earthwork take-off - siteworkdata - home take-off disclaimer project name: popeyes chicken - horizon...

6
EARTHWORK TAKE-OFF Disclaimer PROJECT NAME: POPEYES CHICKEN - Horizon City, TX DATE OF TAKE-OFF : 07/06/2014 EARTHWORK TAKE-OFF BY: SiteworkData.com SiteworkData uses grading plans to generate earthwork take-offs. Geo-technical data provided will be used to designate any over excavation and or stripping thicknesses. Since we based our take-offs on grading plans provided by client, We try to do our best to pick up any errors and/or omissions the plans may have; if any assumption is taken by SiteworkData it will be noted. All SiteworkData earthwork takeoffs daylight to existing terrain at boundary. Any areas beyond the boundary line will not be calculated unless specifically dictated by client. SiteworkData Takeoffs are provided for informational purposes only, the user of this information is to assume the ultimate responsibility of checking any quantities and graphic representations stated and shown in this takeoff document and hereby agrees to indemnify and hold SiteworkData harmless from and against all claims of any type or nature asserted by customer or any party for the use of this information document. Due to the nature of digital files the client is responsible for any trojan/virus detection and removal. It is the client responsibility to detect/intercept and/or remove any computer viruses before loading any SiteworkData file. SiteworkData should be hold harmless from and against all claims of any type or nature asserted by customer or any party as a result of any computer viruses/trojans and or attacks inadvertently caused, transmitted with, and/or along any digital and electronic files.

Upload: dangnhi

Post on 06-May-2018

228 views

Category:

Documents


4 download

TRANSCRIPT

EARTHWORK TAKE-OFFDisclaimer

PROJECT NAME: POPEYES CHICKEN - Horizon City, TX

DATE OF TAKE-OFF : 07/06/2014

EARTHWORK TAKE-OFF BY: SiteworkData.com

SiteworkData uses grading plans to generate earthwork take-offs. Geo-technical data provided will be used to designate any over excavation and or stripping thicknesses. Since we based our take-offs on grading plans provided by client, We try to do our best to pick up any errors and/or omissions the plans may have; if any assumption is taken by SiteworkData it will be noted. All SiteworkData earthwork takeoffs daylight to existing terrain at boundary. Any areas beyond the boundary line will not be calculated unless specifically dictated by client. SiteworkData Takeoffs are provided for informational purposes only, the user of this information is to assume the ultimate responsibility of checking any quantities and graphic representations stated and shown in this takeoff document and hereby agrees to indemnify and hold SiteworkData harmless from and against all claims of any type or nature asserted by customer or any party for the use of this information document. Due to the nature of digital files the client is responsible for any trojan/virus detection and removal. It is the client responsibility to detect/intercept and/or remove any computer viruses before loading any SiteworkData file. SiteworkData should be hold harmless from and against all claims of any type or nature asserted by customer or any party as a result of any computer viruses/trojans and or attacks inadvertently caused, transmitted with, and/or along any digital and electronic files.

QUANTITY SUMMARY

PROJECT NAME: POPEYES CHICKEN - Horizon City, TX

SWPP * NOTES

Silt Fence 604.30 LF

Temp Entrance 1.00 EA NO GEO-TECH PROVIDED

NO SWELLING FACTORS

SITE DEMOLITION * APPLIED

DEMOLITION BOLLARDS 0.00 EA

DEMOLITION BUILDING SLAB 0.00 SF

DEMOLITION CONCRETE 0.00 SF

DEMOLITION ASPHALT 5,817.40 SF

DEMOLITION CURB 0.00 LF

EARTHWORK (0% Expansion – 0% Compression ) no Geo-Tech Provided

Work area 36,354.00 SF

Work area 0.83 AC

Cut to fill 559.70 CY

Export 636.20 CY

497.80 CY

SUBGRADES

422.01 SY

304.23 SY

2,330.87 SY

0.00 SY

0.00 SY

1,306.80 LF

HMAC PAVMENT LIGHT *

Area SF 20,977.80 SF

Area SY 2,330.87 SY

HMAC Thickness 2.00 IN

BASE Thickness 6.00 IN

HMAC MATERIAL 269.22 TONS

BASE MATERIAL 884.56 TONS

STORM SEWER *

18” RCP 101.10 LF

24” RCP 42.80 LF

AREA INLET 1.00 EA

24” RCP TIE IN 1.00 EA

18” RCP CONCRETE CAP 1.00 EA

SiteworkData

Over Ex & Re-compact

Sub-grade Prep. Concrete

Sub grade Prep. Building

Sub grade Prep. HMAC LIGHT

Sub grade Prep. HMAC MED

Sub grade Prep. HMAC HEAVY

Sub grade Prep. Curb

SUBGRADE SUMMARY

PROJECT NAME: POPEYES CHICKEN - Horizon City, TX

SUBGRADES NOTES

Area, FT2 Perimeter, FT Volume, YD3

Concrete Pavement 6" 1,612.00 312.50 29.90

Concrete Pavement 6" 121.50 44.50 2.20

Sidewalk 4” 155.30 73.00 1.90

Sidewalk 4” 1,047.90 470.20 12.90

Sidewalk 4” 861.40 339.10 10.60

HMAC 2” over 6” 20,977.80 1,650.40 518.00

Building Pad -4” 2,738.10 243.40 50.70

SiteworkData

Sub-grade Name

PLANS

GRADING PLAN

CUT AND FILL COLOR

FILL 5.2

CUT 5.2

SiteworkData

A

B

CROSS SECTIONSSECTION “A” (RED = PROPOSED // GREEN = EXISTING)

SECTION “B” (RED = PROPOSED // GREEN = EXISTING)

SiteworkData

SATELLITE AND STREET VIEW IMAGES SiteworkData

https://www.google.com/maps/@31.6822212,-106.2008081,135m/data=!3m1!1e3

https://www.google.com/maps/@31.6822626,-106.2000732,3a,75y,253.47h,75.73t/data=!3m4!1e1!3m2!1sZ7YxXp91M-NLDsNDbNBqxg!2e0