electro hydrostatic actuators 2_mario valdo.pdf · + fail-safe options + easy redundancy (2+...

50
ELECTRO HYDROSTATIC ACTUATORS A NEW APROACH IN MOTION CONTROL 2nd Workshop on Innovative Engineering for Fluid Power Sep 2-3 2014

Upload: others

Post on 07-Aug-2020

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

ELECTRO HYDROSTATIC ACTUATORS

A NEW APROACH IN MOTION CONTROL

2nd Workshop on Innovative Engineering for Fluid PowerSep 2-3 2014

Page 2: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

2

Agenda

• Introduction - MOOG

• Actuation Technologies

• Electro Hydrostatic Actuators

• Applications

Page 3: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

3

Established in 1951, by Bill Moog

HIGH PERFORMANCE MOTION CONTROL SOLUTIONS FOR INDUSTRIAL, MILITARY AND AEROSPACE APPLICATIONS.

Sales (2013) = US$ 2,6 Billion

11.600 employees

FOCUS IN HIGH PERFORMANCE MOTION CONTROL

Page 4: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

4

EAST AURORA CAMPUS (BUFFALO-NY)

4

Space & Defense

Industrial

Aircraft

CorporateOffices

HR

Page 5: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

5

MOOG do Brasil Controles Ltda

Rua Prof Campos Oliveira, 338 Rua Agostinho Togneri, 457 Sto Amaro, São Paulo Phone (11) 3572-0400

Page 6: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

6

GROUPS

missiles and launchers trajectory control,

antenas and solar panels positioning, satelites

atitude control

Space and Defense Group

Slip rings, small motors, rotating joints, fiber optics

interfaces, air cooling solutions

Components Group

high performance motion control for industrial

applications, test (aerospace and

automotive), simulation

Industrial Group

primary and secondary flight control, engine

controls

Aircraft Group

Page 7: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

7

INDUSTRIAL GROUP - PRODUCTS

7

Servovalves

Page 8: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

8

INDUSTRIAL GROUP - MARKETS

8

TURBINES

Wind Gas, oil, hydro Automotive

SIMULATION TEST

Aerospace

Steel mills Presses RepairsOil & Gas

AFTERMARKETHEAVY INDUSTRY METAL FORMING

Formula 1

Page 9: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

9

Agenda

• Introduction - MOOGA

• Actuation Technologies

• Electro Hydrostatic Actuators

• Applications

9

Page 10: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

1010

SERVOCONTROL = closed loop motion controlLINEARposition

velocity

acceleration

force pressure

ROTARYangular position θ

velocity ω

acceleration α

torque T

Position Servocontrol

Kq1A

Positionset point

++ + --

-Ksa

KfD

istu

rban

ces

velocity position

Dis

turb

ance

s

flowTRANSDUCER

ERROR

mmvoltsFEEDBACK

+

-

Position

Q

P R

SERVOAMPLIFIER

Positionset point

Kq

Ksa

Kf

A

Page 11: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

11

ACTUATION TECHNOLOGIES

Electro-mechanical

Electro-hydraulic

Electro-hydrostatic

Page 12: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

12

ACTUATION TECHNOLOGIES

Conversão de Potencia Elétrica (V∙I) em Potencia Hidráulica (P∙Q)

ELECTRO-HYDRAULIC

V∙I p∙Q p∙Q F∙v

Elements: pump, servovalve, hydraulic cylinder. ·

Page 13: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

13

ACTUATION TECHNOLOGIESELECTRO-MECHANICAL

T∙ω F∙vV∙I T∙ω

Elements: servomotor, gearbox, ball/roller screw ·

Page 14: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

14

ACTUATION TECHNOLOGIESELECTRO-HIDROSTATIC

T∙ω p∙Q

p∙Q F∙vV∙I T∙ω

Elements: servomotor, pump, hydraulic cylinder. ·

·

+

Page 15: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

15

ACTUATION TECHNOLOGIESComparison

Electro-Hydraulic - EH Electro-Mechanical - EMA Electro-Hydrostatic - EHA

+ High robustness and reliability+ Ideal for high & static forces+ Fail-safe options + Easy redundancy (2+ actuators)+ No backlash+ Easy maintenance+ High frequency operation+ Compact size + Light weight

- Low energy efficiency- Requires HPU* & piping- Environment contamination

+ High energy efficiency+ Powered by wire (no HPU)+ Easy installation and

commissioning+ Environmental cleanliness + Well suited for rotary actuation+ High stiffness

- Heavy weight- No fail safe (gearbox can block)- No redundancy (single actuator)- High power consumption to holdstatic load

- Backlash- High maintenance effort ($)- Electrical noise

+ Good energy efficiency+ Powered by wire (no HPU)+ Easy installation and

commissioning+ High robustness and reliability+ Fail-safe options + Easy redundancy (2+ actuators)+ No backlash+ Good for high & static forces+ Unlimited hydraulic gearbox ratio

- Weight- Higher cost- Complexity - Electrical noise- Limited stiffness- Power consumption to holdstatic load

*HPU: hydraulic power unit = motor + pump + filtering + cooling

Page 16: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

16

Agenda

• Introduction - MOOG

• Actuation Technologies

• Electro Hydrostatic Actuators

• Applications

Page 17: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

17

EHA - AN OLD CONCEPT

Hydrostatic transmissions have been used in a wide range of mobile applications

Same principles can be applied to get a “Basic EHA”+ No need for a “separated” HPU+ Self contained hydraulic system- Low frequency response- Requires auxiliary devices (cooling, filtration, anti-cavitation)

Basic EHA

Hydrostatic Transmission

Variable pump

Hydraulic motor

Variable pump

longpiping

manifold

Hydraulic cylinder

Page 18: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

1818

EHA - DEVELOPMENTS

1) Replacing the variable pump by a fixed pump + servo motor• Gear Pump:lower cost, loss of

performance• Piston Pumps: higher cost, better

efficiency

2) Adding filtering, small accumulator(to keep system pressurized) and anti-cavitation check valves.

variable pump servomotor

fixed pump

filteranti-cavitationvalves

smallaccumulator

Page 19: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

19

EHA – OPERATION

vv

Balanced Cylinder

anti-cavitation valves

small accumulator

fixed pump

servomotor

Page 20: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

20

EHA – DEVELOPMENTS

pilot operatedanti-cavitation

check-valve

large accumulator

3) Dealing with unbalanced cylindersRequires:

• large accumulator : to hold the differential oil volume• pilot operated anti-cavitation check valves: to assure the pressurization of

the pump port to avoid cavitation

Page 21: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

21

v

EHA – OPERATION

v

v

Unbalanced Cylinder

v

v v

v

v

servomotor

fixed pump

large accumulator

anti-cavitation valves(one is pilot operated)

extend retract

Page 22: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

22

EHA – Dealing with unbalanced cylinders

• 3 ports pump, for unbalanced flow control

Page 23: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

23

EHA – CONTROL ARCHITETURE

M

TemposonicsTemposonics

Comando de Posição

Real

imen

taçã

o

Servomotor

Transdutor de Posição

Bomba Bidirecional

Position Transducer

Bidirectional pump

Servomotor

Position Command

Posi

tion

Feed

back

Hydraulic Cylinder

Page 24: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

24

EHA – CONTROL ARCHITETURE

Power Conversion : Electrical V∙I Mechanical T∙ω Hydraulic p∙Q Mechanical F∙ v

MACHINE EHA

Page 25: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

25

EHA – CONTROL ARCHITETURE

Electrical V∙I Mechanical T∙ω Hydraulic p∙Q Mechanical F∙v

DYNAMIC BEHAVIOR

ωT 1PositionServodrive

F

Large, low speed, high torque pump

Small, high speed, low torque pump

Page 26: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

EHA – SAFETY based on spring

Fail Safe MovimentNormal Operation

v

extend

extendretract

Page 27: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

27

v

EHA – SAFETY based on accumulator

Normal Operation -extend

v

Normal Operation - retract

Page 28: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

28

v

EHA – SAFETY based on accumulator

Fail Safe Moviment - extend

v

Accumulator Recharge

Page 29: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

29

Agenda

• Introduction - MOOG

• Actuation Technologies

• Electro Hydrostatic Actuators

• Applications

Page 30: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

30

APPLICATIONSEHA applications

• Injection molding machines

• Metal Forming & Presses

• Flight Control

• Wind turbines pitch control

Page 31: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

31

APPLICATION

M

A B

INJECTION MOLDING AND DIE CASTING MACHINES Clamp Unit & Ejector

CLAMP UNIT EJECTOR

Page 32: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

32

APPLICATION

EHA cushion control

METAL FORMING & PRESSES

CUSHION CONTROL - velocity and pressure control

M

M

3~

=

3~

= 3~

=

32

Page 33: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

33

APPLICATION

LOCKHEED MARTIN F-35 PRIMARY & SECONDARY

FLIGHT CONTROLS

Page 34: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

34

APPLICATION - FLIGH CONTROLFeatures• Manageable failure modes• Flexible packaging• Multiple electrical channels possible• High power consumption to hold load

• Overload relief• Multiple failure modes:

Normal servocontrolled operation Bypass (to allow other actuators to

operate control surface) Damped Blocked Damped - Blocked

Page 35: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

35

APPLICATION – FLIGHT CONTROL - REDUNDANCY

Active Bypass Blocked

v

v

Bypass Active Blocked

(or dampered)

v v v v

Page 36: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

36

vv

APPLICATION – FLIGHT CONTROL -REDUNDANCY

Active 1

vv

Active 2

Blocked

Blocked

(or dampered)

vv

Page 37: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

37

APLICATION - BLADE PITCH CONTROLWind TurbinePITCH CONTROL SYSTEM :adjusts the pitch turbine blade angle.

• 3 blades follows the same command (syncronized)• The turbine main controller sets blade pitch angle• The pitch control system is assembled inside the blades and rotates withthe turbine.

WIND

multiplyer

ELECTRICITY

blade

nacele

hub

torre

generator

Page 38: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

38

1. STOP the turbine in case of emergencies and failures2. MAXIMIZE energy conversion in a large wind speed range

Power ≈ pitch angle ∙ ( wind speed)3

38

APLICATION - BLADE PITCH CONTROLWind Turbine

Pow

er K

W

Wind speed[m/s]

Turbine with pitch control

Fixed pitch angle = 10º

Fixed pitch angle = 30º

power control range

CONFIABILITY is the main feature of a pitch control system

Page 39: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

39

APLICATION - BLADE PITCH CONTROLWind Turbine

39

BladePá

Hub

worker

Hub

workers

Blade

Hub

Wind farm

Blade

Page 40: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

40

APLICATION - BLADE PITCH CONTROLWind Turbine

EHA

Page 41: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

41

APLICATION - BLADE PITCH CONTROLWind Turbine

HU

B C

entra

l Con

trolB

ox

EHA 1

EHA 2

EHA 3

Page 42: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

42

APLICATION - BLADE PITCH CONTROLWind Turbine

Page 43: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

43

That’s all folks!

For additional info, please contact : Mario [email protected]: +55 (11) 3572-0404

MOOG do Brasil Controles LtdaRua Prof Campos de Oliveira, 33804675-100 São Paulo –SPPhone :+55 (11) [email protected]

43

Page 44: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

44

Motor

A B C D

HYDROSTATIC TRANSMISSIONSERVOPUMP

Swasplate positionmechanical feedback

Control Valve

Page 45: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

45

EHA – SAFETY BALANCED CYLINDERNormal Operation

Page 46: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

46

EHA – SAFETY BALANCED CYLINDERFail-Safe Movement

Page 47: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

47

EHA – SAFETY BALANCED CYLINDER

Actuator Locked

Accumulator Recharge

Page 48: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

4848

M

M

M

Page 49: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

49

Electro-Hydrostatic Actuation

• Power on demand, Energy efficient,Energy recovery

• Powered by wire Self-containedNo hydraulic piping

• Additional featurese.g. fail safe

• Low noise

• High force capability

EHA characteristics

49

Page 50: ELECTRO HYDROSTATIC ACTUATORS 2_Mario Valdo.pdf · + Fail-safe options + Easy redundancy (2+ actuators) + No backlash + Good forhigh & static forces + Unlimited hydraulic gearbox

50

Balanced EHA Unbalanced EHA

50

Electro-Hydrostatic Actuation