MECHANICAL & ELECTRICAL WORKS
MEASUREMENT (SBEQ3213)Week 9 : Electrical Installations Three Phase
Sr. Dr. Sarajul Fikri Mohamed
Faculty of Built Environment
-
7/23/2019 Elect Inst Three Phase
2/40
Cold Water InstallationsPLUMBING WORKS
Electrical Installations
Fire Fighting System
MAIN COURSE COMPONENTS
Air Conditioning Installations
Unit/Split Package/Central
Single Phase Three Phase
ELECTRICAL WORKS
MECHANICAL WORKS
Soil & Waste Pipes/Sanitary Fittings
Underground Drainage
-
7/23/2019 Elect Inst Three Phase
3/40
1. Electrical installations: main components
2. SMM2 measurement rules for electrical installations
3. Taking off list for electrical installations
4. Heading and description.
5. Case study: CADANGAN MEMBINA DEWAN SERBAGUNA
TAMAN KOTA JAYA, KOTA TINGGI, JOHOR
TABLE OF CONTENT
-
7/23/2019 Elect Inst Three Phase
4/40
2009 Sarajul Fikri Mohamed
ELECTRICAL INSTALLATIONS
AND MAIN COMPONENTS
-
7/23/2019 Elect Inst Three Phase
5/40
INCOMING SERVICES
MAIN INSTALLATION
POWER INSTALLATION
LIGHTING INSTALLATION
CABLES
ELECTRICAL APPLIANCES
CONDUIT AND FITTING
LIGHTNING PROTECTION SYSTEM
TESTING
ELECTRICAL INSTALLATIONSTHREE
PHASE
-
7/23/2019 Elect Inst Three Phase
6/40
INCOMING SERVICES
MAIN INSTALLATION
POWER INSTALLATION
LIGHTING INSTALLATION
ELECTRICAL APPLIANCES
FINAL SUB-
CIRCUIT
CABLE
CONDUIT
LIGHTNING
PROTECTION
TESTING
ELECTRICAL DISTRIBUTION IN BUILDING
-
7/23/2019 Elect Inst Three Phase
7/40 2009 Sarajul Fikri Mohamed
SMM2 MEASUREMENT
RULES
-
7/23/2019 Elect Inst Three Phase
8/40
MEASUREMENT RULES
ELECTRICAL INSTALLATION
-
7/23/2019 Elect Inst Three Phase
9/4029
Clause Description
R4-R5 Equipments and Control Gear
R6-R8 Fittings and Accessories
R9-R13 Conduits, trunking and cable trayR14-R17 Cabling
R18 Final Sub-circuits
R19 Earthing
R20-R21 Ancillaries
R22 Sundries
R23-R24 Builders Work
RELATED SMM2 CLAUSES
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
10/40
MEASUREMENT RULES
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
11/40
EQUIPMENT AND CONTROL GEAR (NO)
R4Equipment (generator, motors)
Control gear (isolator, switch fuses)
Packaged item described with a manufacturers detail.
Limiting dimension on size shall be given.
Connecting cable ends or cable tails shall be deemed to be
included with the item.
Platework and supporting steelworkSection P.
MEASUREMENT RULES
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
12/40
HEADING AND DESCRIPTION
MAIN INSTALLATIONS1. EQUIPMENT AND CONTROL GEARItem Description Unit Qty Note
A
B
Equipment and Control Gear
415 volt metal clade main switch board, 3 phase of wall
mounted floor standing type and including fuse swithches,
RCCVs, copper busbar, voltmeter, ammeter, current
transformer, light indicator, cable box and all associated
accessories.
TNB metre board control gear complete with cut out fuse
holder and neutral link with facilities for termination of
incoming supply cable for wiring connection main switch
distribution board and fuses 60A current operated ELCB
complete with earthing elctrode.
No
No
2
1
-
7/23/2019 Elect Inst Three Phase
13/40
EQUIPMENT SUPPORTS : R5
Equipment supports enumeratedand described (NO)
Method of fixing given in the description with clauses R.1.5-6.
MEASUREMENT RULES
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
14/40
MEASUREMENT RULESELECTRICAL INSTALLATION
-
7/23/2019 Elect Inst Three Phase
15/40
2. Power Installation- fitting & accessories
= socket no
- cables m
- conduits m
- final sub-circuit no
- sundries= mark holes item
= general bonding item
= testing item
TAKING OFF LISTS
DOMESTICHOUSING SINGLEPHASE
-
7/23/2019 Elect Inst Three Phase
16/40
SOCKET
POWER INSTALLATION
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
17/40
MEASUREMENT RULESELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
18/40
A rectangular metal made
system that either horizontally
or vertically fixed to wall.
A good mechanical protection.
Made from 18 gauge steel sheet.
Available size:
50mm x 50mm
70mm x 100mm
150mm x 75mm
150mm x 150mm
Equipped with bend, tee, and
junction.
TRUNKING
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
19/40
Cable and trunking use for connection from main to distribution board or
distribution board to socket.
Size and Material.
SMM2 Refer to clause R.15, R.9 (M)
TRUNKING
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
20/40
CONDUIT, TRUNKING AND CABLE TRAYS
R12.1 Trays (m)i) type; ii) width; and iii) method of jointing
R12.2 Stools (NO)
i) type; and ii) size
R12.3 Fitting (NO and EXTRA OVER )
MEASUREMENT RULES
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
21/40
CABLE TRAY
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
22/40
MEASUREMENT RULES
ELECTRICAL INSTALLATION
-
7/23/2019 Elect Inst Three Phase
23/40
CABLES
R15.1Cables (m)
measured as the net length of the conduit, trunking or tray.
other cable measured as fix (without any allowance for sag)
between boxes, equipment control gear, fittings, accessories etc.
except for final sub-circuits.
MEASUREMENT RULES
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
24/40
CABLE
R17 Connections to public mains, making good public highway and
other work which may only carried out by Public Undertaking
or Local AuthorityPROVISIONAL SUM
MEASUREMENT RULES
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
25/40
MEASUREMENT RULESELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
26/40
3. Lighting Installation- fittings & accessories
= switch no
- cables m
- conduits m
- final sub circuit no
- sundries= mark holes item
= general bonding item
= testing item
TAKING OFF LISTS
DOMESTICHOUSING SINGLE PHASE
-
7/23/2019 Elect Inst Three Phase
27/40
MEASUREMENT RULESELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
28/40
4. Electrical Appliances- fitting & accessories
= Exhaust fan no
- cables m- conduits m
- final sub circuit no
- sundries
= mark holes item
= general bonding item= testing item
TAKING OFF LISTS
DOMESTICHOUSING SINGLE PHASE
-
7/23/2019 Elect Inst Three Phase
29/40
HEADING AND DESCRIPTION
POWER INSTALLATIONS4. ELECTRICAL APPLIANCES (Internally)
Item Description Unit Qty Note
A
B
C
D
E
Cables
2 x 8mm2 PVC cable in concealed galvanised iron conduit come with 1 x 8mm2 PVC
CPC
Conduit
25mm diameter PVC galvanised iron conduit concealed to brickwall for exhaust fan
Fitting and Accessories
150mm x150mm metal exhaust fan install at high level complete with support brackets,
flexible connectors and vibration.
1 gang 15 Amp switch outlet for exhaust fan with PVC plate box and fixed to brick wall
Final Sub-Circuit
Final sub-circuit fir 15A socket point for metal exhaust fan of concealed conduit cable
installation consisting od 2 x 8mm2 single core cable drawn into galvanised iron conduit.
m
m
No
No
No
15
35
5
5
5
-
7/23/2019 Elect Inst Three Phase
30/40
MEASUREMENT RULESELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
31/40
EARTHING
R19.1 Tapes for earthing(m)
i) size;ii) type; andiii) type & spacing of saddles, cleats, clip holdfasts & the like
R19.2 Conductor connections & junctions (NO)
i) type; and ii) sizeR19.4 Test clamps (NO)
i) type ii) size; and iii) method of connecting
MEASUREMENT RULESELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
32/40
Air Terminal
Cooper Tape
LIGHTING PROTECTION SYSTEMELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
33/40
ELEMENT: ELECTRICAL SERVICES ubb/N/04
BIL UNIT KUANTITI
NO 16
NO 16
H
M 29.00
Brass test c lamp complete wi th screws. NO 2
NO 2
NO 2
To Collection
HARGA
(RM)
JUMLAH
(RM)
25mm x 3mm copper tape at roof including propose
made copper or brass c lips at 1000mm internals and
connecting to roof tapes.
500mm High Solid Copper air termination with
formed thread complete with bronze nut and
appropriate thickness copper air terminal base.
Cadangan Membina Dan Menyiapkan Sebuah Makmal Komputer Di Sekolah Kebangsaan Sri
Selangor, Petaling Jaya, Selangor.
KETERANGAN
Lighting Installation-Internally (All Provisional)
(Cont'd)
3 x 36W recessed mounted fluorescent light fitting
with low loss ballast C/W acrylic diffuser 2 x
1.5mm/1C PVC in concealed UPVC conduits with
5A switch.
300mm x 300mm x 300mm deep concrete Earth
Electrode Chamber complete with concrete cover
from ground level, lightweight screed to prevent
ingres of water, 16mm solid drawn copper Earth
Electrode, copper tape and 50mm UPVC pipe.
3 x 36W recessed surface fluorescent light fitting
with low loss ballast C/W acrylic diffuser 2 x
1.5mm/1C PVC in concealed UPVC conduits with
5A switch.
Lightning Protection-Externally (All Provisional)
COOPER TAPE
ELECTRODE CHAMBER
-
7/23/2019 Elect Inst Three Phase
34/40
Typical earth-electrode pit
Earthing using cooper strip
Earthing & Bonding
requirement
EARTHING INSTALLATIONELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
35/40
-
7/23/2019 Elect Inst Three Phase
36/40
-
7/23/2019 Elect Inst Three Phase
37/40
Air Termination (NO.)
Copper Tape Roof Conductor. (M)
SMM2 Refer to clause R.19.6, R.22.2, R.19.
LIGHTNING PROTECTION INSTALLATION
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
38/40
ANCILLARIES
R20 Loose keys, tools, spares and the like (NOseparately)
i) type; and ii) quantity
Rack for holding tools (NO)
MEASUREMENT RULES
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
39/40
SUNDRIES
R22.1 Marking the position of holes, mortice, chases & the like
(ITEM)
R22.2 General earth bonding & earthing (ITEM)
R22.3 Disconnecting, setting aside & refixing equipment (ITEM)
R22.4 Temporary operating each installation (ITEM)
R22.5 Testing each installation (ITEM)
R22.6 Preparing plans or diagrams of the installations (ITEM)
MEASUREMENT RULES
ELECTRICAL INSTALLATIONS
-
7/23/2019 Elect Inst Three Phase
40/40