effective date: 04/01/2013
DESCRIPTION
KENTUCKY WATERSHED WATCH RECERTIFICATION – PHASE 1. Effective Date: 04/01/2013. Training and Certification Workshops. Phase 1 Field Chemistry Assessment Grab Sample Collection. Phase 2 Biological Assessment Habitat Assessment. Phase 1 Watershed Watch Recertification. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/1.jpg)
Effective Date: 11/1/2015
KENTUCKY WATERSHED WATCH RECERTIFICATION – PHASE 1
![Page 2: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/2.jpg)
P h a s e 1• Field Chemistry Assessment• Grab Sample Collection
Training and Certification Workshops
Phase 2• Biological Assessment• Habitat Assessment
![Page 3: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/3.jpg)
Phase 1Watershed Watch
RecertificationGoals for this module• Refresh your skills• Highlight changes to sampling procedures• Distribute NEW flip books• Check out any replacement equipment you need• Complete essential recertification paperwork
![Page 4: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/4.jpg)
How we’re set up:
Basin Steering Committee or Board of Directors
Watershed Watch In KentuckyBoard of Directors
Sampling Event CoordinatorLab Manager Science Advisor(s)
Area coordinator
Area coordinator
Area coordinator
Watershed Watch Trained
Sampler
Watershed Watch Trained
Sampler
Watershed Watch Trained
Sampler
Watershed Watch Trained
Sampler
![Page 5: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/5.jpg)
Goal: Get people into the real world to see first hand the condition of their streams.
![Page 6: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/6.jpg)
Watershed Watch provides you the tools and information you need to
educate and inform
YouFamily Friends
NeighborsCommunity
Local LeadersResource Management Agencies
![Page 7: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/7.jpg)
How you can use your information
• Personal decision making• Local action• Grant applications• Watershed planning• Assessment screening• Enforcement efforts• Scientific research
Data usage depends on the quality control applied…
![Page 8: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/8.jpg)
Standard OperatingProcedures (SOP)
• Training workshops for certification• Standard methods of collection• Standard methods of analysis• Full chain of custody and/or forms• Careful recordkeeping!
For good Quality Assurance of results, we require:
![Page 9: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/9.jpg)
Standard Operating Procedures (SOP)
To ensure standard
methods of collection, always useflip cards
when sampling:
![Page 10: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/10.jpg)
This presentation is based on the “Kentucky Watershed Watch Field Chemistry Sample Collection Standard Operating Procedure WWSOP01000” and is available fromwww.kywater.org
SOP Statement
![Page 11: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/11.jpg)
Standard OperatingProcedures (SOP)NEW Flip Book
Field Chemistry
![Page 12: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/12.jpg)
• You will receive materials from program coordinators or by mail
• Read instructions upon receipt! (Critical info on sample times and delivery included)
• Inspect all sample and preservative containers upon receipt for damage or breakage
You will receive for sampling:• Instructions• Transport information• Chain of Custody Records• Gloves (disposable)• Sample containers• Preservative (if required)
Pre-sampling Information
![Page 13: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/13.jpg)
•During high flow, sampling should be postponed until baseline conditions exist – do not sample in any unsafe conditions•Waders and specialized wading boots can be utilized•Use extreme caution when wading in streams above the knee•Samplers should exhibit caution in and around streams to reduce the threat of a falling injury •Secure permission from landowner •Be aware of increased risk for frostbite or hypothermia in cold temperatures•Do not stick hands or feet under large objects. Exercise caution when handling aquatic life. Some organisms pinch, bite, etc.• All water bodies have the potential to be contaminated • Notify others of your whereabouts and carry a cell phone• Use caution and be aware of your surroundings and location
Be Safe!
![Page 14: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/14.jpg)
Equipment• You will need to purchase a gallon of distilled water for use during sampling events
• All field chemistry sample containers must be rinsed with distilled water after each test
![Page 15: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/15.jpg)
Equipment
• Use your Waste Container to dispose of all used chemicals
• After rinsing field chemistry sample containers, dispose of rinse water in Waste Container
• After sampling event, flush contents of Waste Container into a system that goes to a wastewater treatment plant
![Page 16: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/16.jpg)
• Store in a cool, dry place (climate controlled) NOT a hot car or freezing garage!• Store out of reach of children and pets
In addition:• Chemicals should be replaced every three years at your recertification training• Kits have enough chemical for 50 tests! (use them all you want!)• Should you need replacement chemicals or glassware before then, let us know
Equipment
![Page 17: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/17.jpg)
• There are hazardous chemicals in these kits!• Dissolved Oxygen (DO) test uses a strong acid and alkali (like bleach)
• pH Test chemical is flammable• Read Material Safety Data Sheets (MSDS) for further information on chemical safety• Dispose of used chemicals in plastic waste container at stream and then flush into municipal wastewater treatment system (no septic systems)• Trade in old chemicals for proper disposal when you receive replacement chemicals
EquipmentChemical Safety
![Page 18: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/18.jpg)
Proper attire for performing tests• Gloves (disposable)
• Eye protection
EquipmentChemical Safety
![Page 19: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/19.jpg)
What to do if you get a chemical on you
•For emergency first aid in the field, flush affected area with large amounts of water and seek medical attention if necessary
•Follow the first aid procedures found on the Material Safety Data Sheets (MSDS)
EquipmentChemical Safety
![Page 20: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/20.jpg)
Field Observations and
Water Chemistry Assessment
• Enter stream at a downstream location • Walk upstream to avoid disturbing bottom • Perform your observations and tests just below your grab sample location
Sampling Procedure
![Page 21: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/21.jpg)
0 = Dry1 = Ponded2 = Low3 = Normal4 = Bank Full5 = FLOOD!
Field ObservationsFlow Rate
0-5 Point Scale
Do not sampleduring these flow conditions
![Page 22: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/22.jpg)
48 Hour RainfallUse Weather Channel,
local paper or rain gauge
OR Use any of these
websites
www.cocorahs.org/state.aspx?state=kywwwagwx.ca.uky.edu/cgi-bin/ky_clim_data_www.pl
water.weather.gov/
www.kymesonet.org/
Field Observations
To determine 48 hour rainfall in inches
![Page 23: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/23.jpg)
Site coordinates and Photos• GPS (decimal degrees – 5 decimal places)
OR Digital map (KGS WW Site - http://kgs.uky.edu/wwky/main.htm or Google Earth)
• Take photos upstream and downstream of sampling point – with recognizable landmarks; should be taken annually during Summer sampling event
• Label photos: “Site#upstream” and “Site#downstream”
• Submit information to Water Watch office Email: [email protected]
Phone: 502-782-7032
Additional Field Observations
![Page 24: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/24.jpg)
• Put on gloves• Collect water just below your grab sample location• Rinse bottle, tube or cup and any associated caps or lids with stream water three times (fill container ¼ full of stream water, cap, shake, and discard downstream)• Point mouth of bottle, tube or cup directly at the surface of the water, submerge entire container to mid-depth of stream, scoop upstream and fill to appropriate level
For Field Chemistry tests:• pH• Dissolved Oxygen• Conductivity(does not include Temperature)
Field Measurements
![Page 25: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/25.jpg)
Conductivity EquipmentField Measurements
Meter Calibration
• Must be calibrated for each sampling event• Calibrate to 720 µS (standard solution is 718 µS)
New MeterOld Meter
![Page 26: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/26.jpg)
Watershed Watch Chain of Custody Record
Conductivity EquipmentField Measurements
Meter Calibration
• Record meter calibration date on COC
• Must be calibrated within 24 hours prior to sampling event
![Page 27: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/27.jpg)
Conductivity Equipment – New MeterField Measurements
New Meter Calibration• Display• Hold/enter• Calibrate• Power• Calibration Standard
![Page 28: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/28.jpg)
Conductivity EquipmentField Measurements
![Page 29: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/29.jpg)
Video on how to calibrate your conductivity meter
• I f you go to www.kywater.org and scroll down to Volunteer Resources you will see a YouTube video on how to calibrate your conductivity meter.
![Page 30: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/30.jpg)
Conductivity Equipment – Old MeterField Measurements
Old Meter Calibration• Display• Hold • On/off• Calibration Standard
![Page 31: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/31.jpg)
Conductivity EquipmentField Measurements
Decrease
Increase
![Page 32: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/32.jpg)
Conductivity EquipmentField Measurements
Calibration (Old Meter):• Twist open lid on wider end (battery compartment)• Place narrower end (electrodes) in calibration standard
• Press ON/OFF button and wait for display to stabilize
• When viewed from top, hold meter with white buttons on left
• Press the Increase (top) or Decrease (bottom) button until display reads 720 µS
• When display flashes 3 times, then shows ENT, the meter is calibrated
• Replace lid
![Page 33: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/33.jpg)
Water Conductivity Test ProcedureField Measurements
• Fill sampling container halfway with stream water• Press Power (ON/OFF) button and allow to stabilize to 0 in air• Place meter in sample, stir once, and wait for reading to stabilize• Record result in µS• Rinse container and narrower end of meter (electrodes) with distilled water
![Page 34: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/34.jpg)
Field Measurements
Remember to rinse the narrower end of meter (electrodes) and sampling container with distilled water!
![Page 35: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/35.jpg)
Water Temperature Test ProceduresField Measurements
• Place thermometer at mid-depth of stream in location with constantly flowing water
• Leave thermometer there until readingstabilizes
• Record temperature in degrees Celsius (°C)
![Page 36: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/36.jpg)
This presentation is based on the “Kentucky Watershed Watch Stream Grab Sample Collection Standard Operating Procedure WWSOP02000”and is available fromwww.kywater.org
Grab Sample SOP
![Page 37: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/37.jpg)
Standard OperatingProcedures (SOP)NEW Flip Book
Grab Sample
![Page 38: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/38.jpg)
Watershed Watch Chain of Custody Record
The sampling containers are pre-marked with a unique Site Number
The Site Number should match the number on the “Chain of Custody Record”
Pre-sampling Information
![Page 39: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/39.jpg)
Sample collection locationCollection Procedures
Sample in an area of the stream where the flow is concentratedand where you can completely submerge the bottle without touching the bottom
NOTE: It is important that you collect your sample at the same location each time
![Page 40: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/40.jpg)
Concentrated Flow
Location
Collection Procedures
![Page 41: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/41.jpg)
Grab SampleCollection
• Enter stream at a downstream location • Walk upstream to avoid disturbing bottom • Collect sample at the same location each time in the middle of your concentrated flow location and at mid-depth of stream
Collection Procedures
![Page 42: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/42.jpg)
• Put on disposable gloves• DO NOT RINSE BOTTLE• Point mouth of bottle directly over surface of water, dip and scoop bottle upstream beneath water surface, and through water column in one swift motion to fill above line marked on bottle• If preservative is in bottle, take caution to angle mouth so as not to spill any while collecting sample• Cap container, leaving at least a small airspace at top to allow lab mixing• Place in wet ice immediately
For E. coli grab sample collection:
Collection Procedures
![Page 43: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/43.jpg)
• Put on disposable gloves• Rinse bottle with stream water three times
(fill bottle ¼ full of stream water, cap, shake, and discarddownstream)• Point mouth of bottle upstream (against the flow), submerge entire bottle to mid-depth of stream, scoop and fill• Rinse cap in stream and cap bottle• Add preservative (if necessary) and place in wet ice
Collection Procedures
For grab sample collection other than E. coli:
![Page 44: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/44.jpg)
• Samples must be kept immersed in wet ice(but not frozen) until received by laboratory
• Some samples may require other preservatives(check your sample event packet)
Preservation
![Page 45: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/45.jpg)
Preservation
Sample Holding Time:
• length of time a preserved sample can be stored after collection and before it is analyzed without significantly affecting the results• from the minute you collect a sample, the clock starts ticking on the holding time• varies for different types of analysis• established by the US Environmental Protection Agency
![Page 46: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/46.jpg)
E. coli = 6 hours maximum
Other than E. coli = Follow holding time instructionsreceived in your samplingevent packet
PreservationSample Holding Times
![Page 47: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/47.jpg)
Watershed Watch Chain of Custody Record
• Date and Time of sample collection
• Field Observations and Measurements
• Date and time of sample Relinquished/Received
must be identical
Recordkeeping Volunteer entries on the Chain of Custody
Cross through any mistakes and initial – do not erase
![Page 48: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/48.jpg)
Watershed Watch Chain of Custody Record COC ID # 1234 _ID: 1234
Something new on your chain of custody formThere is now a COC ID number on the top of each chain of custody form. This number changes with every sampling event.This number ties your sampling site to a specific sampling event.
![Page 49: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/49.jpg)
Watershed Watch Chain of Custody RecordCOC _ID: COC ID # 1234
Something new on your chain of custody formThere is now a COC ID number on the top of each chain of custody form. This number changes with every sampling event.This number ties your sampling site to a specific sampling event.
![Page 50: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/50.jpg)
RESULTS
Results will be posted on the Kentucky Geological Survey
website after the basin data manager andKY Watershed Watch have
reviewed for errorshttp://kgs.uky.edu/wwky
![Page 51: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/51.jpg)
Phase 1 (Program Logistics, Field Chemistry and Grab Sample) Training: Your sampling and field testing skills are considered current for three years after completing WWKY-approved training
Training updates must be completed at least every three years
In addition, chemicals must be replaced every three years for your field test results to be accurate. These chemicals should be replaced at your training update.
Recertification
![Page 52: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/52.jpg)
IMPORTANT: If you observe an outfall, pipe, or anything that might indicate illegal pollution of a waterway, contact Kentucky Division of Water to report complaints or concerns at 502-564-3410 during business hours.
For environmental emergencies such as spills of gas, oil or other substances, contact the Environmental Response Team at 502-564-2380 or 1-800-928-2380.
Environmental Safety
![Page 53: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/53.jpg)
Go to your basin’s Watershed Watch Webpage through
the“Quick Links” at:
How do I find out moreabout my basin?
www.kywater.org
![Page 54: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/54.jpg)
Phase 2 – Biological and Habitat Assessment
Habitat Assessment• Stream and Watershed Investigation Methods• Classroom and Streamside Instruction
Biological Assessment• Benthic Macroinvertebrate Collection and Identification Methods• Classroom and Streamside Instruction
![Page 55: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/55.jpg)
Streams are constantly changing
GRAB SAMPLE & FIELD CHEMISTRY• Instantaneous water quality • Quick process• Specific pollutant analysis
BIOLOGICAL & HABITATASSESSMENT• Water quality over time• Takes more time• Collective pollution indication
VS.
![Page 56: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/56.jpg)
Phase 2 (Biological and Habitat Assessment) Training: Your sampling and assessment skills are considered current after completing WWKY-approved training
You will be notified that training updates are required if modifications are made to WWKY methods
Recertification
![Page 57: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/57.jpg)
If you have any questions after today’s workshop,please contact your “Area Coordinator” or the
KY Water Watch Office at 502-782-7032
Questions?
![Page 58: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/58.jpg)
Participant Agreement
Records:
• Accurate contact information
• Equipment loaned
• Site(s) selected
• Training received
![Page 59: Effective Date: 04/01/2013](https://reader036.vdocuments.site/reader036/viewer/2022062501/56816871550346895ddee074/html5/thumbnails/59.jpg)
Fill out Participant Agreement Form, sign and turn into trainer