the rack, fastening them with the screws provided in the packas indicated in �g. (6). Remember that the gate will travel 2-3 cm more, after the intervention of the limit switch, consequently adjust the position ofthe brackets so that the gate does not collide with the mechanical stop plates.

1.3 Installing operator components: positioning and installation of the operator

mm

1

Page 6: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

6

fig. (7).

AC021

2

1

AC020

2

1

2

1

18

17

4

3

Fig.7.1 Fig.7.2

2.0 WIRING AND CONNECTIONS• The operator must be connected to the relative Life electronic control unit (ECU).• All wiring and connection operations must be carried out with the control unit disconnected from the electricity supply. If the disconnection device is not in view, display a sign reading: “ATTENTION: MAINTENANCE WORK IN PROGRESS”.The internal linear electromechanical operator wiring performed by the Manufacturer, may not be modified under any circumstances.

2.1 Electric connections

ATTENTION: the cables used must be suited to the type of installation. It is the Fitter’s responsibility to choose appropriate material.

• The power cable may be no lighter than 60245 IEC 57 ( HO5RN-F).• Inside the power cable, one wire must be yellow and green.• The power cable coating must be composed of a polychloroprene sheath.• All wires must be unsheathed as little as possible (6mm at the most) and as close as possible to the connection terminals, in order to prevent accidentalcontact with live parts in the event that cables disconnect from the terminals.• Do not pre-seal cables to be fastened to the terminals using screws.• A power cable-fastening device must be provided. Assemble the power cable so that if it comes out of its fastening device, the neutral and livewires are taut before the earth wire.

2.2 Introducing the electric wires into the operatora) To access the ECU remove the cover (2) of the reduction gear removing the two lateral clamping screws (1).b) Open the pre-punched holes in the cable gland door (3), insert the cable glands (17), then insert the cables (18) needed for the connections (keep230 V and very low voltage cables separate). Leave the cables about 40cm longerc) Assemble the cable gland door making it stick well to the edges of the seat in the operator base to prevent access to insects and dirt. See fig. (7).

2.3 Electronic control unit connections

Fitters must make the connections of the 230 Vac 50 Hz electricity supply, and the various automation devices. Connections between the ECU, motor,encoder and autotransformer have already been performed by the Manufacturer.

ATTENTION: for safety reasons, it is essential to earth the motor.

Crimp the yellow and green wire on the power cable to the loop on the upper sleeve, at the point marked by the earth symbol as indicated in fig. (7.1).To facilitate ECU connection operations and programming, it can be removed from its housing. The operation is straightforward and does not require theuse of any tools:a) remove the ECU by pulling upwards and, compatibly with the length of the cables, rest on the edge of the operator base or hold.Once the wiring and/or programming work is complete, place the control unit back in its recess by pressing lightly until the 4 clips snap in. See fig. (7.2).

Connection

Electricity supply line

Type of cable

3x1,5 mm2 cable

Page 7: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

7

and will be subject to Translation into other languages of all and will be subject to All rights on this document are

will not accept responsibility for damage or malfunctions caused by incorrect installation or improper use of products and Users are therefore recommended to read this manual

in the SAFETY INSTRUCTIONS AND WARNINGS With the aim of improving its products, prior This document conforms to the state of the automation at which it is provided when released for

operator (and will hereinafter be referred to as manufacturer) and the owner of all rights concerning this The Manufacturer’s information required by Machinery Directive 98/37/EC is given below:

The identity plate bearing the information on the Manufacturer of the operator is to the control The plate the type anddate (month/year) of manufacture of the For further information on technical or commercial issues and technician call-out and spares requests, Clients may contact the Manufacturer or area representative from which the product was

Any usage differing from that described above is forbidden. The operator may not be installed or used in potentially explosive environments. The Fitter must ensure that the environment in which the automation is installed is conform to the operator’s temperature range (see Technical Data chap.). The operator is not suitable for use on gates with built-in doors unless the automation is prevented from functioning when the door is open.

gates must conform to current European standards and Directives, including EN 12604 and EN he operator may only be used when in perfect working order and in compliance with the intended use, in the awareness of safety and hazard conditions and in observance with the instructions for installation and

dysfunctions that may pose threats to safety must be eliminated gate must be stable, properly hung and resistant to (it must not bend during opening and closure operator cannot compensate for faulty or incorrectly hung operator may not be used in environments prone to

not use the operator in environmental conditions characterised by harsh atmospheric agents Salty

The Manufacturer declines responsibility for damage or injury caused by non-conformity with the information supplied concerning installation, trial run, use and maintenance contained

The installation, connection, testing, trial run and maintenance of the operator must be performed by a COMPETENT PERSON aided and supervised by a PROFESSIONAL FITTER. Installation requires a practical and theoretical knowledge of mechanics, electronics and electrics, and of sector laws and standards. Amateur installation is strictly forbidden as it does not comply with current standards and laws and therefore does not guarantee the safe operation of the automation. Do not proceed with installation, connection and trial run in the event of doubts or indecision of any kind. This manual must be read carefully and understood before installing the operator. If doubts arise during installation, contact a PROFESSIONAL FITTER or the MANUFACTURER. Do not perform adjustments and/or parameter memorisation before installation is complete and only if you have understood the procedures described in this manual. Only mount the operator on gates that are perfectly aligned with the sliding tracks and are properly hung. A gate that is not correctly aligned or hung can cause serious injury and/or damage to the operator. The Manufacturer declines all responsibility for damage and faults to the operator caused by non-observance of the instructions contained in this

this manual in a safe and easily accessible place so that it can be consulted rapidly when installation, connection, trial run and usage of the operator, observe all applicable accident prevention and safety

the interests of safety and optimal functioning of the operator, only use original spares, accessories, devices and fastening o not perform alterations on any operator device or This type of operation may cause The Manufacturer declines all responsibility for damage caused by products that have been

operator should not be used until the setting up procedure described in the STARTING UP chapter has been hould liquids penetrate inside the operator, disconnect the electricity supply and contact the Manufacturer’s Assistance Service immediately; use of the operator in such conditions may cause hazard the case of faults or problems that cannot be resolved using the information contained in this manual, contact the Manufacturer’s assistance

operator must be stored in closed, dry places, at room temperatures of between –20 and the operator away from sources of heat and naked which could damage it and cause malfunctions, or hazard the operator in a horizontal position, but not resting on the

touch the gate or moving parts when they are in at a safe distance when the gate is in motion: only pass when the gate is completely open and children from playing or standing in the vicinity of the gate or the control organs (radio control), the same precautions should be adopted for disabled persons and

the event of malfunctions (noisiness, jerky movements, suspend the use of the automation immediately: failure to observe this rule may entail serious hazards, risks of accidents and/or serious damage to the gate and the Contact a PROFESSIONAL FITTER and in the meantime use the gate manually by disconnecting the operator (see the OPERATOR RELEASE

order to maintain the operator in conditions, ensure that the operations indicated in the MAINTENANCE chapter are performed at the frequency indicated by a PROFESSIONAL hould liquids penetrate inside the operator, disconnect the power supply immediately and contact the Manufacturer’s Assistance Service; the use of the operator in such conditions may cause hazard a problem arises that cannot be resolved using the information contained in this manual, contact the Manufacturer’s assistance

• Manufacture:• Address: • Telephone: • Telefax: • http: • e-mail:

LIFE home integrationVia Sandro Pertini 3/5 – 31014 COLLE UMBERTO (TV) Italia

+ 39 0438 388592

+ 39 0438 388593www.homelife.it

[email protected]

Page 8: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

8

Instructions and warnings for installation• Before commencing installation read the SAFETY INSTRUCTIONS AND WARNINGS chapter carefully.• The person who installs the operator is responsible for performing risk analysis and regulating the automation’s safety devices consequentially.• Before commencing installation, check whether further devices or materials are needed to complete the automation in order to suit the specific situation in which it will be used.• It is strictly forbidden to motorise a gate that is not already efficient and secure as the automation cannot resolve faults caused by incorrect installation or poor maintenance of the gate.• During installation, make constant reference to harmonised standards EN 12453 and EN12445.• Ensure that the individual devices to be installed are suitable for the automation that one intends to create, paying careful attention to the points raised in the TECHNICAL DATA chapter. Do not proceed if even just one device is unsuitable for the intended use.• Ensure that the place of installation is not prone to flooding, does not contain sources of heat or naked flames, fires or hazard situations in general.• During installation, protect automation components to prevent liquids (e.g. rain) and/or foreign bodies (earth, gravel, etc) penetrating inside.

Preliminary checksBefore commencing installation, the following preliminary checks must be performed:1) The weight and dimensions of the gate must not exceed the limits for use (see the TECHNICAL DATA chap.), if they exceed such limits, the operator may not be installed.2) The gate structure must be suitable for the installation of the operator and conform to current standards.3) The gate’s movement in both opening and closure must be uniform, without points of greater resistance or friction.4) The gate must be properly hung and without risks of derailment, this can be checked by sliding the gate back and forth several times.5) The gate must be hung flat, i.e. it must not move when left in any point of the sliding tracks. Ensure that the gate does not bend or deviate from its course during movement.6) The gate must be perfectly flat in to the plane to which the sliding track is fixed, in order to prevent irregular movement during operation.7) The limit switches must be sufficiently sturdy and there must be no risk of derailment should the gate collide with the limit switches.8) The operator installation area must not be prone to flooding and therefore it may not be installed in potholes, trenches, dips in the ground, etc.9) The cement base on which the operator must be installed must be adequately solid and compact.

MAINTENANCE INSTRUCTIONS AND WARNINGS• Once the automation has been tested, the parameters set must not be altered. If further adjustments (e.g. alterations to the voltage value) are made, all the checks required for testingand compliance with standards must be repeated.• The Manufacturer declines responsibility for damage or injury caused by non-compliance with the information provided in this manual and the safety instructions provided below.• The Manufacturer declines all responsibility for damage and malfunctions deriving from non-compliance with the maintenance instructions.• In order to keep the operator efficient and safe, follow the cleaning, checking and routine maintenance procedures as described in this manual. This is the owner’s duty.• Any checking, maintenance or repair work must be conducted by a PROFESSIONAL FITTER• Always switch of the electricity supply in the event of malfunctions, breakdowns and before any other operations in order to avoid the gate from being activated.• The owner is not authorised to remove the operator lid as it contains live parts.• If the power cable is damaged, it must be replaced by the Manufacturer or its technical Assistance service or in any case a person with a similar qualification in order to avoid risks.• The owner is NOT authorised to use the programming keyboard.• Use original pare parts, accessories and clamping material only.• Do not perform technical or programming modifications on the operator. Operations of this type may cause malfunctions and/or risk of accidents. The Manufacturer declines responsibility for damage deriving from modified products.• In the event of intervention of automatic or fuse switches, before restoring function conditions identify and eliminate the fault. Request the intervention of a PROFESSIONAL FITTER.• If a fault that cannot be solved following the information contained in the present manual, contact the manufacturer’s assistance service.• All maintenance, repair or replacement of parts must be recorded in the maintenance log, which is SUPPLIED AND INITIALLY FILLED IN BY THE FITTER.• Inspect the installation frequently to ensure that there are no signs of mechanical unbalance, wear or damage to the wires and assembled parts: no not use the automation until any necessary repairs or adjustments have been made.Cleaning the automation

ATTENTION:• Never wash the operator using water sprays or washing devices.• Do not use corrosive substances, solvents, thinners or spirit to clean the operator.• Switch off the electricity supply to the operator before cleaning.a) Automations are almost always installed outdoors and therefore they are subject to climatic variations and exposed to the elements, which transport debris that may cause problems.b) The entire area in which the automation is installed must be kept clean to avoid malfunctions and/or faults.c) Keep the track on which the gate runs clean by sweeping stones, gravel, and mud off using a broom.d) Clear the area in which the operator is installed to prevent stones, gravel, mud, dry leaves, pine needles etc. from accumulating around the pinion, thus causing damage to the pinion, rack, limit switch and operator. Routine maintenanceEvery six months contact a PROFESSIONAL FITTER to perform the following operations.• A series of opening and closing checks using radio controls and selectors, using all the system’s components (photocells, flashing light, etc.). Ensure that the operator performs the desired action.• Grease the operator’s nut-screw-bushing unit and the gate hinges.• Repeat the series of tests envisaged for operator testing (see INSTALLATION MANUAL – Testing and first run chapter.

DEMOLITION AND DISPOSALACER operators are constituted by various materials, which implicates different disposal modes. Materials such as aluminium, plastic, electric cables, etc., can be recycled; batteries, electronic cards, etc. must be disposed of.

ATTENTION:• The disposal of batteries, cards and electric and electronic components must comply with legislation and local regulations on toxic, harmful and polluting substances.• Disconnection from the main supply must always be performed by a qualified electrician using suitable equipment.

Page 9: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

9

SPECIFIC DESCRIPTION ACER

Page 10: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

10

5RI2310000 ACER 5RI2330000 AC4R-AC6R-AC4-AC6-AC8 AC12-AC12R 5RI2350000 AC8A 24

5RI2370000 AC4RM-AC6RM-AC4M-AC6M AC8M-AC12M-AC12RM 5RI2380000 AC8A 24M 5RI2340001 AC3RM24DL-AC6RM24DL

5RI2410000 AC8-AC8R

5RI2420000 AC4R-AC4R 5RI2430000 AC6R-AC6R

5RI2440001 AC3RMDL 5RI2450000 AC4 24 5RI2460000 AC6 24 5RI2470000 AC8 24

5RI2480000 ACER R 5RI2490000 ACER RM 5RI2500000 ACER

5RI2510000 AC4-AC4R 5RI2520000 AC8-AC4 24-AC6 24-AC8 24 AC3RM24DL-AC6RM24DL AC6-AC6R

5RI2530000 ACER 5RI2550000 AC8-AC4 24-AC6 24-AC8 24AC6-AC12-AC12R-AC3RM24DL

5RI2560000 AC4-AC4R

5RI3440000 AC12-AC12R 5RI3450000 AC6RM24 DL

Page 11: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

11

5RI2670000 AC4R-AC6R-AC4 24P 5RI268000 ACER 5RI2690000 AC4-AC6-AC8 5RI2700000 AC4A 24-AC6A 24 5RI2720000 AC8A 24-AC3/6RM24DL 5RI2730000 AC4R-AC6R-AC8R-AC12R

5RI2600000 AC4-AC6-AC4R-AC6R-AC4A24AC6A24-AC6RM24DL

5RI2610000 AC3RM24DL 5RI2620000 AC8 24

5RI2630000 AC4-AC6-AC8-AC8R-AC4RACA 24-AC6 24-AC6RAC6RM24DL

5RI2640000 AC8A 24-AC8A 24M

5RI2570000 ACER 5R2580000 ACER 5RI2590000 ACER

5RI2620000 AC8-AC12-AC8R-AC12R

5RI2650000 AC3RM24 DL

5RI268000 ACER SIMPLY

Page 12: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

12

Declaration of conformity

under Directive 98/37/EC, appendix II, part B (Manufacturer’s Declaration of CE Conformity)

LIFE Home IntegrationVia S.Pertini 3/5

31014 COLLE UMBERTO (TV)

declares that the following product:

ACER operator for sliding gates

Satisfies the essential requisites established in the following directives:

• Low voltage directive 73/23/EEC and subsequent amendments,• Electromagnetic compatibility directive 89/336/EEC and subsequent amendments,• Radio and telecommunications equipment directive 1999/5/EC and subsequent amendments.

and satisfies the following standards:

• EN 12445:2000 Industrial, commercial and garage doors and gates – Safety in the usage of motorised doors – testing methods• EN 12453: Industrial, commercial and garage doors and gates – Safety in the usage of motorised doors – Requisites• EN 60204-1:1997 Machinery safety – Electric equipment of the machine – Part 1: general rules.• EN 60950 Information technology equipment - Safety - Part 1: General requisites• ETSI EN 301489-3:2001 Electromagnetic compatibility for radio equipment and appliances.• EN 300220-3:2000 Radio equipment and systems – short band devices – Technical characteristics and testing methods for radio apparatus with a frequency of 25 to 1000 MHz and powers of up to 500mW.

The Manufacturer also declares that it is not permitted for the abovementioned components to be used until such time as the system in which they are incorporated is declared conform to directive 98/37/EC.

COLLE UMBERTO ____________ Name of Signor: MICHELE RUI

Position: PRESIDENT

Signature:

Address: Factory 19, 5 Lyn Parade, Prestons NSW 2170

Telephone: + 61 2 9607 4100Telefax: + 61 2 9600 8882 http www.homelife.net.au

Page 13: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

RG1R UNI DLRG1R DL

CONTROL UNIT FOR AUTOMATIONS FITTED WITH 230 V MOTORSINSTRUCTIONS AND WARNINGS FOR INSTALLATION, USE AND MAINTENANCE.

Page 14: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

1

5RI122000

2

2AS3710000

Components and devices of a typical automation.

STANDARD INSTALLATION

Page 15: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

RG1 DL

V0V21V42M

OCON CN

RX

V0V21V42

TX

612

1516

12

1719

14

16

1

2

3

4

5

6

18

19230 Vdc 40w max

SPL

24 Vdc 3w max

6

7

10

CN

ON

MO

C

SKANT - SKANX

ROT

OM

ROTICAPAC

REDOCNE

SEHCTIWS

TIMIL

230V0 16 24

KCALB

EGNAR

O

KCALB

KCALBEULB

EULBN

WORB

NEERG

DER

C. N.

PHOTO1

PHOTO

STEP

CLOSE

OPEN

STOPCOMMANDS COMMON

RG58-50ohm

AERIAL

N.C.

N.O.

N.O.

N.O.

N.C.

N.C.

12

6

789

101112

141516

171819

L1 L1

L2230 Vac

24 Vac 3W max INDICATOR LIGHT

EXIT 24 Vac 200 mA max

230 Vac 25W max

230 Vac 40W max COUTESY LYGHT

FLASHING

ROT

OM

ROTICAPAC

230V0 16 24

KCALB

EGNAR

O

KCALBEULB

EULBN

WORB

NEERG

C. N.

RG1 UNI DL

ELECTRICAL SYSTEM

L7

L8

L9L10

L11L12

Page 16: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

PHASE 2

PROGRAMMING THE TRAVEL

PHASE 1

PROGRAMMING THE CONTROL UNIT

DEFINING THE STOP PLATES

Ensure that the automation’s opening and closure stop plates have been fixed.

1 2

FFO

230V

OFF

1 3ON

ON

230V

2

OFF

230V

N.B. In case just one motor is utilised, choose from Menu Options 2 “Activate single motor” and connect on terminals 20-21-22

b) Press for 5 seconds, the 5 LEDs will light and then start flashing.c) Press and the gate starts rolling, if it opens press again to invert the movment. The first activated limit switch has to be the one of the closing system.Finished the two flash programming green LED will be lit and a steady light led the two reds. If the result was not satisfactory, you can perform a programming manual to determine the lags. See Section 3.3.4

a) Position the leaf gates at 45°.

STOP PLATES - Ensure that the open and close stop plates are set to the correct position

SINGLE MOTOR - In the case of a single gate installation connect the motor into terminals 20-21-22 before programming enter the options 2 menu and select single motor activated (led 4 on)

AUTOMATIC PROGRAMING

POWERING UP - With the power off, hold the start button down ,reinstate the power supply and release the button the red led’s will fl ash

Secs

PHASE 2

PROGRAMMING THE TRAVEL

a) Press start or 5 seconds, the 5 LEDs will light and then start flashing.b) Press and the gate starts rolling,

if it open press again o the movment. The first activated limit switch has to be the one of the closing system.

The automation will perform, in sequence, a closure (1),an opening (2), a closure (3).

Once programming is complete, the two green LEDs willflash and the red led ( ) will light.

Should the result obtained not be satisfactory, repeat the whole process.

SELOSC SNEOP

SESOLC

1 2 3

Ensure gate is in central position (half open) and manual release is locked before proceeding

Energy Saving In order to save energy, we have introduced the function

Energy Saving. 10 minutes after the end of programmation of the control board, the LED of the keyboard go out and it is no more possible to use the control board. To get the control board working again, switch it off and on.

PROGRAMMING THE TRAVEL

a) Press start or 5 seconds, the 5 LEDs will light and then start flashing.b) Press and the gate starts rolling,

if it open press again o the movment. The first activated limit switch has to be the one of the closing system.

The automation will perform, in sequence, a closure (1),an opening (2), a closure (3).

Once programming is complete, the two green LEDs willflash and the red led ( ) will light.

Should the result obtained not be satisfactory, repeat the whole process.

N.3 Not for RG1R DL UNI version.

Page 17: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

1 WIRING AND CONNECTIONS• Before commencing wiring and connection work, read the SAFETY INSTRUCTIONS AND WARNINGS and INSTALLATION INSTRUCTIONS AND WARNINGS chaps carefully. • All wiring and connection operations must be carried out with the control unit disconnected from the electricity supply. If the disconnection device is not in view, display a sign reading: “ATTENTION: MAINTENANCE WORK IN PROGRESS”.

1.1 Control unit connectionsTerminals Description (SEE WIRING DIAGRAM on page 2A)

AERIAL: aerial sheath inputUse a RG58- 50ohm cable.

AERIAL: aerial cable input

1

2

6

6 - 8

6 - 7

COMMAND AND PHOTOCELL COMMON: for stop, open, close, step, photo and +12V inputs.

OPEN: NO input, commands gate opening.

16 - 15 USCITA 24 Vac: per alimentazione di vari dispositivi, 200 mA max.

19 FLASHING OR COURTESY LIGHT POWER SUPPLY COMMON

16 COMMON, INDICATOR LIGHT, 24 V ac OUTPUT

6 - 9 CLOSE: NO input, commands gate closure.

STOP: programmable NC input, commands gate stoppage.Can be connected to safety devices such as an emergency stop button.When the command is released automatic closure never occurs and a new movement command must be given.Leave jumpered if no device is envisaged.

6 - 11 PHOTO1: programmable NC input for photocells or safety devices. Causes gate stoppage during both opening and closure.Motion resumes during opening when the photocell or safety device is disengaged.Leave jumpered if no device is envisaged.

6 - 12 PHOTO: NC input for photocells or safety devices. Does not intervene during gate opening; during closure causes reversal of gatemotion until open.Leave jumpered if no device is envisaged.

19 - 17 FLASHING LIGHT: 230 Vdc 25W max output for connecting a SPLENDOR SRL flashing light characterised by three flashing modes:1) slow during door opening; 2) fast (flashing times halved) during closure. 3) three flashes and a pause to indicate a fault state ortravel identification.

COURTESY LIGHT: 230 Vdc 40W max. output for connecting a courtesy light that switches on at the start of each movement (openingor closure and is characterised by an fix for 30 sec.)

16 - 14 INDICATOR LIGHT: 24Vac 3W max output, for connecting an indicator light that copies the function of the flashing light during movementand that remains on when the gate is open.

19 - 18

6 - 10 STEP: NO input, commands gate movement according to the following cycles:SEMI-AUTOMATIC MODE: Open, stop, close, stop.Automatic mode: open, pause, close, pause.

230Vac 50 Hz power supplyL 2L 1N.C. = normally closed contact – NO = normally open contact

PHASE 3AACKNOWLEDGMENT OF THE TOTAL OPENING RADIOCOMMAND

a) Press , the green led (SX) will light and the red one A will switch on.b) Hold down the key (P1) on the radio control until all five LEDs light .c) Wait 25 seconds or press two times again to quit.

ACKNOWLEDGMENT OF THE PEDESTRIANS’ OPENING RADIOCOMMAND

a) Press , two times, the green (left) and the red (right) led switch on.b) Keep the button (P2) pushed untile all the five leds switch on

.

The automation is now programmed.

SEMIAUTOMATIC mode is enabled: by giving the ‘STEP’ command, the automation changes movement following the sequence 1 – OPEN 2 – STOP 3 –CLOSE 4 – STOP. Automatic re-closure is not enabled.

Once programming is complete, the key acts as a STEP command.

P1 P2

1

PROGRAMMING RADIO TRANSMITTERSPROGRAMMING RADIO TRANSMITTERS TOTAL OPENING COMMANDTOTAL OPENING COMMAND•• Press the radio icon button (top left) once thePress the radio icon button (top left) once the

left green led will light and the first (L to R) ofleft green led will light and the fi rst (L to R) of the top 5 led’s will light.the top 5 led’s will light.

•• Hold down the button on the transmitter thatHold down the button on the transmitter that you want to perform a total opening of theyou want to perform a total opening of the gates. Once the top 5 led’s light the trans-gates. Once the top 5 led’s light the trans-mitter has been coded.mitter has been coded.

•• To exit wait 25 seconds or push the radio iconTo exit wait 25 seconds or push the radio icon button twice.button twice.

PEDESTRIAN OPENING COMMANDPEDESTRIAN OPENING COMMAND (ACTIVE ON MOTOR 1)(ACTIVE ON MOTOR 1)•• Press the radio icon button (top left) twice.Press the radio icon button (top left) twice.

The left green led will light and the second (LThe left green led will light and the second (L to R) of the top 5 led’s will light.to R) of the top 5 led’s will light.

•• Hold down the button on the transmitter thatHold down the button on the transmitter that you want to perform a pedestrian opening ofyou want to perform a pedestrian opening of the gates. Once the top 5 led’s light the trans-the gates. Once the top 5 led’s light the trans-mitter has been coded.mitter has been coded.

Once programming is complete the START button acts as a step commandOnce programming is complete the START button acts as a step command

Page 18: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

1.1.1 Control unit wiring diagram of the lower part

Terminals Description

BLACK CABLE COMMON ELECTRONIC AND AUXILIARY POWER SUPPLY

GEAR MOTOR RELEASE SWITCH

0

BLACK CABLE-

RED CABLE

DARK BLUE

GREEN

STOP PLATE and ENCODER

TRANSFORMER POWER SUPPLY

+

BLACK

A

B

C

D

E

16

CLOCKWISE ROTATION

COMMON

BROWN CABLE

BLUE CABLE

ANTI-CLOCKWISE ROTATION

CAPACITOR

230Vac MOTOR OUTPUT

WHITE CABLE

24

B1

ORANGE CABLE

COMMON

FC1

FC2

ATTENTION: the connections pre-wired by the manufacturer may not be altered under any circumstances.

1.1.2 Indicator LEDs

There is a row of 6 LEDs on the right hand side of the board, under the terminals.These LEDs are lit when the corresponding signal is present.For N.C. inputs STOP, PHOTO1 and PHOTO, the corresponding LEDs L7, L11 and L12 are normally on.For the N.O. inputs OPEN, CLOSE and STEP, the corresponding LEDs L8, L9 and L10 will be switched off. These LEDs therefore indicate any malfunction of the connected devices.

L7

L8

L9L10

L11L12

Page 19: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

• Use the power supply cable provided with the operator only.• The power cable provided may not be extended or shortened• All wires must be unsheathed as little as possible (6mm at the most), as close as possible to the connection terminals, in order to prevent accidental contact with live parts should the cables disconnect from the terminals.• Do not pre-seal cables to be fastened to the terminals using screws.• If it is possible that wires subject to voltage higher than 50 Volt RMS and very low voltage safety wires may come into contact with one another, wires with voltage higher than 50 volt RMS must be insulated with a sheath; or the very low voltage safety wire must have an insulating sheath at least 1mm thick.• No external connection cables must be of the flat twin tinsel cord type.

1.2.1 Setting up the electric system and connection to the mains supply

This manual does not describe how the electrics system should be prepared for connection to the mains. It does, however, give the following warnings:• The electricity supply line must be installed and connected by an authorised electrician or professional fitter.• The electricity supply must be adequately protected against short circuits and static discharge. • The power supply network must contain an omnipolar circuit breaker with a contact opening distance equal to or greater than 3.5 mm that assures the complete disconnection of the power supply.

1.2.3 Control unit connections

Fitters must make the connections of the 230 Vac 50 Hz electricity supply, and the various automation devices. Connections between the control unit, motor, encoder and transformer have already been performed by the Manufacturer.

• Once the connections to the control unit have been made, the Fitter must use bands to join adjacent wires into groups of 2, 3 or 4 in order to prevent them coming away from the terminal board: bands must be attached as close as possible to the terminals, no more than 10mm away, taking care not to damage wire insulation. No cable may remain unpaired. • The bands are only for unsheathed cables (sheathed cables are held in place by the sheath).• Pay careful attention not to pair wires with voltages higher than 50 Volt RMD with lower voltage wires. • The wiring performed internally by the manufacturer is already equipped with clamping bands.

Internal button panel.

Sensitive strip (signal)

3x1 mm2 cable

2x1 mm2 cable

ATTENTION: the cables used must be suited to the type of installation. It is the Fitter ’s responsibility to choose appropriate material.

Pos. Type of cableConnection

Electricity supply line

Internal button panel.

Sensitive strip (signal)

Power supply

Flashing light

Radio aerial

Tx Photo

Rx Photo

Selector

3x1,5 mm2 cable

Cable supplied with Schuko socket

Screened RG58 50 Ω cable

4x1 mm2 cable

2x1 mm2 cable

2x1 mm2 cable

3x1 mm2 cable

3x1 mm2 cable

2x1 mm2 cable

1.2 List of electric cables

The cables needed may vary depending on the installation and type and quantity of devices installed.

The cables used in the installation must be IEC 60335 compliant.

FUSESTwo internal Fuses

a)F1 protects the secondary 24v supply againsttransformer overloadTechnical: Mini fuses 5x20 T10 A certifi cated by IEC 60127 or EN 60127

b)F2 protects the primary 24v supply against motor overloadTechnical: Mini fuses 5x20 T1 A certifi cated by IEC 60127 or EN 60127

Page 20: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

2 RADIO CONTROL MANAGEMENTThe control unit is fitted with a built-in radio receiver with a 1 channel 1000-code memory, with a 433.92 MHz frequency with LI FE Rolling Code and Auto code encoding.

2.1 Resetting an initialised radio control

Pa) Press , for 5 seconds, the green LED will light and then start flashing.

b) Hold down the key on the radio control until all five LEDs light , the remote control has been reset.

c) Wait 25 seconds or press again to quit.

2.2 Resetting all identified radio controls

a) Press for 5 seconds, the green LED will light and then start flashing.

b) Press for 5 more seconds , the first two and the last two LEDs will flash alternatively

. After alternate flashing all initialised remote controls are reset.

c) Attendere 25 secondi o premere nuovamente per uscire.

DELETING A SINGLE RADIO TRANSMITTERDELETING A SINGLE RADIO TRANSMITTER•• Press the radio icon button (top left) for 5 Press the radio icon button (top left) for 5

seconds. The left green led will light and seconds. The left green led will light and start fl ashing.start fl ashing.

•• Hold down the button on the transmitter you Hold down the button on the transmitter you wish to delete until all the top 5 led’s light. wish to delete until all the top 5 led’s light. The transmitter has been deletedThe transmitter has been deleted

•• To exit wait 25 seconds or push the radio To exit wait 25 seconds or push the radio icon button once.icon button once.

Secs

Secs Secs

DELETING ALL RADIO TRANSMITTERS.DELETING ALL RADIO TRANSMITTERS.•• Press the radio icon button (top left) for 5 Press the radio icon button (top left) for 5

seconds. The left green led will light and seconds. The left green led will light and start fl ashing.start fl ashing.

•• Press for fi ve more seconds, the fi rst two and Press for fi ve more seconds, the fi rst two and the last two led’s will fl ash alternatively. All the last two led’s will fl ash alternatively. All transmitters have been deletedtransmitters have been deleted

•• To exit wait 25 seconds or push the radio To exit wait 25 seconds or push the radio icon button once.icon button once.

Photo Input Photo Input Opening - No effect, continues to open. Opening - No effect, continues to open. Closing - Re opens.Closing - Re opens.

Photo1 input Photo1 input Opening - Stops and continues opening when Opening - Stops and continues opening whenphotocells are cleared.photocells are cleared.Closing - Stops and then reopens when photocells Closing - Stops and then reopens when photocells are cleared.are cleared.

Photo2 input Photo2 inputOpening - Stops and recloses slightly. (It will close Opening - Stops and recloses slightly. (It will close fully after a pause time if set)fully after a pause time if set)Closing – No effect.Closing – No effect.

DELETING RADIO CONTROL TRANSMITTERS

PHOTOCELL FUNCTIONSPHOTOCELL FUNCTIONS

Page 21: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

3.1.2 Automatic reclosure

Automatic reclosure is activated after a preset PAUSE TIME.

In this mode, by pressing the ‘STEP’ key, the automation changes its motion according to the sequence 1 – OPEN 2 – PAUSE 3 – CLOSE 4 - PAUSE;for example, if the automation is opening and one selects the step command on the remote control, the automation stops in pause; conversely, if the automation is closed, when the step command is given it opens. PAUSE TIME is intended as the pause time before automatic re-closure.

Press and to set the various PAUSE TIME values.

Wait 25 seconds or press again to quit.

OPEN » PAUSE » CLOSE » PAUSE

Press the green LED (RIGHT) switches on:• if none of the LEDs is switched on, automatic reclosure is not enabled, to enable it press ;• if at least one of the LEDs is switched on, automatic reclosure is enabled, to deactivate it press until all the LEDs switch off.

LEDS ON PAUSE TIMEAUTOMATIC RE-CLOSURE IS NOT ENABLED

5 s

10 s30 s

60 s

120 s

3.1.3 OPTION MENU 1

Press to enter OPTION menu, press repeatedly to select further options, the flashing led shows the position, by pressing button + the function is activated (red led on), by pressing button– the function is desactivated.

LEDS ON OPTIONS 1

NO FUNCTIONS ACTIVATED

Block of appartment: Step-by-step in opening

Modifies the function in: OPENING-STOP-CLOSING-STOP

Automatic 2 Steps: OPENING - CLOSURE

Input Stop becomes PHOTO2, the photocells intervenes in opening with brief invertion.

CLOSING PASSING BY: passing by the photocells (PHOTO), the automation closes after 5”.

5”

LEDS

Preflashing

Soft Start

OPTIONS 2

OPTION MENU 2

Press the option button (bottom right) for 5 seconds, then press in sequence to scroll through the options as shown byPress the option button for 5 seconds, then press in sequence to scroll through the options as shown by the five led’s at the top. The flashing of the led indicates the option selected. The + button is used to select the functionthe fi ve led’s at the top. The fl ashing of the led indicates the option selected. The + button is used to select the function indicated by the led staying lit. The – button will de select the option. To exit continue to scroll through to option 5.indicated by the led staying lit. The – button will de select the option. To exit continue to scroll through to option 5.

5 Secs

Lightning in pause

NO FUNCTIONS ACTIVATED

* Electronic heater

* By activating the heater, the entry becomes entry PHOTO1 THERMOSTAT.When the contact is closed, the heater is on, in the opposite with the contact open the heater is turned off.

OPTION MENU 2

5

Exclusion of decelerationExclusion of deceleration

Page 22: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

3.2.3 Force

The force function regulates the thrust and the speed of the automation.

Wait 25 seconds or press again to quit.

Press the red LED (LEFT) switches on.Press and to set the various force values.

Minimum

Maximum

LEDS ON FORCE VALUE

3.2.4 Obstacle detection

The automation is fitted with an obstacle detection system: the automation inverts its movement when it strikes an obstacle during the opening and closure phases.Sensitivity regulation consists in greater or lesser rapidity in response to the obstacle.1) During the closure phase, if the control unit identifies an obstacle, the automation inverts motion and performs complete opening. If the obstacle is detected 3 times consecutively, the automation stops in a completely open position awaiting a command.2) If the control unit identifies an obstacle, the automation performs a short reversal of motion, before stopping awaiting a command.

Wait 25 seconds or press again to quit.

Press for 5 seconds, the red LED (LEFT) will light and then switch off.Press and to set the various obstacle detection values.

MINIMUM

MAXIMUM

LEDS ON OBSTACLE DETECTION NO OBSTACLE DETECTION

FORCEFORCE•• Press the force button (bottom left) and thePress the force button (bottom left) and the

left red led switches on.left red led switches on.•• Press the + and - buttons to set the forcePress the + and - buttons to set the force

values.values.•• The force value is indicated by the 5 led’s atThe force value is indicated by the 5 led’s at

the top of the board.the top of the board.•• Wait 25 seconds or press the force buttonWait 25 seconds or press the force button

again to quitagain to quit

OBSTACLE DETECTIONOBSTACLE DETECTIONThe automation is fitted with an obstacle detection system. The automation inverts its movement when it strikes anThe automation is fi tted with an obstacle detection system. The automation inverts its movement when it strikes an obstacle during the opening and closing phases.obstacle during the opening and closing phases.1. During the closure phase, if the control unit identifies an obstacle, the automation inverts the motion and1. During the closure phase, if the control unit identifi es an obstacle, the automation inverts the motion and performs a complete opening. If the obstacle is detected 3 times consecutively, the automation stops in the openperforms a complete opening. If the obstacle is detected 3 times consecutively, the automation stops in the open position awaiting a command.position awaiting a command.2. If the control unit identifies an obstacle on opening, the automation performs a short reversal of motion,2. If the control unit identifi es an obstacle on opening, the automation performs a short reversal of motion, before stopping awaiting a command.before stopping awaiting a command.

•• Press the force button (bottom left)for 5Press the force button (bottom left)for 5 seconds and the left red led switches on andseconds and the left red led switches on and then goes off.then goes off.

•• Press the + and - buttons to set the obstaclePress the + and - buttons to set the obstacle detection values.detection values.

•• Wait 25 seconds or press the force buttonWait 25 seconds or press the force button again to quitagain to quit

MINIMUM

MAXIMUM

LEDS ON OBSTACLE DETECTION NO OBSTACLE DETECTION

secs

3.2 Functions

3.2.1 Courtesy light

The courtesy light function switches a light on during any automation movement.The light remains on after the last manoeuvre for a 30-second period.

3.2.2 Deceleration in opening and closure

The automation decelerates in the final stretches of opening and closureo.

Page 23: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

4 TROUBLESHOOTINGThis chapter describes the most frequently encountered problems with the solutions for resolving them. In certain cases, it is explicitly envisaged that operations be performed by a professional fitter: these indications must be followed in order to avoid exposing oneself to serious risks.

4.1 Malfunctions indicated on the control unit

The malfunctions detected by the control unit are indicated through the lighting of the 5 LEDs on the display.The control unit also indicates the presence of a fault on the exterior through the flashing lamp: three flashes and a pause, if the motor is in motion.

N.B. if the problems persist it is absolutely necessary to call the assistance service.

SIGNAL MALFUNCTION ACTION POSSIBLE SOLUTION

Closure stop plate The control intervenes blocking the operator and switching it to dead man mode (persistent commands) and at reduced speed.

The control intervenes locking the automatism. Try to give further commands. If the problempersists or arises frequently it is necessaryto call the assistance service.

Try to perform a complete two-way travel (atreduced speed and with persistent commands).If the problem persists or arises frequently it is necessary to call the assistance service.

N.B.Obstacle detection sensitivity regulation is described in the ADJUSTMENTS chap.

Check the phototest setting and try to give another command to repeat the phototest. If the problem persists or arises frequently it is necessary to call the assistance service.

N.B.In this situation release the automation and call technical assistance.

The check intervenes inverting motion, i.e. performingan opening, and when it reaches the end of the stroke, it awaits a new signal (even in condominiummode); however, if the system is opening, it intervenesinverting the motion for a short stretch (3/4 cm) and then stopping until such time as new commandsare given.

The check intervenes keeping the system in stop conditions.

The control intervenes by passing the system tothe operation condition with dead man commandand reduced speeds.

Opening stop plate

Encoder

Obstacle

Fotocélulas

This class includes various incorrect andunsafe operation situations.

Page 24: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

5 GENERAL INFORMATIONIt is strictly forbidden to copy or reproduce this instruction manual without written permission to do so and subsequent verification by LIFE home integration. Translation into other languages of all or part of the manual is strictly forbidden without previous written authorisation from and subsequent verification by LIFE home integration. All rights on this document are reserved.LIFE home integration will not accept responsibility for damage or malfunctions caused by incorrect installation or improper use of products and Users are therefore recommended to read this manual carefully LIFE home integration will not accept responsibility for damage or malfunctions caused by the use of the automation together with the devices of other manufacturers; such action will render the warranty void.LIFE home integration will not accept responsibility for damage or injury caused by non-compliance with the installation, set up, maintenance and use indications contained in this manual and the safety instructions described in the SAFETY INSTRUCTIONS AND WARNINGS chapter.With the aim of improving its products, LIFE home integration reserves the right to bring about alterations to them at any time, without giving prior notice. This document conforms to the state of the automation at which it is provided when released for sale.

5.1 INFORMATION ON THE MANUFACTURERLIFE home integration is the manufacturer of the RG1 24DL control unit (referred to for short as “control unit”) and the owner of all rights concerning this document.. The Manufacturer’s information as required by Machinery Directive 98/37/EC is given below:

• Manufacturer: LIFE home integration • Address: Via I Maggio, 37 – 31043 FONTANELLE (TV) Włochy • Telephone: + 39 0422 809 254• Fax: + 39 0422 809 250• http: www.homelife.it• e-mail: [email protected]

The identity plate bearing the information on the Manufacturer is fixed to the control unit. The plate specifies the type and date (month/year) of manufacture of the product.For further information on technical and/or commercial issues and technician call-out and spares requests, Clients may contact the Manufacturer or area representative from which the product was purchased.

5.2 INTENDED USE• The RG1 UNIR DLcontrol unit has been exclusively designed to command 1 electromechanical operator with 230 Vac power supply destined to motorising ‘residential’ type leafs. Any usage differing from that described above is forbidden. • The control unit may only be used with other LIFE products.• The manufacturer declines all responsibility for damage caused by improper use. All risks are the fitter’s responsibility and the warranty shall be rendered void.• The control unit may not be installed or used in potentially explosive environments.• Motorised gates must conform to current European standards and Directives, including EN 12604 and EN 12605.• The control unit may only be used when in perfect working order and in compliance with the intended use, in the awareness of safety and hazard conditions and in compliance with the instructions for installation and use.• Any dysfunctions that may pose threats to safety must be eliminated immediately.• The control unit may not be used in environments prone to flooding.• Do not use the operator in environmental conditions characterised by harsh atmospheric agents (e.g. salty air).

6 SAFETY INSTRUCTIONS AND WARNINGS

6.1 General instructions and warnings• This manual is designed for use by PROFESSIONAL FITTERS only. Installation of the control unit requires practical and theoretical knowledge of mechanics, electrics and electronics as well as current sector legislation and regulations.• Once the control unit has been installed, it is forbidden for users to perform any operation on the control unit even following the instructions in this manual, which, as mentioned previously, are intended for use by qualified personnel only.• Fitters must operate in compliance with the following: law 46/90, directive 98/37/EC, 73/23/EEC, 89/336/EEC and subsequent amendments. He/she must also make constant reference to harmonised standards EN 12453 and EN 12445.• The indications given in this manual must always be observed when installing, connecting, adjusting, testing and setting the control unit. The Manufacturer declines all responsibility for damage or injury caused by non-observance of the instructions contained in this manual.• The Manufacturer declines all responsibility for damage and faults to the control unit caused by non-observance of the instructions contained in this manual.• Keep this manual in a safe and easily accessible place so that it can be consulted rapidly when necessary.• During installation, connection, trial run and usage of the control unit, observe all applicable accident prevention and safety regulations.• In the interests of safety and optimal functioning of the control unit, only use original spares, accessories, devices and fastening apparatus.• Do not perform alterations on any control unit device or component. This type of operation may cause malfunctions. The manufacturer declines all responsibility for damage caused by products that have been modified.• Should liquids penetrate inside the control unit, disconnect the electricity supply and contact the Manufacturer’s Assistance Service immediately; use of the control unit in such conditions may cause hazard situations.• In the event of long periods of inactivity, in order to prevent the leakage of harmful substances from the battery (optional), it should be removed, stored in a dry place and recharged periodically.• In the case of faults or problems that cannot be resolved using the information contained in this manual, contact the Manufacturer’s assistance service.

6.2 Storage instructions and warnings• The Manufacturer declines all responsibility for damage and faults to control unit functioning caused by non-compliance with the storage instructions given below.• The control unit must be stored in closed, dry places, at room temperatures of between –20 and +70°C and raised off the ground.• Keep the control unit away from sources of heat and naked flames, which could damage it and cause malfunctions, fires or hazard situations.

7 INSTALLATIONATTENTION: Important safety instructions. Follow all instructions carefully, incorrect installation may cause serious injury.Before commencing installation we highly recommend reading the instructions and warnings contained in this manual carefully (see the SAFETY INSTRUCTIONS AND WARNINGS Chap) and observing the instructions it contains.

7.1 Instructions and warnings for installations• Before commencing installation read the. SAFETY INSTRUCTIONS AND WARNINGS chapter carefully• The PROFESSIONAL FITTER who installs the control unit is responsible for performing risk analysis and regulating the automation’s safety devices consequentially.• The Fitter must check that the temperature range declared on the control unit is suited to the place in which the device is installed.• Any normally open/off buttons installed for the activation of the operator must be positioned so that they are within view of the gate but distant from moving parts. Unless said commands operate using keys, they must be positioned at a minimum height of 1.5m and not accessible to unauthorised persons.• During installation, make constant reference to harmonised standards EN 12453 and EN12445.• Ensure that the individual devices to be installed are compatible with the RG1 UNIR DL control unit. Do not proceed if even just one device is unsuitable for the intended use.• Ensure that the place of installation of the central unit is not prone to flooding, does not contain sources of heat or naked flames, fires or hazard situations in general. • During installation, protect control unit components in order to prevent liquids (e.g. rain) and/or foreign bodies (earth, gravel, etc) penetrating inside.• Connect the control unit to a power supply line created in compliance with current regulations and earthed and fitted with a power supply sectioning switch.• Wrapping materials must be disposed of in compliance with local regulations.• Wear protective goggles when making holes for clamping.In the event of work at heights of over 2m from the ground, for example for the installation of the indicator lamp or aerial, fitters must be equipped with ladders, safety harnesses, protective helmet, andall other equipment required by law and the standards governing this kind of work. Refer to Directive 89/655/EEC amended by 2001/45/EC.

Page 25: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

8 TESTING AND TRIAL RUN• The testing and trial run must be performed by a COMPETENT PERSON supervised and aided by a PROFESSIONAL FITTER. It is the responsibility of the person who tests and sets up the automation (of which the control unit is a part) to perform the checks required in accordance with the risks existing and to check conformity with the relevant legislation and standards, in particular with EN standard 12445, which governs the methods for performing trials on gate automations and EN standard 12453 that specifies the performance requisites concerning safety of use.• The testing and trial run are the most essential phases of installation for guaranteeing maximum operating safety.• The checks and procedures for testing may also be used for routine checks on the automation and its devices. • The automation may only be tested if a non-hazardous force tolerance has been set. Force tolerance must be adjusted to a minimum value so as to exclude the danger of injury during closure.• Adjust the maximum force in line with EN standard 12445.• Never touch the gate or moving parts when they are in motion.• Remain at a safe distance when the gate is in motion: only pass when the gate is completely open and immobile.• In the event of malfunctions (noisiness, jerky movements, etc.) suspend the use of the automation immediately: failure to observe this rule may entail serious hazards, risks of accidents and/or serious damage to the gate and the automation.• Always remember that the following residual risks exist when the gate is in movement: a) impact and crushing against the main closure edge (against the single leaf or between the two leaves); b) impact and crushing in the opening area; c) cshearing between the moving and the fixed guides and support during movement; d) mechanical risks caused by movement.

8.1 TestingDuring testing, ensure that the measurement of the gate’s impact force has been performed in accordance with EN standards 12445 and 12453.• Check that the indications given in the SAFETY INSTRUCTIONS AND WARNINGS and INSTRUCTIONS AND INDICATIONS FOR INSTALLATION chapters have been carefully observed. • Ensure that the automation is correctly adjusted and that the protection and release systems are in good working order.• Using the key selector or the radio control perform gate opening and closure tests and ensure that each movement of the gate corresponds to the control unit settings. Perform as many checks as necessary to be certain of perfect operation.• Ensure the correct operation of the LEDs on the keyboard of the control unit (see specific manual).• In particular, for photocell checks, check that there is no interference with other devices. Pass a cylindrical tube with a diameter of 5cm and a length of approximately 30 cm through the optic axis that connects the two photocells. Perform this check firstly close to the transmitter and then close to the receiver and lastly halfway between the two.• In all three cases, the device must intervene by passing from the active state to the alarm state and vice versa, thus causing the action set on the control unit: for example, during a closure manoeuvre it must cause inversion of movement.• Perform the photocell operation test required in compliance with EN standard 12445 p. 4.1.1.6. The results must satisfy EN standard 12453 p. 5.1.1.6.

ATTENTION: once the automation has been tested, the parameters set must not be altered. If further adjustments (e.g. alterations to the voltage value) are made, all the checks required for testing and compliance with EN standard 12445 must be repeated.

8.2 First usageThe automation may only be used for the first time once all the checks described in the TESTING chapter have been performed successfully. The automation may not be used in precarious or temporary conditions.

a) Compile a technical file for the automation, which must include at least: • a general mechanical and electrical diagram, • risk analysis and solutions adopted for eliminating or reducing risks, • manuals of the individual components, • list of the components used, • instructions for use and warnings concerning use by the owner, • system maintenance record • declaration of the system’s CE conformity b) Fix a CE marking plate to the gate, bearing at least the following information: • Name and address of the party responsible for installation and testing; • Type of automation, • model, • registration number, • year of installation, • CE mark.c) Fill in the declaration of conformity and give it to the owner of the automation.d) Compile the guide with the instruction manual (EN 12635 p. 5.3 and 5.4) and give it to the owner of the automation.e) Compile the maintenance and improvement log (EN 12635 p. 5.3) and give it to the owner of the automation.f) Compile the guide containing the instructions for maintenance that provides instructions concerning the maintenance of all automation devices (EN 12635 p. 5.3 and 5.5) and give it to the owner of the automation.g) Before the first use of the automation, the owner must have been given adequate information concerning hazards and residual risks.

9 SAFETY INSTRUCTIONS AND WARNINGS

9.1 Instructions and warnings for use• It is the fitter’s duty to perform risk analysis and inform the user/owner of any existing residual risks. Any residual risk detected must be recorded in writing in the operator manual.• The following residual risks are usually present in moving gates: impact and crushing against the main closure surface (of the single leaf or between the two leaves); impact and crushing in the opening area; crushing between the mobile and fixed guide and support parts during movement; mechanical risks caused by movement.• The Manufacturer will not accept responsibility for damage or injury caused by the non-observance of the information on use contained in this manual, and the failure to observe the safety indications given below.• The Manufacturer declines responsibility for damage and malfunctions caused by non-compliance with the instructions for use.• Keep this manual in a safe and easily accessible place so that it can be consulted rapidly when necessary.• Before activating the gate ensure that all persons are at a safe distance.• Never touch the gate or moving parts when they are in motion.• Remain at a safe distance when the gate is in motion: only pass when the gate is completely open and immobile.• Do not allow children to play with gate controls; do not leave radio controls or other control devices within children’s reach.• Prevent children from playing or standing in the vicinity of the gate or the control organs (radio controls). The same precautions should be adopted for disabled persons and animals.• In the event of malfunctions (noisiness, jerky movements, etc.) suspend the use of the automation immediately:: failure to observe this rule may entail serious hazards, risks of accidents and/or serious damage to the gate and the automation. Contact a PROFESSIONAL FITTER and in the meantime use the gate manually by disconnecting the operator (see the OPERATOR/ACTUATOR RELEASE chapter) OPERATOR/ACTUATOR RELEASE chapter) of the operator manual.• In order to maintain the automation in efficient conditions, ensure that the operations indicated in the MAINTENANCE chapter are performed at the frequency indicated by a PROFESSIONAL FITTER.• Examine the installation frequently in order to check that there are no signs of mechanical unbalance, wear and damage to the wires and assembled parts: do not use the operator until the necessary repairs or adjustments have been made.• Should liquids penetrate inside the control unit, disconnect the electricity supply and contact the Manufacturer’s Assistance Service immediately; use of the control unit in such conditions may cause hazard situations. The automation may not be used in these conditions, even with buffer batteries (optional).• If a problem arises that cannot be resolved using the information contained in this manual, contact the Manufacturer’s assistance service.

Page 26: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

10 MAINTENANCE

10.1 Maintenance instructions and warnings• Once the automation has been tested, the parameters set must not be altered. If further adjustments (e.g. alterations to the voltage value) are made, ALL THE CHECKS REQUIRED FOR TESTING AND COMPLIANCE WITH STANDARDS MUST BE REPEATED.• The Manufacturer declines responsibility for damage or injury caused by non-compliance with the information provided in this manual and the safety instructions provided below. • The Manufacturer declines all responsibility for damage and malfunctions deriving from non-compliance with the maintenance instructions.• In order to keep the operator efficient and safe, follow the cleaning, checking and routine maintenance procedures as described in this manual. This is the owner’s duty.• Any checking, maintenance or repair work must be conducted by a PROFESSIONAL FITTER• Always switch off the electricity supply in the event of malfunctions, breakdowns and before any other operations in order to avoid the gate from being activated.• Always disconnect the operator’s power supply before performing any maintenance or cleaning operation.• The owner is NOT authorised to remove the control unit cover as it contains live parts.• If the power cable is damaged, it must be replaced by the Manufacturer or its technical Assistance service or in any case a person with a similar qualification in order to avoid risks.• If the power cable is damaged, it must be replaced by the Manufacturer or its technical Assistance service or in any case a person with a similar qualification in order to avoid risks.• Do not perform technical or programming modifications on the control unit. Operations of this type may cause malfunctions and/or risk of accidents. The manufacturer declines all responsibility for damage caused by products that have been modified.• In the event of intervention of automatic or fuse switches, before restoring function conditions identify and eliminate the fault. Request the intervention of a PROFESSIONAL FITTER.• The disconnection and replacement of the pair of buffer batteries (optional) may be performed by a PROFESSIONAL FITTER only.• If a fault that cannot be solved following the information contained in the present manual arises, contact the manufacturer’s assistance service.• All maintenance, repair or replacement of parts must be recorded in the maintenance log, which is SUPPLIED AND INITIALLY FILLED IN BY THE FITTER.

10.2 Routine maintenanceEvery 6 months a PROFESSIONAL FITTER should repeat the series of tests described for automation testing (see INSTALLATION MANUAL – TESTING AND TRIAL RUN Chap. ). – TESTING AND TRIAL RUN Chap.).

11 DEMOLITION AND DISPOSAL• The control unit is constructed using various materials, which implies the adoption of different disposal procedures. Refer to regulations in force in the country in which the automation is installed, especially with regard to the buffer batteries (if present).• If present the batteries must be removed from the control unit prior to disposal. Disconnect the control unit from the electricity supply before removing batteries.• Contact qualified firms for disposal.

ATTENTION: operator disconnection from the mains supply must be performed by a qualified electrician using suitable tools.

Page 27: ELECTROMECHANICAL OPERATOR FOR SLIDING GATES

3 A

Declaration of conformity

under Directive 98/37/EC, appendix II, part B (Manufacturer’s Declaration of CE Conformity)

LIFE Home IntegrationVia S.Pertini 3/5

31014 COLLE UMBERTO (TV)

declares that the following product:

RG1R DL control unit

satisfies the essential requisites established in the following directives:

• Low voltage directive 73/23/EEC and subsequent amendments,• Electromagnetic compatibility directive 89/336/EEC and subsequent amendments,• Radio and telecommunications equipment directive 1999/5/EC and subsequent amendments.

and satisfies the following standards:

• EN 12445:2000 Industrial, commercial and garage doors and gates – Safety in the usage of motorised doors – testing methods• EN 12453: Industrial, commercial and garage doors and gates – Safety in the usage of motorised doors – Requisites• EN 60204-1:1997 Machinery safety – Electric equipment of the machine – Part 1: general rules.• EN 60950 Information technology equipment - Safety - Part 1: General requisites• ETSI EN 301489-3:2001 Electromagnetic compatibility for radio equipment and appliances.• EN 300220-3:2000 Radio equipment and systems – short band devices – Technical characteristics and testing methods for radio apparatus with a frequency of 25 to 1000 MHz and powers of up to 500mW.

The Manufacturer also declares that it is not permitted for the abovementioned components to be used until such time as the system in which they are incorporated is declared conform to directive 98/37/EC.

COLLE UMBERTO ____________ Name of Signor: MICHELE RUI

Position: PRESIDENT

Signature: