Superior Quality of Results
• Multi-AngleFlowCytometricDigitalMorphology technologyandadvancedalgorithmsensure exceptional quality of results
• 29measurementspercellulareventtoaccurately characterizeWBCdifferentialsamples,ensuring first-pass accuracy and efficiency
• 2D-dataplots,surfaceplotsand3D-cubeformats allowforenhanced visual cellular investigation
Extended Testing Capabilities
• Multi-AngleFlowCytometricDigitalMorphology technologydeliversAutomatic NRBC enumeration,withouttheneedforadditional reagentsorexpensivestains.
• Automatic ReticulocyteandBody Fluid Analysis capabilities
Improved Efficiency
• ExtendedDecisionRulescapability andAuto-Rerun and Reflex testing reduceTATandtheneedformanual operatorintervention
• Runstandardandmicro-volume WholeBloodSampleTubesin Automatic Cassette Mode
• Single Aspiration Pathway, simplifiescalibrationandquality controlprocesses,whileeliminatingmode-to-mode procedures
• Intelligent Workload Tracking, softwareallowsforworkload trackingbyday,hourandtest
Standardization of Process
• SametechnologyandUser InterfaceastheUniCel DxH800allowfortrue standardization of process and resultsacrosstheDxH seriesandreduces laboratory personnel training needs
• Sharedconsumableswiththe DxH800allowfor simplified inventory management
BeckmanCoulterisonceagainleadingthewayinleanlaboratorypracticesandefficiencywiththeintroductionoftheUniCelDxH600CoulterCellularAnalysisSystem.
Deliveringexceptionalqualityofresults,first-passaccuracyandefficiencythroughcutting-edgetechnologytheUniCelDxH600CoulterCellularAnalysisSystemdeliversunparalleledvalueforyourmid-to-largevolumelaboratory—allwithasmallfootprint.
Flow Cytometric Digital Morphology optimizes system performance
Data Plots and Surface Plots for NRBCs and Reticulocytes
BD Microtainer MAP Microtubes* utilized in DxH Cassette
Easy-to-Use User Interface Reduces Training
Blood Banking
Centrifugation
Chemistry
Flow Cytometry
Hematology
Immunoassay
Information Systems
Lab Automation
Molecular Diagnostics
Rapid Diagnostics
DS-17805A NotfordistributioninU.S.markets.
Designedforefficiencyinyourlab.
UniCelDxH600CoulterCellularAnalysisSystem
UniCelDxH600CoulterCellularAnalysisSystemSpecifications
Available Test MenuCBC WBC,UWBC,RBC,HGB,HCT,MCV,MCH,MCHC,RDW,RDW-SD,PLT,MPVDifferential NE,LY,MO,EO,BA,NRBC,NE#,LY#,MO#,EO#,BA#,NRBC#Retic RET,RET#,MRV,IRFBodyFluids(Spinal,SerousandSynovial) TNC,RBC
ThroughputUpto100samples/hr
Aspiration VolumesOpen/ClosedVial165μL
Power90–264VACand48–62HZDxH600SystemwithSystemManagerandprinterdraws1,185wattsDxH600SystemwithSystemManager,PrinterandUPSdraws2,390watts
Weight and Dimensions Depth Width Height WeightSpecimenProcessingModule 78.7cm 76.2cm 96.5cm ~117.5kg (31.0in) (30.0in) (38.0in) (260lb)PneumaticSupply 51.0cm 21.6cm 36.8cm ~18.4kg (20.0in) (8.5in) (14.5in) (40.5lb)
Whole Blood Performance — Measuring RangeWBC 0.050–400.000X103μLRBC 0.005–8.500X106μLHGB 0.10–25.50g/dLMCV 50.00–150.00fLPLT 3.0–3,000.0X103μLNRBC 0.00–600.00/100WBCRetic 0.000–30.000%
Data ManagementComputer MicrosoftWindows**XPDatabase 40,000PatientresultswithGraphicsQualityAssurance QCwithLevy-JenningsGraph,XB/XMforMoving Averages,DailyCheck,IntelligentQualityMonitoring
Sample Transport CapabilitiesCapacity20five-tubecassettesBarCodesDigitalBarCodewith2DBarCodecapabilitySampleIDUpto22characters
www.beckmancoulter.com/DxH
ForBeckmanCoulter’sworldwideofficelocationsandphonenumbers,pleasevisitwww.beckmancoulter.com/contactDS-17805A B2012-13934 www.beckmancoulter.com © 2012 Beckman Coulter, Inc. PRINTED IN U.S.A.
*BDandMicrotainerMAPMicrotubesaretrademarksofBecton,Dickenson andCompany **MicrosoftandWindowsaretrademarksofMicrosoftCorporation
BeckmanCoulter,thestylizedlogo,CoulterandUniCelaretrademarksof BeckmanCoulter,Inc.andareregisteredwiththeUSPTO.DxHisatrademark ofBeckmanCoulter,Inc.
Intelligent Workload Tracking Software allows for workload tracking per day, hour and even test