e-165 (flash) experiment status report

27
E-165 (FLASH) Experiment Status Report Johnny S.T. Ng SLAC EPAC Meeting, Nov. 15, 2003

Upload: corbin

Post on 20-Jan-2016

40 views

Category:

Documents


0 download

DESCRIPTION

E-165 (FLASH) Experiment Status Report. Johnny S.T. Ng SLAC EPAC Meeting, Nov. 15, 2003. SLAC E-165 Experiment. Fl uorescence from A ir in Sh owers (FLASH) J. Belz 1 , Z. Cao 2 , F.Y. Chang 4 , P. Chen 3* , C.C. Chen 4 , C.W. Chen 4 , - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: E-165 (FLASH) Experiment Status Report

E-165 (FLASH) ExperimentStatus Report

Johnny S.T. Ng

SLAC

EPAC Meeting, Nov. 15, 2003

Page 2: E-165 (FLASH) Experiment Status Report

Fluorescence from Air in Showers(FLASH)

J. Belz1, Z. Cao2, F.Y. Chang4, P. Chen3*, C.C. Chen4, C.W. Chen4, C. Field3, P. Huentemeyer2, W-Y. P. Hwang4, R. Iverson3, C.C.H. Jui2,

G.-L. Lin4, E.C. Loh2, K. Martens2, J.N. Matthews2, J.S.T. Ng3, A. Odian3, K. Reil3, J.D. Smith2, P. Sokolsky2*, R.W. Springer2,

S.B. Thomas2, G.B. Thomson5, D. Walz3

1University of Montana, Missoula, Montana2University of Utah, Salt Lake City, Utah

3Stanford Linear Accelerator Center, Stanford University, CA4Center for Cosmology and Particle Astrophysics (CosPA), Taiwan

5Rutgers University, Piscataway, New Jersey

* Collaboration Spokespersons

SLAC E-165 Experiment

Page 3: E-165 (FLASH) Experiment Status Report

Outline

• Introduction: Motivation and Goals

• Report on the Sep.2003 Run– Thin-target results– Spectrograph results

• Plans and outlook– Thick-target stage

Page 4: E-165 (FLASH) Experiment Status Report

Motivation

• Recent observations of ultra-high energy cosmic ray events extend out to 1020 eV

• However, there is apparent discrepancy between AGASA and HiRes > ~1019 eV

Page 5: E-165 (FLASH) Experiment Status Report

• Cosmic Rays have been observed with energies beyond 1020 eV

• The flux (events per unit area per unit time) follows roughly a power law: ~E-3

• Changes of power-law index at “knee” and “ankle”.

Onset of different origins/compositions?

Where does the spectrum stop?

Ultra High Energy Cosmic Rays

Page 6: E-165 (FLASH) Experiment Status Report

AGASA

HiRes

Discrepancy Between Two UHECR Experiments

Page 7: E-165 (FLASH) Experiment Status Report

Motivation (cont.)

• Recent observations of ultra-high energy cosmic ray events extend out to 1020 eV

• However, there is apparent discrepancy between AGASA and HiRes > ~1019 eV

• Systematics in energy measurement being investigated by both experiments.

• One possible contribution to the discrepancy is the air fluorescence yield.

Page 8: E-165 (FLASH) Experiment Status Report

Current Understanding of the Air Fluorescence Spectrum

• Bunner (1967), Kakimoto et al. (1995), Nagano et al. ( 2002) indicates ~15% systematic errors in overall yield and larger errors in individual spectral lines.

• Ground based experiments – non-linear effects possible due to λ-4 dependence of atmospheric attenuation.

• At 30 km, event energy can change by 25% if 390 nm line intensity changes by 40%.

Page 9: E-165 (FLASH) Experiment Status Report

Experimental Program

• The T-461 Test (June 2002) showed that we can measure the pressure dependence and fluorescence lifetime integrated over 300-400 nm with FFTB beams

Spectrally resolved pressure and lifetime measurements

Energy dependence over realistic shower energies

• The E-165 program:

Thin target

Thick target

T-461

Page 10: E-165 (FLASH) Experiment Status Report

Objectives Of E-165

• Spectrally resolved measurement of fluorescence yield to better than 10%.

• Study effects of atmospheric impurities.• Observe showering of electron pulses in

air equivalent substance (Al2O3) with energy equivalents around 1018 eV.

• Investigate dependence on electron energy.

Page 11: E-165 (FLASH) Experiment Status Report

Sep. 2003 Run: Thin Target• FFTB Beam: 28.5 GeV, 5E8 – 2E9 e/pulse• Main target vessel:

– Dry air, N2, “SLAC Air”, 10-760 Torr– Narrow-band filters (10nm BW, 300-420 nm)– Calibrated HiRes PMTs

• Spectrograph system– Dry air, N2, “SLAC Air”, 15-760 Torr– Hamamatsu linear-array MPMT’s– Grating spectrograph system: 6 nm and 4 nm

per pixel

Page 12: E-165 (FLASH) Experiment Status Report

Thin-Target Run: Main Vessel Layout

e

Pressure vessel

NB Filterwheel

CalibrationLED housing

e

Filter wheel

PMT

Pressure vessel

Page 13: E-165 (FLASH) Experiment Status Report

OTR Beam Spot Monitor

e

Monitor beam spot size and position

Provide energy profile diagnostics as well

Wonderful contribution from

the CosPA (Taiwan) group

45-deg

OTR foil

Page 14: E-165 (FLASH) Experiment Status Report

E-165: Air Fluorescence Spectrum

• Narrow Band filters

• Dry-Air

• 750 Torr

• Arbitrary normalization

• N1A: Corrected for filter transmission and quantum efficiency

Preliminary

Bunner

Page 15: E-165 (FLASH) Experiment Status Report

Air Fluorescence vs. PressureE-165 Preliminary

Page 16: E-165 (FLASH) Experiment Status Report

Effects of Contaminants

•“SLAC Air”: H2O, and traces of CO2 and Ar

•Possible slight difference, but within our present measurement accuracy.

E-165 Preliminary

Page 17: E-165 (FLASH) Experiment Status Report

Beam-related Background

Various measurements as cross-checks: “Black”-filter, “Blind”-PMT, and Ethylene (non-fluorescent) gas.

Page 18: E-165 (FLASH) Experiment Status Report

Narrow-Band Data Analysis

• Data have been corrected forFilter transmission efficiencyPMT Quantum efficiencyBackground contribution

• Further systematic issues (some examples): Absolute calibration: PMT + Mirror + Filter Absolute calibration of low-current toroid Stability (gain variation over time, etc.) Uncertainty in background subtraction Detector acceptance (ray-tracing + modeling)

Page 19: E-165 (FLASH) Experiment Status Report

Grating Spectrograph

• e

Light pipe

and mirrorGrating

Spectrograph

Page 20: E-165 (FLASH) Experiment Status Report

Spectrograph Measurement: AirE-165 Preliminary!

Page 21: E-165 (FLASH) Experiment Status Report

Spectrograph: Fluorescence vs. Pressure

E-165 Preliminary

At low pressure (<100 Torr): Fluorescence mechanisms extremely complex! Sensitive to non-linear effects.

Above ~150 Torr (for HiRes,eg): Small pressure variation Allows altitude spectral correction

Page 22: E-165 (FLASH) Experiment Status Report

Spectrograph Data Analysis

• Data have been corrected for:PMT quantum efficiency vs wavelengthAnode - anode difference in responseWavelength dependence of transmission to PMTSpectral dispersion at the PMT face (measured using a

mercury lamp with 4 useful lines.)

• Further systematic issues (some examples):Independently measure transmission and associated uncertainties.Calibrate dispersion for the wider-range grating set-upQuantify the non-linear effects seen at higher beam intensities and

low pressures.

Page 23: E-165 (FLASH) Experiment Status Report

Summary on Thin-Target Run

• Over-all successful thin-target run• Measured spectrally resolved fluorescence for various pressures and gas mixtures• Took reference data at low beam charge (1E7 e/pulse) for the thick-target stage• Beam-related background (most likely soft photons from shower) was a major problem• Detailed data analysis underway – plan to present results at the upcoming “International Workshop on Air Fluorescence – Air Light 03” in December 2003.

Page 24: E-165 (FLASH) Experiment Status Report

The Next Step: Thick-Target• For a 1018 eV cosmic-ray proton, or a 30 GeV electron,

the cascade consists of electrons with energies between 100 keV and a few GeV at shower-max.

• Pass electron beam through varying amounts of approx. air equivalent showering material (Al2O3).

• Measure light yield as a function of depth in the shower – Is fluorescence proportional to dE/dx?– What are the contributions of low-energy (<1 MeV) electrons?– Can existing shower models (EGS, GEANT,

CORSIKA) correctly predict fluorescence light?

Page 25: E-165 (FLASH) Experiment Status Report

Thick Target Requirements

• Low beam intensity ~ 107 e/pulse– Beam monitor and control

• Showering beam spreads out at target exit – Careful calculation/measurement of optical acceptance necessary.

• Need shower profile measurements to constraint Monte Carlo simulations

• Beam-related background issue– Beam test scheduled for Jan. 5-7, 2004 to optimize layout

and shielding

Page 26: E-165 (FLASH) Experiment Status Report

Thick Target Setup

Design to be finalized pending beam test and further simulation studies.

Page 27: E-165 (FLASH) Experiment Status Report

Summary

• E-165 is an experiment with the aim to contribute and support astrophysics investigations using high energy beams.

• We’re making good progress thanks to the strong support from SLAC.