eca061/chp 61 kw process chiller - riley surface world

5
Home > Process Cooling EquipmentAir Cooled Chillers & Refrigeration > Hitema ECA061/CHP 61 kW Process Chiller Stock Code: CW552 Manufacturer: Hitema Model: ECA061/CHP Year of Manufacture: Jan 2007 Serial: T 01 N 52766 New or Used: Used (Second Hand) Ave. cooling capacity: 61 kW Inlet/Outlet temperature = 12/7 Ave. Water Flow Rate: 9 - 24 m³/hr Other Info: Compact design with great features Weight: 900 External Dimensions (WxDxH): 2310 x 1300 x 2060 The maximum sensitivity to environmental protection is one of the hallmark values of Hitema’s corporate ethos. That’s why Hitema combines its primary goal of delivering efficient and reliable systems with the policy of using ecofriendly HFC refrigerants, which offer the following benefits: - Zero impact on the ozone layer (ODP = 0.00)Limited contribution to greenhouse effectHigh thermal efficiencyEasy control and maintenanceHitema ECA061/CHP Chillers features BASE FRAME The Marketplace for Surface Technology. New and Used Process Equipment & Machinery. Riley Industries Ltd A subsidiary of Barry Riley & Sons Ltd. Director: M P A Riley, Secretary: D Hemming Registered in England no. 1965748 Page 1/5

Upload: others

Post on 14-May-2022

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ECA061/CHP 61 kW Process Chiller - Riley Surface World

Home > Process Cooling EquipmentAir Cooled Chillers & Refrigeration >

Hitema ECA061/CHP 61 kW Process Chiller

 Stock Code: CW552Manufacturer: HitemaModel: ECA061/CHPYear of Manufacture: Jan 2007Serial: T 01 N 52766New or Used: Used (Second Hand)Ave. cooling capacity: 61 kW Inlet/Outlet temperature = 12/7Ave. Water Flow Rate: 9 - 24 m³/hrOther Info: Compact design with great featuresWeight: 900External Dimensions (WxDxH): 2310 x 1300 x 2060

The maximum sensitivity to environmental protection is one of the hallmark values of Hitema’s corporate ethos.That’s why Hitema combines its primary goal of delivering efficient and reliable systems with the policy of usingecofriendly HFC refrigerants, which offer the following benefits: -

Zero impact on the ozone layer (ODP = 0.00)Limited contribution to greenhouse effectHigh thermal efficiencyEasycontrol and maintenanceHitema ECA061/CHP Chillers features

BASE FRAME

The Marketplace for Surface Technology.New and Used Process Equipment & Machinery.

Riley Industries LtdA subsidiary of Barry Riley & Sons Ltd. Director: M P A Riley, Secretary: D Hemming

Registered in England no. 1965748

Page 1/5

Page 2: ECA061/CHP 61 kW Process Chiller - Riley Surface World

Home > Process Cooling EquipmentAir Cooled Chillers & Refrigeration >

Hitema ECA061/CHP 61 kW Process Chiller

The base frame is made of heavy gauge electro-welded tubular steel sections throughout, treated with a hardwearing exterior quality protective finish.

STRUCTURE

The sheet steel structure, which features the same passivation treatment and painting schedule as the base frame,is joined to the base by means of an electro-welding

PANELLING

The panelling is made of steel and finished with the same protective treatment.

MODULARITY

Facility to connect several units in parallel, also using modular chillers made by different manufacturers.

SCALED-DOWN DESIGN

The compact size of the units makes for more efficient use of any available space, with reduced footprints minimisingthe installation area required.

REFRIGERANT CIRCUIT MODULARITY

Total cooling capacity is generated by dual compressors rather than relying on a single large size unit. This solutionmakes it possible to divide the total capacity into a series of steps and use reliable and economical standardcomponents, thereby achieving clear manufacturing and functional benefits.

CHILLER COMPRESSOR

The primary chiller compressors utilise tandem configuration, featuring high efficiency compressors to ensure verycompetitive COP values: -

Hermetic reciprocating compressor cooled by liquid refrigerant on the suction side and protected by thermal overloadand overcurrent relays

Hermetic scroll compressor operating with very high efficiency levels and low electrical power consumption

Semi-hermetic screw compressor equipped as standard with four capacity steps.

The electric motors feature part-winding start technology and are protected from overheating by means ofthermistors embedded in the stator winding

DUAL REFRIGERANT CIRCUIT EVAPORATORS

Self-cleaning coaxial type with high turbulence swirl profile.

The Marketplace for Surface Technology.New and Used Process Equipment & Machinery.

Riley Industries LtdA subsidiary of Barry Riley & Sons Ltd. Director: M P A Riley, Secretary: D Hemming

Registered in England no. 1965748

Page 2/5

Page 3: ECA061/CHP 61 kW Process Chiller - Riley Surface World

Home > Process Cooling EquipmentAir Cooled Chillers & Refrigeration >

Hitema ECA061/CHP 61 kW Process Chiller

Direct expansion type with an innovative water/gas design, constructed of heavy gauge copper pipes, immersed inthe storage tank, thermally insulated and crossed by reverse-flows of gas-water that make it possible to achieve thefollowing:

maximum effective heat exchangezero thermal dispersionoperation of the compressor with low compression ratiowith a consequent high efficiency coefficient

AIR-COOLED CONDENSERS

Plate core type cooling condensers with mechanically expanded copper tubes in an aluminium finned core(pre-painted on request) with swirl profile to increase turbulence and hence heat exchange efficiency, complete withsub-cooling function.

REFRIGERANT CIRCUIT

The refrigerant circuits feature a bi-compressor, in tandem configuration with welds executed using silver alloywelding.Refrigerant circuit components: -Mechanical lamination valveFilter-drier - Liquid and moistureindicatorMuffler - Suction separator with relief valveSafety pressure switches on high and low pressuresidesPressure connections for charging and discharging refrigerant fluidClearly visible dual scale pressure gauges

PERFECT CONTROL OF PROCESS FLUID TEMPERATURE

Perfect temperature control is achieved through the use of compressors with continuous capacity control combinedwith a system of hot gas injection to the evaporator. This solution, combined with our 316 AISI stainless steelhydraulic unit, is ideal for cooling of “aggressive” industrial processes in which the temperature differential must bemaintained at ≤ 1°C.

COMPLETE HYDRAULIC CIRCUIT

The flexibility of the hydraulic circuit configuration greatly facilitates the installation and commissioning of Hitemaunits.The hydraulic circuit includes: - Storage tank Relief valveClearly visible pressure gaugeEvaporator protectionflow switchAutomatic air separatorAutomatic filling unit with clearly visible pressure gaugeManual by-pass

SEMI-GRAPHICS USER INTERFACE

Hitema’s microprocessor control systems perform real-time surveillance and prevention strategies. All the mainfunctions of Hitema units are protected against anomalous or potentially harmful operating conditions. Thissafeguard simplifies troubleshooting operations and minimises maintenance times.

TECHNICAL SPECIFICATIONS

The Marketplace for Surface Technology.New and Used Process Equipment & Machinery.

Riley Industries LtdA subsidiary of Barry Riley & Sons Ltd. Director: M P A Riley, Secretary: D Hemming

Registered in England no. 1965748

Page 3/5

Page 4: ECA061/CHP 61 kW Process Chiller - Riley Surface World

Home > Process Cooling EquipmentAir Cooled Chillers & Refrigeration >

Hitema ECA061/CHP 61 kW Process ChillerNOMINAL COOLING CAPACITY Frig/h 52,600NOMINAL COOLING CAPACITY kW 61 COMPRESSOR NOMINAL ABSORBED POWER kW 19.2 NOMINAL COOLING CAPACITY ** kW 84.3                                                      COMPRESSOR NOMINALABSORBED POWER ** kW  21.1COMPRESSORS nr. 2CIRCUITS nr. 1PARTION STEP nr. 1

HYDRAULIC SECTION

MINIMUM FLOW m3/h 9 MAXIMUM LIFT bar 3,4 MAXIMUM FLOW m3/h 24 MINIMUM LIFT bar 1.9PUMP ABSORBED POWER KW 2.7 PUMP ABSORBED CURRENT A  5                                                                           HYDRAULIC CONNECTIONSBSP/DN 2" DN 65                                                                TANK VOLUME dm3 550 

FAN SECTION

TOTAL AIR FLOW m3/h 21,000 FANS nr. 2FANS ABSORBED POWER KW 1.92 FANS ABSORBED CURRENT A 8.4 

TOTAL ELECTRICAL DATA

ABSORBED POWER (F.L.I.) KW 30.6 MAXIMUM ABSORBED CURRENT (F.L.A.) A 53.6 MAXIMUM PEAK CURRENT (M.I.C.) A 132 

NOISE DATA

SOUND PRESSURE dB(A) 69 

DIMENSIONS AND WEIGHT

LENGTH mm 2000 WIDTH mm 1300 HEIGHT mm 2060 WEIGHT kg 900

Refurbished in June 2017 by Comptec Ltd commissioned only and not run to date.

The Marketplace for Surface Technology.New and Used Process Equipment & Machinery.

Riley Industries LtdA subsidiary of Barry Riley & Sons Ltd. Director: M P A Riley, Secretary: D Hemming

Registered in England no. 1965748

Page 4/5

Page 5: ECA061/CHP 61 kW Process Chiller - Riley Surface World

Home > Process Cooling EquipmentAir Cooled Chillers & Refrigeration >

Hitema ECA061/CHP 61 kW Process ChillerView Hitema ECA061/CHP 61 kW Process Chiller on our web site athttps://www.rileysurfaceworld.co.uk/machines/28170.htm

PHOTOGRAPHS TAKEN PRIOR TO REFURBISHMENT.

The Marketplace for Surface Technology.New and Used Process Equipment & Machinery.

Riley Industries LtdA subsidiary of Barry Riley & Sons Ltd. Director: M P A Riley, Secretary: D Hemming

Registered in England no. 1965748

Page 5/5