dynascan ds1016 quickstart guide
DESCRIPTION
DynaScan DS1016 Quickstart GuideTRANSCRIPT
Ver.1.01 DS1016 Quick Start Guide
1 Hardware Quick Start 1.1 Location of Control Box
The following drawing is the top view of control and power space allocation under the display.
Maintenance /Power Outlet
Maintenance /Air Con. tube
Power Control /
Space DVI&
RS-2
32/
AC/D
C
Maintenance
Front Side
Open here Open here
Open here
Lock
Lock
Maintenance
#A
#B
#C#1
#2
#3
#4
#5
#6
Maintenance /Power Outlet
Maintenance /Air Con. tube
Power Control /
Space DVI&
RS-2
32/
AC/D
C
Maintenance
Front Side
Open here Open here
Open here
Lock
Lock
Maintenance
#1
#2
#3
#4
#5
#6
#A
#B
#C
There are 3 external doors available to open. The computer /player with DVI output can be put in the spare space (#1), and connect to DVI & RS-232 panel (#5).
Copyright © 2008 DynaScan Technology Corp. 1
Ver.1.01 DS1016 Quick Start Guide
1.2 Power Input and Consumption
L
N
L
NFor Display
For Air Conditioner You will see the terminal block when you open the
maintenance door (#2). Please tightly secure the
power line on the terminal block as shown.
GGround
The power control box has two AC power cables. One
is for the display with input power 25A@220Vac
(maximum), the other is for the air conditioner with
input power 19A@220Vac (maximum). We suggest
that you install the each power line on the 40A
Breakers separately.
N (Black)L (RED)
Ground (Green)
Copyright © 2008 DynaScan Technology Corp. 2
Ver.1.01 DS1016 Quick Start Guide
1.3 Air Conditioner Power Connection 2. Secure the 7 wires with marks from power control
base as shown below.
15A Circuit Breaker Power Switch for air con. A
RJ-45 network cable adapter
Red line from power control base (A/C A L)
2 black lines from power control base (A/C A N)
There are two wiring boxes fixed under the top in the
air con. base, and the below one locates on the left for
air con. A connection.
1. Secure the wires marked as below from the
power control base on the terminal block. (3
power cords for air con. A)
Function Air con. B Power Color L (Red) N (Black) Mark A/C B L A/C B N
Function Air con. A control Color 1 (White) 2 (Black)(2 Lines)Mark A/C A 1 A/C A 2
Function Air con. B control Color 1 (White) 2 (Black) Mark A/C B 1 A/C B 2
3. Turn on the power switch of air con. A after finishing the wiring.NOTE: Please be sure to keep the power switch of air con. A on when operating to cool the power control base
chamber.
CAUTION: If the power switch of air con. A were not on, the power control base chamber will be over-heated.
Copyright © 2008 DynaScan Technology Corp. 3
Ver.1.01 DS1016 Quick Start Guide
1.4 Video and Control Connection
You will see the panel as you open the DVI & RS-232 door (#5). Please connect DVI out and COM port from the
computer to the panel respectively. The Monitor System software from DynaScan can support the display mode
control, e.g. brightness, spin speed and offset etc., and read the current temperature of the drum.
COM Port DVI Port
Voltage Meter AC/DC Converter
Copyright © 2008 DynaScan Technology Corp. 4
Ver.1.01 DS1016 Quick Start Guide
1.5 Display Operation
1.5.1 Power ON/OFF Steps
1. Turn ON/OFF the power switch for the display.
2. Turn ON/OFF the air con. switch for air conditioner.
CAUTION: Please do not change the default settings of inverter and thermal switch for safety.
Panel of Inverter
Air Con.
Power
Thermal Switch
Copyright © 2008 DynaScan Technology Corp. 5
Ver.1.01 DS1016 Quick Start Guide
2 Function / Maintenance Introduction2.1 Monitor System Operation
2.1.1 Start Program Follow the path (Program Files -> DynaScan Monitor System 2007 -> MonitorSystem2007); an icon shall appear at the right of the task bar near the clock. Right click on this icon, and then choose <Restore> to activate
the operation window.
As action 1, right click the mouse at the display list to
show the “Pop Menu”. Press “New” to show the
“Append” dialogue as action 2. Enter the name and
model of the display and the RS232 Port used into the
“Machine Data” field in the “Option Page”, then click
<Append>. A new display is now added.
Copyright © 2008 DynaScan Technology Corp. 6
Ver.1.01 DS1016 Quick Start Guide
2.1.2 Simple Operation Provide functions to operate the display.
NOTE: For more instruction of Monitor System 2007, Please refer to the Monitor System 2007 User Manual.
Spin Speed:
Set spinning speed for the image of the displayer.
Tick <Fixed> and the image of the displayer shall stop
spinning. Pull the bar of the <Stage> from low to high;
the spinning speed shall increase accordingly.
Brightness:
Brightness adjustment.
Set the degree of brightness of the displayer. Different
types of displayer have different levels of brightness.
Power On / Off:
Turn on/off the power of the displayer manually.
Power On: Turn on the display.
Power Off: Turn off the display.
Caution: This action shall cause the “Schedule” to pause.
Copyright © 2008 DynaScan Technology Corp. 7
Ver.1.01 DS1016 Quick Start Guide
2.2 Unpacking
There are two wooden crates. One is display, and the other is the base and Air con.
Step 1. Disassemble the wooden top cover, and side covers. Step 2. We suggest you lift the display and move to the installation site.
Display
Step 3. Disassemble the wooden top cover, and side covers.
Step 4. We suggest you lift the base and move to the installation site.
Base
Copyright © 2008 DynaScan Technology Corp. 8
Ver.1.01 DS1016 Quick Start Guide
2.3 Move the Machine
Lift the Display
If you want to lift the display, you must disassemble the display with the base first. To lift the display, you need to install the eyebolt on the triangle hanging frame and use the lifting device.
NOTE: For more instruction of Display lifting, please refer to the complete version
user manuals provided in the Disc.
Move the display
If you want to move the display, you must use a hand pallet truck.
Caution: When you use a hand pallet truck to move the display, please move it carefully and slowly.
Caution: Please be sure that the screws and connecting pipes and cables between the display and the air
conditioner base are removed and disconnected completely.
Caution: Please make sure that you fasten the eyebolt firmly, or the eyebolt
may not carry the display’s weight and the display will fall down
Copyright © 2008 DynaScan Technology Corp. 9
Ver.1.01 DS1016 Quick Start Guide
2.4 Ground Mounting
For Safety Reason, you must do the ground mounting to fasten the display onto the ground.
Step1. Use Type J, M20*630mm foundation screw inter to the ground in advance, with the drawing shown below.
Front Side
NOTE: Please Ensure that the tension strength
of each foundation screw with concrete
ground mount surface is no less than
2500kg. The ground mounted work must
be done by civil engineering specialists.
After the work is complete, we advise that
the reliability of it be checked and
approved by authorities concerned in
your area for safety purpose. The Ground
must be concrete base.
Conduit
Power Cord Hole
Front Cover
Copyright © 2008 DynaScan Technology Corp. 10
Ver.1.01 DS1016 Quick Start Guide
Type J, M20*630 foundation screw
Step2. Move the display to the preferred place and use the
nuts to fix it. Tighten the M20 screws to fix the ground-fixing
block with the display.
Copyright © 2008 DynaScan Technology Corp. 11
Ver.1.01 DS1016 Quick Start Guide
3 Reference3.1 Specifications
Model DS1016 LED Type Lamp
Pitch (H x V) 2.0mm x 2.0mm
Resolution 1530x 768 x 1 screen (Full wrap)
Brightness > 7500 cd/
Color 16.7 millions
Contrast Ratio > 5000 : 1
Screen Size (Diagonal) 75” Diagonal x 3
Total Display Area (W x H) 3.06 m x 1.54 m x 1
Viewing Angle(H x V) >170 x 60o o
Physical Dimension (D x H) 1.14m x 3.36m
Physical Weight 1080Kg
Power Supply 1 ,200~240 VAC, 50/60 Hz, 40A
Cooling System Power Supply 1 ,200~240 VAC, 50/60 Hz, 40A
Color Spectrum Red: 630nm Green: 525nm Blue: 470nm
Safe Ambient Temperature From -20 to 45 C o o
Copyright © 2008 DynaScan Technology Corp. 12
Ver.1.01 DS1016 Quick Start Guide
3.2 Legal Notices Intel lectual property; limited license to users The hardware and software of our products are protected by copyr ight , t rademark, patent , and/or other intel lectual property laws, and any unauthor ized use of the software, t rademarks containing herein may violate such laws and the software l icense agreement. Except as expressly provided herein, DynaScan and i ts suppl iers do not grant any express or impl ied r ights to use any product re lated hardware and software. DynaScan is registered trademark of DynaScan Technology Corp. in R.O.C and\or other countr ies. Microsoft is registered trademark of Microsoft Corp. Moonl ight is registered trademark of Moonl ight cordless Ltd. IBM is registered trademark of IBM Corporat ion. Other t rademarks are trademarks of their respect ive owners. Disclaimer Speci f icat ions and information contained herein are furnished for informational use only. Revisions are periodically made to the information herein; these revisions will be incorporated in later editions. Improvements or changes in the products or the programs described may be made at any time and are subject to change without notice, and should not be construed as a commitment made by DynaScan. This manual could include mistyping or typographical errors. DynaScan assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. Exclusion of Damages:
DynaScan Technology Corporat ion’s l iabi l i ty is l imi ted to the cost of repair or replacement of the product.
DynaScan Technology Corporat ion shal l not be l iable for : 1. Damages to other property caused by any defect in the product, damages based upon
inconvenience, loss of use of the product, loss of t ime, loss of prof i ts , loss of business opportuni ty, loss of goodwi l l , interference with business relat ionships, or other commercial loss, even i f advised of the possibi l i ty of such damages.
2. Any other damages, whether inc idental , consequent ia l or otherwise. 3. Any cla im against the customer by any other party.
Copyright © 2008 DynaScan Technology Corp. 13
3.3 Disposal Notices
Do not dispose of electrical appliances as unsorted municipal waste,
use separate collection facilities. Contact your local government for
information regarding the collection systems available. If electrical
appliances are disposed of in landfills or dumps, hazardous substances
can leak into the groundwater and get into the food chain, damaging
your health and well-being. When replacing old appliances with new
one, the retailer is legally obligated to take back your old appliances for
disposal at least for free of charge.
NOTE: Please refer to the complete version user manuals provided in the Disc for full safety and operation info of the displays.
Copyright © 2008 DynaScan Technology Corp. 14
MEMO
Copyright © 2008 DynaScan Technology Corp. 15
Copyright © 2008 DynaScan Technology Corp. 16