    INGENIERA TTULO: HOJA DE DATOS DE PROCESO- P-1101A/B CALENTADOR DE PROPANO

    N DE CONTRATO:

    RESPONSABLE TCNICO: PEDRO PINZN

    NMERO INTERTECHMA: E-FD-FLO049-PRO-450-501

    PROGRAMA: ESTUDIOS, INGENIERA BSICA E INGENIERA DE DETALLE

    REA:TERMINAL MARTIMO Y PLANTA DE ALMACENAMIENTO DE

    GLP EN MONTEVERDE

    HOJA DE DATOS DE PROCESO No. E-FD-FLO049-PRO-450-501

    CLIENTE: FLOTA PETROLERA ECUATORIANA HOJA: 1 de 4

  • 8/3/2019 E-FD-FLO049-PRO-450-501-RA

    2/4

    Revised: Date: Approved: Date:

    Client: FLOPEC

    Project:

    Location: MONTEVERDE

    Tag: P-1101A/B

    Service of Unit Item No.

    Size 26,0000 x 240,000 inch Type AES Horz. Connected In 1 Parallel 1 Series

    Surf/Unit (Gross/Eff) 1720,02 / 1691,35 ft2 Shell/Unit 1 Surf/Shell (Gross/Eff) 1720,02 / 1691,35 ft2

    PERFORMANCE OF ONE UNIT

    Fluid Allocation

    Fluid Name

    Fluid Quantity, Total lb/hr

    Vapor (In/Out)

    Liquid

    Steam

    Water

    Noncondensables

    Temperature (In/Out F

    Specific Gravity

    Viscosity cP

    Molecular Weight, Vapor

    Molecular Weight, Noncondensables

    Specific Heat Btu/lb-F

    Thermal Conductivit Btu/hr-ft-F

    Latent Heat Btu/lb

    Inlet Pressure psia

    Velocity ft/sec

    Pressure Drop, Allo psi

    Fouling Resistance ( ft2-hr-F/BtuHeat Exchanged Btu/hr 25889261 MTD (Corrected) 48,3 F

    Transfer Rate, Service 316,81 Btu/ft2-hr-F Clean 427,01 Btu/ft2-hr-F Actual 427,01 Btu/ft2-hr-F

    Sketch (Bundle/Nozzle Orientation)

    Tube Side

    Design/Test Pressur psig

    Design TemperatureF

    No Passes per Shell

    Corrosion Allowanceinch

    Connections In inch

    Size & Out inch

    Rating Intermediate

    Tube 438 OD 0,7500 inch Thk(Avg) 0,0650 inch Length 20,000 ft Pitch 0,9843 inch Layout 90

    Tube Type Plain Material : SA-213 UNS S31254 (20 Cr, 18 Ni) or similarShell ID 26,0000 inch OD inch Shell Cover A-203 Gr.D or similar

    Channel or Bonnet By supplier Channel Cover By supplier

    Tubesheet-Stationary By supplier Tubesheet-Floating By supplier

    Floating Head Cover By supplier Impingement Plate None

    Baffles-Cross Type SINGLE-SEG. %Cut (Diam) 30,0 Spacing(c/c) 20,0000 Inlet 30,8061 inch

    Baffles-Long Seal Type

    Supports-Tube U-Bend Type

    Bypass Seal Arrangement Tube-Tubesheet Joint

    Expansion Joint Defined by supplier Type

    Rho-V2-Inlet Nozzle 845,52 lb/ft-sec2 Bundle Entrance 599,24 Bundle Exit 1003,19 lb/ft-sec2

    Gaskets-Shell Side Reinforced Graphite Tube Side

    -Floating Head

    Code Requirements TEMA Class RWeight/Shell 12034,7 Filled with Water 17204,7 Bundle 4932,28 lb

    Remarks:

    - Design by ASME VIII-Div-1 2007 ADD 2009 & TEMA 8th Ed.

    Reprinted with Permission (v5 )

    Reinforced Graphite

    1 @ 12,0900

    1 @ 12,0900

    @

    1 @ 12,0900

    1 @ 12,0900

    @

    CONSTRUCTION OF ONE SHELL

    270,000 / Per Code

    100,00

    1

    Shell Side

    270,000 / Per Code

    120.00

    2

    4,05

    5,360

    169,000

    13,30

    28,970

    1,0318

    0,3392

    243,000

    0,0601

    49,98

    1,0193

    1,2995

    13934001393400

    67,98

    1,0119

    1,0017

    0,5087

    0,0767

    1,0309

    0,3488

    507383

    0,6063

    0,1257

    40,98

    0,5290

    -51,26

    0,5924

    0,2150

    507383

    507383

    Tube Side

    1393400

    8/3/2010 M.R. 8/3/2010

    Shell Side

    P.P.

    PROPANO AGUA DE MAR

    HOJA DE DATOS DE PROCESOCALENTADOR DE PROPANO

    Rev. No. Prepared:

    SISTEMA IMPERIAL

    A N.P. 8/3/2010

    TERMINAL MARTIMO Y PLANTA DE ALMACENAMIENTO DE GLP EN MONTEVERDE

    E-FD-FLO049-PRO-450-501

    Date:

    20,000 ft

    26,0000 inch

  • 8/3/2019 E-FD-FLO049-PRO-450-501-RA

    3/4

    Revised: Date: Approved: Date:

    Client: FLOPEC

    Project:

    Location: MONTEVERDE

    Tag P-1101A/B

    Service of Unit Item No.

    Size 660,401 x 6096,00 mm Type AES Horz. Connected In 1 Parallel 1 Series

    Surf/Unit (Gross/Eff) 159,79 / 157,13 m2 Shell/Unit 1 Surf/Shell (Gross/Eff) 159,79 / 157,13 m2

    PERFORMANCE OF ONE UNIT

    Fluid Allocation Shell Side Tube Side

    Fluid Name

    Fluid Quantity, Total 1000-kg/hr 230,147 632,042

    Vapor (In/Out)

    Liquid 230,147 230,147 632,042 632,042

    Steam

    Water

    Noncondensables

    Temperature (In/Out C -46,25 4,99 19,99 9,99

    Specific Gravity 0,5924 0,5290 1,0119 1,0193

    Viscosity cP 0,2150 0,1257 1,0017 1,2995

    Molecular Weight, Vapor

    Molecular Weight, Noncondensables

    Specific Heat kcal/kg-C 0,5087 0,6063 1,0309 1,0318

    Thermal Conductivit kcal/hr-m-C 0,1141 0,0894 0,5188 0,5046

    Latent Heat kcal/kg

    Inlet Pressure bar-G 15,741 10,639

    Velocity m/s 1,24 4,05

    Pressure Drop, Allo bar 0,370 1,997

    Fouling Resistance ( m2-hr-C/kcalHeat Exchanged MM kcal 6,5197 MTD (Corrected) 26,8 C

    Transfer Rate, Service 1545,74 kcal/m2-hr-CClean 2083,42 kcal/m2-hr-C Actual 2083,42 kcal/m2-hr-C

    Sketch (Bundle/Nozzle Orientation)

    Shell Side Tube Side

    Design/Test Pressur barG

    Design TemperatureC

    No Passes per Shell

    Corrosion Allowancemm

    Connections In mm

    Size & Out mm

    Rating Intermediate

    Tube 438 OD 19,050 mm Thk(Avg) 1,650 mm Length 6096, mm Pitch 25,000 mm Layout 90

    Tube Type Plain Material : SA-213 UNS S31254 (20 Cr, 18 Ni) or similarShell ID 660,401 mm OD mm Shell Cover A-203 Gr.D or similar

    Channel or Bonnet By supplier Channel Cover By supplier

    Tubesheet-Stationary By supplier Tubesheet-Floating By supplier

    Floating Head Cover By supplier Impingement Plate None

    Baffles-Cross Type SINGLE-SEG. %Cut (Diam) 30,0 Spacing(c/c) 508,001 Inlet 782,476 mm

    Baffles-Long Seal Type

    Supports-Tub U-Bend Type

    Bypass Seal Arrangement Tube-Tubesheet Joint

    Expansion Joint Defined by supplier Type

    Rho-V2-Inlet Nozzle 845,52 lb/ft-sec2 Bundle Entrance 599,24 Bundle Exit 1003,19 lb/ft-sec2

    Gaskets-Shell Side Reinforced Graphite Tube Side

    -Floating Head

    Code Requirements TEMA Class RWeight/Shell 5,459 Filled with Water 7,804 Bundle 2,237 Kg

    Remarks:

    - Design by ASME VIII-Div-1 2007 ADD 2009 & TEMA 8th Ed.

    Reprinted with Permission (v5 )

    @

    CONSTRUCTION OF ONE SHELL

    2

    1 @ 307,087

    1 @ 307,087

    Reinforced Graphite

    18,616 /Per Code

    37,78

    1

    1 @ 307,087

    1 @ 307,087

    @

    18,616 /Per Code

    54.44

    03-08-10

    PROPANO AGUA DE MAR

    P.P. 03-08-10 M.R.

    HOJA DE DATOS DE PROCESOCALENTADOR DE PROPANO

    SISTEMA INTERNACIONAL

    TERMINAL MARTIMO Y PLANTA DE ALMACENAMIENTO DE GLP EN MONTEVERDE

    E-FD-FLO049-PRO-450-501

    Rev. N Prepared: Date:

    A N.P. 03-08-10

    6096, mm

    660,401 mm

  • 8/3/2019 E-FD-FLO049-PRO-450-501-RA

    4/4

    Revised: Date: Approved: Date:

    Client: FLOPECProject:

    Location: MONTEVERDE

    Tag: P-1101A/B

    NOTAS:

    1- El proveedor debe garantizar el rendimiento hidrulico y termodinamico del equipo para las condiciones operativas.

    2- El diseo hidrulico y termodinmico del equipo debe ser confirmado por el proveedor.

    3- El anlisis de vibracin y el rendimiento acstico del equipo debe ser diseado por el proveedor.

    4- Toda la informacin en esta hoja de datos se refiere a cada equipo.

    5- El proveedor de los calentadores debe proveer los CLIPS para el aislamiento trmico.

    6- ESTAMPE ASME U : SI

    7- Nivel radiogrfico : RT18- Aislamiento Trmico / Proteccin Personal : Ver spec E-ET-FLO049-TUB-200-0039- Corrosin admisible : 1/8"

    10- Material sugerido esparragos/tuercas: A-320 Gr. L7 / A-194 Gr.4

    11- Recubrimiento (Si se usa CS ) : 3-MILS Zinc Inorgnico + 5 MILS Epoxico + 2 MILS Poliuretano (Partes no aisladas)

    12- Composicin del Propano Comercial.

    Ethane

    Propane

    n-Butane

    i-Butane

    n-Pentane

    H2O

    Total

    PROPANO COMERCIAL

    Mass Fractions

    4,60 %

    81,40 %

    Mole Fractions

    6,8 %

    82,4 %

    100 %

    6,1 %

    4,5 %

    0,1 %

    0,0 %

    8,00 %

    5,90 %

    0,10 %

    0,00 %

    8/3/2010 M.R. 8/3/2010

    TERMINAL MARTIMO Y PLANTA DE ALMACENAMIENTO DE GLP EN MONTEVERDE

    HOJA DE DATOS DE PROCESOCALENTADOR DE PROPANO

    NOTAS

    E-FD-FLO049-PRO-450-5018/3/2010 P.P.