eaton capitole salesaid eng

8
• Distribution • Motor control • Package substations Capitole Low voltage switchgear and control gear assemblies • Flexibility • Reliability • Availability • Value for money, whatever the application

Upload: nid2009

Post on 06-Apr-2018

228 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Eaton Capitole Salesaid ENG

8/3/2019 Eaton Capitole Salesaid ENG

http://slidepdf.com/reader/full/eaton-capitole-salesaid-eng 1/8

• Distribution

• Motor control

• Package substations

Capitole

Low voltage switchgear and

control gear assemblies

• Flexibility

• Reliability

• Availability

• Value for money,

whatever the application

Page 2: Eaton Capitole Salesaid ENG

8/3/2019 Eaton Capitole Salesaid ENG

http://slidepdf.com/reader/full/eaton-capitole-salesaid-eng 2/8

• Type tested AN D certified only!

• Mod ular b uild  - Pl ug -in  - M IN IM UM 

foot print b ut not compromise cabling

• Meters  - need analog ue and digital 

options  - digital m ust comm unicate!

• C ustomers need locking facilities!!

• fast deli very

 Distrib ution

• M ust  ha ve f ull range of de vices  - A C Bs 

 - M C C Bs  -  F used -switc hes  - M C Bs 

(SP/ TP + ne utral links/4 pole)

• C hange -o ver and interlocks essential

• C Ts  ha ve to be incorporated in 

str uct ure  - easy to fit e ven in ser vice

• Constr uction m ust be rigid  - end frame type best!!

• Ne utrals  ha ve to be f ully rated

• Cabling  -  has to be fast and easy, m ust 

 ha ve plenty of space, access from front, 

remo vable gland plates

• M C C Bs  - want c hoice of toggle or rotary 

 handle

 L V Sys tem wis h lis t

Page 3: Eaton Capitole Salesaid ENG

8/3/2019 Eaton Capitole Salesaid ENG

http://slidepdf.com/reader/full/eaton-capitole-salesaid-eng 3/8

Notes

Motor control and distrib ution• Mod ular b uild  - 

• m ust incorporate motor control 

and/or distrib ution as req uired  - 

incl uding b uilding ser vices!!!

• Arc -free design 

• safe to modify li ve  - absol ute M US T  HA VE

• O utgoing fixed/wit hdrawable/

pl ug -in options

• Compact starters  - excellent 

space  usage  - N B cabling m ust 

still be easy

• Con ventional and intelligent motor control essential

• S h utters m ust be a vailable for 

wit hdrawable starters  - PER IO D..

• IP41 minim um,  IP54 option

• Pl ug -in de vices essential for M C Cs and switc hboards

• Rigid constr uction  using end -frames best for strengt h and * 

flexibility of application

Page 4: Eaton Capitole Salesaid ENG

8/3/2019 Eaton Capitole Salesaid ENG

http://slidepdf.com/reader/full/eaton-capitole-salesaid-eng 4/8

Capitole 40

Electrical data

Rated operational voltage 690 V

Rated frequency 50/60 Hz

Main busbar data

Rated insulation voltage 1000 V

Rated impulse withstand voltage 12 kV

Rated current 6300 A

Rated short-time withstand current 80 kA 1s

Rated peak withstand current 220 kA

Vertical distribution busbar data

Rated insulation voltage 1000 V

Rated impulse withstand voltage 12 kV

Rated current 1420 A

Rated short-time withstand current 80 kA 1s

Rated peak withstand current 176 kA

Outgoing units withdrawable / fixed / plug-in

Enclosure data

Degree of protection IP41 (IP54 on request)

Form of separation Form 4a Type 2,

Form 4b Types 3, 6 and 7

Entry of cables Top and/or bottom

Access Front or rear

Standard Colour RAL 7035

Standards IEC 60439-1, BS EN 60439-1

Certifications KEMA-Keur, Lloyd's Register of shipping

Technical data

Page 5: Eaton Capitole Salesaid ENG

8/3/2019 Eaton Capitole Salesaid ENG

http://slidepdf.com/reader/full/eaton-capitole-salesaid-eng 5/8

System flexibility

• Compartments for withdrawable units may be

modified without process supply interruption

• Standard and reduced height cubicle designs

with configurations for front/rear connection,

top/bottom cable entry

• Corner cubicle facilitates right-angled assemblies

• Up to 32 units per column

• Wide range of optional modules

- Clink motor management system

- Soft starters

- Frequency converters (variable speed drives)

- PLC controlled change-over systems

- Power factor correction

Maintenance

• Low maintenance design

• All components/connections accessible

from the front

except for rear cable connections

• Maintenance-free withdrawable unit contacts

• Contact blocks may be quickly changed

Optional fully insulated mainbusbar system

Safe connection of outgoing cables evenunder live busbar conditions

Fully withdrawable motor starter

Capitole 40LV Distribution and Motor Control System

Certified to national

Personal safety

• Form 4a Type 2, Form 4b Types 3, 6 and 7 internal

segregation

• Shutters guard the distribution busbars when

drawers are removed

• Designed to limit effects of internal arcing faults

- Possible to connect outgoing cables with

switchboard live

• Fault-free zone option:

- Insulated main busbars

- Incomer – busbar connections insulated

- Phase segregation of incoming and busbar side

terminals of incoming devices

Operational reliability

• Unique plug-in contacts for withdrawable units –

prevent wear, short-circuit damage and welding

• Vertical busbars enclosed in insulated chamber

• Segregation continuous up to and including

withdrawable main contacts – precludes faults

• Quality controlled manufacturing guarantees all

fixings, including terminations, correctly tightened

Page 6: Eaton Capitole Salesaid ENG

8/3/2019 Eaton Capitole Salesaid ENG

http://slidepdf.com/reader/full/eaton-capitole-salesaid-eng 6/8

Rotary handle operated MCCBs andfused switches

Toggle operated MCCBsKema Keur CertifiedType Tested Assembly

and international standards

Capitole 20LV Distribution System

Reliability by design

• Designs for IEC, Euro-norm and British

Standard markets

• Kema Certified as a Type Tested Assembly

• On-going build quality and compliance with the

Type Tested design monitored by Kema under

the Kema Keur scheme

Safe to use, easy to maintain

• Form 4a Type 2 – Form 4b Type 6 segregation

using rigid metallic or insulating materials

• Door-interlocked operating handles, locked

doors and screw-fixed cover plates

• Minimum IP2x shrouding internally

• Plug-in MCCB and fused-switch disconnector

modules up to 1000 A

• ACBs withdrawable or fixed

Functionally flexible

• Modular design provides maximum flexibility

and minimum build time

• May be re-configured on-site if necessary

• Top and/or bottom cable entry

• Full spectrum of protection, metering, Building

Management System and supply change-over

options

 Wide choice of modules

• Standard devices in a modular design ensure

perfect balance between size, electrical capacity,

and cost

• Modular design is ideal for use with the Eaton

Bid Manager software which provides price

and size data in a matter of minutes for most

assemblies

• Complete spectrum of Eaton distribution and

control devices

- Air circuit breakers

- Moulded case circuit breakers

- Fused switches

- Switch disconnectors

- Power factor correction

High Density Device Mounting

• Minimised switchboard size whilst maintaining

both excellent cabling access and flexibility

- Up to 24 devices in one column

- Feeder modules up to 250 A

twin device plug-in

- Feeder modules up to 1000 A

single device plug-in

- Feeder modules above 1000 A

single or twin device

Page 7: Eaton Capitole Salesaid ENG

8/3/2019 Eaton Capitole Salesaid ENG

http://slidepdf.com/reader/full/eaton-capitole-salesaid-eng 7/8

Capitole 20

Electrical data

Rated operational voltage 690 V

Rated frequency 50/60 Hz

Main busbar data

Rated insulation voltage 1000 V

Rated impulse withstand voltage 12 kV

Rated current 3200 A

Rated short-time withstand current 50 kA and 65 kA 1s

Rated peak withstand current 110 kA

Vertical distribution busbar data

Rated insulation voltage 1000 V

Rated impulse withstand voltage 12 kV

Rated current 2x1250 A (centre fed)

Rated short-time withstand current 50 kA 1s

Rated peak withstand current 110 kA

Outgoing units plug-in

Enclosure data

Degree of protection IP31

Form of separation Form 4a Type 2, Form 4b Type 6

Entry of cables Top and/or bottom

Access Front

Standard Colour RAL 7035

Standards IEC 60439-1, BS EN 60439-1

Certifications KEMA-Keur

Technical data

Page 8: Eaton Capitole Salesaid ENG

8/3/2019 Eaton Capitole Salesaid ENG