egi - secura primma brochure (english) - 004806

13
primma medium basic plus  www.egiaudio.com  Assistance communication in hospitals and residential homes for the elderly The greatest offer in assistance communication in hospitals and residential homes for the elderly

Upload: alhassny

Post on 09-Apr-2018

249 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: EGi - Secura Primma Brochure (English) - 004806

8/8/2019 EGi - Secura Primma Brochure (English) - 004806

http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 1/12

primma

medium

basic

plus

 www.egiaudio.com

 Assistancecommunication in

hospitals andresidential homes

for the elderly 

The greatest offer in assistance communicationin hospitals and residential homes for the elderly

Page 2: EGi - Secura Primma Brochure (English) - 004806

8/8/2019 EGi - Secura Primma Brochure (English) - 004806

http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 2/12

Page 3: EGi - Secura Primma Brochure (English) - 004806

8/8/2019 EGi - Secura Primma Brochure (English) - 004806

http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 3/12

   3

EGi Secura "primma" is an alarm and intercommunication system to be used in public

installations and specially in hospitals and residential homes for the elderly.

As it is easy to operate and to install, Secura Primma is the most competitive and suitable

solution for hospitals and residential homes for the elderly which have up to 1020 rooms.

These rooms can be controlled from one or more places which, in turn, can be re-addressed

to a different control point (e.g. to the night duty post).

Assistance communication

in hospitals and residential

homes for the elderly

Page 4: EGi - Secura Primma Brochure (English) - 004806

8/8/2019 EGi - Secura Primma Brochure (English) - 004806

http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 4/12

 4

EGi Secura "primma" is an alarm and intercommunication

system wich allows:

 Assistance communication

in hospitals and residences

 for the elderly,up to 1020 rooms.

 Alarm management either manual or 

automatically generated from rooms (bedrooms) or other places.

Call identification (room origin,

 type of alarm, ...) and

assistance information.

In-the-room lighting signal indicating

alarm activation and its type:presence, normal, urgency or emergency.

Bi-directional communicationbetween resident and control point.

Computer connection for querying,

on screen or printed report,of historical alarm events ordered by type,

date or resident.

Easy bus type installation.

Page 5: EGi - Secura Primma Brochure (English) - 004806

8/8/2019 EGi - Secura Primma Brochure (English) - 004806

http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 5/12

   5

 Assistance communication

in hospitals and residentialhomes for the elderly 

Medical and health centres

Hospitals

Emergency centres

Specialized clinics

Spa

Residential homes for the elderly

Residences

Apartments

Day care centres

Page 6: EGi - Secura Primma Brochure (English) - 004806

8/8/2019 EGi - Secura Primma Brochure (English) - 004806

http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 6/12

 6

5503 

125

110

70mm5503

Under order

Remote room terminal 

Placed in the floor bus, this device connects 2 single rooms or a double room

(with 2 beds) to its nurse calling station. It is connected to the system by a 6-wire bus cable (power, data and audio)

EGi ref. 5504.

To be fastened to DIN rail (7u. width) and placed in a surface mounting box

or flush mounting box.

It is equiped with plug-in connectors to make the installation easier.

It must be placed as close as possible to the room(s) to be controlled. It can

be concealed in a false ceiling as long as a solid structure it is used (never

loose-fitting or leant on the false ceiling).

Available per room:

Digital inputs: assistant care presence, normal call and urgency call

(through normally closed push-button activation).

Digital outputs: presence and call signals.

  Configurable auxiliary port.

Preamplified microphone and loudspeaker to allow bidirectionalconversation with the floor control unit.

Up to 510 remote room terminals can be installed (which means up to 1020

single rooms).

The terminal can be configurable as:

MODE 1: installation for 2 single rooms with individual recognition of the

patient generating the call; auxiliary port available to be used as input/output,

or installation in a double room without individual recognition of the patient

generating the call; auxiliary port not available as it is being used by the

second bed of each room.

MODE 2: installation in a double room, with individual recognition of the

patient generating the call; auxiliary port available to be used as input/output.

Configurable auxiliary port can be set as input/output (the configuration for

both rooms is shared). When set as input, it could be used to generate either

normal or urgency calls as soon as the room will be provided with additional

warning elements (presence sensor, window opening sensor,...). When set as

output, it can be used to activate any device through a free-voltage contact.

Equipped with fast connectors to make the installation easier 

Page 7: EGi - Secura Primma Brochure (English) - 004806

8/8/2019 EGi - Secura Primma Brochure (English) - 004806

http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 7/12

   7

5303 

5803 

71

71

49mm

248

200

180mm

5803

5303

Under order

Floor interface 

Floor interface is the device that links the floor bus into the inter-floor bus. In

the same way, it links a group of remote room terminals into its corresponding

nurse calling station. Even more, any call from a room can be diverted to the

main nurse calling station whenever its nurse calling station is out of order.

The following connections are allowed:

to the nurse calling station through a flexible cable (included) with RJ12

connectors at both ends

to floor bus and inter-floor bus through terminal blocks connections (*),

to the computer through the interface 5805 with a flexible cable with RJ12

connectors at both ends.

VERY IMPORTANT: connection between the floor interface and the inter-floor

bus will always be made through the bus signal generator 5804 (a 100x100

mm junction box is recommended). DO NOT CONNECT THE FLOOR

INTERFACE DIRECTLY TO THE INTER-FLOOR BUS

Nurse calling station 

It allows to receive calls from the assigned rooms as well as establish an audio

communication with them.

It has been thought as an independent unit for each floor of a building so that

it can answer the calls received from that floor.

All the calls from any floor can be diverted from its assigned calling station

to the designated main nurse calling station, so that any call from any room

can be answered in only one place. IT IS RECOMMENDED to have a place

where a main nurse calling station can supervise the good working order of

the system.

The main nurse calling station displays all the events permanently but it will

not take part on a room alarm unless the calls from that floor are diverted.

Any nurse calling station can be configurated as main, but there can only be

one.

The nurse calling station consists of 2 devices:

a customized telephone terminal

a console with display screen, desk microphone and loudspeaker.

Apart from answering the calls from the residents, it can establish a conversation

with the rooms by simply dialing the room number on the telephone keyboard.

There are two ways of answering a call:

by using the console microphone and loudspeaker (halfduplex conversation

mode), by pressing and releasing the speaking push-button

by picking-up the handset once the call is selected on the console (private

and full-duplex conversation mode).

The unit has 2 connectors:

RJ12 to be connected to the floor interface

RJ45 to connect the customized telephone terminal (included).

There are 2 potentiometers available to adjust the loudspeaker volume level

and the micro-loudspeaker volume level of the handset.

Maximum 32 nurse calling stations per installation.

A nurse calling station contains: A customized telephone

terminal. A nurse console with

display, gooseneckmicrophone andloudspeaker.

Page 8: EGi - Secura Primma Brochure (English) - 004806

8/8/2019 EGi - Secura Primma Brochure (English) - 004806

http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 8/12

Page 9: EGi - Secura Primma Brochure (English) - 004806

8/8/2019 EGi - Secura Primma Brochure (English) - 004806

http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 9/12

   9

5201

5201

5701

5103

5202

5204

5104

G26U/16

5701

5103 

5202 

5104 

G26U/16 

5204 

520607.12LED corridor lights 

Allow the visual information about the type of call generated in one room.

Can be installed in standard 60 mm flush-mount box.

LED technology to reduce consumption and maintenance costs.

Green and red colour.

White coloured when in "off" mode and red or green coloured when activated.

This makes it easy to distinguish when the system is activated, while allowing

easy integration into the hospital decor.

Bathroom pull-cord wall unit 

To be installed in a 60 mm standard box, it can combine with other series of

electrical switchgear.

It works together with the bathroom pull-cord EGi 5701.

Bathroom pull-cord 

Ergonomic design.

It incorporates a 2m cord with anti-strangling system.

Fluorescent ring to facilitate visibility in the dark.

To connect to EGi 5201.

Acoustic alarm when pulling the cord.

Bedside push-button wall unit 

To be installed in a 60 mm standard box, it can combine with other series ofelectrical switchgear.

It works together with the bedside push-button EGi 5202.

Jack connector reduces accidental pull-off. In this case, an alarm is generated.

Bedside push-button 

Ergonomic design.

Fluorescent ring to facilitate visibility in the dark.

To connect to EGi 5103.

Acoustic alarm when pushing the button.

It incorporates anti-strangling system.

Nurse presence push-button 

To be installed in a 60 mm standard box, it can combine with other series of

electrical switchgear.

When pushed, it allows to notify nurse presence in the patients room.

Microphone + preamplifier 

To be installed in a 60 mm standard box, it can combine with other series of

electrical switchgear.

It works together with the loudspeakerG26U/16 or other EGi 16 loudspeakers.

It allows hands-free conversation between the user and care assistants.

Under order

Loudspeaker 2 W 16 W

2" wall loudspeaker for 60 mm mounting box. Wide band. 16 impedance.

5211

Page 10: EGi - Secura Primma Brochure (English) - 004806

8/8/2019 EGi - Secura Primma Brochure (English) - 004806

http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 10/12

 1 0

The installation is based on the use of a field bus of 6-wire cable (powersupply, digital data and audio).

Bus topology is described on the image below. Two bus levels are

considered: floor bus and inter-floor bus. Floor bus gathers remote roomterminals of this floor and its nurse calling station; inter-floor bus gathers

System architecture

floor buses through bus signal generators. One or more 15 Vdc powersupply are needed depending on the number of connected devices.

Each remote room terminal can control two single rooms or a double

room. It incorporates input and output ports for controlling alarm activation.

1st Floor

Hall/Reception

2nd Floor

"N" Floor

Page 11: EGi - Secura Primma Brochure (English) - 004806

8/8/2019 EGi - Secura Primma Brochure (English) - 004806

http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 11/12

Page 12: EGi - Secura Primma Brochure (English) - 004806

8/8/2019 EGi - Secura Primma Brochure (English) - 004806

http://slidepdf.com/reader/full/egi-secura-primma-brochure-english-004806 12/12

D I S T R I B U T O R

Avenida Almozara, 7950003 ZARAGOZASPAIN

Tel. +34 976 40 53 56Fax +34 976 40 53 54

e-mail: [email protected]

   D   E

   S   I   N   G    A

   N   D    P

   R   E  -   P   R   I   N   T   I   N   G  :

  +   3   4   9   7   6   5   9   0   7   4   9

   C   ó   d .   0   0   4   8   0   6

   D .   L .  :   Z  -   0   0   0   0  -   0   0