1 5 2 6 3 7 4 8 ECOTANK® WATER STORAGE TANK INSTALLATION MANUAL The best tank You have purchased an Ecotank® water storage tank. To ensure correct installation, we suggest reading the recommendations provided in this document. WARNING! Non-compliance with the recommendations contained in this manual will void the product guarantee. INSTALLATION SITE RECOMMENDATIONS When choosing the correct site to install an Ecotank® water storage tank, it is important to take into account any applicable regional or national rules and/or regulations regarding this type of installation. The person installing the tank must assess the installation site in terms of environmental conditions such as topography, geology, inclination, potential flood areas, landscape, surface run-off, and vegetation, among others. This is necessary to ensure none of the above factors interferes with the system’s correct functioning or puts the structural integrity of the tank at risk. Choosing an incorrect installation site or ignoring environmental factors that can potentially damage the tank will void the product guarantee. RECOMMENDATIONS FOR CORRECT INSTALLATION Place tank vertically on a level surface and make sure to remove any rocks that could damage the tank bottom. Make sure the ground where tank is to be installed is firm and compact. If very soft or a landfill, partially replace with compacted select fill material. For further details, consult an engineer. Tank should be placed on a bed of sand (75 to 100 mm thick) leaving 40 cm around tank base. Sand must be confined with a concrete or stone rim or metal profile to prevent soil from being washed away by the rain. Another option is to build a reinforced concrete base slab (75 to 100 mm thick). The base slab surface must be flat and extend 40 cm around the tank base. For further information on how to build a base slab, consult an engineer. When tank is installed on an inclined surface, the ground must be correctly contained and rainwater adequately canalized. If tanks are to be mounted on a tower or elevated platform, get help from an engineer to ensure the structure can bear the weight of the tank as well as resist seismic activity and wind. Keep in mind that 1liter of water weighs 1 kilogram. The tank base must be flat. Remember to fasten water pipes to tank platform. When connecting the tank to a pumping system, be sure to install a vent pipe at the top of the tank. Pipe diameter must be at least 38 mm (1 ½ “). In order to minimize movement, fasten the water pipe to a support near its connection to the tank (30 - 50 cm). This will decrease pressure exercised on the tank wall by any movement of the pipe, especially if a pump is installed. Select material fill Sand bed Slab Enbankment Pipe supported on stage Flatbed Vent Pipe support Tank connection

Upload: buikien

Post on 10-Jun-2018

247 views

Category:

Documents


0 download

TRANSCRIPT

1

5

2

6

3

7

4

8

ECOTANK® WATER STORAGE TANK INSTALLATION MANUAL

The best tank

You have purchased an Ecotank® water storage tank. To ensure correct installation, we suggest reading the recommendations provided in this document.

WARNING!Non-compliance with the recommendations contained in this manual will void the product guarantee.

INSTALLATION SITE RECOMMENDATIONSWhen choosing the correct site to install an Ecotank® water storage tank, it is important to take into account any applicable regional or national rules and/or regulations regarding this type of installation.

The person installing the tank must assess the installation site in terms of environmental conditions such as topography, geology, inclination, potential �ood areas, landscape, surface run-o�, and vegetation, among others. This is necessary to ensure none of the above factors interferes with the system’s correct functioning or puts the structural integrity of the tank at risk.

Choosing an incorrect installation site or ignoring environmental factors that can potentially damage the tank will void the product guarantee.

RECOMMENDATIONS FOR CORRECT INSTALLATION

Place tank vertically on a level surface and make sure to remove any rocks that could damage the tank bottom.

Make sure the ground where tank is to be installed is �rm and compact. If very soft or a land�ll, partially replace with compacted select �ll material. For further details, consult an engineer.

Tank should be placed on a bed of sand (75 to 100 mm thick) leaving 40 cm around tank base. Sand must be con�ned with a concrete or stone rim or metal pro�le to prevent soil from being washed away by the rain.

Another option is to build a reinforced concrete base slab (75 to 100 mm thick). The base slab surface must be �at and extend 40 cm around the tank base. For further information on how to build a base slab, consult an engineer.

When tank is installed on an inclined surface, the ground must be correctly contained and rainwater adequately canalized.

If tanks are to be mounted on a tower or elevated platform, get help from an engineer to ensure the structure can bear the weight of the tank as well as resist seismic activity and wind. Keep in mind that 1liter of water weighs 1 kilogram. The tank base must be �at. Remember to fasten water pipes to tank platform.

When connecting the tank to a pumping system, be sure to install a vent pipe at the top of the tank. Pipe diameter must be at least 38 mm (1 ½ “).

In order to minimize movement, fasten the water pipe to a support near its connection to the tank (30 - 50 cm). This will decrease pressure exercised on the tank wall by any movement of the pipe, especially if a pump is installed.

Select material

�ll

Sandbed Slab

Enbankment

Pipe supported on stage

Flatbed

Vent

Pipe support

Tankconnection

1 2 3

4 5

9

6

7 8

lacasadeltanque.com

DIAGRAMA DE INSTALACIÓN DE TUBERÍAMale Adaptor 1/2

Float valve

Filter (optional)

Multiconnector

PVC Tee1/2”

CheckValve

PVC elbow1/2”

Bypass Valve

Water input and output

Entry pipe

support

Flange on tank

PVC Elbow 1/2

INSTALLATION PRECAUTIONS

Do not mount tank on an inclined platform.

Do not mount tank on a platform that is smaller than the tank base.

Do not place tank on an uneven surface.

Do not mount tank on blocks. Should you choose to do so, the space between these should not exceed 3 cm.

Do not install tank below ground. Do not place tank on crushed stone, vegetation, roots or other elements that could damage the tank bottom.

Never install tank in a position other than speci�ed.

Do not manipulate tank if full or partially full of water.

Do not install tank on ground with surface water run-o� or in areas prone to �ooding.

GENERAL RECOMMENDATIONS

• Make sure to wash tank before installing in order to remove

any contaminating particles that might be inside due to

handling and/or transportation.

• Tank should be cleaned every six months to remove particles

and sediment.

• Make sure to properly close tank lid so that sunlight and

especially UV rays do not promote algae growth.

• Do not use bent or twisted pipes or hoses to make

connections as this puts stress on the connection to the tank.

• When using a pumping system, fasten the entry pipe to a

support in order to minimize movement.

• Tank installation site must be easily accessible for inspection

and correct maintenance.

• Never use sharp objects to manipulate the tank (including a

forklift) as these can perforate the tank.

• When storing tank before installation, make sure it is stored

in a vertical position on a level surface.

• Temperature of liquid stored inside the tank must not

exceed 60°C.

• Before installing any accessories, make sure to ask an

authorized dealer.

• Tanks are not fire resistant. Do not use or store near an open

�ame or heat above 80° C.

• Do not obstruct or seal access to the tank inspection lid.

• To ensure adequate water pressure in the case of elevated

tanks, there must be a distance of at least 2 m between the

tank base and highest supply pipe (shower, for example).

GUARANTEEECOTANK® guarantees that its products are free from manufactur-

ing and/or material defects provided these are used in compli-

ance with their intended use. However, in the event of a manufac-

turing and/or material defect within 5 years from the date of

manufacturing, ECOTANK® shall choose at its own discretion to

satisfy a guarantee claim by either repairing or replacing this

product. The company’s liability shall be limited to the cost of the

cistern excluding costs related to installation, removal of

damaged product or any resulting damages.

Neither ECOTANK® nor any of its authorized distributors in Central

America shall be held liable for indirect damages or product

defects resulting from incorrect installation or failure to observe

the above instructions and recommendations.

This guarantee does not cover transportation or labor-related

costs resulting from incorrect installation. The factory guarantee

only covers manufacturing defects.

Ecotank® Tank

””