Page 1: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

INSTALLATIONGUIDE

IMPORTANT SAFETY INSTRUCTIONSREAD AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

ECO-TRAP 110 AND 160WASTE SOLIDS REMOVAL SYSTEM

AQUATIC ECO-SYSTEMS®

Page 2: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

ECO-TRAP 110 and 160 Waste Solids Removal System Installation Guide

i

P/N 930015 Rev. A 10/22/14

TABLE OF CONTENTS

Figure Reference ......................................................................................

Overview ...................................................................................................System Components

Installation ................................................................................................Installing Particle Trap Base in the Center of a Circular Tank Floor

Adhesive and Sealant ApplicationInstalling Particle Trap Plate and InsertMain Drain and Solid Drain Assembly (Under Tank)

For the Solids Drain Assembly, Follow These StepsSludge Collector and Bracket Assembly

Bracket Bolt InstallationSealant Application

Valve Assembly ........................................................................................

Piping System ..........................................................................................

ii

11

22567891414

15

16

If you have questions about ordering Pentair Aquatic Eco-Systems® replacement parts and products, please use the following contact information:

CUSTOMER SERVICE / TECHNICAL SUPPORT

Customer ServiceMonday to Thursday: 8 AM to 7 PM ESTFriday: 8 AM to 5 PM EST

USPhone: (877) 347-4788Fax: (407) 886-6787

InternationalPhone: (407) 886-3939Fax: (407) 886-4884

Web site

Visit www.pentairaes.com

Page 3: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

ECO-TRAP 110 and 160 Waste Solids Removal System Installation GuideECO-TRAP 110 and 160 Waste Solids Removal System Installation Guide

FIGURE REFERENCEFigure 1: Overview of System with Callouts ............................................................................................................1Figure 2: Sludge Collector System Outside Tank ....................................................................................................1Figure 3: Model of Center of Tank ............................................................................................................................2Figure 4: Rendering of Particle Trap in Tank Floor ...................................................................................................2Figure 5: Maximum Inset of Particle Trap Base into Tank Floor ...............................................................................3Figure 6: Dimensions of ECO-Trap 160 ...................................................................................................................3Figure 7: Dimensions of ECO-Trap 110 ...................................................................................................................4Figure 8: Completed Installation ..............................................................................................................................4Figure 9: Assembled Particle Trap Insert, Plate & Base ..........................................................................................5Figure 10: Components of Particle Trap ...................................................................................................................5Figure 11: Particle Trap Base Sitting in Tank ...........................................................................................................5Figure 12: Particle Trap Base Fully Seated in Tank .................................................................................................6Figure 13: Trap Plate Removed ...............................................................................................................................6Figure 14: Installed Trap Plate and Insert ...............................................................................................................6Figure 15: Main Drain Assembly .............................................................................................................................7Figure 16: Solids Drain Assembly ...........................................................................................................................7Figure 17: Particle Trap Base with Metric Adapter ..................................................................................................8Figure 18: C-Channel Attached to I-Beam Bracket .................................................................................................10Figure 19: Attach I-Beam ........................................................................................................................................10Figure 20: Level I-Beam ..........................................................................................................................................10Figure 21: Line up I-Beam Bracket with Pre-Drilled Holes ......................................................................................11Figure 22: Sludge Collector Support and C-Channel ..............................................................................................11Figure 23: Sludge Collector Held in Place by Strap ................................................................................................12Figure 24: Bending Aluminum Strap Around Collector ...........................................................................................12Figure 25: Attaching Strap to U-Channel ................................................................................................................13Figure 26: Opposite Side Attachment .....................................................................................................................13Figure 27: Attach Sludge Collector System to C-Channel ......................................................................................14Figure 28: Adjust Height .........................................................................................................................................14Figure 29: Application of Polyurethane-Based Sealant ..........................................................................................14Figure 30: Adjustment of Discharge Outlet ............................................................................................................14Figure 31: Applying PTFE Tape to the Sludge Collector ........................................................................................15Figure 32: Screwing on the Drain Valve ................................................................................................................15Figure 33: Attaching Nipple to the Valve ................................................................................................................15Figure 34: Conduit Pipe from the Main Drain and Vinyl Reinforced Tubing from the Solids Drain .........................16Figure 35: Attach Clear Reinforced Vinyl Tubing to the Sludge Collector Inlet with Stainless Steel Hose Clamp ..16

ii

Page 4: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

1

OVERVIEW

System Components

FIGURE 1: OVERVIEW OF SYSTEM WITH CALLOUTS

FIGURE 2: SLUDGE COLLECTOR SYSTEM OUTSIDE TANK

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 5: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

2

INSTALLATION Figure 3 and Figure 4 illustrate the Eco-Trap 110 and 160 Waste Solids Removal System drain installed in the center floor of the tank.

Installing Particle Trap Base in the Center of a Circular Tank Floor

FIGURE 3: MODEL OF CENTER OF TANK

FIGURE 4: RENDERING OF PARTICLE TRAP IN TANK FLOOR

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 6: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

3 Figures 5, 6 and 7 show the dimensions along with the tolerances of the Particle Trap Base and Particle Trap Plate installed in a tank.

FIGURE 5: MAXIMUM INSET OF PARTICLE TRAP BASE INTO TANK FLOOR

It is recommended to install the drain flush in the bottom of the tank. The particle trap base may be a maximum of 1/8” below the plane of the tank bottom, but should not protrude. If the particle trap base is protruding from the bottom of the tank solids may become trapped in the system.

FIGURE 6: DIMENSIONS OF ECO-TRAP 160

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 7: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

4

FIGURE 7: DIMENSIONS OF ECO-TRAP 110

Figure 8 is a cutaway view of the drain after correct installation into the bottom of the tank.

FIGURE 8: COMPLETED INSTALLATION

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 8: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

5 Figure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the tank. The Particle Trap Plate can be removed from the Particle Trap Base by unscrewing the plate from the base (Note: For every full revolution the gap opens or closes 1/8”. Figure 10 shows the individual components of the Particle Trap and how they are aligned in the system.

FIGURE 9: ASSEMBLED PARTICLE TRAP INSERT, PLATE & BASE

FIGURE 10: COMPONENTS OF PARTICLE TRAP

Adhesive and Sealant Application The Particle Trap Base is installed using a marine-grade construction adhesive holding it in place, and then a marine-grade sealant is used to fully seat the system in place. Figure 11 shows the base sitting in the tank. On the next page, Figure 12 shows the base fully seated in the tank.

FIGURE 11: PARTICLE TRAP BASE SITTING IN TANK

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 9: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

6

FIGURE 12: PARTICLE TRAP BASE FULLY SEATED IN TANK

Installing Particle Trap Plate and Insert Figure 13 shows the Insert connected to the Trap Plate which is then threaded into the Trap Base once the Base is seated in the tank. Figure 14 shows the Insert, Trap Plate and Trap Base all installed in the bottom of the tank.

FIGURE 13: TRAP PLATE REMOVED

FIGURE 14: INSTALLED TRAP PLATE AND INSERT

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 10: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

7 Main Drain and Solid Drain Assembly (Under Tank)

FIGURE 15: MAIN DRAIN ASSEMBLY Use Schedule 80, or Schedule 40 fittings. The Eco Trap 110 Waste Removal System has a 4” SOC diameter drain, and the Eco Trap 160 has a 6” SOC diameter drain.

FIGURE 16: SOLIDS DRAIN ASSEMBLY

Effluent Pipe

Vinyl Tubing

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 11: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

8 For the Solids Drain Assembly, follow these steps:

1. For the Eco-Trap 110 Waste Solids Removal System, connect 1¼" vinyl reinforced clear tubing to the Sludge Collector inlet with a 1½” stainless steel hose clamp. Connect the other end of the tubing to the Solids Drain outlet with 1½” stainless steel hose clamp. For the ECO-Trap 160, use 1½" or 1¼” vinyl reinforced clear tubing from the valve of your choice, but you must use the appropriate barb adapter from the valve. The tubing must be long enough to reach the Sludge Collector located outside the tank with smooth curves and no kinks in the tubing. A small amount of PTFE-lubricant can be placed on the barb fitting to allow the fitting to be fully inserted into the tubing. NOTE: IT IS NOT RECOMMENDED THAT LUBRICANT BE USED TO CONNECT THE VINYL TUBING DIRECTLY TO THE SLUDGE COLLECTOR DUE TO THE POSSIBILITY OF IT SLIPPING OFF. THE INLET/OUTLET OF THE SLUDGE COLLECTOR ARE NOT BARBED FITTINGS.

2. For metric installations, the 4” or 6” Eco Trap metric adapter must be installed into the Particle Trap Base main drain (Figure 16) and then plumbed into the effluent pipe.

3. The Particle Trap will collect the waste solids and deposit them into the Sludge Collector by way of the 1½” conduit pipe. The effluent pipe will recycle the water back into the Sludge Collector to continue the filtration process.

FIGURE 17: PARTICLE TRAP BASE WITH METRIC ADAPTER

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 12: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

9 Sludge Collector & Bracket Assembly The Eco-Trap Waste Removal System Sludge Collector can be mounted on the tank, WLC, or a wall for the collection of waste solids. The mount has the ability to be adjusted vertically, allowing access to multiple different heights to maintain proper gravity flow. For the attachment of the sludge collector the following steps must be taken:

1. Attach the I-Beam Bracket to the tank with two nuts and bolts, and to the floor with two bolts. Be certain the bracket is level. See Figures 18-20.

2. Attach longer C-Channel to the I-Beam Bracket on the tank with four nuts and bolts (Figure 21). 3. Assemble Sludge Collector Support Bracket to the shorter C-Channel with two nuts and bolts (Figure

22). 4. Insert Sludge Collector into the hole of the Support Bracket with the large open end in the upright

position. 5. The Sludge Collector is held in place within the Support Bracket and C-Channel by the use of an

aluminum strap that is bent around the Sludge Collector (Figures 23-24) and bolted to the C-Channel (Figures 25-26). One of sides of the strap is assembled with the nut on the outside and the bolt on the inside due to the tension on the strap that is holding the Sludge Container in the proper upright position.

6. Attach assembled Sludge Collector with C-Channel to the longer C-Channel mounted vertically on the I-Beam bracket with the use of a Bracket Bolt (Figure 27). This bolt is used to position the C-Channel at the proper elevation in relation to the operating water level of the tank. The Eco Trap 110 must have the U-profile 1.57” below the water level in the tank; the Eco Trap 160 must have the U-profile 6.7” below the water level in the tank. Figure 28 shows how the Bracket Bolt is inserted to hold the sludge collector at the proper elevation for the system.

7. Using the polyurethane sealant provided in the package, apply a layer around the outer rim of the top of the sludge collector body (Figure 29).

8. Assemble the Sludge Collector collar when the desired direction of the discharge is determined. When this is determined, 100% of the polyurethane sealant should be applied. Additional sealant may be applied if the placement of the discharge hose outlet must be changed. Make sure the vinyl tubing is not kinked (Figure 30).

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 13: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

10

FIGURE 18: C-CHANNEL ATTACHED TO I-BEAM BRACKET

FIGURE 19: ATTACH I-BEAM

FIGURE 20: LEVEL I-BEAM

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 14: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

11

FIGURE 21: LINE UP I-BEAM BRACKET WITH PRE-DRILLED HOLES

FIGURE 22: SLUDGE COLLECTOR SUPPORT AND C-CHANNEL

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 15: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

12

FIGURE 23: SLUDGE COLLECTOR HELD IN PLACE BY STRAP

FIGURE 24: BENDING ALUMINUM STRAP AROUND COLLECTOR

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 16: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

13

FIGURE 25: ATTACHING STRAP TO U-CHANNEL

FIGURE 26: OPPOSITE SIDE ATTACHMENT

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 17: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

14 Bracket Bolt

FIGURE 27: ATTACH SLUDGE COLLECTOR

SYSTEM TO C-CHANNEL

FIGURE 28: ADJUST HEIGHT

Sealant Application

FIGURE 29: APPLICATION OF

POLYURETHANE-BASED SEALANT

FIGURE 30: ADJUSTMENT OF DISCHARGE OUTLET

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 18: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

15

VALVE ASSEMBLY The valve that is attached to the Sludge Collector (not included in the package) must be 1½” NPT thread for the Eco Trap 110 and 2” NPT thread for the Eco Trap 160. A 1½” nipple must be used to connect to the 1¼” reinforced clear vinyl tubing (Eco Trap 110) and 1½” reinforced clear vinyl tubing (Eco Trap 160) that will run to the drain.

1. Apply PTFE thread seal tape to the Sludge Collector outlet (Figure 31). 2. Screw on drain valve (Figure 32). 3. Apply PTFE tape to the nipple and attach the nipple to the drain valve (Figure 33).

FIGURE 31: APPLYING PTFE TAPE TO THE SLUDGE

COLLECTOR

FIGURE 32: SCREWING ON THE DRAIN

VALVE

FIGURE 33: ATTACHING NIPPLE TO THE VALVE

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 19: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

16

PIPING OF THE SYSTEM The ECO-Trap Solids Waste Removal System filtration will be the wall of the containment and the Sludge Containment will be outside the containment. The Filtration will collect the sludge and will then deposit it into the Sludge containment by way of the Conduit pipe. The Effluent pipe will recycle the water back into the containment to continue the filtration process. The tubing that will be used is TVR Tubing, TVR125 (ECO110) and TVR150 (ECO160), the clamps that will be used should be all Stainless Steel hose clamps, SSE (1½”) and SSD (1¾”)

FIGURE 34: CONDUIT PIPE FROM THE MAIN

DRAIN AND VINYL REINFORCED TUBING FROM THE SOLIDS DRAIN

FIGURE 35: ATTACH CLEAR REINFORCED VINYL

TUBING TO THE SLUDGE COLLECTOR INLET WITH STAINLESS STEEL HOSE CLAMP

ECO TRAP 110 and 160 Waste Solids Removal System Installation Manual

Page 20: ECO-TRAP 110 AND 160 WASTE SOLIDS REMOVAL SYSTEMFigure 9 Illustrates what the Particle Trap Insert, Plate & Base will look like before installation in the ank. The t Particle Trap

1

2395 APOPKA BLVD., APOPKA, FL 32703 • US (877) 347-4788 • INT. (407) 886-3939

WWW.PENTAIRAES.COM

All Pentair trademarks and logos are owned by Pentair or one of its global affiliates. Pentair Aquatic Eco-Systems® is a trademark and/or registered trademark of Pentair Aquatic Eco-Systems and/or its affiliated companies in the United States and/ or other countries. Unless expressly noted, names and brands of third parties that may be used in this document are not used to indicate an affiliation or endorsement between the owners of these names and brands and Pentair Aquatic Eco-Systems. Those names and brands may be the trademarks or registered trademarks of those third parties. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer.